Lonworks Damper Interface Catalogue

Similar documents
Smoke Fire Damper Interface (230V)

Fire Damper Interface (230V)

Smoke Damper Interface (230V)

Fire Damper Interface (24V)

Installation Datasheet

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

V3 Intelligent Damper Control and Monitoring System

October 2013 Bespoke Intelligent Damper Control and Monitoring System

Actionpac LNS3 Intelligent Damper Control and Monitoring System

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Actionpac 60/120 (LNS Standard)

Instructions for the fan motor control system, SILVER C

ACS-30-EU-EMDR- 10-MOD

Retroreflective sensor with polarization filter

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

EFBW series - BiWire Ultra control panel

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

Fire and Smoke Control Systems

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

REA 105 Arc Protection Module. Operator s Manual

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

RE-PR3-E-27 3-Phase Panel Mount 27kW

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

CommStat 4 Controller

Predator Controller Hardware Family

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Room Temperature Controller

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

Snifter ATEX22 VERSION. User Manual. Distributor

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Duct Temperature Sensors

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Installation, Operating and Maintenance Manual

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Wireless room thermostat with LCD

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

ISIS SAFETY SYSTEM Installation guide

Ionisation single-tube smoke detector for duct mounting

Operation and use. Functions and characteristics

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

LC2200 Level Controller Installation and Maintenance Instructions

KM300 Carbon Monoxide Detection System Installation Manual

Room thermostats with LCD RDD100..

Input module, input/output modules

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Multi-Gas-Controller MGC2

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Room thermostat with Auto Timer, Option External Input

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Tri-Stack Smart System

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

for relative humidity and temperature

CU-02 with Senaco Plus

Original operating instructions Safety switch with guard locking AC901S AC902S

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Door Release Power Supply

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

RTD-10 Installation Instructions

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Room thermostat with Auto Timer, Option External Input

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

DESCRIPTION NOTE. Temperature and Humidity Sensors MODEL 1260B

Room thermostat with Auto Timer, Option External Input

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

DCS-100. intelligent damper control & monitoring system

HYTEK ATEX APPROVED TANK ALARM

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Installation Guide. Bacharach HGM300 to LonWorks FT-10 Communications Adapter

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Magnetically Coded Non-contact Switch (MC2)

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Instruction Manual December 2001 ENACOCU02

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

Excellence in Level Measurement

SensaGuard TM Integrated Latch Installation Instructions

Smoke Vent Control Panel PCB4 V4 Installation Manual

Danfoss gas detection units

Use. For 2-pipe fan coils

Transcription:

Lonworks Damper Interface catalogue Release: 1.9 AUGUST 2017 Lonworks Damper Interface Catalogue Two Position, Three Position & Hot Smoke Fire Damper Interface This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly put at risk the lives of the occupants and the fabric of the building. - PAGE 1 - Always READ this document BEFORE ISTALLATIO. Please Retain for future reference.

SFDI-FT / FDI-FT / SDI-FT 230V / 120V / 24V Two Position Damper Interface The Safegard Damper Interface provides a complete LonWorks communication device to control dampers. Safegard developed the LonMark Functional Profile (11001) for smoke fire dampers and this has been adopted worldwide. ELECTROSTATIC SESITIVE DEVICE Two Position Smoke Fire Damper Interface Options: SFDI - FT The Safegard Smoke Fire Damper Interface provides a complete LonWorks communication device to control any failsafe spring-return smoke fire damper actuator that incorporates two auxiliary switches. FDI - FT The Safegard Fire Damper Interface provides a complete LonWorks communication device to failsafe, via an electromagnet, any spring-return fire damper. Monitoring of the open and/or closed position is optional. SDI - FT The Safegard Smoke Damper Interface provides a complete LonWorks communication device to control any open/closed smoke damper actuator that incorporates two auxiliary switches. Please note: Each interface is available in 24V, 120V, or 230V. Please specify a voltage at time of order. - PAGE 2 -

160 Mounting Diagram 120 10 Dimensions and Mounting The compact and robust design of the interface enclosure allows the unit to be mounted to a duct, block wall or stud wall. Ensure the Interface is located close enough to the actuator/damper it is controlling/monitoring. ormally, actuator/electromagnet leads are 1m in length. Also, ensure the Interface is accessible for future maintenance purposes. Please note: 200 75 220 150mm clearance required for lid removal and at cable entry points. Unused cable entries should be sealed with blind washers. 60 15 Do not drill the enclosure as this will affect its IP rating. aprox 25 aprox 25 Four mounting holes Ø 6mm for mounting with suitable screws depending on whether mounting to a duct, block wall or stud wall. Dimensions in mm. Preparation Only trained and qualified personnel should be allowed to install, replace or service this equipment. Installation should be in accordance with the relevant local safety standards. The connectors can accommodate cable diameters up to 2.5mm 2. It is recommended that all wires be crimped to ease installation and replacement of the product. The mains wiring should comply with IEC 60227 or IEC 60245. A switch or circuit breaker should be included as part of the installation. The switch or circuit breaker should meet the relevant requirements of IEC 60947-1 and IEC 60947-3. The switch or circuit breaker should be in close proximity to the equipment and be within easy reach of the operator. The switch or circuit breaker should be marked as the disconnecting device for the equipment and should disconnect both poles of the supply Installation 1. Disconnect the local supply before commencing any work on the Interface. 2. Wire the interface in accordance with the wiring diagrams shown following. If the actuator is to be located more than 5m from the Interface then contact Safegard Systems for technical assistance. 3. Please be aware that the switch and auxiliary inputs are not optically isolated. It is recommended that the optional detectors (smoke or heat) use failsafe open contacts to guarantee their detection in the event of a fault condition. It is also recommended that the network cables are not run alongside any high voltage or high frequency sources. Also, network cables must not be mixed on an individual network as they have very different electrical characteristics and could render the system unreliable. 4. If FDI-FT, the electromagnet failsafe realease is optional. If used, the electromagnet must be protected by a suitable snubber device. 5. If FDI-FT, the monitoring of the damper positions is optional. 6. Once wiring is complete, apply power to the DI-FT. The green power LED should illuminate to indicate the presence of power. 7. The Interface is now ready to be configured using a standard LonWorks tool such as LonMaker or the Safegard system. - PAGE 3 -

SFDI-FT Wiring: 230V & 120V SFDI-FT Wiring: 24V SAFEGARD SGS230-T Thermal Trip OPTIOAL SAFEGARD SGS24-T Thermal Trip OPTIOAL Actuator Example 230V Actuator Drive 2 1 S6 Actuator Position Sense S4 S2 S1 To Heat Detector To Smoke Detector HD SD Actuator Example 24V Actuator Drive 2 1 S6 Actuator Position Sense S4 S2 S1 To Heat Detector To Smoke Detector HD SD Aux Inputs Aux Inputs F1 ACTUATOR DRIVE SWITCH IPUTS AUX1 AUX2 L S6 S4 S2 S1 ACTUATOR DRIVE SWITCH IPUTS AUX1 AUX2 S6 S4 S2 S1 Green LED Green LED Red LED Power LED Red LED Power LED Yellow LED Blue LED Service LED Service Pin Yellow LED Blue LED Service LED Service Pin L POWER I POWER I 1AT OR 24V AC L 24V DC FDI-FT Wiring: 230V & 120V FDI-FT Wiring: 24V Electromagnet failsafe release OPE Fire Damper CLOSED Damper Position Sense To Heat Detector To Smoke Detector OPTIOAL HD SD Electromagnet failsafe release OPE Fire Damper CLOSED Damper Position Sense To Heat Detector To Smoke Detector OPTIOAL HD SD Aux Inputs Aux Inputs F1 ACTUATOR DRIVE SWITCH IPUTS AUX1 AUX2 L OPE CLOSED ACTUATOR DRIVE SWITCH IPUTS AUX1 AUX2 OPE CLOSED Green LED Green LED Red LED Power LED Red LED Power LED Yellow LED Blue LED Service LED Service Pin Yellow LED Blue LED Service LED Service Pin L POWER I POWER I 1AT OR 24V AC L - PAGE 4-24V DC

SDI-FT Wiring: 230V & 120V SDI-FT Wiring: 24V BELIMO BE230 OPTIOAL BELIMO BE24 OPTIOAL Actuator Example 230V Actuator Drive 2 1 3 S6 Actuator Position Sense S4 S2 S1 To Heat Detector To Smoke Detector Aux Inputs HD SD Actuator Example 24V Actuator Drive 2 1 3 S6 Actuator Position S4 Sense S2 S1 To Heat Detector To Smoke Detector Aux Inputs HD SD F1 ACTUATOR DRIVE SWITCH IPUTS AUX1 AUX2 L1 L2 S6 S4 S2 S1 ACTUATOR DRIVE +1 - +2 SWITCH IPUTS S6 S4 S2 S1 AUX1 AUX2 Green LED Green LED Red LED Power LED Red LED Power LED Yellow LED Blue LED Service LED Service Pin Yellow LED Blue LED Service LED Service Pin L POWER I POWER I 1AT OR 24V AC L 24V DC Maintenance 24V AC/DC version 5 x 20mm, Time-Lag Fuse, 2A rated (see F1 on wiring diagrams); for example Littlefuse 215 series 120/230VAC versions 5 x 20mm, Time-Lag Fuse, 1A rated (see F1 on wiring diagrams); for example Littlefuse 215 series LED Behaviour Function Green Red Yellow Blue Open On Off Closed Off On Travelling Flashing Flashing Fault flashing Ping one-shot Offline On On On On Wink function: Service LED flashes for 5s - PAGE 5 -

LonMark Objects ode object Mandatory network variables nv1 nvirequest SVT_obj_request nv2 nvostatus SVT_obj_status Optional network variables nv4 nvoalarm SVT_alarm FSDA object Mandatory network variables nv1 nviactudrive SVT_hvac_emerg nv2 nvoactuposn SVT_hvac_emerg Optional network variables nv3 nvoactudrivefb SVT_hvac_emerg Configuration properties Mandatory nc45 Drive Time nc48 Receive Heartbeat nc44 Safety Position nc30 Turn Off Time nc141 Zone umber Optional nc41 Actuator Label nc146 Installation Date nc17 Location Label nc147 Maintenance Date nc148 Manufacture Date nc61 OEM Label nc49 Send Heartbeat - PAGE 6 -

Two Position Smoke Fire Damper Interface Specifications LonWorks euron chip Transceiver type Service functions FT5000 ft-x2 service pin, service LED and neuron ID self-adhesive tag Environmental Operating temperature -5 C to 70 C Storage temperature -20 C to 70 C Humidity 25 % RH to 90 % RH at 70 C Maximum altitude 2000 m Supply (please specify at time of order) Input voltages Maximum power consumption 2.5 W Output Contact type Maximum switched load Inputs Contact type Sense current (230 ± 23) V AC, 50 Hz (120 ± 12) V AC, 60 Hz (24 ± 4.8) V AC, 50 Hz (24 ± 2.4) V DC DPCO mechanical relay contacts 25 VA non-isolated dry contacts 10 ma Conformance Agency Listings EMC ce E60730-1:00+A1:04+A2:08 +A16:07 CISPR 22 / FCC part 15, cl. B LVD E60730-1:2005 + + A2:2008 LonMark 11001 Enclosure Material IP rating IP 54 Flammability ul 94V-0 Pollution category 2 Dimensions (excl glands) Dimensions (incl glands) abs base with polycarbonate lid 200 mm x 120 mm x 75 mm (L x W x D) 200 mm x 170 mm x 75 mm (L x W x D) ote: Optional HDIE available: 300 C for 2 hour or 600 C for ½ hour applications. Please refer to Hot Enclosures Catalogue or contact Safegard Systems for details. - PAGE 7 -

3PSFDI-FT ~ 24V 25 VA Three Position Damper Interface The Safegard Systems 3PSFDI-FT provides a complete LonWorks device to control a single modulating actuator that incorporates two auxiliary switches. ELECTROSTATIC SESITIVE DEVICE Three Position Smoke Fire Damper Interface Options: Auto Mode Damper can be set to a balance position or drive open/closed and failsafe via spring-return or drives to the failsafe position. Local Mode Damper can be modulated via a 2-10V signal from the BMS and only instructed to failsafe by the system in the event of a fire alarm/fireman s override input. - PAGE 8 -

Dimensions and Mounting Mounting Diagram The compact and robust design of the interface enclosure allows the unit to be mounted to a duct, block wall, or stud wall. 200 75 aprox 25 Ensure the interface is located close enough to the actuator it is controlling/monitoring. ormally actuator leads are 1 m in length. Ensure the interface is accessible for future maintenance purposes. Please note: 150mm clearance required for lid removal and at cable entry points. Unused cable entries should be sealed with blind washers. Do not drill the enclosure as this will affect its IP rating. 160 60 15 aprox 25 120 Four mounting holes Ø 6mm for mounting with suitable screws depending on whether mounting to a duct, block wall or stud wall. Dimensions in mm. 220 10 - PAGE 9 -

Preparation Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Installation should be in accordance with the relevant local safety standards. The connectors can accommodate cable diameters up to 2.5 mm 2. It is recommended that all wires are crimped to ease installation and replacement of the product. Wiring Diagram 3PSFDI-FT in enclosure without lid Modulating actuator Thermal Trip LOCAL Mode U1 To BMS Y1 From BMS Installation 1. Disconnect the local supply before commencing any work on the interface. F1 ACTUATOR DRIVE ACT AUX SWITCHES LOCAL COTROL C2 C3 C4 24V Y U S6 S4 S2 S1 U1 Y1 2. Wire the interface in accordance with the wiring diagram shown across. If the actuator is located more than 5 m from the interface, then contact Safegard Systems for technical assistance. Status LEDs Green Red Yellow Blue Setpoint potentiometer Learn Switch Learn LED Power LED Service LED Service Pin 3. It is recommended that the network cables are not run alongside any high voltage or high frequency sources. cables should not be mixed on an individual network as they have very different electrical characteristics and could render the system unreliable. C1 POWER I C6 C5 4. Once the wiring is complete, apply power to the interface. 5. The interface is now ready to be configured using the Safegard Builder installation tool. C1 OR C1 24V AC 24V DC Replacement Fuse 2 A time-lag fuse (see F1 on wiring diagram). Suggested replacement: Littelfuse 215 series. Connector Description C1-1 24 V power C1-2 C2-4 Actuator 24 V C2-3 Actuator C2-2 Actuator Y signal C2-1 Actuator U signal C3-4 S6 C3-3 S4 C3-2 S2 C3-1 S1 Connector Description C4-4 U1 to BMS C4-3 to BMS C4-2 Y1 from BMS C4-1 from BMS C5-1 (do not connect) C5-2 C5-3 C6-1 (do not connect) C6-2 C6-3 - PAGE 10 -

Auto Mode Modulating actuator Thermal Trip Status LEDs Function Green Red Yellow Blue Open On Off Closed Off On Balanced On On Travelling Flashing Flashing Fault flashing Ping one-shot Offline On On On On Wink function: Service LED (yellow) flashes for 5s ACTUATOR DRIVE ACT AUX SWITCHES C2 C3 C4 F1 24V Y U S6 S4 S2 S1 U1 Y1 Status LEDs Green Red Yellow Blue Setpoint potentiometer C1 POWER I C6 C5 Smoke control system - PAGE 11 -

Learn Mode Modulating actuator Thermal Trip Status LEDs Function Green Red Yellow Learn On/Off On/Off ACTUATOR DRIVE ACT AUX SWITCHES C2 C3 C4 F1 24V Y U S6 S4 S2 S1 U1 Y1 Status LEDs Green Red Yellow Blue Setpoint potentiometer 1 Learn Switch on 2 Rotate the potentiometer to 0% to fully close the damper 3 Use the potentiometer to balance the damper in the required position - The Learn LED illuminates when the actuator is within 2º of the setpoint 4 Service Pin (hold for 1sec) C1 POWER I C6 C5 5 Learn Switch off Smoke control system - PAGE 12 -

Local Mode Modulating actuator Thermal Trip BUILDIG MAAGEMET SYSTEM Status LEDs Function Green Red Yellow Local on ACTUATOR DRIVE ACT AUX SWITCHES LOCAL COTROL C2 C3 C4 F1 24V Y U S6 S4 S2 S1 U1 Y1 Status LEDs Green Red Yellow Blue Setpoint potentiometer C1 POWER I C6 C5 Smoke control system - PAGE 13 -

Three Position Smoke Fire Damper Interface Specifications LonWorks euron chip FT 5000 Transceiver type Service functions Supply Input voltage Max power consumption Output Contact type Max switched load Inputs Contact type Sense current ft-x2 service Pin, Service LED, and neuron ID self-adhesive tag (24 ± 4.8) V AC, 50 Hz (24 ± 2.4) V DC 1.3 W spst mechanical relay contact 25 VA non-isolated dry contacts 10 ma Environmental Operating temperature -5 C to 70 C Storage temperature -20 C to 70 C Humidity 25 % RH to 90 % RH at 70 C Maximum altitude Conformance emc Agency listings Enclosure Material 2000 m en 60730-1:00+A1:04+A2:08+A16:07 CE IP rating IP 54 Flammability ul 94V-0 Pollution category 2 abs base with polycarbonate lid Dimensions (excl glands) 200 mm x 120 mm x 75 mm (L x W x D) Dimensions (incl glands) 200 mm x 170 mm x 75 mm (L x W x D) ote: Optional HDIE available: 300 C for 2 hour or 600 C for ½ hour applications. Please refer to Hot Enclosures Catalogue or contact Safegard Systems for details. - PAGE 14 -

Also available from Safegard Dampers Smoke/Fire dampers Fire dampers VCD s Shut-off dampers Access doors Industrial & heavy duty dampers (UL approved) Damper Control Products Safegard Systems have been the market leaders in this area of damper control & monitoring systems and offer a comprehensive range of control panel solutions for every project size and application. From our top specification V3 addressable system to our new low cost Smart system for up to 36 dampers, we have a control panel solution to meet all requirements. We also offer standard electro-mechanical panels where low damper quantity and simple control is required. Complies with European standards WARIG: The responsible body shall be made aware that, if the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. The information herein is subject to change without notice. We do not assume any liability arising out of the use of this product. Purchase of goods and services is subject to Safegard Systems standard terms and conditions. Product warranty 12 months from date of delivery. Actionair and Safegard are brand names of Swegon Air Management and Safegard Systems respectively and both companies are part of the Swegon Group. Swegon Air Management, South Street, Whitstable, Kent, CT5 3DU, UK T: 01227 276100 F: 01227 264262 E: sales@actionair.co.uk www.actionair.co.uk Unit 33, Southern Cross Business Park, Bray, Co. Wicklow, A98 HT99, Ireland T: +353 1 2761600 F: +353 1 2761611 E: info@safegard.ie www.safegard.ie