Hornet HP Elbow 3. Round Adj Pull-Down Features Tiny. Powerful. Unobtrusive. The Hornet HP family delivers strong, focused, dimmable beams of light with consistent color and punch. This year s Hornet HP technology enhancements feature advanced crisp whites, expanded color ranges, top efficiency, and impressive new dimming options. These highlights characterize the brand new Downlight small in size, but BIG on power. Hornet HP Downlights. ighting with a twist. Product Overview Type: Round Adjustable Pull-Down Accent & Display attage: 13, 18, 20 umen Output: 1,369 max; 76 m/ (spot optic) CBCP: 12,21 max (spot optic) Color Temp: 2200K, 2700K, 3000K, 300K, 4000K, CRISP CRI: 83 typ. (2700K, 3000K, 300K, 4000K) 90+ typ. (2200K, 2700K, 3000K) Crisp (18 max) & 3K Class A available : TRIAC & EV (120V/277V) - % Dim utron A Series (120V/277V), 3-wire/EcoSystem Hi-lume - 1% dim utron H Series (120V/277V), EcoSystem, Hi-lume - 1% dim with soft on, fade to black 0-10V dimming, 1% Dim DAI (120V/277V) - 1% Dim Fixture Summary (see following pages for more information) Performance Chart Delivered atts umens P CBCP Color Temp 13 972 7 8,673 3000K-83 18 1,20 67 10,749 3000K-83 20 1,369 68 12,21 3000K-83 Data is based on 3000K-83, 120V IES files available on website Data is based on Spot optic See pages -6 for other beam spreads Electrical Data 13 18 20 System atts Amps System atts Amps System atts Amps 120V 13 0.11 18 0.1 20 0.17 277V 13 0.0 18 0.06 20 0.07 Electronic constant current ED driver All wattages include 2 thermal protector IT-2113 04/09/18 Page 1 of 9
Housing/Frame Ordering Information 1 T 2 3 4 6 1 2 3 Model For New Construction HD-HP-R-NC-A17 (New Construction) HD-HP-R-CP-A17 (Chicago Plenum (CCEA) housing) HD-HP-R-IC-A17 (Insulated Ceiling/air tight, 13 & 18 only) For Existing Ceilings HD-HP-R-REM-A17 (Remodeler) Style T - trimmed attage 13 18 20 (not available for use with IC housing) 4 6 Voltage 120 277 120/277 (for use with IC housing only) (for non-dimming, select E/TE option) E/TE - TRIAC/EV dimming HIUME-A - utron Hi-lume A Series, 3-wire/EcoSystem, Hi-lume, 1% dim HIUME-H - utron Hi-lume H Series, EcoSystem Hi-lume, 1% dim with soft on, fade to black 0-10V - 0-10V dimming; 1% dim DAI - DAI dimming, 1% dim Options/Accessories EM - emergency battery pack with remote test switch (not available for use with REM, CP or IC options) Trim Ordering Information HD-HP-EB-A17 1 T 2 3 4 1 2 3 Model HD-HP-EB-A17 Style T - trimmed Finish M - matte white MB - matte black SV - silver Color Temp 83 CRI 90+ CRI 27-2700K-83 229-2200K-90+ CRISP - Crisp 30-3000K-83 279-2700K-90+ (18 max) 3-300K-83 309-3000K-90+ 3CA - 3K Class A 40-4000K-83 39-300K-90+ 409-4000K-90+ 4 Beam Spreads SP - spot, 1º NF - narrow flood, 20º MF - medium flood, 24º F - flood, 28º F - wide flood, 4º VF - very wide flood, 60º S - linear spread, 60º x 10º The "A" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your Amerlux representative for explanations of changes. IT-2113 04/09/18 Page 2 of 9
Specifications Application Retail and commercial accent and display lighting Construction 20 ga. galvanized steel frame 18 ga. galvanized steel splice housing and hanger brackets (not for Remodeler version) Die-cast optical housing and trim Die-cast heatsink Optical Pull-down adjustable, 60º max tilt, 36º rotation Beam spreads: Spot, 1º; Narrow Flood, 20º; Medium Flood, 24º; Flood, 28º; ide Flood, 4º Very ide Flood, 60º; ar Spread, 60º x 10º ED Color Temp Options: 2200K, 2700K, 3000K, 300K, 4000K CRI: 83 typ. (2700K, 3000K, 300K, 4000K) 90+ typ. (2200K, 2700K, 3000K, 300K, 4000K) Crisp* ED available, 18 max Class A** 3000K (high CRI, high gamut) R9 Values: 11 (83 CRI), (92 CRI) Binning: 3 MacAdam (SDCM) ife: 0,000+ hrs, > 70% of initial lumens at 0,000 hrs *Crisp: Crisp Technology delivers the warmth of colors expected from a high 90 CRI solution but also creates the natural crisp white color that is pleasing to the eye. It creates the most impactful lighting ever available, by revealing the richest whites and vibrant colors that pop. **Class A ED: Class A ED s have a CRI > 80 and a GAI > 80. CRI defines color Naturalness and GAI defines color Saturation. Both being high delivers rich colors and pure whites. Electrical attage: 13, 18, 20 Electronic constant current ED driver, 120V/277V input This product complies with IEEE C62.41 for surge endurance up to 2.KV. Amerlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. E/TE - eading Edge, TRIAC, forward phase/trailing Edge, EV, reverse phase 0-10V, utron and DAI systems also available See pages 8-9 for more dimming information Finish Powder coat paint Consult factory for custom finishes Mounting For use in grid or sheetrock ceilings, 1 thick max 26 Hanger bars included (except for Remodeler versions) Consult factory for hanger bars greater than 26 Certifications CSA damp as tested to U 198 standards IC/AT rated (optional) arranty year limited warranty Emergency Battery Pack (EM) Powers fixture at.1 watts (approx. 400 m) for 90 minutes (not for use with REM, CP or IC/AT versions) IT-2113 04/09/18 Page 3 of 9
4 7 1 /2 Frame with Emergency Battery Pack Optional CP or IC/AT housing 13 /16 11 1 /2 13 1 /4 11 /8 7 /8 7 3 /4 12 1 /8 12 13 3 /16 11 /8 7 3 /4 7 13 /16 11 1 /2 14 1 /2 min - 26 max 1 /2 Ceiling cut out: 4 dia. 3 1 /16 4 1 /16 /8 (1 max) Ø2 1 /4 Ø4 3 /8 /16 Ø4 3 /8 3 1 /8 3 1 /8 6 13 /16 3 1 /16 Emergency Battery Pack 3 1 /8 13 3 /8 13 1 /4 7 3 /16 13 9 /16 60 max IT-2113 04/09/18 Page 4 of 9
Remodeler 3 /16 8 1 /16 4 2 1 /4 STRUCTURE 1 /2 Min. Clearance 7 9 /16 13 /16 Ceiling cut out: 4 dia. 3 1 /16 Ø2 1 /4 /8 /16 Ø4 3 /8 3 1 /8 6 13 /16 3 1 /16 60 max IT-2113 04/09/18 Page of 9
FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MUTIPYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES file on website) attage: 13 18 20 Factor: 0.6 0.90 1.0 CCT: 2700K-83 3000K-83 300K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 300K-90+ 4000K-90+ CRISP 3CA Factor: 0.71 0.80 0.83 0.87 0.90 0.6 0.7 20 ED, 3000K (For F & F data see page 6) Spot (SP) Distribution, 1º T #8377 umens: 1,369 180 90 Narrow Flood (NF) Distribution, 22º T#86027 umens: 1,307 180 90 200 7 170 7 000 60 300 60 700 20 4 10000 4 7000 1200 0 1 30 Candelas at Nadir Deg Candela 0 1221 8436 1 170 2 204 3 77 4 26 0 1 30 Candelas at Nadir Deg Candela 0 722 6128 1 1841 2 309 3 93 4 41 Application Data: D Notes and Definitions: Beam spread is to 0% center beam candlepower (CBCP). D=Distance to floor or wall. =Footcandles on floor or wall at center beam aiming location. =Effective Visual Beam length in feet (0% of maximum footcandle level). =Effective Visual Beam width in feet (0% of maximum footcandle level). CB=Distance across or down to center beam location. D 30º CB 30 CB 0 o Aiming Angle Horizontal Footcandles 30 o Aiming Angle 30 o Aiming Angle 30º Horizontal 30º Vertical Footcandles 60º Footcandles 60 o Aiming Angle Vertical Footcandles Spot D.0 484 1.4 1.4 7. 216 2.0 2.0 10.0 122 2.7 2.7 12. 78 3.4 3.4.0 313 1.8 1. 3.0 7. 136 2.8 2.4 4.0 10.0 76 3.7 3.2 6.0 12. 46 4.8 4.2 7.0 3.0 178 3.0 1.6.0 4.0 10 3.8 2.1 6.0.0 67 4.8 2.7 8.0 6.0 47.9 3.2 9.0 3.0 630 1.6 1.1 2.0 4.0 40 1.6 1.3 2.0.0 298 2.0 1.6 3.0 6.0 200 2.4 1.9 3.0 Narrow Flood D.0 289 1.7 1.7 7. 129 2.8 2.8 10.0 73 3.6 3.6 12. 47 4. 4..0 187 2.4 2.1 3.0 7. 86 3. 3.1 4.0 10.0 47 4.7 4.1.0 12. 31.8.2 7.0 3.0 127 3.3 1.8 4.0 4.0 70 4.4 2.7 6.0.0 47.3 3.2 7.0 6.0 32 6.7 3.9 8.0 3.0 422 1.9 1.3 2.0 4.0 298 1.9 1. 2.0.0 181 2. 2.1 3.0 6.0 133 2.8 2. 3.0 IT-2113 04/09/18 Page 6 of 9
FIXTURE DATA: (Complete photometric data (.ies format) available upon request) Flood (F) Distribution, 28º T # 86028 umens: 1,28 ide Flood (F) Distribution, 4º T # 86029 umens: 1,278 MUTIPYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES file on website) attage: 13 18 20 Factor: 0.6 0.90 1.0 CCT: 2700K-83 3000K-83 300K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 300K-90+ 4000K-90+ CRISP 3CA Factor: 0.71 0.80 0.83 0.87 0.90 0.6 0.7 20 ED, 3000K (For SP & NF data see page ) 180 90 180 90 7 00 7 1000 60 1000 60 2000 100 4 4 3000 2000 200 0 1 30 Candelas at Nadir Deg Candela 0 31 3304 1 1861 2 612 3 16 4 7 0 1 30 Candelas at Nadir Deg Candela 0 2369 2268 1 192 2 74 3 21 4 82 Application Data: D Notes and Definitions: Beam spread is to 0% center beam candlepower (CBCP). D=Distance to floor or wall. =Footcandles on floor or wall at center beam aiming location. =Effective Visual Beam length in feet (0% of maximum footcandle level). =Effective Visual Beam width in feet (0% of maximum footcandle level). CB=Distance across or down to center beam location. D 30º CB 30 CB 0 o Aiming Angle Horizontal Footcandles 30 o Aiming Angle 30 o Aiming Angle 30º Horizontal 30º Vertical Footcandles 60º Footcandles 60 o Aiming Angle Vertical Footcandles Flood ide Flood D.0 142 2.7 2.7 7. 63 3.9 3.9 10.0 36.2.2 12. 23 6. 6. D.0 9 3.2 3.2 7. 42 4.8 4.8 10.0 24 6.4 6.4 12. 1 8.0 8.0.0 92 3.4 3.1 3.0 7. 43 4.9 4.4 4.0 10.0 2 6.4.8.0 12. 16 8.0 7.2 6.0.0 67 3.9 3.4 2.0 7. 30.7.3 3.0 10.0 17 7.6 7.1 4.0 12. 11 9.6 8.9.0 3.0 7 3.8 2.7 4.0 4.0 44 4.9 3.3.0.0 29 6.1 4.1 6.0 6.0 20 7.4.1 7.0 3.0 63 3.7 2.8 3.0 4.0 36 4.9 3.7 4.0.0 23 6.1 4.8.0 6.0 16 7..7 6.0 3.0 232 2.3 1.7 2.0 4.0 14 2.7 2.4 2.0.0 9 3.4 3.0 2.0 6.0 69 3.8 3. 3.0 3.0 180 2.4 2.0 1.0 4.0 10 3.2 2.9 2.0.0 69 3.8 3. 2.0 6.0 47 4.7 4.3 3.0 IT-2113 04/09/18 Page 7 of 9
DIMMING COMPATIBIITY: Amerlux Hornet fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMATION BEO IS FOR IRED DIMMERS ONY. FOR IREESS DIMMERS, CONSUT FACTORY --- TRIAC (Forward Phase) DIMMING (Standard) Utilizes Standard incandescent dimmers that are in wide use in installations across the US. Best for retrofit applications where TRIAC dimmers are installed. 120V or 277V* Dims down to less than % light output (most cases) Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! Must meet dimmer Minimum oad Requirements per dimming manufacturer all Box (Incandescent Style, attage as required) utron Diva utron Vareo utron Nova-T utron Skylark utron Maestro TRIAC iring Diagram TRIAC Green utron GP Panel utron Grafik Eye QS EV - Electronic ow Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized EV dimmers. Best for New Construction applications EV iring Diagram 120V or 277V* Dims down to less than % light output (most cases) EV Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! Must meet dimmer Minimum oad Requirements all Box (EV Style) utron Diva utron Nova-T utron Maestro eviton Surslide utron Vareo utron Skylark eviton Vizio Green utron GP Panel with PHPM-PA Interface utron Grafik Eye QS with PHPM-PA Interface 0-10V - DIMMING (-0-10V Option) Integrates into a variety of building management and daylighting controls 0-10V iring Diagram 120V or 277V* Dims down to 1% light output Requires interface to turn off power to driver Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! 0-10V Gray Purple Green 0-10V (-) 0-10V (+) Switched Hot all Box utron Diva - DVTV with PP- 120H Interface eviton Renoir II 0-10v utron Grafik Eye with GRX-TVI Interface * is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimming installation instructions for 277V wiring diagrams. IT-2113 04/09/18 Page 8 of 9
DIMMING COMPATIBIITY: Amerlux Hornet fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMATION BEO IS FOR IRED DIMMERS ONY. FOR IREESS DIMMERS, CONSUT FACTORY --- UTRON A-SERIES HI-UME / ECOSYSTEM (-HIUME-A option) Integrates into utron EcoSystem building management 3-ire iring Diagram 120V or 277V* Dims down to less than % light output May use 3-ire or EcoSystem Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! Cap unused ECOSYS wires 3-ire Phase Purple Stripe Purple Orange Green E1 E2 Dimmed Hot Switched Hot all Box (3-ire Fluorescent) DIVA Maestro Nova T Vareo utron EcoSystem compatible controls EcoSystem Digital iring Diagram E2 E1 ECOSYS Bus EcoSystem Purple Stripe E1 Purple E2 (Cap off Orange wire) Orange Dimmed Hot Switched Hot Green DAI DIMMING (-DAI OPTION) Digital control protocol allows individual fixture control DAI iring Diagram 120V - 277V* Dims down to 1% light output in most cases all Box (3-ire Fluorescent) eviton CD20 ler Dynalite Fifth ight DAI DAI Bus Purple Purple/T Green EMERGENCY DIMMING (-EM OPTION) iring Diagram Unswitched Hot Common ED oad AC ED ED ED Output Output Blue all Switch Thermal Protector T/ T/BK Blue Yellow/BK Yellow E F M E F le ER D le x D G x RI A EN B V C ER Y Violet Brown Violet Brown 2-ITS Converter Connector Test Switch * is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimming installation instructions for 277V wiring diagrams. IT-2113 04/09/18 Page 9 of 9