HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Similar documents
Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Overview of Hazardous Locations as They Relate to Solenoid Valves

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

[ TECHNOLOGY ] and does this definition affect a burner.

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper. Calibration in hazardous areas

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

ATEX, NOMENCLATURE AND CODING

INTERNATIONAL STANDARD

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Explosion protection Marijan Gorše, dipl. ing.

OPTIBAR DP 7060 Supplementary Instructions

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Guide for hazardous areas

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

ATEX, NOMENCLATURE AND CODING

1. GENERAL TECHNICAL INFORMATION

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

ELECTRICAL SAFETY Information Bulletin

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

August Process Industry Practices Electrical. PIP ELEHA01 Engineering Guide for Determining Electrical Area Classification

Official Journal of the European Union

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Introduction to Hazardous Electrical Location Classifications

Official Journal of the European Union

Electrical Installations Design, Selection, Erection and Inspection

ELECTRICAL SAFETY Information Bulletin

Survey of electrical equipment installed in hazardous areas on tankers

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

ATEX Safety Switches. More than safety.

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

ESSENTIAL EXPLOSION PROTECTION

ELECTRICAL SAFETY Information Bulletin

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

C 319/6 Official Journal of the European Union

Area Classification and Types of Protection for Explosive Atmospheres: A Review

Desiccant. Breather Range

Guide to Explosion Protection and Plant Safety

Explosion-protected actuator Page 259 of 292

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

This document is a preview generated by EVS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

UL HAZARDOUS LOCATIONS SERVICES

Fire is No Accident Fire is No Accident It can be prevented.

CLASS I LOCATIONS ZONE CLASSIFICATION

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

ATM Lighting sp. z o.o

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

NCS/SAS IAS/PES Chapter Seminar January 25-27, Hazardous Locations. OBIEC Consulting George Morlidge Fluor Canada

OPTIWAVE X500 Supplementary Instructions

Handling Petroleum Products & Static Ignition Hazards Introduction

Dual certification! Air handling units for potentially explosive atmospheres

DuPont Formacel Z-2. Safety and Handling of DuPont Formacel Z-2: Thermoplastic* Foam Extrusion Applications FOAM EXPANSION AGENT TECHNICAL INFORMATION

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02)

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Smoke detection in hazardous areas:

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

ATM Lighting sp. z o.o

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IRceL CH4 Methane (CH 4

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Combustible Dusts What do I do???

ESSENTIAL EXPLOSION PROTECTION

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Aluminum Dust Management in a Metallizing Facility

MICROpeL 75 Combustible Gas Sensor Part Number: PM

CCTV Portfolio. Phoenix Explosion-proof Range

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

OPTIBAR P 1010/2010 C Supplementary instructions

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli


24V-Ex Power Supply INTRINSICALLY SAFE

Numerical Standards Listing

Transcription:

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT Olof Bekker Pr. Eng. BSc. Eng. BML S.MSAIEE, M.NACE Engineering Manager, Electrical

COMMITMENT 1

THE FIRE TRIANGLE For an explosion/fire to take place there must be 3 elements present, namely: - FUEL Liquid, gas or vapour/mist of flammable mixtures IGNITION SOURCE - flames, sparks, friction, lightning, static or heat. OXYGEN - air, oxidising agent or chlorine FUEL IGNITION SOURCE OXYGEN 2

Prevention of Explosion Prevention of the formation of explosive atmospheres Explosion confinement Avoidance of ignition of explosive atmospheres Ignition source isolation Reduction of the effects of an explosion Energy-release release limitation 3

FLAMMABLE EXPLOSIVE RANGE The range of flammable vapour or gas -air mixture between the LEL and HEL also known as the "explosive range" Measured in concentrations of % Volume in air. HEL/UEL % VOLUME IN AIR UPPER FLAMMABLE LIMIT (Too rich) FLAMMABLE LIMIT. IDEAL MIXTURE OF VAPOUR WITH OXYGEN LEL LOWER FLAMMABLE LIMIT (too Lean) LIQUID e.g. Hydrogen has a LEL of 4% and a HEL/UEL of 77% 4

HAZARDOUS AREAS A Hazardous area is an area in which an explosive gas atmosphere is present, or likely to be present, in quantities such as to require special precautions for the construction, installation and use of electrical apparatus in order to remove eliminate or mitigate the risk of an explosion or fire. Hazardous Area Classification is the method of analysing and classifying the environment where explosive gas atmospheres may occur in order to facilitate the selection of suitable electrical apparatus to be installed in that environment. 5

HAZARDOUS AREA CLASSIFICATION ENCOMPASSES: The nature of the flammable substances and the probability that the flammable substances can cause an explosion or fire, i.e. gas/vapour mist. Area detailed plot plan to be marked up. Source of release: Flange, pump seal, vent, open drain etc. Grade of release: Continuous, Primary, Secondary. Fluid Category: Category A, B, and C. Ventilation: Open, Sheltered, Enclosed, Artificially ventilated. Apparatus Group: Gas group 2A, 2B, and 2C Temperature Class : T1.T6 Auto ignition Temp: For determination of temperature class. Flashpoint: For determination of fluid category. Boiling range Process temp Process pressure Product density: Lighter/heavier than air. 6

HAZARDOUS AREA ZONES LIQUID, GAS, VAPOURS, MISTS Zone 0 is an area where an explosive mixture of flammable gas, vapour or suspended liquid droplets/mist with air is continuously present, or present for long periods. Zone 1 is an area where an explosive mixture of flammable gas, vapour or suspended liquid droplets/mist with air is likely to occur during normal operation. Zone 2 is an area where an explosive mixture of flammable gas, vapour or suspended liquid droplets/mist with air is likely to occur under abnormal operating condition of the facilities. Non-hazardous/safe area- are those where an explosive gas-air mixture shall not occur during normal and design emergency conditions (but, however, may occur during a catastrophic situation). 7

HAZARDOUS AREA ZONES DUSTS Zone 20 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, or for long periods, or frequently. Zone 21 The atmosphere is likely to contain ignitable concentrations of inflammable dust or fibres under normal working conditions. Zone 22 The atmosphere is not likely to contain suspended ignitable dust or fibres but such dust or fibres stored. (Silos, stores) 8

Continuous Grade GRADES OF RELEASE Vapour space above: closed process vessels, storage tanks, closed containers, areas containing open tanks of volatile, flammable liquid Primary Grade Flammable gas or vapour concentration is likely to exist in the air under normal operating conditions. Flammable atmospheric concentration is likely to occur frequently because of maintenance, repairs or leakage. Flammable liquid or vapour piping system (containing valves, meters, or screwed or flanged fittings) is in an inadequately ventilated area. The area below the surrounding elevation or grade is such that flammable liquids or vapour may accumulate therein. Secondary Grade The system handling flammable liquid or vapour is in an adequately ventilated area and is so designed and operated that the explosive or ignitable liquids, Vapour or gases will normally be confined within closed containers or closed systems from which they can escape only during abnormal conditions such as accidental release of a gasket or packing. The flammable vapours can be conducted to the location as through trenches, pipes or ducts Locations adjacent to Zone 1 areas. Pressurized rooms where flammable gas / vapour can enter in the case of failure of positive mechanical ventilation. 9

FLUID CATEGORY FLUID CATEGORY DESCRIPTION A A flammable liquid that on release would vaporize rapidly and substantially. This category includes: a) Any liquefied petroleum gas or lighter flammable liquid. b) Any flammable liquid at a temperature sufficient to produce on release more than about 40% volume vapourisation with no heat input from other than from the surroundings. B C G (i) A flammable liquid not in Category A but which can be at sufficient temperature for boiling to occur on release. A flammable liquid not in categories A or B but which can on release be at a temperature above its flash point or form a flammable mist or spray. A typical methane-rich gas. G (i) Refinery hydrogen. Unclassified Heavy oils etc. with flash point greater than 100 handled at a temperature below flash point which will not form a mist or spray on release. 10

VENTILATION Is the movement of air and its replacement with fresh air due to the effects of wind, temperature gradients, or artificial means (for example, fans or extractors) Ventilation can be accomplished by the movement of air due to the wind and/or by temperature gradients or by artificial means such as fans. So two main types of ventilation are thus recognized: a) natural ventilation; b) artificial ventilation, general or local. Ventilation could serve to reduce the extent of a hazardous location could so affect the frequency and duration of the flammable atmosphere that a reduced zone could be allocated. The latter effect is applicable to the division of hazardous locations into zones, and is discussed in detail in SANS 10119. 11

Ventilation table as per: SANS IEC 60079-10:2002 Table B.1 Influence of ventilation on type of zone. Ventilation Grade of Release Degree High Medium Low Availability Good Fair Poor Good Fair Poor Good Fair or Poor Continuous (Zone 0 NE) Non-hazardous (a) (Zone 0 NE) Zone 2 (a) (Zone 0 NE) Zone 1 (a) Zone 2 Zone 0 + Zone 2 Zone 0 + Zone 1 Zone 0 Primary (Zone 1 NE) Non-hazardous (a) (Zone 1 NE) Zone 2 (a) (Zone 2 NE) Zone 2 (a) Zone 1 Zone 1 + Zone 2 Zone 2 + Zone 2 Zone 1 or Zone 0 (c) Secondary (Zone 2 NE) Non-hazardous (a) (Zone 2 NE) Non-hazardous (a) Zone 2 Zone 2 Zone 2 Zone 2 Zone 1 And even Zone 0 (c) NOTE + signifies surrounded by (a) Zone 0 NE, 1 NE or 2 NE indicates a theoretical zone which would be of negligible extent under normal conditions. (b) The Zone 2 area created by a secondary grade of release may exceed that attributable to a primary or continuous grade of release; in this case the greater distance should be taken. (c) Will be Zone 0 if the ventilation is so weak and the release is such that in practice an explosive gas atmosphere exists virtually continuously (i.e. approaching a no ventilation condition) 12

APPARATUS GROUP/GAS GROUPS Gases are grouped together according to their degree of hazard. This is based on the amount of energy required to light the gas/air mixture. Gas Group I (mining) IIA (Surface) IIB (Surface) IIC (Surface) Representative Gas Methane Propane Ethylene Hydrogen 13

TEMPERATURE CLASS This relates to the maximum surface temperature of a piece of apparatus to the ignition temperature of a gas. (refer to - SANS 10108 ) T Class Max surface temp. T1-450 C T2-300 C T3-200 C T4-135 C T5-100 C T6-85 C 14

AUTO IGNITION TEMPERATURE The amount of energy necessary to ignite flammable gases Is the minimum temperature necessary to initiate combustion and have self sustained combustion of the solid, liquid, gas or vapour. Temperature above which spontaneous combustion can occur without the use of a spark or flame. 15

FLASH POINT HEL Too Rich Vapor Pressure % In Air LEL Too Lean Flash Point Temperature -> Lowest temperature at which a flammable liquid exposed to air will burn when exposed to sparks or flame. 16

FLASHPOINT Is the minimum temperature at which a liquid gives off a sufficient vapour to reach 100% LEL - sufficient vapour to form an ignitable mixture with air near the surface of the liquid. Liquids with flashpoints below normal ambient temperatures automatically release vapour in sufficient volume to provide an explosive mixture. Thus leakage of such liquids is potentially as dangerous as a flammable gas leak. 17

IGNITION ENERGY Ignition Energy Lowest amount of energy required for ignition Minimum Ignition Energy Lowest amount of energy required for ignition: Major variable Dependent on: Temperature % of combustible in combustant Type of compound 18

IGNITION ENERGY 19

Protection for Electrical Equipment Flameproof Enclosure Ex-d NON-SPARKING TYPE EQUIPMENT (Ex n ) Increased Safety Ex-e Intrinsically Safe Ex-ia/b Encapsulation Ex-m Pressurised Enclosure Ex-p SPECIAL TYPE EQUIPMENT (Ex s ) OIL IMMERSED TYPE EQUIPMENT (Ex o ) POWDER FILLED TYPE EQUIPMENT ( Ex q ) 20

SELECTION OF ELECTRICAL EQUIPMENT IN FOR SAFE USE IN HAZARDOUS AREAS Selection Criteria Gas Grouping (based on ignition energy) Temperature Classification Classified Zones Adequate precautions to avoid ESD & Lightning to be implemented. Use of light alloy (Mg, Al, Ti, ) material to be assessed critically in HA due to its incendive properties. Where reasonably practical, electrical apparatus generally and switch & control apparatus should be installed outside the Hazardous Areas. Electrical apparatus may be installed in open air in a non-hazardous area. Equipment designed for higher gas groups can be used for less hazardous gas groups ( for e.g., Equipment certified for II C can be used for II A, B or I) Portable hand-lamps, communication equipment and other test equipment shall be Ex i type All equipment shall be installed so as to avoid mechanical damage. Earthing shall be carried out as per SANS 10198-3, SANS 10199. Bonding of all pipeline flanges should be carried out so as to avoid Electro-static discharges. Internal earthing to be provided for all Flameproof equipment in addition to external earthing. 21

SELECTION OF ELECTRICAL EQUIPMENT IN FOR SAFE USE IN HAZARDOUS AREAS All circuits and apparatus in Hazardous Areas should be provided with means to ensure quick disconnection in the event of any fault (O/C, S/C or E/F) Protection & Control apparatus shall be normally located in non-ha but if unavoidable, they may be of the right protection type All electrical apparatus (for every apparatus or sub-groups) should be provided with an effective means of isolation, including neutral Metal conduits, armoured cables Correct terminations using proper sized cable glands (double-compression, FLP type) Unused cable openings of all electrical apparatus shall be closed with plugs suitable for the type of protection Copper or Aluminium (above 16 sq. mm only) conductors can be used Flameproof plugs & sockets should have preferably PUSH-IN, TWIST-ON type to avoid ignition while insertion or removal Adequacy of IP equipment 22

STATUTORY REGULATIONS AND STANDARDS SANS 10108:2008: The classification of hazardous locations and the selection of equipment for use in such locations ARP 0108: recommended practice Regulatory requirements for explosion-protected equipment. SANS 60079-10:2005: Electrical apparatus for explosive gas atmospheres. Part 10: Classification of hazardous areas. IEC 60079-10 -Electrical Apparatus for Explosive Gas Atmospheres, part 10 Classification of hazardous areas SANS 60079-14: 2003: Electrical apparatus for explosive gas atmospheres. Part 14: Electrical installations in hazardous areas other than mines. SANS 10086-1, The installation, inspection and maintenance of equipment used in explosive atmospheres Part 1: Installations including surface installations on mines. SANS 10089-2 The petroleum industry Part 2: Electrical installations in the distribution and marketing sector. SANS 61241-1-1 IEC 61241-1-1 - Electrical apparatus for use in the presence of combustible dust Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus. SANS 61241-1-2 IEC 61241-1-2 - Electrical apparatus for use in the presence of combustible dust Part 1-2: Electrical apparatus protected by enclosures and surface temperature limitation - Selection, installation and maintenance. SANS 61241-2-1 IEC 61241-2-1 - Electrical apparatus for use in the presence of combustible dust Part 2: Test methods Section 1: Methods for determining the minimum ignition temperatures of dust. SANS 61241-2-2 IEC 61241-2-2 - Electrical apparatus for use in the presence of combustible dust Part 2: Test methods Section 2: Method for determining the electrical resistivity of dust in layers. SANS 61241-2-3 IEC 61241-2-3- Electrical apparatus for use in the presence of combustible dust Part 2: Test methods Section 3: Method for determining minimum ignition energy of dust/air mixtures. SANS 61241-3 IEC 61241-3 -Electrical apparatus for use in the presence of combustible dust Part 3: Classification of areas where combustible dusts are or may be present. SANS 61241-4 IEC 61241-4 - Electrical apparatus for use in the presence of combustible dust Part 4: Type of protection "p 23

STATUTORY REGULATIONS AND STANDARDS IP Part 15 - Area Classification Code for Petroleum Installations API RP 500 : Recommended practice for classification of locations for electrical Installations at Petroleum Facilities Classified as Class1, Division 1 and Division 2. API RP 505 : Recommended practice for Classification of locations for Electrical installations at Petroleum Facilities classified as Class 1, Zone 0,Zone1 and Zone 2 NFPA 69, 1992, Explosion Prevention Systems 24

ACKNOWLEDGEMENTS I hereby wish to express my thanks to Fluor and SAFA for allowing me the opportunity to publish and present this paper and extend my appreciation to the delegates who sat so patiently and listened I also wish to thank and give credit to all those in the industry who have kindly allowed me the use of some of this information and for the many years assistance and dedication The information contained in this paper is based on many years experience and exposure of the author, in the field of hazardous area classification and selection of equipment for safe use therein, as well as the review and study of technical publications and other writers. While the statements purpose to be accurate, each reader is responsible for their own interpretation. 25

QUESTIONS? 26