SecuriSens LIST Product Catalogue 2015

Similar documents
SecuriSens d-list Product Catalogue 2015

SecuriBeam Optical Beam Fire Detectors

On the job around the clock 24/7: Fire detection systems

d-list Line Type Heat Detector Manual SCU SEC 15 Valid as of: Software version V1.24 LISTEC and LIST are registered trade marks

Fire control panels FC726 FC726-XA

Fire Detection Systems Product Catalogue (Version )

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Interface and EOL Modules 8

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

System 800 Addressable Fire Detection & Alarm System

Installation, Operating and Maintenance Manual

Fire control panel detect 3004 plus and accessories

Remote alarm indicator and test combination MK2430

ASD 535 Aspirating smoke detector

ADW 535 Line type heat detector

SCR100 User Manual. Version:1.1 Date:Dec 2009

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

FC700A Fire detection control unit

Engineering Guideline. pac- Carriers Type Universal

SecuriFire SecuriLine extended board B5-DXI2

FC724 Fire control panel

FC722 Fire control panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Danfoss gas detection units

FC724 Fire control panel

ORION Mini-Rep INSTALLATION MANUAL

FC723 Fire control panel

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Fire control panels FC360

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Solution F2. Fire Alarm Control Panels one step ahead.

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Multi-Gas-Controller MGC2

Danfoss gas detection unit Type GD Heavy Duty

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

SUPREMATouch. Modular Fire & Gas Detection System

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

FC722 Fire control panel

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

FlexiSmoke WSC 520 / WSC 540 / WSC 560 Modular smoke ventilation panel 20-60A

INSTALLATION INSTRUCTIONS

PRELIMINARY EDITION

5000 INSTALLATION GUIDE

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Version 3 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 STANDARD Smoke control panel 10-20A

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

SecuriRAS ASD 535 Product Catalogue 2015

Standard detectors. General information. Product Sheet Detec on

SUPREMATouch. Modular Fire & Gas Detection System

Data Sheet. Self regulating heating tapes. RS stock numbers

BX-MDI8 Input module for SecuriLine extended

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

SecuriFire. SecuriLine Unit B6-LXI2. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland

RAYCHEM NGC-30 COMPONENTS

FEC400 Series. Installation Manual

LASER ASPIRATED SMOKE DETECTOR

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

IQ8Control C Fire Alarm Panel

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

For Complete Fire and Gas Solutions

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

FlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE

FC2020 Fire control panel

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Leakage Detection. WaterAlarmSystems Fuel-oil/WaterAlarms. Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

SecuriRAS ASD 531/532/535

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

OOH740, OOHC740 Automatic fire detectors

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

1. MAIN CONTROL UNIT MCU Accessories for MCU OPERATING AND DISPLAY PANELS... 10

Data Sheet. Self regulating process heating tapes RS stock numbers ,

SecuriRAS ASD 535 Product Catalogue 2014

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Instruction Manual Model Backup Switch, 1 for 8

MHD 535. General functions and specific requirements

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Sonos-SB Siren/Beacon

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

561-MB256 plus. Intruder alarm control panel. Performance features

Economically Productive Universal applicable

FDCL221 Line separator

Heimdall Radar Traffic Detector

Analogue Addressable Fire Panels FP1500. Manual for Installation, Configuration and Commissioning

Heimdall Radar Traffic Detector

Chlorine gas leak detector

RS485 MODBUS Module 8AI

Insulation fault evaluator EDS460-DG

Transcription:

SecuriSens LIST Product Catalogue 2015

Content 1. Processor Units... 5 2. Cable... 7 3. Accessories List... 8 4. Spare Parts... 13 5. Services... 15 6. Product Type Index... 16 2 Securiton Product Catalogue 2015 LIST

Introduction SecuriSens LIST heat detectors, where all other detectors reach their limits. Dust, heat, smoke, exhaust fumes and other interference factors have a significant impact on detecting fires when using conventional fire detectors. However, it is exactly under such difficult conditions that the fire risk is so great and it is vital to ensure quick and reliable detection such as in tunnels, industrial facilities, power plants and car parks. With the SecuriSens LIST line-type heat detectors, Securiton provides systems that can enable the rapid localisation of a fire even when used in harsh, aggressive environments. Safety in tunnels the SecuriSens LIST. The SecuriSens LIST SEC 20 line-type heat detector is the ideal fire detector for use in tunnels. It consists of the SEC 20 sensor cable and the LISTcontroller. The system offers reliable monitoring of sections of up to 3,200 metres in length, or up to 350 sensors. Up to two sensor cables can be connected to one LISTcontroller (stub, loop or in redundant operation with a second LISTcontroller). The detection and alarm thresholds can be configured for a maximum of 254 different alarm sections. Every ten seconds, the system measures the temperature on the sensors and compares this with the programmed threshold values. Outstanding flexibility because every object needs individual protection. The spacing between sensors can be freely selected, and it is even possible to combine different sensor spacing distances. You can see where the sensors are located according to the markings on the outer sheathing of the sensor cable. Another highlight (and one that is absolutely unique on the market) is the problem-free branching of the cable harnesses. External individual sensors in metal housings are available for special applications and can be easily connected to the SecuriSens LIST system. Different sensor cable areas can be connected together with one signal cable. Product The descriptions and technical data included in this catalogue are up-to-date at the time of release. We reserve the right to make alterations to them, particularly where justified by technological advancements. The illustrated products may also differ visually from the products supplied as a result of continuous further development of products. The layout of this catalogue is subject to copyright. The copying or reuse of text, illustrations and photos in any media (e.g. print, CD-ROM, Internet, etc.) contained within this catalogue - also in an abridged form - is only allowed with our explicit written permission. We assume no liability for typographic errors and obvious mistakes. Please quote the relevant item numbers when making enquiries or placing an order. Delivery conditions are regulated in the General Terms and Conditions of Securiton AG for Export Deliveries Securiton Product Catalogue 2015 LIST 3

How to read the catalogue Example of a typical entry for an item Type & Article Number Please quote this number when making an enquiry or ordering Cable clamp CLIC 17 62-8000300-00-00 Cable clamp for SEC 20 100 pieces per packaging unit. Material: Polyamid, halogen free 5 g Colour: Grey RAL 7035 Illustration Description and technical data 4 Securiton Product Catalogue 2015 LIST

1. Processor Units Control and Evaluation Unit RDT-Function for LIST controller Lcon SEC (Standard) 62-2000354-00-00 Lcon LB (with loop function) 62-2000355-00-00 Cable terminal unit with a sensor cable connection. The LIST controller is the central control unit and cable terminal processor for the SEC 20 sensor cable. With an ARM9 embedded processor and two peripheral processors it provides the evaluation and signalling. Detection and alarm threshold values can be differently programmed for up to 254 alarm sections. Used in pairs and enhanced with RDT function, LIST controllers LB guarantee full cable and device redundancy. Contact voltage: Supply voltage: Contact current: Input: Ambient temperature: Current draw at 24 V DC: 48 V DC / 32 V AC max 9,5 36 V DC 250 ma max. (resistive load) 1 x external reset (5 V 36 V DC) -5 C +70 C, Normal 175 ma Alarm 212 ma Max. 5 W Power consumption: Relay outputs: 1 Relay for fault (= active without power) 1 Relay each for alarm, pre-alarm and frost-alarm Dimensions (HxWxD): 482,6 x 43,6 x 313,5 Material: Aluminium Evaluation: 2,6 kg heat Lcon RDT Redundancy control: If a fully redundant system is required, two LIST controllers always work together in pairs. Both communicate with each other, both have the complete information, and if necessary take on the tasks of the other one (cable break, device failure). This function must be ordered separately. 62-4000306-00-00 I/P-Interface und Protocol Lcon I/P Modbus (Modbus TCP) 62-4000314-00-00 Lcon I/P IEC (IEC 60870-5-104) 62-4000314-01-00 Software function for LIST controller. Securiton Product Catalogue 2015 LIST 5

Relay Module RELMOD Relay module with 16 relays and 8 inputs. - Very low energy consumption - Coding Switch for module address (1 16) - Inputs to remotely activate revision-mode and to initiate alarm simulations - Inputs for external alarm- and fault-handling signals - Input to trigger timer-controlled deactivation of differential temperature monitoring 62-2000413-00-00 Contact voltage: 48 V DC / 32 V AC Contact current: 250 ma max. (resistive load) Supply voltage: 10 36 V DC Current draw at 24 V DC: 56 ma (Normal) 105 ma (Alarm) Power consumption: Max. 2,4 W Relay outputs: 16 x toggle contacts for alarm, pre-alarm, fault and frost-alarm (loop resistors may be inserted for closed-circuit monitoring) Optocoupler input: 8x electrically isolated, 5 28 V DC signals Ambient temperature: 0 C +70 C Dimensions (HxWxD): 167 x 113,3 x 66,2 mm Case material: Aluminium 0,61 kg Remote Display Unit RDU 316 Alphanumerical remote display, coloured background, 3 lines, 16 characters each, with menu-keys and common LEDs; RS 485 interface to communicate with a maximum of 31 SCU 800 control units; allow the identification of a sensor number in case of alarm - stores all messages incl. date & time - indicates messages with unit and sensor number, alarm zone - test mode, which gives the status of the sensors - clear text display in various languages 62-2000493-00-00 Current consumption 24V: Power supply: 40 ma (Normal) 100 ma (Alarm) 10... 36 V DC Protection class: IP 66 Ambient temperature: 0 C +60 C Dimensions (HxWxD): 110 x 140 x 60 mm Case material: glass-fiber reinforced polycarbonate 6 Securiton Product Catalogue 2015 LIST

2. Cable Cables List SEC 20/02 (Sensor spacing 2m) 62-2000385-00-00 SEC 20/04 (Sensor spacing 4m) 62-2000388-00-00 SEC 20/05 (Sensor spacing 5m) 62-2000389-00-00 SEC 20/08 (Sensor spacing 8m) 62-2000393-00-00 SEC 20/10 (Sensor spacing 10m) 62-2000394-00-00 "Can be used in a temperature range of -40 C to +120 C (briefly +200 C) and detects temperatures with a resolution of 0.1 C. Cable terminal processor and sensors communicate bi-directionally. The cable sheathing is marked with the sensor designations. Cable design: - Ribbon cable conductor, 4-core with mounted hybrid switches - Filling material with strain relief (for cable protection in the event of a fire) - Integrated aluminium shield - Outer sheath halogen-free and flame resistant Operating temperature: -40 C +120 C up to +200 C short term Measuring temperature: -40 C +200 C Cable diameter: Typ. 18 mm Flat conductor resistance: Typ. 85 Ω / km (single conductor) Sheath material: HM4 mixture, halogen free, flame retardan Typ. 0,45 kg / m Sheath colour: Grey Securiton Product Catalogue 2015 LIST 7

3. Accessories List Cable clamp Mounting device Mounting device CLIC 17 Cable clamp plastic for SEC 20 100 pieces per packaging unit Material: Polyamid, halogen free 5 g Colour: Grey RAL 7035 MDP 20 Cable clamp CLIC 17 with dowel and stainless steel screw. 100 pieces per packaging unit Colour: Grey RAL 7035 MDJ 40 Stainless steel clip, grade 1.4571, with stainless steel dowel and cable fastener. 62-8000300-00-00 62-4000319-00-00 62-4000329-00-00 Material: Stainless steel 100 g Connection Box CBO 20/0 (for two SEC20) Connection box between two sensor cables Protection class: IP66 Material: glass-fiber reinforced polycarbonate Colour: RAL 7032 grey Operating temperature: -30 C...+90 C 1.6 Kg Dimensions (HxWxD): 244x164x101 mm Spare parts: Description Type Art. No. Accessory Bag CBO 20/0 Acc 62-4000431-00-00 Screw for CBO CBO 20 Screw 62-6000653-00-00 62-2000534-00-00 8 Securiton Product Catalogue 2015 LIST

Connection Box CBO 20/1 (to link a SEC20 with a CC 20) 62-2000535-00-00 CBO 20/3 (to link up to three SEC with up to two CC20) 62-2000536-00-00 Box for the connection of sensor cable SEC 20, incl. connection module CCM with over-voltage-protection. Connection Cable Protection class: IP66 Material: glass-fiber reinforced polycarbonate Colour: RAL 7032 grey Operating temperature: -30 C...+90 C 1.6 Kg Dimensions (HxWxD): 244x164x101 mm Spare parts: Description Type Art. No. Accessory Bag CBO 20/1 Acc 62-4000432-00-00 Accessory Bag CBO 20/3 Acc 62-4000436-00-00 Accessory Bag CBO 20/3 Acc CCM 62-4000437-00-00 Screw for CBO CBO 20 Screw 62-6000653-00-00 CC 20 LISTEC supply cable 2x2x0.8, shielded, JE-H(ST)H E30, for an SEC 20 sensor cable If it is not possible to connect the sensor cable directly to the sensor control unit, the connection cable CC 20 can connect sensor control unit and sensor cable via the connection box. 62-8000341-00-00 Colour: red LIST cable tester LCT 20 Sensor and cable tester for LIST sensor cable SEC 20; for fast testing of LIST sensor cables immediately after installation or temporary storage. - USB connection - Battery operation - Aluminium housing with shoulder straps - Power supply unit Sensor address range: 0 1023 AC power adapter: Input: 100 240 V AC 50/60 Hz 0.5 A Output: 15 V DC, 1200 ma Operating temperature: -10 C +60 C Dimensions (HxWxD): 206,0 x 168,0 x 36,0 mm Case material: Aluminium 1,1 kg (including shoulder-strap) 62-2000417-00-00 Securiton Product Catalogue 2015 LIST 9

Power Supply PS 2402 (2A) 62-2000251-00-00 PS 2408 (8A) 62-2000252-00-00 Uninterruptable power supply, VdS approved; in wall mounted cabinet or as 19" sub-rack (6 height units) available Fibre optic converter Mains voltage: 230 V AC +10/-20% Mains frequency: 47 63 Hz Output voltage: Typ. 27,6 V DC at 20 C Output current: 2A version Max. 2,3 A 8A version Max. 8,4 A Operating temperature: -5 C +50 C Relative humidity: Max. 95% at 40 C (No condensation) Dimensions (HxWxD): 230,0 x 150,0 x 54,0 mm (power supply module only) 478,0 x 266,0 x 63,0 mm (mounted on 19 front-panel, w = 19, h = 6U) 0,5 kg power supply module only 2,0 kg mounted on 19 front-panel Front-panel colour: RAL 9002, grey-white FOC 485 Interface converter for RS 485 to fibre optic, single and multi. Operating voltage: 18... 32 VDC (typ. 24 VDC) Current consumption: 140 ma at 24 VDC, 110 ma at 32 VD Power consumption: < 3,5 W Signal type: RS 485 Operating temperature: -25 ºC to +70 ºC Relative humidity: <95% (non-condensing) Dimensions (WxHxD): 35 x 163 x 119 mm Case material: plastics 215 g Protection class: IP 20 62-8000369-00-00 10 Securiton Product Catalogue 2015 LIST

Optical fibre converter FOC LAN-multi (multi-mode) 62-8000370-00-00 LAN-single (single-mode) 62-8000371-00-00 Interface converter for LAN to fibre optic Operating voltage: 24 V DC ( 18-32V) Current consumption at 24 V: 315 ma Operating temperature: 0 C.+ 60 C Storage / transport temperature: -40 C...+ 70 C Relative humidity: 10% - 95% (non-condensing) Dimensions: 71 mm x 131 mm x 111 mm 0,4 kg Housing: Plastic case Protection class: IP20 Wall mounted cabinet CAB 19/12 (12HE) 62-2000415-00-00 CAB 19/18 (18 HE) 62-2000416-00-00 19" wall cabinet, completely wired, incl. terminals. For holding a LIST controller, two relay modules, PS 24xx power supply unit and a fibre optic converter Spare parts: Crimping tool Description Type Art. No. Accessory Bag CAB 19 Acc 62-4000418-00-00 Wall mounting holder for CAB 19/x CAB WallHold 62-6000666-00-00 CLCT LIST crimping tool for 2-and 4-core flat cable connectors. 62-8000347-00-00 LIST cable cutter Cutter SEC Cable scissors for SEC sensor cable 62-0000427-00-00 Securiton Product Catalogue 2015 LIST 11

Service case SC 15/20 Service case with tool for repair and connection of sensor cable. 62-2000432-00-00 Content: Article Tool case 1 Installation guidelines SEC 20 (60T157-0x) 1 Sensor cable repair (60T032) 1 LIST-Crimping tool, adjusted 1 Cable cutter 1 Cable knife 1 Cable-stripping knife 1 Selection of 6 screwdrivers 1 Size 3 electronic screwdriver 1 Electronic side cutter 1 Side cutter 1 Multigrip pliers 1 Combination pliers 1 Clincher male CLS4 15 Clincher female CLB4 15 Clincher strain relief CLVS 15 Shield connector SEC 20 10 End cap END 20 2 Clamp Clic Top 17 10 CCM modul SEC 20 1 Sleeve SEC 20 2 Isolating tape 1 Tape to vulcanize 1 Quantity 12 Securiton Product Catalogue 2015 LIST

4. Spare Parts Connection Cable VKSEC-S4-KL-03 Pre-assembled connecting cable for connection to sensor cable. 62-4000239-00-00 Length: 3 m Connection Cable VK485-S4-KL-03 Pre-assembled connecting cable for RS 485 connection. 62-4000240-00-00 Length: 3 m Connection Cable VK232-S4-KL-03 Pre-assembled connecting cable for RS 232 connection. 62-4000241-00-00 Length: 3 m Connection Cable VKI/O-S4-KL-03 Pre-assembled connecting cable for control I/O connection. 62-4000242-00-00 Length: 3 m Connection Cable VK24-S4-KL-03 Pre-assembled connecting cable for power supply. 62-4000243-00-00 Length: 3 m Connection Cable VKLAN-S4-PC-03 Pre-assembled connecting cable for LAN connection. 62-8000367-00-00 Length: 3 m Line monitoring pcb RELMOD-R To hold the loop resistors 62-4000143-00-00 Securiton Product Catalogue 2015 LIST 13

Fuse for RELMOD RELMOD-F Fuse for RELMOD, 1 A, 250 V, fast 62-6000377-00-00 Shield Connector Flat cable connector Clincher Strain Relief End device Repair-set Connection Module Drill SDS 3L Setting tool SCON 20/1 (one sensor cable) 62-4000317-00-00 SCON 20/2 (two sensor cables) 62-8000382-00-00 For connecting sensor cables CLB 4 (socket) 62-8000317-00-00 CLS 4 (plug) 62-8000318-00-00 Ribbon cable crimping connector, 4-core. 100 pieces per packaging unit. CLVP For locking a CLB clincher with pin plug. 100 pieces per packaging unit END End cap for sensor cable SEC 15 N20 Repair Shrink sleeve with ribbon cable connection, shield connector, plug and socket, and sealing material. For connecting two SEC 20 cables. 62-8000320-00-00 62-8000503-00-00 62-2000397-00-00 CCM 3000 62-4000334-00-00 CCM 3000_D (with over-voltage protection) 62-4000335-00-00 Connection module for one or two sensor cables SEC 20 as junction between sensor cable and connection cable CC 20. SDS 3L Drill for setting the MDJ 40 dowels SWM-SM 50 Setting tool for MDJ 40 dowel (for hammer drill) 62-8000354-00-00 62-8000412-00-00 Setting tool SWM-H Setting tool for MDJ 40 dowel (for manual mounting) 62-8000413-00-00 14 Securiton Product Catalogue 2015 LIST

5. Services SecuriSens LIST Commissioning Europe Commission EU Commissioning support fee for projects within Europe. SecuriSens LIST Commissioning Overseas Commission OvS Commissioning support fee for projects at Overseas. 11-5000001-01-01 11-5000002-01-01 Securiton Product Catalogue 2015 LIST 15

6. Product Type Index C CAB 19 Acc... 11 CAB 19/12... 11 CAB 19/18... 11 CAB WallHold... 11 CBO 20 Screw... 8, 9 CBO 20/0... 8 CBO 20/0 Acc... 8 CBO 20/1... 9 CBO 20/1 Acc... 9 CBO 20/3... 9 CBO 20/3 Acc... 9 CBO 20/3 Acc CCM... 9 CC 20... 9 CCM 3000... 14 CCM 3000_D... 14 CLB 4... 14 CLCT... 11 CLIC 17... 8 CLS 4... 14 CLVP... 14 Cutter SEC... 11 E END... 14 F FOC 485... 10 L LAN-multi... 11 LAN-single... 11 Lcon I/P IEC...5 Lcon I/P Modbus...5 Lcon LB...5 Lcon RDT...5 Lcon SEC...5 LCT 20...9 M MDJ 40...8 MDP 20...8 N N20 Repair... 14 P PS 2402... 10 PS 2408... 10 R RDU 316...6 RELMOD... 6 RELMOD-F... 14 RELMOD-R... 13 S SC 15... 12 SCON 20/1... 14 SCON 20/2... 14 SDS 3L... 14 SEC 20/02... 7 SEC 20/04... 7 SEC 20/05... 7 SEC 20/08... 7 SEC 20/10... 7 SWM-H... 14 SWM-SM 50... 14 V VK232-S4-KL-03... 13 VK24-S4-KL-03... 13 VK485-S4-KL-03... 13 VKI/O-S4-KL-03... 13 VKLAN-S4-PC-03... 13 VKSEC-S4-KL-03... 13 16 Securiton Product Catalogue 2015 LIST

Securiton Product Catalogue 2015 LIST 17

18 Securiton Product Catalogue 2015 LIST