Chromatographic Air circulated Refrigerator, two-door TC 603

Similar documents
Chromatographic Air circulated Refrigerator, two-door TC 603

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Laboratory Refrigerator/Deep Freezer TC 802

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

DOUBLE DOOR FREEZER.

Multi-Lab REFRIGERATORS Frigidere medicale

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

ULTRA.GUARD ultra low temperature freezer

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Constant climate chamber with ICH-compliant illumination

Constant climate chambers

Constant climate chambers

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Constant climate chambers

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

Constant climate chamber with humidity

Laboratory Refrigerators and Freezers

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

MEDICAL REFRIGERATORS

Platelet bags constant shaking for long periods of time.

Internet. Climate rating definitions. Customer service.

PR / MP I Laboratory / Medicine

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

REFRIGERATOR M E D I C A L.

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Heated and Refrigerated Incubators

Constant climate chambers

Laboratory Refrigerators and Freezers. Also with explosion-proof interior

Laboratory refrigerators and freezers

Refrigerated Incubators / Environmental Testing Chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

Plant growth chambers

Constant climate chambers

Environmental simulation chamber for complex alternating climate profiles

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Long Term Storage Cabinet

Biomedical Freezer 37 38

Air & Water Heat Pump R832

New Generation KBF 240 series

edition version 1.1 Green ICE KW Antibacteria

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

Laboratory Refrigerators and Freezers. Also with explosion-proof interior intrinsically safe, independently tested as well as certified.

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

Constant climate chambers

Laboratory refrigerators

www

Operating instructions Page 12

Constant climate chambers

Protect your research

Stability Chambers & Rooms

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Protection, safety, reliability. And more.

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Laboratory Refrigerators and Freezers

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

BIOMEDICAL REFRIGERATORS

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

REFRIGERATOR P H A R M A C Y.

Freeze Dry Systems and Accessories

VIBRA-series: VIBRA, VIBRA +

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

SD Storage Cabinet. Outstanding performance

Blood bank refrigerators

Refrigerators and freezers Research and laboratory 2018

Model KBWF 240 Growth chambers with light and humidity

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

ST Wiring diagram. Product description. Standard temperature controller. Order number

Advance Blood Storage system from Meditech

Model KBWF 720 Growth chambers with light and humidity

portable gas analyser

Model KBF 240 Constant climate chambers with large temperature / humidity range

Blood bank refrigerators and freezers. BBR & Mini - Platinum & Iridium - Plasmafrost Series

EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS

BFFF HUY. Partial Frost-free Bottom Combi Nyíregyháza Factory

Octalarm-T: the latest in future-proof industrial alarm diallers

Freeze Dry Systems and Accessories

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Medi Line MC, M1, M2, M3, VL

MICRO CLIMA-SERIES TM (COOLED) INCUBATORS AND WALLS

SD Storage Cabinet. Outstanding performance

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

SCAN200E USER S MANUAL

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Ice Lined Refrigerator User Operation & Maintenance manual

NEW GENERATION. Efficient use of valuable space INCUBATORS

DEKO Washer-disinfector WASHROOM SYSTEMS

Freeze Dry Systems and Accessories

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Transcription:

External Dimensions: B = 1500 mm T = 700 mm H = 2100 mm Internal Dimensions: B = 1345 mm (clear door with: 545 mm) T = 570 mm H = 1330 mm (lower edge of evaporator) Capacity: 1000 l Temperature Range: 2 C to 20 C Optional: -5 C to 20 C -5 C to -20 C Housing galvanized sheet steel with high quality white coating. With 4 feet, height adjustable. Optional: of stainless steel (Backplane, as well as top and bottom side of the cabinet of galvanised sheet steel) Set of 4 castors, 2 lockable Interior space Inner case of galvanized sheet steel with high quality white coating. Cleaning friendly by rounded corners, slippery surface in the interior, meets highest hygiene requirements Optional: of stainless steel Insulation high density foamed-in-place polyurethane, with a thickness of 75 mm. CFC-free Circulaton air cooling for rapid and uniform temperature control, reducing temperature gradients to a minimum. When the door is "open" the circulating fan is switched off automatically by a micro switch in order to prevent warmer ambient air being drawn in. Door Insulating triple-glazed double door. Grease resistant magnetic seal. Optional: door lock incl. 2 keys Interior fittings LED-Interior lighting, with automatic ON/OF micro switch 8 pcs. Grating-type shelves, withe coated (dim.: 530 x 550 mm) (max. 26 shelves possible) triple socket /damp room design, installed in refrigerator room, 230 V, 50 Hz, ON/OFF by illuminated switch on control panel 1 pcs. Cable port with cover 40 mm for example to create access for operator measurement lines etc. technische Änderungen vorbehalten Seite 1 von 7

Optional: Stainless steel shelves, or Stainless-steel drawer compartments (max. 26 drawers possible) with 3 lengthwise dividers, with telescopic-type guides on rollers with stops, Drawer dimensions: 500x475x77 mm (BxDxH), Usable width between the lengthwise dividers: 108,5 mm, lengthwise dividers easily removable Chromatographic-pillar-retainer Composed of: -> 4 pcs. Stand feet for bars of Ø 12-13 mm, with Laboral-alloy -> 12 pcs. Sleeve for stand bonding of Ø 12-13 mm, with Laboral-alloy -> 2 pcs. stand bars, length: approx. 100 cm, without thread, 18/8 Steel -> 2 pcs. stand bars, length: approx. 500 mm, without thread, 18/8 Steel -> 2 pcs. Universal clamp, Alu -> 1 pcs. key Telescope-leaf Of galvanized sheet steelt. (max.workload 50 kg) Optional: more workload Control system located above the door High quality electronic temperature regulator, TR 2002, with interface RS 485 Digital selected- and actual value display, permanently readable. Selected- and actual value: 1/10 à numerator can be selected (whole numbers) Selected value can be adjusted by foil coated button Ranges from 0 C to 30 C Working range from 2 C to 20 C Optional: -5 C to 20 C or -5 C to -20 C (provided that the ambient temperature is around 4 C above the set point). Temperature accuracy +/- 1,8 C after stabilising (with 50% filling) Acoustic and optical alarm indication when - selected value is exceeded or insufficient (variably adjustable) - Door open alarm (variably adjustable) - failure of temperature sensor - Defrost-time transgression (variable adjustable) Potential-free connection socket for extern alarm indication In the housing of the temperature regulator there are all relevant components for using the cabinet. Plug-in connectors of the electrical supply pipes enables an service friendly exchange. All failure signals are optical and acoustic displayed, the circuit of all single functions (cooling machine, etc.) are performed with triacs. Selected value and alarm can be bolted against manipulation. Optional: In case of a power outage, the unit is supplied with electricity from a independent accumulator (accu) with automatic activation (not attached to the electric mains current) and optical battery control. All control functions are saved for approx. 90 mins. Refrigerating unit fully hermetically sealed, forced ventilation, fitted on vibration - absorbing mounts (ambient temperature max. 32 C), low noise (52 dba/1m), energy saving compressor with high quality vaporisation system. Refrigerant: environment-friendly R 404 a Defrost technische Änderungen vorbehalten Seite 2 von 7

Automatic, with time and thermal monitoring by dew water evaporation. During the defrost period, the temperature inside the cabinet (only the airtemperature not the stored goods) will arise for a short time. Electrical Data Power supply 230 V/50 Hz /single phase Optional: 60 Hz Power input 130 W Energie consumption 3,5 KW (24 hours.) Fuse 10 A Power cable: 2,5 m with schuko plug Packing details (palletized) Dimensions: approx. 158x98x224 cm Net weight: approx. 230 kg Gross weight: approx. 260 kg Country of Origin: European Community Customs clearance code: 8418 5090 technische Änderungen vorbehalten Seite 3 von 7

Special Equipment and Accessories: Fault signalling equipment with cutting RS 485 (Alarmsystem) Installed permanently in control panel. Comes as standard with PSU for continuous operation. In event of mains failure the unit has a self-charging back-up battery with automatic cut-in (mains independent) and a visible battery power checking. Highly recommended for valuable drugs, vaccines etc. Abnormal deviations from set values are signalled with CONTINUOUS alpha- numerical by flashing on a display. Users are informed of such a deviation from the set value for a number of days. Date and duration of the deviation from the set value is recorded on the recorder (if fitted). Continuous fault signalling system UNT has an additional acoustic signal on the control panel which cuts in when the set value is undercut and stopping the cooling machine (to protect products against low temperatures). Acoustic signal can be cleared by pressing a button. Optical alarm can be cleared only by pressing a safety button. Port for external fault alarms is zero potential. Continuous fault signalling system UEB has an additional acoustic signal on the control panel which cuts in when the set value is exceeded (to protect products against excess temperatures). Acoustic alarm can be cleared by pressing a button. Optical alarm can be cleared only by pressing a safety button. Port for external fault alarms is zero potential. Optional: Door open Alarm, Software for Fault signalling equipment incl. Dongle and interface converter RS 485 to RS 232 for Windows 2000/NT (max. for 8 cabinets) Round Chart recorder to record temperature, permanently installed in control panel. Comes as standard with battery back-up power supply for continuous operation (mains independent).the replaceable recording discs are suitable for 24 hours or 7 day periods. The actual temperature is plotted with a black felt tip pen on the chart. Internal temperature measurement. Measurement range: -10 C to 40 C The unit comes with 100 round charts (day or week) Door lock, incl. 2 keys Dew water collector tank for manual emptying (i.e. for using this cabinet in operating rooms and clean rooms) technische Änderungen vorbehalten Seite 4 von 7

Wireless data logger, complete consisting of: Wireless data logger, SPY RF U1 1-channel for Pt100, 4-20mA / 0-1V / contact on-off, with display measurement accuracy at 23 C: +/- 0,3 C Resolution 0,1 C Battery : Lithium Battery Recording interval: 1 sec. to 90 minutes Internal memory: 10.000 measurements Usable range: 1km LOS Communication: via radio 868 Mhz Power: 25 mw incl. 1 pcs. Sensor of stainless steel, Ø 4,0mm L=30mm Pt100 class A with plugged cable of PTFE Measurement area: -200 C +200 C Length: 3 meter Optional: 8 meter Delivery contents: wall mounting holder and plug protection Software - Basic Version for single user - Maintenance of multiple Wireless data logger - collect the recorded data of the Wireless data logger - Back up data (tamper-proof) - Prepare the data in terms of graphics or charts - Excel exportable - Maintenace of alarms via potential free contact at the Modem - or Alarmsystem (SMS, phone call, blinking light, buzzer) SPY RF USB-Modem for data transfer to the PC via USB-connector - communication with infinete numbers of Wireless data logger - remote alarm via integrated potential contact - including wall mounting holder technische Änderungen vorbehalten Seite 5 von 7

Optional: Sensor of stainless steel Ø 4,0mm L=30mm Pt100 class A, with plugged cable of PTFE, Measurement area: -200 C +200 C Length: 8 Meter SPY RF Relay (Repeater) - Allows the data transfer of the data logger about bigger distances - Can transfer dates of one or several SPY RF data logger - Electricity supply about power supply unit and battery in case of power failure - with 2 output ranges: 25mW to communicate with the data logger and 500mW to communicate with the modem. - Delivered with wall mounting fixture - Ambient temperature: from -10 C to +70 C SPY RF Alarm - realtime alerting - i.e. by limit exceeded or power failure - Local warning - Integrated acoustical and optical Alarm - Power supply via external power adapter and spare battery in case of power failure - Button for local alarm quitt - Relais output for remote alarm) (GSM-Modem, telephone dialer) - including wall mounting holder SPY RF Telephone dialer - In the speech modus it called up to 6 different subscriber and informed them about the kind of failure - This ergonomically linguistic aid provides high operational ease. - requires an analogue phone line - Individual adjustment of identification, alarms and alarm quitt - requires an external power supply (included) GSM-Modem I for switch contact For use with: Software - Basic Version and SPY RF USB-Modem, or SPY RF Alarm - Enables to send SMS messages - Modem registered also power failure and send SMS immediately. technische Änderungen vorbehalten Seite 6 von 7

Qualifications IQ (Installation Qualification) The IQ documentation is worked out by us especially for the delivered machine and is made available to you. The IQ documentation is to be carried out by the customer itself. If the IQ qualification should be carried out by us on site, we calculate to you our current daily rate plus driving expenses if necessary overnight stay and business expenses OQ (Operational Qualification) The OQ documentation is worked out by us especially for the delivered machine and is made available to you. The OQ documentation is to be carried out by the customer itself. If the OQ qualification should be carried out by us on site, we calculate to you our current daily rate plus driving expenses if necessary overnight stay and business expenses CQ (Calibration Qualification) Checking the temperature in the refrigerator 1 Temperature on 3 different measuring points evenly located on the shelves. Inspection time 6 hours, open door after that of 30 seconds. The inside temperature of the cabinet must have stabilized itself within 1 hour on the set point temperature. The temperature measures are carried out in our company, represented graphically and provided to you. The values may not dropping below or above the tolerances given by us. (additional measuring points on request) technische Änderungen vorbehalten Seite 7 von 7