CLEANING INSTRUCTIONS

Similar documents
Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Instructions for Use Spinal Punches IFU

RECOMMENDATIONS FOR CLEANING DEVICES

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

Recommendations for cleaning, decontamination and sterilisation. devices

Cleaning & Sterilization

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Operating / User Manual

When you sterilize an instrument set, you know what the standards are.

Aesculap Implant Systems

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

STERITITE INSTRUCTIONS FOR USE

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

RAP-hip Hip stem extraction set

Aesculap Implant Systems

FLASH PAK STERILIZATION CONTAINER SYSTEM

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Reprocessing Instructions for Reusable Surgical Instruments English

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

V. Mueller. V. Mueller Reusable Devices: Cleaning and Sterilization Guide USA. Rx Only

Processing instructions for the Ligamys suture forceps

I.F.U Re/Processing Reusable Medical Devices

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

2015 Myco Industries, Inc Fax:

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

THE BASICS OF DECONTAMINATION

Reprocessing Instructions for Reusable Surgical Instruments English

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

Cleaning and Sterilisation for Burs, accessories and filling material

PERFORM Operating Document

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Important information

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

Cleaning and Sterilization for Instruments & Posts

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

Fiona Collins Liliana Donatelli Andrew Smith

Processing Instructions. Cleaning so easy.

Classification of Instruments -

Reusable Laryngoscope Blades and Handles

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Operator s Manual. Video Laryngoscope. ( Instructions for use ) Doc no: Revision 1.1 8th January 2013

SteriTite - The Container System of Choice SteriTite

Instructions for Use: Fiberscope and LED Light Source

Instructions for Use: Endoplus Modular Handle Assemblies, Multi-Use Scissors Inserts, Reusable Inserts

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

Do not attempt to adjust or disengage the spring on the handle.

SteriTite - The Container System of Choice SteriTite

idrive Ultra Powered Stapling System

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

User s Manual. Small Electric Drive. Compact and powerful system for use in hand and foot surgery.

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

MARSHALLTOWN MEDICAL AND SURGICAL CENTER ENVIRONMENTAL SERVICES. SUBJECT: Room Cleaning Occupied Room (All Areas) PROCEDURE NO: 032

Additionally, consider the legal provisions valid for your country as well as to the hygienic instructions of the doctor s practice or hospital.

DRAFT. Module 4. Decontamination & Environmental Cleaning

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

ComPact Air Drive II USER S MANUAL

CODE OF PRACTICE. No 11 CLEANING OF EQUIPMENT AND PREMISES

CLEANING OF INSTRUMENTS

Decontamination. CIS Self-Study Lesson Plan Lesson No. CIS 244 (Instrument Continuing Education - ICE)

Air-driven Universal Power Tool System for Traumatology, Endoprosthetics, and Spine. Compact Air Drive II. Instructions for Use

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

Visao HIGH-SPEED OTOLOGIC DRILL CATALOG

Washroom. PURPOSE: To provide clean washrooms for staff, visitors and patients MATERIALS: 19-1

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

HOMES AND SENIORS SERVICES. APPROVAL DATE: April 2004 REVISION DATE: March 2016 REVISION DATE: March 2017 REVIEW DATE: November 2018

Always ensure that surfaces that are being disinfected are compatible with the product being used.

Central Sterile Services Department will receive, decontaminate, process, store and/or dispense sterile and non-sterile to departments requesting.

H5i disinfection guide

Technical Data Monograph. Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America)

Harvey Chemiclave 5000 Owner And Operator Guide

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

Instructions for Use and Reprocessing Instructions

The Principles, The Process, and The Results:

DEVICES THAT HAVE NOT BEEN ADEQUATELY CLEANED CANNOT

Transcription:

Reusable Instrument Care Manual Pagoda Pedicle Screw System Manufacturer Ortho Development Corporation 12187 South Business Park Drive Draper, UT 84020 Phone 801-553-9991 Fax 801-553-9993 www.orthodevelopment.com INSTRUMENT CARE Considerations This guide includes processing instructions for all Ortho Development (ODEV) reusable devices. All ODEV devices may be safely and efficiently reprocessed using either manual or combination manual/automated cleaning instructions outlined. New and used instruments must be thoroughly cleaned per these instructions prior to sterilization and use. Warnings and Precautions Universal precautions should be observed by all hospital personnel that work with contaminated medical devices. Caution should be exercised when handling devices with cutting edges or sharp points. Personal protective equipment (PPE) should be worn when handling or working with contaminated or potentially contaminated devices. PPE includes gown, mask, goggles or face shield, gloves, and shoe covers. Do not place heavy instruments on top of more delicate instruments. Do NOT use metal brushes or scouring pads during manual cleaning. These will damage the surface and finish of instruments. Only soft-bristled, nylon brushes and pipe cleaners should be used. Do NOT allow contaminated devices to dry prior to reprocessing. All subsequent cleaning is facilitated by not allowing blood, body fluid, bone and tissue debris, saline or disinfectants to dry on used devices. Saline, and cleaning/disinfection agents containing active chlorine, aldehyde, bromide, bromine, chloride, mercury, iodine or iodide are corrosive and should NOT be used. Mineral oil or silicone lubricants should not be used because they are difficult to remove, prevent direct contact of the surface with steam during sterilization, and coat microorganisms. Limitations and Restrictions Automated cleaning using a washer/disinfector alone may not be effective for cleaning orthopedic instruments. A thorough manual or combination manual/automated cleaning process is recommended. Neutral ph enzymatic and cleaning agents are recommended. Instrument trays, cases, and lids must be cleaned separately. Non-sterile, single use implants are an exception as they may remain in the tray or caddy for reprocessing. Repeated processing has minimal effect on ODEV reusable instruments unless otherwise noted. End of life for stainless steel or other metal surgical instruments is normally determined by wear and damage due to the intended use and not reprocessing. Use of hard water should be avoided. Softened tap water may be used for initial rinsing. Reverse Osmosis (RO) or Deionized (DI) water should be used for final rinsing of the instruments. CLEANING INSTRUCTIONS Point of Use Remove excess body fluids and tissue from instruments with a disposable, non-shedding wipe. Place devices in a tray of distilled water or cover with damp towels. Instruments should be cleaned within 30 minutes of use to minimize the potential for drying prior to cleaning. Used instruments must be transported to the central supply in closed or covered containers to prevent unnecessary contamination risk.

Preparation Before Cleaning Disassemble the following instruments for cleaning 852-0031 Screw Inserter Sleeve 852-0032 Polyaxial Screw Inserter 852-0033 Polyaxial Reduction Screw Inserter 852-0034 Monoaxial Screw Inserter 852-0036 Inline Grip Rod Persuader 852-0041 TLIF Distractor Individual disassembling instructions 852-0032 Polyaxial Screw Inserter, 852-0033 Polyaxial Reduction Screw Inserter, 852-0034 Monoaxial Screw Inserter For easier disassembly, attach the Ratchet T-Handle (852-0002) to the Screw Inserter (852-0032, 852-0033, or 852-0034). While firmly gripping the T-Handle, pull apart the outer sleeve or knob of the Screw Inserter Sleeve (852-0031) from the Screw Inserter (inner shaft). 852-0036 Inline Grip Rod Persuader Press thumb button and finger latch simultaneously to slide reducer body to top of tower. Press lateral button marked Press to clean and pull reducer body upwards to disengage from tower. Align arrows to reassembly reducer body with tower. 852-0041 TLIF Distractor Press latch and pull to disassemble sliding arm from rack. All cleaning agents should be prepared according to the manufacturer. Softened tap water may be used to prepare cleaning agents. Use of manufacturer recommended temperatures is important for optimal performance of the cleaning agents. NOTE: Fresh cleaning solutions should be prepared when the existing solutions become grossly contaminated (turbid and/or bloody). Table 1: Cleaning/Disinfection Options Method Manual (Table 2) Combination Manual/Automated (Table 3) Automated (washer/disinfector) Description Enzymatic soak and scrub followed by sonication. Enzymatic soak and scrub followed by an automated washer/disinfector cycle. Automated cycle - Not recommended without manual pre-cleaning. Manual Cleaning/Disinfection Procedure Table 2: Manual Cleaning Steps Use a lint-free cloth dampened in tap water to remove gross soil. While wiping, actuate the instrument(s) through the full range of motion. water. Fully immerse the instruments in the detergent and soak for a minimum of 20 minutes. While soaking, the instrument(s) should be actuated to ensure complete penetration of the detergent. Using a soft bristled brush (e.g. M16) and as necessary, lumen brushes (e.g. 45-541, 45-545), remove all visible soil paying attention to crevices and hard to reach areas. Rinse the instrument(s) under running RO/DI water for a minimum of 3 minutes to remove detergent residue. While rinsing actuate the instrument through its/their full range of motion.

Step 5 Step 6 Step 7 water in an ultrasonic cleaner. Fully immerse the instrument(s) and sonicate for a minimum of 10 minutes. Rinse the instrument(s) under running RO/DI water for a minimum of 5 minutes to remove all evidence of detergent residue. While rinsing actuate the instrument through its/their full range of motion. Visually inspect the instrument for soil. Dry using a clean, soft cloth and filtered pressurized air Step 8 (<40psi). If soil is visible, repeat the process. NOTE: Use of a sonicator at 45-50 khz will aid in thorough cleaning of the devices. NOTE: Use of a syringe or water jet will improve flushing of difficult to reach areas and closely mated surfaces. Table 3: Combination Manual/Automated Cleaning Steps Step 5 Step 6 Step 7 Step 8 Use a lint-free cloth dampened in tap water to remove gross soil. Actuate the instrument(s) through the full range of motion. water. Fully immerse the instruments(s) in the detergent and soak for a minimum of 20 minutes. While soaking, the instrument(s) should be actuated to ensure complete penetration of the detergent. Using a soft bristled brush (e.g. M16), remove all visible soil paying attention to crevices and hard-to-reach areas. Rinse the instrument(s) under running RO/DI water for a minimum of 3 minutes to remove detergent residue. While rinsing actuate the instrument(s) through its/their full range of motion. water in an ultrasonic cleaner. Fully immerse the instrument(s) and sonicate for a minimum of 10 minutes. Rinse the instrument(s) under running RO/DI water for a minimum of 5 minutes to remove all evidence of detergent residue. While rinsing actuate the instrument(s) through its/their full range of motion. Place instrument(s) into the associated tray, then place into a washer/disinfector with the cover and upper tray(s) separate from the lower tray and main case. Step 9 Remove from the washer and visually inspect for visible soil. If soil is visible, repeat the process. NOTE: Use of a sonicator at 45-50 khz will aid in thorough cleaning of the devices. NOTE: Use of a syringe or water jet will improve flushing of difficult to reach areas and closely mated surfaces. Table 4: Recommended Automated Washer/Disinfector Cycle Steps Step 5 Pre-Wash; Cold Softened Tap Water; 1 minute Enzyme Wash; Hot Softened Tap Water; 1 minute Detergent Wash; Hot Softened Tap Water (66 C set point); 2 minutes Rinse; Hot Softened Tap Water; 1 minute Hot Air Dry (115 C); 7 minutes Inspection, Maintenance and Testing Carefully inspect each device to ensure all visible contamination has been removed. If contamination is noted, repeat the cleaning/disinfection process. Check the action of moving parts to ensure smooth operation throughout the full range of motion. Hinged, rotating or articulating instruments should be lubricated with a water soluble product intended for surgical instruments that must be sterilized. Some water-based instrument lubricants contain bacteriostatic agents which are beneficial. Manufacturer s expiration dates should be adhered to for both stock and use-dilution concentrations.

STERILIZATION INSTRUCTIONS All instruments should be thoroughly cleaned prior to sterilization. Cases should be placed in two layers of FDA cleared 1-ply polypropylene wrap, such as Kimguard KC600, using sequential wrapping techniques prior to sterilization. NOTE: Areas designated for specific instruments shall contain only instruments specifically intended for these areas. NOTE: These validated reprocessing instructions are not applicable to Ortho Development trays that include devices that are not manufactured and/or distributed by Ortho Development. Instrument trays and cases without defined, preconfigured layouts or containing undefined universal spaces or compartments should only be used under the following conditions: 1. All devices must be arranged to ensure steam penetration to all instrument surfaces. Instruments should not be stacked or placed in close contact. 2. The user must ensure that the instrument case is not tipped or the contents shifted once the instruments are arranged in the case. Silicone mats may be used to keep instruments in place. 3. Only instruments manufactured and/or distributed by Ortho Development should be included in Ortho Development instrument trays. Ortho Development validated reprocessing instructions are not applicable to Ortho Development trays that include devices that are not manufactured and/or distributed by Ortho Development. Sterilization Disinfection is only acceptable as a precursor to full sterilization for reusable surgical instruments. Refer to the table below for recommended minimum sterilization parameters that have been validated by Ortho Development to provide a 10-6 sterility assurance level (SAL). The hospital is responsible for in-house procedures for the reassembly, inspection and packaging of the instruments after they are thoroughly cleaned in a manner that will ensure steam sterilization penetration and adequate drying. Provisions for protection of any sharp or potentially dangerous areas of the instruments should also be recommended by the hospital. Moist heat/steam sterilization is the preferred and recommended method for Ortho Development orthopedic instrument sets. Sterilizer manufacturer recommendations should always be followed. When sterilizing multiple instrument sets in one sterilization cycle, ensure that the manufacturer s maximum load is not exceeded. Instrument sets should be properly prepared and packaged in trays and/or cases that will allow steam to penetrate and make direct contact with all surfaces. Gravity displacement sterilization cycles are not recommended because cycle times are too long to be practical. However, they will be provided upon request. Storage Sterile, packaged instruments should be stored in a designated, limited access area that is well ventilated and provides protection from dust, moisture, insects, vermin, and temperature/humidity extremes. Hospital Responsibilities for Ortho Development Loaner Instruments Orthopedic instruments generally have a long service life; however, mishandling or inadequate protection can quickly diminish their life expectancy. Instruments which no longer perform properly because of long use, mishandling, or improper case should be returned to Ortho Development to be discarded. Notify your Ortho Development representative of any instrument problems. Loaner sets should undergo all steps of decontamination, cleaning, disinfection, inspection, and terminal sterilization before being returned to Ortho Development. Documentation of decontamination should be provided with instruments being returned to Ortho Development.

All instruments should be thoroughly cleaned prior to sterilization. The following Steam Sterilization Cycles must be followed to ensure sterility: Implants Temperature Cycle Time (minutes) Dry Time (minutes) Prevacuum 132º C (270º F) 4 45 Instruments Prevacuum 132º C (270º F) 4 60 Important Notice The instructions provided have been validated by Ortho Development as being capable of preparing orthopedic instruments for use. It is the responsibility of the hospital to ensure that the reprocessing is performed using the appropriate equipment and materials and the personnel in the reprocessing facility have been adequately trained in order to achieve the desired result. Equipment and processes should be validated and routinely monitored. Any deviation by the processor from these instructions should be properly evaluated for effectiveness to avoid potential adverse consequences. 351-1-10704 01/2014