Bottom Mount Refrigerator Technical Information

Similar documents
CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10% Temperature Relationship Test Chart.

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

Bottom Mount Refrigerator---Technical Information

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

CAUTION. No-Load Performance, Controls in Normal Position

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

FOR SERVICE TECHNICIAN S USE ONLY

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY

Image Key Part Number Description Substitution Qty.

FOR SERVICE TECHNICIAN S USE ONLY

SERVICE NOTEBOOK BUILT-IN REFRIGERATOR VCSB481 / VCSB482

Image Key Part Number Description Substitution Qty.

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

Super-Flo Low Profile Unit Cooler

Container Refrigeration

Heat Pump Defrost Board Replacement Kit

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

JDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Undercounter Worktop Prep Table. hoshizakiamerica.com

LOW PROFILE UNIT COOLER

Technical Information- Dishwasher MDB8750AWB MDB8750AWQ MDB8750AWS MDB8750AWW MDB9750AWB MDB9750AWQ MDB9750AWS MDB9750AWW

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Service Documentation

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Hoshizaki America, Inc.

INSTALLATION INSTRUCTIONS

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.

Scotsman Technical Training. CU50 Cube Ice Machine

LOW PROFILE UNIT COOLER

Product Information and Technical Guide

GKv 5710 / 5760 GKv 6410 / 6460

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Product Information and Technical Guide

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Hoshizaki America, Inc.

MR3CCUHV Temperature/Defrost Control

APARTMENT MAINTENANCE SERIES

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

CAUTION. To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing. MDBTT50AW*

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

REACH-IN SAFETEMP (-AAC)

Model Number Nomemclature... 1 Specifications... 3 Refrigeration System... 4 Freezer and Refrigerator Air Circulation... 5 Display Designs...

Peachtree City is home office for America located about 30 miles south of the Atlanta airport this is were all KM cubers as well as Flakers are built.

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

Fast Track Troubleshooting

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool AC/DC and DC only Refrigerators and Freezers.

HP50HA ABG Heat Pump

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

-30 C Undercounter Plasma Freezer

Prodigy Flaked and Nugget Ice Machines Technical Review

Instruction Sheet

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Upright S-Series. hoshizakiamerica.com

Fast Track Troubleshooting

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

User Guide ems25plus. Page 1. Normal operation. Product interface

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

Product Information and Technical Guide

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

Ice Maker (Fresh Food Compartment)

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

Service Step by Step Trouble-Shooting Check-List

TECHNICAL SERVICE GUIDE

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

MODEL URS-1: FACTORY RETROFIT PROGRAM

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

ERC2 Control Instructions

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

IKS..10,..20 / IK..00 / EK..10 from Index 20. IKS..14,..24 / IK..04 / EK..14 from Index 20, with 4-star freezer compartment

Hoshizaki America, Inc.

40KMC KMQ

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

REF5-BB Undercounter Blood Bank Refrigerator

rlrm MOflel S DE-BY-SIDE REFRIGERATOR Always consult the Use & Care Guide for more operating information.

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

Jr. Tech (JT-1, 2, 3) Knowledge Areas

Installation and Operation Guide For

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

Product Information and Technical Guide

KM-630MAH KM-630MWH KM-630MRH

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SERVICE MANUAL IMPORTANT IMPORTANT 4SCU20LX 4SHP20LX ALLIED AIR ENTERPRISES I. GENERAL. August Electrical

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

KM-61BAH KM-101BAH KM-151BAH

Transcription:

Bottom Mount Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTIN All safety information must be followed as provided in ervice Manual 1602629. servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before handling. Wires Kw/2 hr ±0. No-Load Performance, Controls in Normal Position Percent Run Time ±10% Cycles/2 hr ±2% Center Compartment Average Food Temperature ±3 F Compartment Average Food Temperature ±3 F Ambient F 70 90 110 70 90 110 70 90 110 70 90 110 70 90 110 2 cu ft 1.0 1.60 2.3 28 8 6 3 39 2 38 36 3 0 0 0 Evaporator utlet ±3 F Evaporator Inlet ±3 F Temperature Relationship Test Chart uction Line ±7 F Average Total Wattage ±10% uction Pressure ±2 PIG Head Pressure ± PIG Ambient F 70 90 70 90 70 90 70 90 70 90 70 90 2 cu ft -20-17 -20-17 8 10 13 10 6"(Vac.) 0 87 137 chematic March 2006 1 1282792

Component pecifications Component Compressor run capacitor pecifications all parts 11VAC/60HZ unless noted Volt... Capacitance... Compressor BTUH... Watt... Current Lock rotor... Current Full load... Resistance Run windings... Resistance tart windings... Electric damper control Maximum closing time... Temperature Rating... RPM... Thermistor Temperature 77 F... 36 F... 0 F... Condenser motor Evaporator ECM fan motor Evaporator fan motor Rotation (facing end opposite shaft) RPM Watt... Current... Rotation (facing end opposite shaft) RPM Watt. Rotation (facing end opposite shaft) RPM Watt. verload/relay Ult. trip amps @ 18 F (70 C)... Close temperature... pen temperature... hort time trip (seconds)... hort time trip (amps @77 F (2 C).. Control board Volt... ee Control Board section for diagnostics Thermostat (Defrost) Volt... Watt... Current... Resistance across terminals: Above 2 F ±... Below 12 F ±7... Evaporator heater Volt... Wattage... Resistance... Mullion Assembly w/ Heater Water valve, dual Light switch Light switch / Interlock Energy aver switch Volt Wattage... Resistance... Volt... Watt... Type.. Volt Current.. 220 VAC 1 fd 10% 730 BTUH 60 Hz / 12 watts 19.0 amps± 1% 1.09 amps± 1% 3.33 ohms± 1%.28 ohms± 1% 8 seconds 20 F- 110 F Resistance 10,000 ohms 29,00 ohms 86,300 ohms Clockwise 1120 RPM 3.0 watts±1%@11vac 0.08 amps± 1%@11VAC Clockwise 290 RPM.6 ±1% watts@11vac Clockwise 2800 RPM 6.0 ±1% watts@11vac 2.0 amps± 1% 10 F ±10 230 F ± 12 seconds ± 17 amps ±2amps 120VAC, 60 HZ 120/20 VAC 9 watts 10/ amps pen Closed 11 VAC 70 ±% watts @ 11VAC 29 ±% ohms 120 VAC 10±. watts @ 120VAC 10 ±% ohms Resistance checked at leads at center of hinged side of Fresh Food door. 120 VAC 3 watts (Brown coil) 20 watts (Yellow coil) PT NC 12/20 VAC 8 / 6 amps Type.. PDT N/NC Volt 12/20 VAC Current.. / 2. amps Type.. Volt Current.. PT N 12/20 VAC 16 / 8 amps March 2006 2 1282792

ervice pecifications Programming Mode: Note: The Program Code is located on the erial Plate on this unit after the word Code. 1. pen the Fresh Food door and hold the Fresh Food door light switch closed while pushing the Temperature Down Key pad 3 times consecutively. Note: The 3 Keystrokes must be done consecutively and within 10 seconds. 2. Release the Fresh Food door light switch. 3. The control will display PE to confirm entry into the programming mode. P. Entry is confirmed by pressing the Down key once more. Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will remain in its current position).. The control will display the current Program Code. This value should be validated with the Program Code printed on the unit serial plate. 2 March 2006 3 1282792 E Note: If the Program Code is correct, the Programming Mode is exited by closing the door(s). 6. To set the desired Program Code number press the and Up keys. The corresponding digit will be advanced with each key press. 7. nce the desired Program Code is displayed, press the Down Key until the Program Code begins flashing indicating it has been saved. Note: If you attempt to enter an invalid Program Code the control will not save the new code, but will flash the old code and this will be displayed. (The unit will NT run with a Program Code of 00). 8. nce the Program Code has been saved the Programming Mode is exited by closing the door(s). If the new code is incorrect this process should be repeated after closing the door(s). The Programming mode can be exited at any time by closing the Door(s). Defrost peration: The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by monitoring the length of time the defrost heater is on. After initial power up, defrost interval is hours compressor run time. Defrost occurs immediately after the hours. Note: nce unit is ready to defrost there is a minute wait time prior to the beginning of the defrost cycle. ptimum defrost is 1 minutes. Each additional minute the defrost thermostat remains closed, 1 hr. is subtracted from the previous defrost interval. Each minute the thermostat opens prior to optimum defrost, it extends the next defrost interval 1 hr. When defrost thermostat opens there is a -6 minute drip time before compressor restarts or Control Board will terminate defrost at 2 minutes if defrost thermostat has not opened and will reset the defrost interval to the 8 hr. minimum setting. hours of continuous compressor run resets the next defrost interval to 8 hours and will initiate a defrost, if 8 hours of compressor run time has also occurred. Forced Defrost Mode: Power up Refrigeration mode will occur unless both the cold control and defrost terminator are open, in that case the defrost mode will occur for 2 minutes. The forced defrost function is performed using the refrigerator display and keypad. Enter the Forced Defrost Mode by performing the following sequence of events: 1. Hold the refrigerator door light switch closed. 2. Press the Temperature Down keypad 3 times consecutively. Note: The 3 keystrokes must be consecutive and within 10 seconds.

ervice pecifications 3. Release the refrigerator door light switch.. The control will display Fd to confirm entry into the Forced Defrost Mode. F. Entry is confirmed by pressing the Down key once more. The unit is off and in the Defrost Mode. Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will remain in its current position). 6. The control will default to the short run period test as shown here: Note: You can toggle between the ()hort and (L)ong test mode by pressing the Up Long Test mode is used for factory test and should not be used in the field. 7. nce the desired mode is displayed, confirm the forced defrost by pressing the Down Key once. The defrost will begin immediately and the display will return to a normal operating display with set point values. L 8. Close the door(s). You are in the defrost mode. Note: Forced Defrost mode can be exited at any time prior to step 7 by closing the Door(s). ervice Test Mode: The service test functions are performed using the refrigerator display and keypad. Enter the ervice Test Mode by performing the following sequence of events: 1. Hold the refrigerator door light switch closed. 2. Press the Temperature Up keypad 3 times consecutively. Note: The 3 Keystrokes must be done consecutively and within 10 seconds. 3. Release the refrigerator door light switch.. The control will display E to confirm entry into the service mode.. Entry to the ervice Menu is confirmed by pressing the Up key once more. 6. The control will display its software version for 3 seconds. 2 E 7. Following the software revision display the freezer display will read the first test number in the diagnostic tree. The refrigerator display will be blank. 1 Note: All control functions will be turned off (Compressor, Defrost, Evaporator Fan, the damper will remain in its current position). 8. You are now in the ERVICE TET operational mode and may use the diagnostic tests. The ervice Test Mode can be exited at any time by closing the Door(s). Key. March 2006 1282792

ervice pecifications ervice Test 1 Defrost Thermostat & Defrost Circuit Test When selected this test will display the state of the defrost thermostat. In order to perform this test the defrost heater will be energized. The test is activated and deactivated using the Up key. nce activated, this test must be deactivated to move to another test number. The Up / Down keys allow selection of the test to be performed. This test also allows observation and measurement of proper defrost function. You can observe defrost heat and voltages while the test is activated. 1 DEFRT THERMTAT PEN 1 DEFRT THERMTAT HRTED (CLED) ervice Test 2 Compressor/Condenser Fan Test When selected and activated this test will operate the Compressor/Condenser Fan circuit. You should evaluate proper operation of the compressor and condenser fan. The Up key will toggle between / F (N & FF) the compressor drive circuit. The test must be deactivated or in the FF position to move to another test selection. 2 2 BERVE CMPRER & CNDENER FAN FUNCTIN ervice Test 3 Evaporator/ Fan Test When selected and activated this test will operate the freezer fan. The Up key will toggle between / F (N & FF) the fan drive circuit. You will have to inspect the fan for proper function. The test must be deactivated or in the FF position to move to another test selection. 3 3 F F BERVE FAN PERATIN March 2006 1282792

ervice pecifications ervice Test Fresh Food Thermistor Test When selected and activated this test will display Pass, pen, hort result for a test on the Fresh Food Thermistor circuit as shown below. The test is activated and deactivated via the Up key, and must be deactivated to move to another test selection. PA REULT PEN REULT P HRT REULT ervice Test Thermistor Test When selected this test will display Pass, pen, hort result for a test on the Thermistor circuit as shown below. The test is activated and deactivated via the Up key, and must be deactivated to move to another test selection. PA REULT PEN REULT P HRT REULT March 2006 6 1282792

ervice pecifications ervice Test 6 pen Damper Test When selected this test will indicate the current position / C (PEN / CLED) of the refrigerator damper. The Up key will toggle the damper open and closed. You must allow 1 minute for each attempt to change the damper position. You should observe proper damper function. 6 6 March 2006 7 1282792 C BERVE DAMPER FUNCTIN! CAUTIN Adjustments of ervice Test 7 or ervice Test 8 will alter the performance of the unit. ervice Test 7 FF Performance Adjustment This test will allow adjustment of the control performance points. Each step will incrementally change the performance warmer (towards 1) or colder (towards 9) as adjusted. The default value is. The refrigerator / Up/Down keys are used to adjust the Performance ffset value. WARMER (1 2 3 () 6 7 8 9) CLDER. 7 7 DEFAULT CLDER The last FF Performance ffset value displayed before leaving test 7 will be saved when the refrigerator door(s) is closed. ervice Test 8 FZ Performance Adjustment This test will allow the adjustment of the control performance points. Each step will incrementally change the performance warmer (towards 1) or colder (towards 9) as adjusted. The default value is. The refrigerator / Up/Down keys are used to adjust the Performance ffset value. WARMER (1 2 3 () 6 7 8 9) CLDER. 8 8 DEFAULT 6 WARMER The last FZ Performance ffset value displayed before leaving test 8 will be saved when the refrigerator door(s) is closed.

Wiring Diagram ee Note below about alternate wiring of door harness Note: When energy switch is in the ff position the fresh food mullion heater is energized and when the energy switch is in the n position the fresh food mullion heater is not powered. To avoid moisture from condensing on the fresh food mullion the energy switch should always be in the ff position. Note: In the event of excessive moisture on fresh food door mullion, the red and blue cabinet wires to door harness can be reversed to power fresh food door mullion heater continuously. This will help to reduce moisture on fresh food door mullion. ee wiring alternate above for wiring in mullion heater for continuous operation. When powered continuously Energy witch is no longer in heater circuit. March 2006 8 1282792