Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique

Similar documents
CLI Refrigerant Gas Leak Detector. User s Guide

REFRIGERANT LEAK DETECTOR

GERMANY TEC 'LOGY leak-detect EXPERT

TEK-Mate. Refrigerant Leak Detector

TEK-Mate. Refrigerant Leak Detector

D-TEK Select. Refrigerant Leak Detector

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Leak-Seeker I Refrigerant Leak Detector

User Manual SF6 GASCHECK 6000

Refrigerant Leak Detector

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

SF 6 -Leak Pointer Operating Manual (original version) Type-No.: R002

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

OPERATING INSTRUCTIONS

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

TAP TAP-CLAMP

LD-5000 REFRIGERANT LEAK DETECTOR

NGD8800 USER S MANUAL

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

Gobi II. English. Condensate Pump Instruction manual Gobi II

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

RLD-H10P Refrigerant Leak Detector

H-10PM. Refrigerant Leak Detector

RLD-H10G Refrigerant Leak Detectors

testo 316-EX gas leak detector Instruction manual

DHUM-12 E DHUM-16 E DHUM-20 E DHUM-30 E

Best Practices for Mobile A/C Refrigerant System Service

Refrigerant / Combustibles Leak Detector

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

DOMETIC PTY. LTD. Camping Boxes-Refrigerator. Models: RC 1600 EGP Type: JCB - 1. Operating Instructions AUS

YELLOW JACKET. ACCUPROBE UV and ACCUPROBE II Refrigerant Leak Detector with Heated Sensor. Instruction and Operation Manual

2004 HVAC. Heating, Ventilation and Air Conditioning - Hummer H2. Fastener Tightening Specifications Specification Application

testo Leakage detector for gas Instruction manual

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

OIL COOLER INSTRUCTION HANDBOOK

Danfoss gas detection units

TRS21 IGNITION PROOF SERIES

5. MVAC-like appliance include appliances using R22 refrigerant a. True b. False

RESISTENT EXTRA 3592, 3602 RESISTENT EXTRA PLUS 3592P, 3602P

Leak Monitors and Leak Detectors

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

DC200 Digital Dispenser Operating Manual

GasAlert. Introduction. WWarning. Table 1. GasAlert Models. Gas Monitored

Portable Gas Leak Detector SP-220 Series TYPE F Operating Manual

TRS21 IGNITION PROOF SERIES

TECHNICAL SPECIFICATIONS *

compact office 24V compact office 24V Lux

Professional Wireless Rain Guage with 4" LCD

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Caresaver Universal Refrigerant Recovery Unit

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

OWNER S MANUAL (English)

USING R-134A REFRIGERANT

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

SENSIT HXG-2d Combustible Gas Detector

Gas leak detection + trapped person alarm

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Screw Water Cooled Chiller SCW210

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

EXC-450 User s Manual

MANUAL CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM

Combi Box 3 Way Fridge & Freezer

OWNER S MANUAL (English)

EVac II Programmable Digital Vacuum Gauge

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

HEATING AND AIR CONDITIONING

Dolphin PROX 2 Gyro Pool Cleaner

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

For technical support call:

5/12/2018 Climate Control System General Information and Diagnostics - Air Conditioning (A/C) System Recovery, Evacuation and Charging - G

GAS-Mate. Combustible Gas Leak Detector

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Remote alarm unit Art. Nr.:

Gallery Electric Fireplaces

USER MANUAL MINITRACER PORTABLE SNIFFER

A/C-Service Unit 7KG-MOBIL Art.-No

LEADERS IN LIQUID SCIENCE.

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

USER MANUAL TPS-M5/M55/M555

SERVICE INSTRUCTION. DYNAMIC COOLING with 0 zone REFRIGERATION. Fridge/freezer with. Publication number

LOKTRACE STRICTER LAWS! FIND THE LEAK! Avoid unnecessary fines. Trace gas leak detection

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Transcription:

REF-LOCATOR 4686714 TRACE-LOCATOR 4686715 Instruction Manual Electronic Leak Detector Bedienungsanleitung Elektronisches Lecksuchgerät Mode d emploi Détecteur de fuites électronique Istruzioni per l uso Rilevatore di perdite elettronico Manual de instrucciones Detector de fugas electrónico

Instruction Manual REF-LOCATOR / TRACE-LOCATOR English 1

English Instruction Manual REF-LOCATOR / TRACE-LOCATOR detector will sound a slow beep. The warm. The audio beep increases in frequency. 2

Instruction Manual REF-LOCATOR / TRACE-LOCATOR English Three Bars: Two Bars: One Bar: No Bars: No Bars/ Blinking: Full Voltage 1/2 Life 1/4 Life Low Voltage (Change Batteries) Unit will be disabled and not function properly in this state 3

English Instruction Manual REF-LOCATOR / TRACE-LOCATOR : LED s should last for years under normal use. If necessary, the LED s can be 4

Instruction Manual REF-LOCATOR / TRACE-LOCATOR English 5

English Instruction Manual REF-LOCATOR / TRACE-LOCATOR Replace filter whenever (figure 6

Instruction Manual REF-LOCATOR / TRACE-LOCATOR English Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Guide slot Raised spline Sensor Socket Sensor 7

English Instruction Manual REF-LOCATOR / TRACE-LOCATOR HFC s R410A, R404A, R407C, & R134a 6 white LED s. Auto shutoff after Instantaneous (static test) 0.100 sec moving at 3 /sec BTN LCD (black) with 10 segment color pie IP54. Housing incorporates O ring seal, openings 17 10 8

Instruction Manual REF-LOCATOR / TRACE-LOCATOR English 6 white LED s. Auto shutoff after 5 minutes BTN LCD (black) with 10 segment color pie IP54. Housing incorporates O ring seal, openings 17 10 9

English Instruction Manual REF-LOCATOR / TRACE-LOCATOR 10

REFCO Manufacturing Ltd. Industriestrasse 11 6285 Hitzkirch - Switzerland Telefon +41 41 919 72 82 Telefax +41 41 919 72 83 info@refco.ch www.refco.ch

English Congratulations on the purchase of the REFCO STARTEK Refrigeration Leak Detector, the most technologically advanced of its kind. The STARTEK s low power requirements, small size and high sensitivity combine to create a tool which is easy to handle and ultra effective at locating even the most difficult-to-find leaks. Fully SAE J1627 compliant, STARTEK will detect leaks as small as 0.1 oz/yr (3g/year) in R12, R22, R134a and other halogen refrigerant systems. STARTEK should not be used on systems that contain flammable refrigerants such as Propane, Isobutane, etc. TECHNICAL DATA Dimensions Weight Batteries Battery Life Sensitivity Sensor lifetime 150 x 34 x 55 mm 190 g 2 x AA batteries 40 hours Operating temperature 0 50 C Warm up time < 2 sec. Response time Reset time Probe length Warranty < 3g/year (0.1 oz/yr) approx. 30 hours instantaneous instantaneous 30 cm 2 years ES-02 (pack of 2) Part-No. 4507577 Replacement sensor 1

English English INSTRUCTIONS SAE J1628 RECOMMENDED PROCEDURES 1. Press the button to turn the unit on. 2. The LED will flash orange for a short moment to indicate auto-reset, afterwards the unit will begin beeping and flashing green. 3. To reset the unit to the existing level of ambient refrigerant, press and release the button. The LED will flash orange briefly to indicate the reset. All levels of refrigerant less than the reset level will be ignored. 4. Unit turns on in the low sensitivity level, which is adequate for most leaks. Press the button twice (double-click like a computer mouse). The LED will fade from red to green and a sweeping sound effect of low to high pitch will be heard. The sensitivity is now set for 3g/year (0.1oz/yr). This mode should only be used for looking for leaks of less than 14g/year (0.5 oz/yr). 5. Double click again to change back to low sensitivity. 6. Move the probe towards a suspected refrigerant leak at a rate of less than 2 inches (50 mm) per second, no more than ¼ inch (5 mm) away from the suspected source. 7. If a leak exists, the sound will increase in rate and pitch and the LED will start flashing rapidly. 8. To turn the STARTEK off, press and hold the button for 3 seconds. FEATURES If the sensor is damaged, a sweeping alarm and a red-green flash will indicate the problem. A flashing LED during normal operation also reflects the battery level: Green: batteries are fresh Orange: batteries should be changed If the batteries are nearly empty, the LED will turn solid red and a two-tone alarm will be noted for 5 seconds, before STARTEK will power itself off. If the unit is left on unattended, it will automatically turn off after about 5 minutes to conserve batteries. For the purpose of Automotive A/C Testing with respect to the SAE J1627 standard, the following leak testing procedure applies: 1. Operate the Startek in high sensitivity mode. 2. Leak test with the engine not in operation. 3. The air conditioning system shall be charged with sufficient refrigerant to have a gauge pressure of at least 340 kpa when not in operation. At temperatures below 15 C, leaks may not be measurable, since this pressure may not be reached. 4. Take care not to contaminate the detector probe tip. If the part is particularly dirty, it should be wiped off with a dry shop towel or blown off with shop air. No cleaners or solvents shall be used, since many electronic detectors are sensitive to their ingredients. 5. Visually trace the entire refrigerant system, and look for signs of air-conditioning lubricant leakage, damage, and corrosion on all lines, hoses, and components. Each questionable area shall be carefully checked with the detector probe, as well as all fittings, hose to line couplings, refrigerant controls, service ports with caps in place, brazed or welded areas, and areas around attachment points and hold-downs on lines and components. 6. Always follow the refrigerant system around in a continuous path so that no areas of potential leaks are missed. If a leak is found, always continue to test the remainder of the system. 7. At each area checked, the probe shall be moved around the location, at a rate no more than 25-50 mm/s and no more than 5 mm from the surface completely around the position. Slower and closer movement of the probe often helps locate the exact position of the leak. 8. An apparent leak shall be verified at least once by blowing shop air into the area of the suspected leak, if necessary, and repeating the check of the area. In cases of very large leaks, blowing out the area with shop air often helps locate the exact position of the leak. 9. Leak testing of the evaporator core while in the air conditioning module shall be accomplished by turning the air conditioning blower on high for a period of 15 sec. minimum, shutting it off, then waiting for the refrigerant to accumulate in the case for time specified by 2 3

Operation Manual Bedienungsanleitung Manuel d utilisation Manuale d istruzione Manual de Instrucciones STARTEK 10084 Rev. C REFCO Manufacturing Ltd. Industriestrasse 11 CH-6285 Hitzkirch (Switzerland) Telefon +41 41 919 72 82 Telefax +41 41 919 72 83 www.refco.ch info@refco.ch