Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning

Similar documents
Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

Heat pump and energy recovery systems

Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper

Desiccant-enhanced evaporative (DEVap) cooler system introduction and its comparison with direct expansion (DX) system

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Scholars Research Library

Chapter 10. Passive Cooling Contents

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Review of Energy Efficient Cooling Techniques Based on Various Evaporative Cooling Systems

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

So far, we have covered the basic concepts of heat transfer and properties.

Solar Heating and Cooling Systems

Solar Liquid Desiccant Air- Conditioning

Novel Liquid Desiccant Systems

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

A SOLAR LIQUID-DESICCANT AIR CONDITIONER

ENGINEERING AND CONSTRUCTION BULLETIN

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

Impact of indirect evaporative air cooler type on the performance of desiccant systems

THE FIELD OPERATION OF A THERMALLY DRIVEN LIQUID-DESICCANT AIR CONDITIONER

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Liquid Desiccant Air Conditioning Systems

Adsorption Chillers Energysmart Green Cooling

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

Heat Recovery Units. Heat Recovery 1

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Review on Waste Heat Recovery Techniques in Air Conditioning Application

Hawaii Energy and Environmental Technologies (HEET) Initiative

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

A NEW STANDARD FOR COOL COMFORT

Pthey are comfortable. In regions with hot

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

MECHANICAL SCIENCE Module 2 Heat Exchangers

Asia Pacific Research Initiative for Sustainable Energy Systems 2013 (APRISES13)

Performance evaluation of a liquid desiccant solar air conditioning system

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

Recent Advances in Energy, Environment and Economic Development

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

EVALUATION OF HEAT REJECTION STRATEGIES FOR LIQUID DESICCANT AIR-CONDITIONING SYSTEMS

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Effects of Latent/Sensible Heat Separation Air-Conditioning and Natural Ventilation on Indoor Thermal Environment in Environment-Friendly Office

Field Test of Combined Desiccant-Evaporator Cycle Providing Lower Dew Points and Enhanced Dehumidification

Regenerator Design for Open Cycle Liquid Desiccant Systems Theoretical and Experimental Investigations

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

HVAC (Heating, Ventilating, and Air Conditioning)

Comfort and health-indoor air quality

Trane CDQ Desiccant Dehumidification

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

Energy Recovery Ventilation

2013 ASHRAE. Standards & Guidelines CD. Contents

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

SOLAR AIR CONDITONING SYSTEM USING DESSICANTS

White Paper. Executive Summary. Overview of Membrane Exchangers CLCH-PRB063A-EN. June 2017

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

AN ENVIRONMENT FRIENDLY COOLING OPTION

Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

Desiccant Cooling with Solar Energy

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System

CHAPTER 4. HVAC DELIVERY SYSTEMS

Air Conditioning and process cooling Energy Components at a Glance

Thermo Scientific Model 1160 Principle of Operation

White paper Compressed air drying

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

To Keep Docs Cool, Dry and Happy

Managing HVAC in High Performance Buildings

Oxyvap Evaporative Cooling Applications

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

Technical guides for owner/manager of an air conditioning system : volume 3. System recognition guideline for field visit

2. CURRICULUM. Sl. No.

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

Thermodynamics II Chapter 6 Mixtures & Psychrometry

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Appendix A. Glossary of Common Terms

Development of a Sorption Assisted Air Conditioning System Driven by a Solar Air Collector

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Chapter 11 REFRIGERATION CYCLES

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Do All DOAS Configurations Provide the Same Benefits?

Humidity Control Design Tips. R. Mark Nunnelly, PE, CxA, LEED AP President

RISKY REFRIGERANTS AND REDUCES ELECTRICAL CONSUMPTION BY

Thermodynamics II Chapter 5 Refrigeration

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM

Redesign of Bennett Hall HVAC System

Transcription:

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning Ranga Vamshi and Anurag Bajpai GreenTree Building Energy (P) Ltd., B 67, Sector 67, Noida, UP, India. Problem Statement: Air-conditioning system is the major energy juggler in energy juggler when compared with other energy consuming components in the building. It is contributes to approximately 40 60% of overall energy consumed in facility. In present market, there are systems available, which are of less energy intensive when compared with active vapor compression (and vapor absorption systems, like conventional evaporative coolers, EAT (Earth Air Tunnel) etc. Limitations with respect to evaporative coolers (direct and indirect type) are that, fundamentally these are limited by the moisture content in the air. Alone, these coolers can achieve temperatures that approach the dew point of the ambient air without adding humidity; however, they cannot dehumidify. Thereby, suitable for arid and semi-arid climates. Whereas, EAT is complex in execution, could not control the humidity and it requires additional active cooling systems to achieve the thermal comfort year round (Refer Figure 1). DEVap system, developed by NREL (National Renewable Energy Laboratory) is designed to address the inefficiencies mentioned above in present day less energy intensive airconditioning systems. This article informs about DEVap, its working principle and evaluation and limitations and advantages. Figure 1: Human Comfort Zone DEVap Introduction: DEVap is a concept of desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative cooling core. Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. Direct combining of desiccant driven dehumidification and indirect evaporative cooling technologies is customary, but it leads to too large and complex system. DEVap attempts to clear this hurdle and combine, in a single cooling core, evaporative and desiccant cooling. DEVap s crucial advantage is the intimate thermal contact between the dehumidification and the cooling heat sink, which makes dehumidification many times more potent. This design uses membrane technology to contain liquid desiccant and water.

When used to contain liquid desiccant, it eliminates desiccant entrainment into the airstream. When used to contain water, it eliminates wet surfaces, prevents bacterial growth and mineral buildup, and avoids cooling core degradation. DEVap s thermodynamic potential overcomes many shortcomings of standard refrigerationbased direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels. Thermal energy consumption correlates directly to the humidity level in the operating environment. heat exchange plates shown. The desiccant flows on the external side of the HMX plates. The plates are flocked, which effectively spreads the desiccant. This creates direct contact surfaces between the air and desiccant flows. The air passes between the plates, which are spaced 0.25 apart. DEVap System Working: DEVap concept is an enhancement of LDAC (Liquid Desiccant Air Conditioner). LDAC technology uses novel heat and mass exchangers (HMXs) to perform dehumidification with desiccant and desiccant reactivation using desiccant conditioner and scavenging air regenerator (Refer Figure 2). The liquid desiccant is absorbed into the conditioner (absorber) where the inlet ambient air is dehumidified. The liquid desiccant is regenerated in the regenerator (desorber) where the water vapor desorbs into the EA stream. This technology is called low flow liquid desiccant A/C, because the desiccant flow is minimized in both HMXs to the flow rate needed to absorb the necessary moisture from the air stream. The HMXs must therefore have integral heating and cooling sources (55 85 F cooling tower water is supplied to the conditioner). The regenerator uses hot water or hot steam at 160 212 F. The cooling or heating water flows internal to the 1 Figure 2: Major components and packaging of the AILR LDAC (Photograph shows packaged HMXs, water heater and cooling tower) 1: Packaged HMX; 2. Heater; 3. Cooling Tower Figure 3 provided below, illustrates the three basic ways to regenerate the desiccant system with a thermal source: solar, water heater, and a double effect. The water heater or boiler can be fueled by many sources, including natural gas, 2 3

combined heat and power (CHP), or even biofuels. 8. The two air streams are structurally separated by thin plastic sheets [a] through which thermal energy flows, including the heat of absorption [i]. 9. Water evaporates through the membranes and is transferred to the air stream [iii]. 10. The secondary air stream is exhausted [4] to the outside as hot humid air. Figure 3: LDAC Schematic The DEVap process follows (Refer Figure 4): 1. Ventilation air [1] and warm indoor air [2] are mixed into a single air stream. 2. This mixed air stream (now the product air) is drawn through the top channel in the heat exchange pair. 3. The product air stream is brought into intimate contact with the drying potential of the liquid desiccant [d] through a vapor-permeable membrane [e]. 4. Dehumidification [ii] occurs as the desiccant absorbs water vapor from the product air. 5. The product air stream is cooled and dehumidified, then supplied to the building space [3]. 6. A portion of the product air, which has had its dew point reduced (dehumidified), is drawn through the bottom channel of the heat exchange pair and acts as the secondary air stream. 7. The secondary air stream is brought into intimate contact with the water layer [c] through a vapor-permeable membrane [b]. Figure 4: DEVap concept description The water-side membrane implementation of DEVap is part of the original concept, but is not a necessary component. Its advantages are: Complete water containment. It completely solves problems with sumps and water droplets entrained into the air stream. Dry surfaces. The surface of the membrane becomes a dry to the touch surface that is made completely of plastic and resists biological growth. The water-side membrane may not be necessary in the DEVap configuration as wicked surfaces create successful evaporative coolers. Omitting this membrane would result in cost savings. The desiccant-side membrane is necessary to guarantee complete containment of the desiccant droplets and create a closed circuit to prevent desiccant leaks. It should have the following properties:

Complete desiccant containment. Breakthrough pressure (at which desiccant can be pushed through the micro-size pores) should be about 20 psi or greater. Water vapor permeability. The membrane should be thin (~25 μm) and have a pore size of about 0.1 μm. Its open area should exceed 70% to promote vapor transport. The DEVap cooling core (Refer Figure 5) is an idealized implementation of the air flows. A higher performing air flow configuration (Refer Figure 6) shows the cooling device split into two distinct areas and depicts the air flow channels from the top vantage point. The mixed ventilation air and return air enter from the bottom and exit at the top. The location of the desiccant drying section is shown in green; the location of the evaporative post cooling is shown in blue. Using OA to cool the dehumidification section improves the design by enabling higher air flow rates to provide more cooling. Thus, the left half of the exhaust channel (Refer Figure 5) is replaced by an OA stream that flows into the page (Exhaust Airflow #1). The deep cooling of the indirect evaporative cooler section requires a dry cooling sink; thus, some dry supply air is siphoned off (5% 30% under maximum cooling load) to provide this exhaust air stream (Exhaust Airflow #2). This section is placed in a counterflow arrangement to maximize the use of this air stream. This is essential because it has been dried with desiccant, and thus has a higher embodied energy than unconditioned air. The result is that the temperature of supply air is limited by its dew point and will come out between 55 75 F depending on how much is siphoned off. Combined with the desiccant s variable drying ability, the DEVap A/C system controls sensible and latent cooling independently and thus has a variable SHR between < 0 (latent cooling with some heating done) and 1.0. Figure 5: DEVap HMX air flows The DEVap core is only half of a complete air conditioner. Figure 6 depicts how the DEVap cooling core enhances the already developed LDAC technology and converts it from a dedicated outdoor air system to an air conditioner that performs space temperature and humidity control and provides all the necessary ventilation air. In fact, DEVap can be configured to provide 30% 100% ventilation air. Furthermore, DEVap does not require a cooling tower, which reduces its maintenance requirements.

Figure 8: Example schematic for commercial installation with Packaged DEVap Figure 6: DEVap enhancement for LDAC Because the drying process creates sufficiently dry air, the evaporative process is no longer a function of climate. Therefore, DEVap will work in all climates. Below illustrations provide possible configuration of DEVap in different type of facilities, Figure 7: Example schematic for residential installation Figure 9: Packaged DEVap Conclusion: DEVap is novel and disruptive, so bringing it into the entrenched conventional air conditioner market will create some market risk. Designing and installing a new DEVap system requires retraining. DEVap has unknown longevity and reliability compared to standard A/C. The availability of natural gas or other thermal energy sources may be an issue in certain places. However, DEVap does not require a large outdoor condenser, but instead uses a much smaller desiccant regenerator that can be placed inside or outside, and can be integrated with solar and waste heat. If these risks can be properly addressed, the DEVap air conditioner concept has strong potential to significantly reduce energy consumption and provide value to energy companies by reducing summertime

electric power demand and resulting grid strain. Also, unlike most heating, ventilation, and airconditioning systems, DEVap uses no environmentally harmful fluids, hydrofluorocarbons, or chlorofluorocarbons; instead, it uses water and concentrated salt water. References: ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) Standard 55-2004. Eric Kozubal, Jason Woods, Jay Burch, Aaron Boranian, and Tim Merrigan NREL/TP-5500-49722. ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) Standard 90.1-2007. Simulation Association (IBPSA India) and treasurer of Association of Energy Engineers. Ranga Vamshi is an engineer by profession with post-graduation in Energy (Convectional and Non-Conventional energy) and graduation in mechanical engineering. His areas of work involved HVAC, Energy Simulation Software, Energy Auditing, Green Buildings, Net Zero Energy Buildings. He is presently working at GreenTree, which is a sustainability development oriented consultancy firm, as an Energy Associate. He is a certified energy auditor and he was previously working with Hitachi and Jindal in domains of HVAC and Utilities (hydraulic drives and water cooling system) management respectively. Biography: Anurag Bajpai is Architect by curriculum with immense interest in sustainable development and its related technologies. nearly He has 10 years of experience working on projects related to Smart Energy Metering, Energy Storage Systems Monitoring, Net Zero Energy Buildings, Green Buildings, CFD Analysis. His assignments involved working for Siemens Power Engineering Limited (SPEL) and USAID ECO-III project to implement Energy Conservation Building Code (ECBC) and to enhance educational curriculum program. He is a Certified Measurement & Versification Professional (CMVP) by AEE, certified GRIHA (green building rating system) trainer and evaluator, LEED (I) AP, and an ECBC Expert Architect empanelled with Bureau of Energy Efficiency (BEE), Ministry of Power India. Besides, he also serves as a board member of International Building Performance and