LPI Lightning Warning System - LWS MKIII

Similar documents
LPI Lightning Warning System (LWS) MKIII

LPI Lightning Warning System (LWS) MKIII

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Networked Access Control Panel. Installation Guide

LOCAL STORM DATA SHEET

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

Electronic Siren Systems

BodyGuard Proximity Warning System

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

WAVE SEQUENCER DELIVERS:

Architectural and Engineering Specification for a. Flash / Flare

Batt-Safe Battery String Monitoring System

EXTINGUISHING AGENT RELEASE MODULE

sintra Sintra is a trademark of Asya Traffic INC.

ATFLASH. Sensor ATFLASH SENSOR USER GUIDE ATFLASH. Sensor ATFLASH SENSOR USER GUIDE

Intelligent Security & Fire Ltd

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Fratech Multipath-IP STU

Intelligent addressable fire alarm control panel

SHAWNEE PARK SPORTS COMPLEX EMERGENCY OPERATIONS PLAN

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Architectural and Engineering Specification for a Real-Time Locating System Flare

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Smart Wireless Sensor

Combi B Alarm box. Mounting instructions

C-Bus Four Channel Analogue Output Unit Installation Instructions

SEE DISCLAIMER ON REVERSE

products and services

Installation and Operation Manual. Wireless Indoor Strobe

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

WAVE Siren USER GUIDE

MTDPC. (also known as MTPC) INSTALLATION AND OPERATION MANUAL MultiTrode Pump Controller

CMT MANUAL 6. NMC SENSORS

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

Med Touch Master Alarm

C-Bus Four Channel General Input Unit Installation Instructions

Alarm Tone Generator Model AG17

Smart Wireless Sensor

WH EN IGH T T C LO SED

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

Status Date Prepared Reviewed Endorsed Approved

Fiber Optic Cable Fence Disturbance Sensor

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

PERMACONN PM1030 Includes DI300. Installation Manual

One giant leap for safety: AZM400.

Fratech Multipath-IP

Front page TBA from Marketing. Network and Device Monitoring. Starter Kit

Patriot Systems Limited

600 Range Dialer Installation Manual. Version 1.0

HART XL High Sensitivity Smoke Detection

FlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE

Installation and Operation Manual

HART XL High Sensitivity Smoke Detection

TW-8000 TAUT WIRE FENCE

Tri-Tech Medical Inc.

MINERVA MZX125 Digital Addressable Fire Detection System

Access Control (card access)

User manual and installation guide

Preparing. Your connection checklist. for the nbn Fixed Wireless network. For help and support. Installation approval

YachtSafe GPS Alarm Manual

AS950 PORTABLE SAMPLERS

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

idware Idware Remote Site Monitoring Solution

User Guide. Sky Muster service. Includes information about your nbn supplied equipment

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Your connection checklist

TABLE OF CONTENTS. Page 2

Wireless Call Point ( )

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

MK9 series CarePhone. Installers Mauual

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Continuous, real-time detection, alarming and analysis of partial discharge events

Why Hart XL Aspirating Smoke Detection?

1U ULTRA Compact System

SC315 RECTANGULAR RAPID FLASHING BEACON. MUTCD-compliant, pedestrian-activated warning beacon for uncontrolled marked crosswalks

Workplace Safety North

Addressable Fire Alarm Control Panel

G.M. Advanced Fencing & Security Technologies Ltd

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

HARDwired Installation/ Owner s Manual

Section 5 Brieser Construction SH&E Manual

Heimdall Radar Traffic Detector

Tri-Tech Medical Inc.

STRIKE GUARD DELIVERS:

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

IMPORTANT INFORMATION ABOUT LIGHTNING DETECTION SYSTEM

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!


PART 8 - Miscellaneous Services 3rd Revised Sheet 1 SECTION 8 - Other Miscellaneous Services Replacing 2nd Revised Sheet 1

Model RC-10 INSTRUCTION MANUAL

How the People Counter Works. Enhanced Safety, Security and Building Automation, and Improved Marketing Intelligence. 3D MLI Sensor Technology

Transcription:

LPI Lightning Warning System - LWS MKIII Features Early detection of lightning activity within approximately 25km Alarm signalled when lightning approaches within approximately 8-10km All Clear indication provided once the storm has passed Wireless communication between console and multiple sensors Flexible installations to suit different applications Product Description The LPI Lightning Warning System is a non-directional lightning detection instrument designed to provide indication of nearby lightning strikes and significant changes in the local electrostatic field. The LPI Lightning Warning System MKIII provides the user with the ability to manage the lightning risk and to fulfil a duty of care to employees, customers and all related personnel. As occupational health and safety laws strengthen globally, senior management across a wide variety of industries and recreational pursuits are now faced with a realisation that they have a duty to warn individuals of the pending risks associated from lightning. Recent court cases have shown a dramatic change from the once acceptable Act of God defence, to a realisation that management now has a duty to warn. Figure 1: Lightning Warning System Overview Commercial in Confidence Document: 36 TD LWS MKIII.pub Version: 2.00 05/11/2008 Copyright 2008 LPI 1

LWS Operation On detection of a nearby lightning event or significant increase in the electrostatic field, the system will provide a Warning or Alarm to personnel that an event has occurred or is likely to occur. Detection and Alarm Indication (via a siren) is performed by the sensor unit (see figure 2), with results being sent wirelessly to the console for more detailed event indication and logging. (see figure 1) LWS Functionality Figure 2: How the LWS works LWS Console The LWS MkIII Console is the interface which communicates to the sensors installed in the field and allows the user to access information about the current lightning event status (near, far or all clear) and the current electrostatic field level (high or low electric-field). The Console is typically sited in a secure location where it can either be connected directly to a computer by cross-over Ethernet cable, or by straight-through Ethernet cable to a local network, allowing the user to access the relevant data and system settings. The Console also has alarm relay outputs for Alarm, Warning and All Clear suitable for switching contacts. LWS Sensor Assembly The LWS Sensor Assembly (Microprocessor, Sensing Antenna, Alarm/Warning/All Clear Indicator and Earth Rod) is the integral component of the LWS system, it provides all decision making in regards to recorded lightning events and subsequent alerts. The LWS Sensor Assembly is typically mounted at a suitable location at site and the monitoring of all lightning activity is controlled by an on board microprocessor, which works in conjunction with the sensing antenna to detect changes in the electric field and approaching lightning discharges. Depending on the intensity of the electric field or proximity of the lightning, the sensor provides an event indication via wireless communication to a receiving antenna and console unit which is positioned within 1 km line of sight of the sensor. Commercial in Confidence Document: 36 TD LWS MKIII.pub Version: 2.00 05/11/2008 Copyright 2008 LPI 2

Each sensor also contains an Alarm/Warning/All Clear Indication device. Depending on customer preference this is provided by a siren and/or an LED display, which allows the user to communicate situation events to all personnel in accordance with site safety policies and procedures. Depending on the layout of the site and the area to be monitored, LPI can customize a solution which uses multiple sensors in the field. The multiple sensor arrangement allows for a voting methodology to be engaged by the system, this uses results provided by individual sensors to determine the lightning risk. LPI can also provide a suitable Mounting Pole (OD 70mm, ID 61.5mm) to mount the LWS Sensor Assembly to. If the Mounting Pole option is included, suitable locking bolts are also provided to keep the LWS Sensor Assembly secure. Event Indication Levels As the LWS MkIII sensor detects lightning activity or increases in the electric field, event indications are made at the Sensor and are communicated to the Console for processing. If the event falls within a predetermined level, the following indications are provided to the user. Warning Indication A Warning Indication occurs when either a far lightning strike or a low electric field is detected. Far lightning strikes are defined as lightning events that occur within a radius of approximately 10 to 25km of the sensor. Low electric-field events are defined as being when the local electric field rises above a level of 4kV/m. A Warning status provides the user with an indication, that a storm is within a relatively close range and may move towards the area where the sensors are stationed. When a storm is within 25km it may arrive in the area in approximately 20-30 minutes. Figure 3: Warning Status at above 4kV/m Commercial in Confidence Document: 36 TD LWS MKIII.pub Version: 2.00 05/11/2008 Copyright 2008 LPI 3

Alarm Indication An Alarm Indication occurs when a near lightning strike or high electric field is detected. Near lightning strikes are defined as lightning events that occur within a radius of approximately 8 to 10km of the sensor, which are close enough to pose a significant risk within approximately 10-15 minutes. High electric field events are defined as being when the local electric field rises above 7kV/m. An Alarm status provides to the user an indication that current activities at site should be suspended, allowing shelter to be taken in accordance with established safety procedures. Figure 4: Warning Status at above 7kV/m All Clear Indication An All Clear Indication is given when no activity (far strikes, near strikes, low electric field or high electric field) has occurred within 15-30 minutes (programmable). After this period of no activity it is deemed safe to resume all activities. Commercial in Confidence Document: 36 TD LWS MKIII.pub Version: 2.00 05/11/2008 Copyright 2008 LPI 4

Applications The LPI LWS MKIII is suitable for use in all open areas where human traffic and / or sensitive operations are subjected to the threat of lightning strikes. In situations where large open areas covering many kilometres require monitoring, LPI s customized multiple sensor arrangement provides a high degree of accuracy in providing a safe working environment. Typical industry and recreational applications for the LPI LWS include: Mining sites including applications where explosives are used for blasting purposes Military Construction sites Airports Ship loading facilities Refuelling facilities Power generation Oil and Gas facilities Schools Theme Parks Open Air events such as festivals and concerts General outdoor recreational activities Horse Racing Tracks Golf Courses Sports Stadiums Rail and Transport Industrial Commercial in Confidence Document: 36 TD LWS MKIII.pub Version: 2.00 05/11/2008 Copyright 2008 LPI 5

Comprehensive Lightning and Surge Protection Solutions The LPI Lightning Warning System is only one aspect of the overall lightning protection strategy, required for comprehensive structural, personnel and equipment safety. The installation of LPI s LWS in conjunction with the following range of LPI products, ensures a complete solution to your lightning problems. Correctly installed direct strike protection systems such as the LPI Guardian and Stormaster range of air terminals, provides structural and area protection from direct lightning strikes. Surge and Transient protection products for powerline, shunt and series protection for applications in protecting power supply at the point of entry to your facility and protecting power supply to sensitive equipment. Surge and Transient protection products for data, communications and signal lines. A comprehensive range of earthing products and accessories for a low impedance earthing system. Commercial in Confidence Document: 36 TD LWS MKIII.pub Version: 2.00 05/11/2008 Copyright 2008 LPI 6

Technical Data LPI offers two alternative packages for the LWS MK III. Package A. 1 x Sensor and antenna assembly (6-12V DC Power Supply), console and siren. Package B. 1 x Sensor and antenna assembly, solar panel power supply for sensor, console and siren. Customized systems using multiple sensors can be configured to suit customer requirements, contact LPI or an authorised representative for a customized design. Ordering Code Description: Model: Control Console Box: Control: LWS-MKIII LPI Lightning Warning System LPI LWS MK III Die-Cast, 152mm (L) x 83mm (W) x 50mm(H) Micro Processor Controlled Interface: Webpage (default address 192.168.1.90) Operation: Relay Output: Weight: Colour: Power Supply: Wireless Frequency: Sensor Assembly Construction: Lightning Discharge Detection Range: Electric Field Measurement: Relay Output: Wireless Frequency: Colour: Weight: Power Supply: Console receives electrostatic field measurements and event notification from sensors in the field and displays received information on an easy to read webpage. Allows users to download and save a log of events that have occurred. Allows users to change a range of settings. 3 Outputs (All Clear, Warning and Alarm) 840g Grey 6V plug pack (110V/240V) 2.4GHz Stainless Steel Far Strike, Approximately 10-25km Near Strike, Less than approximately 10km Negligible, Approximately ± 0-4kV/m Low E-field, Approximately ± 4-7kV/m High E-field, Approximately ± 7-10kV/m 3 Outputs (All Clear, Warning and Alarm) 2.4 GHz Bare Stainless Steel 8kg Package A 12Vdc plug pack (110V/240V) Package B 12Vdc solar panel and storage battery Commercial in Confidence Document: 36 TD LWS MKIII.pub Version: 2.00 05/11/2008 Copyright 2008 LPI 7

Siren Siren Sound Output: Environment Rating: Mode of Operation: Colour: Approximately 106dB IP65 Primary alternating tone or secondary continuous tone White Input Voltage: 8-35V Supply Current: 11mA @ 26V Temperature Range: -30 to 50 ºC Weight: Solar Panel Voltage: Power: Size: Weight: Type: 154g 12 Volt 20 Watt 639mm x 294mm x 23mm 2.4kg Monocrystalline For Operation and Installation please refer to LWS MK III Installation and Operating Manual Lightning Protection International Pty Ltd operates a certified management system that complies with the requirements of AS/NZS ISO9001:2000. The scope of certification encompasses the design, manufacture, assembly, sales, installation and commissioning of lightning and surge protection equipment and earthing material. Commercial in Confidence Document: 36 TD LWS MKIII.pub Version: 2.00 05/11/2008 Copyright 2008 LPI 8