MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

Similar documents
MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Installation Instructions

SERVICE BY QUALIFIED PERSONNEL ONLY

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

BACKUP BATTERY INSTALLATION INSTRUCTIONS

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

MaxLite LED Round Pendant Highbay Series

MaxLite LED Vapor Tight Linear Fixture

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

CDL8 LED Architectural

Installation Instructions

Universal Fan and Light Remote Control

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

LED Emergency Battery Backup

Model 4001 Series Single Channel Controller

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

ESRB and ESRN Installation & Safety Instructions

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

HIGH BAY APPLICATIONS

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

MaxLite LED High Bay Fixtures

Continuous Relay Controller LC52 Series Owner s Manual

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Instruction Manual. Carmel Apple-Dip Warmer

INSTALLATION, OPERATION AND MAINTENANCE

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

GAS MONITOR Model Model

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Spectron LSN (Life Safety Network) Suggested Specifications

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

Guide Specification Model CTG Automatic Transfer Switch

MaxLite LED MICRO-T PANEL

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

DRC12FR DRC12FR347. Dynalite. Install Guide

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

ELECTRIC FIREPLACE OWNER S MANUAL

User s Manual and Warranty Information ThyssenKrupp Access

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Spa Control System OWNER S MANUAL

Instruction Manual and Warranty

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Product Specifications Warning Light Control Cabinet

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

Intelligent Lighting Controller

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

09/23/2013. RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased:

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

MaxLite Polygon Linear LED Light

Panel Mounted Heat Exchangers by Dantherm, Inc.

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Interrupted Ignition Series Oil Primary Control

Installation & Maintenance Instructions

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

CT2 Retro Box Installation Instruction Manual

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Multiple Boilers Electro TS Series Application EB-C-STG5

OPERATING INSTRUCTIONS

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Model TL104 MANTL104. Test Lamp for Flame Detection

Innovative Lighting R-Series Vertical Refrigeration

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Innovative Lighting R-Series Overhead LED Conversion Kits

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Product Specifications Warning Light Control Cabinet

READ AND SAVE THESE INSTRUCTIONS

Instruction Manual. Nacho Cheese Dispenser and Warmer

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Instruction Manual. Cheese Warmer with Pump

52 BERKSHIRE CEILING FAN

ESP TECHNOLOGIES LIMITED

Product Specifications Linear Accelerator Relay Junction Box

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

SEALING FIBER SEALING COMPOUND

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

LOSBAY800. BAY SENSOR Installation Manual. LOSBAY800 Specifications

Instruction Manual Model L2 RF Switch

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Installation, Operation & Service Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual

Power Supply Display Module PSDM. Installation and Operation Manual

Transcription:

MODEL EPC-D-F-ATS INSTALLATI INSTRUCTIS! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIS 1. This product can be used with LED, ballast, tungsten, and general use loads. 2. Make sure all connections are in accordance with the National Electrical Code and local regulations. 3. To reduce the risk of electric shock, disconnect both normal and emergency power supplies before servicing. 4. This product is intended to be used to control indoor and outdoor located loads. 5. An unswitched AC power source is required (120-277VAC). 6. Do not install near gas or electric heaters. 7. Do not attempt to service a sealed Lighting Transfer Switch. When malfunctioning, return to the manufacturer: LVS, Inc. 2555 Nicholson Street, San Leandro, CA 94577. 8. The use of accessory equipment is not recommended by the manufacturer and may cause unsafe condition. 9. Do not use this product for other than its intended use. 10. Servicing should be performed by qualified service personnel. 11. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. SAVE THESE INSTRUCTIS 5-Year Limited Warranty LVS, Inc. warrants to the original purchaser/user for the published warranty period from the date of shipment that should LVS instruments or equipment prove defective by reason of improper workmanship or material, LVS will repair or replace the same equipment without charge. This warranty does not cover defects or malfunctions arising from improper installation, operation or repair, or neglect, accident, or abuse. LVS will honor its warranty provided the equipment has not been physically damaged or improperly installed or connected. To obtain warranty/repair, the defective product should be shipped freight prepaid within the warranty period to the address below. To the extent permitted by applicable law, all warranties extending beyond repair or replacement as described above are disclaimed, including the implied warranties of merchantability and fitness for a particular purpose. Where applicable law prohibits disclaimers or the implied warranties of merchantability and fitness; those warranties are limited to 12 months from date of shipment. LVS provides a 90 day money back guarantee if equipment does not perform in accordance with LVS published specifications. The liability of LVS and its agents under all warranties is limited to repair and replacement as described herein and under no circumstances shall there be liability for any other kind of loss, damage, or labor, either consequential or for injury to person or property or otherwise. Electrical Specfications 120-277V Sensing Input 16 Amp Ballast Rating (120-277V) 16 Amp General Use Rating (120-277V) 1920W Incandescent Rating (120V) 4432W Incandescent Rating (277V) UL1008 Listed (usul/cul) U L C US UL1008 LISTED Mechanical Specifications Mounts in 4-11/16 Junction Box with Extension Box UL94-5VA Plastic Flame Rating Shipping Weight: 22 oz Color : White Temperature: 0 C-60 C (32 F - 140 F) Flush Mounted Size: 6 x 6 x 1/2 Body Size: 4-1/4 x 4-1/4 x 2-1/4 LVS LVS, Inc. 2555 Nicholson Street, San Leandro, CA 94577-4216 Phone: 510-352-9600 1-800-982-4587 Fax: 510-352-6707 Web: WWW.LVSCTROLS.COM 1

Application In the past, all emergency lights were left on 24 hours a day to meet safety codes. Now you can specify & install a UL1008 Listed Lighting Transfer Switch EPC-D-F-ATS, which converts up to 16A of normal light fixtures to approved emergency lights. During normal operation, the EPC-D-F-ATS feeds designated emergency lights from the normal power circuit and allows them to switch or dim with the same control as your normal lights. During a utility power interruption, the EPC-D-F-ATS feeds designated emergency lights from the emergency power circuit, at full brightness, regardless of switch or dimmer position. Intended for use with 2 WIRE, 3 WIRE, and 4 WIRE DIMMABLE LOADS (includes line voltage and 0-10V dimming, as well as / s). Three testing methods: Integral Test Switch provides convinient anytime testing. Automatic Test Option provides automatic and monthly self-testing. Fire Alarm/Dry Contact Option allows emergency lighting activation from fire, security alarm or remote test switch. Four safety and reliability interlocks: Voltage Sensing Interlock senses back-feed or erroneous voltage on load terminals during transfer through optically isolated sensors. Time Delay Interlock ensures break-before-make transfer operation. Reduces or eliminates phase-phase arcing risk. Relay Position Detection detects relay malfunction (such as welding) and alerts microprocessor to stop transfer to prevent phase-phase shorting across relays. Mechanical Interlock unique contact arrangement of relays prevents normal and emergency sources from being connected, even if all other interlocks fail. Surface Mount Installation Flush Mount Installation EPC-D-F-ATS Includes: Flush adaptor ring Plastic 1/2 lock nut Suggested Box: (Not included) 4-11/16 (2-1/8 deep) and 2-1/8 Extension Box For plenum applications: Suggested Box: 6x6 or 8x8 box with blank cover (Not Included) Plenum rated test switch is available upon request 2

Method of Operation The model EPC-D-F-ATS is a single-zone silent transfer switch for emergency lighting applications. Versatile, small, and cost effective, and designed to work with all modern dimming types including 2-wire and 3-wire line voltage, 0-10V and DALI low voltage. EPC-D-F-ATS is compatible with all lighting types includ-ing LED, fluorescent, incandescent.the EPC-D-F-ATS allows emergency and normal lighting to be dimmed from the same dimmer during normal operation. During emergency operation (power interruption), the EPC-D-F-ATS will transfer the emergency lighting to the emergency power source and bypass all dimming controls, bringing the emergen-cy lighting to 100% (full) brightness, regardless of dimmer level. A momentary test switch on the front cover allows the user to simulate a power interruption when pressed. Installation In order to install device in accordance with national/local code requirements, a qualified electrician should review & understand the installation instructions. Check voltage & current requirements. Verify & lock out circuit breakers on both regular (utility) power & 24 hour emergency generator or inverter circuit. Install a self-adhesive 2" x 3" caution label in each fixture or load controlled by an EPC-D-F-ATS unit caution-ing that this load is supplied from 2 different power sources, regular & emergency. Review wiring diagram & connect wires, one at a time, in accordance with the numeric identification. Initial Testing Final Testing CAUTI This light fixture is powered by 2 circuits: the 24-hour nightlight / emergency circuit must be turned off in addition to the regular power branch circuit breaker before servicing this light fixture. Notes for use: USE CU WIRE LY Utiliser des fils en cuivre uniquement Suitable for total system transfer. Input: 120-277VAC 50-60Hz Unit Power Consumption: 7W Max Continuous Current not to exceed 100% of switch rating 120-277 volt 16 Amp Ballast 120-277 volt 16 Amp Tungsten 120-277 volt 16 Amp General Use When protected by a fuse of the specific manufacturer, type, and ampere rating as marked below, this transfer switch is suitable for use in circuits capable of delivery 5000A at 277V. Littelfuse KLK-30 30 Amps Littelfuse KLKR-30 30 Amps 3

2-WIRE DIMMABLE LOADS Panel Normal Normal (optional) #1 #4 #13 #8 #9 3-WIRE DIMMABLE LOADS Panel Normal Normal (optional) Dim Dim #1 #8 #4 #13 #9 Dim 4-WIRE DIMMABLE LOADS Normal (optional) Panel Normal Purple Purple #1 #8 #4 #13 #9 Purple 4

EPC-D-F-ATS DIP SWITCH TINGS No MonthlyAutomatic Test No Fire Alarm/Remote Test Switch DEFAULT (replaces EPC-D-F) No Monthly Automatic Test YES Fire Alarm/Remote Test Switch (N/C) YES Monthly Automatic Test No Fire Alarm/Remote Test Switch YES Monthly Automatic Test YES Fire Alarm/Remote Test Switch (N/C) No Monthly Automatic Test YES Fire Alarm/Remote Test Switch (N/O) YES MonthlyAutomatic Test YES Fire Alarm/Remote Test Switch (N/O) Monthly Automatic Test feature will test EPC-D-F-ATS for 40 seconds every 25 days and record result on microprocessor. Test results may be played back by test. Annual testing for 90 minutes is still required and recommended. Fire Alarm/Remote Test switch input is optional. Cut red jumper wire and connect 24V DC power to it through a dry contact. For N/C type, when contact is closed EPC-D-F-ATS will transfer to emergency source. For N/O type, when contact is open EPC-D-F-ATS will transfer to emergency source. 24V Power Supply 24V(+) COM(-) Fire Alarm Dry Contact Red Red EPC-D-F-ATS Note: EPC-D-F-ATS red wires are polarity independent