Headquarters & Technical Support 1958 Steam Way, Round Rock, TX (800) Mon Fri 7:00 7:00 CST Fog-Free Mirrors

Similar documents
ThermaSol PowerPak Series Installation & Operating Instructions Commercial Steam Bath Generators (Three Phase)

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

Installation Instructions Day Spa Generator

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

Wall Mount Electric Fireplace

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

Ducoterra Radiant Heating Panel Installation Manual

Installation Instructions PRO SERIES

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

IMPORTANT INSTRUCTIONS READ & SAVE

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

One Touch Control Installation and Operation Instructions

POWER PAK 480V Commercial Steam bath Generator

ELECTRIC FLAT PANEL FIREPLACE HEATER

QCM979D-38AGO ELECTRIC FIREPLACE HEATER NDF-65NB-3 INSTRUCTION MANUAL

COM-PAK COM-PAK TWIN. Com-Pak/Com-Pak Twin Heater. Owner s Guide. tested to UL standards PERFECTLY SIMPLE WARMTH FOR ANY ROOM

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

READ AND SAVE THESE INSTRUCTIONS

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

ELECTRIC FLAT PANEL FIREPLACE HEATER

IMPORTANT SAFETY INFORMATION:

FLCH4R Garage and Utility Electric Heater

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL

IMPORTANT INSTRUCTIONS READ & SAVE

50 FLAT PANEL BUILD IN ELECTRIC FIREPLACE

IMPORTANT INSTRUCTIONS READ & SAVE

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Elite Control Installation and Operation Instructions

M650-38A-OAK ELECTRIC FIREPLACE HEATER NDF-65NB-1 INSTRUCTION MANUAL

IMPORTANT INSTRUCTIONS READ & SAVE

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

Wall Hanging Mode. Pedestal Mode

AMBIANCE LINEAR 40 AMBIANCE LINEAR 60 AMBIANCE LINEAR 100 SAFETY INFORMATION AND OPERATIONS MANUAL

EF5802R Freestanding Electric Fireplace

ELECTRIC FIREPLACE HOMEOWNER'S MANUAL WALL MOUNTED FREE STANDING MODEL NO

Model: M630-44FDC CAUTION:

VERNON ELECTRIC FIREPLACE

MILLA ELECTRIC FIREPLACE

MODELS HS 1500-OWO HS-1500-OTR INFRARED ELECTRICAL HEATER SAFETY INSTRUCTIONS & OPERATION MANUAL

MODELS HS 1300-WS HS-1500-CR HS-1300-TR

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

FA433300TX. Electric Wall Fireplace. Assembly Instruction

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL

mr.steam Lexington Collection Feel Good Inc. REFER TO INSTALLATION, MAINTENANCE MANUAL PROVIDED WITH PRODUCT FOR COMPLETE INSTRUCTIONS

With Remote Control. English

PERSONAL SIZE FIREPLACE

VENTILATION FAN WITH LIGHT AND HEATER

Electric OmnipanelII Towel Radiator

Thanks for shopping with Improvements! Springfield Compact Electric Fireplace Item #470279

MP BB. ElEcTrIc FIrEplAcE HEATEr. INSTrUcTION MANUAl ATTENTION:

Gallery Electric Fireplaces

Signature Series Control

Thanks for shopping with Improvements! Quartz Comfort Furnace Heater Item #470295

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

Com-Pak Heater Benefits You Can Depend On Com-Pak Models Line Model w/o Model w/ Voltage Thermostat Thermostat Watts Amps (1) (2)

VERNON ELECTRIC FIREPLACE

EF5528RKD Freestanding Electric Fireplace

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

IMPORTANT INSTRUCTIONS

INSTRUCTION MANUAL Heavy Electric Utility Heater Model HA24-50E HA24-75E

Please Keep This Manual For Future Reference REV.01

IMPORTANT SAFETY INFORMATION:

With Remote Control. English. Model

R Series B & T2 Model

Hardwired Electric Garage Heater

OPERATING MANUAL CUSTOMER SERVICE NO

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Amazon Decorative Electric Fireplace with On Screen Display

LANDSCAPE FULLVIEW SERIES MODEL 4015 MODEL 6015 MODEL 8015 MODEL MODEL SAFETY INFORMATION AND OPERATIONS MANUAL

Installation Instructions and Homeowner's Manual

HI Industrial Utility Heater HI Soleus Air International

Installation Instructions Preference Wall Mount Range Hood

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

PRACTICAL USER S GUIDE FOR THE CORNER WALL MOUNTED ELECTRIC FIREPLACE

Ceramic heater FAN. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

Electric Fireplace Instruction Manual

user manual Model #: BLZ-HOOD

Landscape Fullview Series LFV SH LFV SH LFV SH LFV SH LFV SH

Solaira ICR Series H3

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

LAVA. Installation Manual. Design Glass-Radiator By WarmlyYours. Read all instructions before installing or using this heater.

Outdoor Electric Patio Heater

Modernist Warming Drawer

OWNER'S MANUAL DIGITAL OIL FILLED RADIATOR HEATER WITH REMOTE CONTROL ITEM NO.: MG-MTOH907L. 120V ~ 60Hz 1500W

Installation Instructions and Homeowner's Manual

OWNER S MANUAL CARTER FIREPLACE. Product code: UPC code: Date of purchase: / /

Electric Garage Heater

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

40 Built-in Electric Fireplace Operating and Installation Instructions

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Monaco Wall Mount Vertical Style LED Fireplace

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

Home Fire CBI Electric Series HF36CBI HF42CBI HF60CBI

Homeowner s Installation Instructions & Operating Manual

Homeowner s Installation Instructions & Operating Manual

Installation & Maintenance Instructions

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Transcription:

Headquarters & Technical Support 1958 Steam Way, Round Rock, TX 78665 (800) 776-0711 Mon Fri 7:00 7:00 CST www.thermasol.com Fog-Free Mirrors Installation Instructions Please read and follow the instructions completely before beginning installation. WARNING: All work must be done to National and Local Electrical codes. Rhombus Eclipse Avant Cupola 12.5 x 17 14.25 x 22 12.5 x 22 12.5 x 22 Parts Enclosed: Fog-Free Mirror (Mirror weight 8 lbs. (3.6 kg)) Assembled mirror with heating pad Transformer wiring: 120V Input (black-white), 12V Output (red-blue) 2 Solder-less connectors Materials needed: 18 gauge wire Clear silicone Drill 1 - ¼ drill bit 1 5/8 drill bit 2 - # 10 self-tapping screws 2 - # 10 anchors 81161 1 OF 6 REV B 01/15 JWJ

IMPORTANT INSTRUCTIONS WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDING THE FOLLOWING: 1) READ ALL INSTRUCTION BEFORE INSTALLING AND USING THIS MIRROR. 2) THIS HEATER IS HOT WHEN IN USE. TO AVOID BURNS, DO NOT LET BARE SKIN TOUCH HOT SURFACES. 3) EXTREME CAUTION IS NECESSARY WHEN ANY HEATER IS USED BY OR NEAR CHILDREN OR INVALIDS AND WHENEVER THE HEATER IS LEFT OPERATING AND UNATTENDED. 4) DO NOT OPERATE ANY HEATER AFTER IT MALFUNCTIONS. DISCONNECT POWER AT SERVICE PANEL AND HAVE HEATER INSPECTED BY A REPUTABLE ELECTRICIAN BEFORE REUSING. 5) TO DISCONNECT HEATER, TURN CONTROLS TO OFF, AND TURN OFF POWER TO HEATER CIRCUIT AT MAIN DISCONNECT PANEL (OR OPERATE INTERNAL DISCONNECT SWITCH IF PROVIDED). 6) USE THIS HEATER ONLY AS DESCRIBED IN THIS MANUAL. ANY OTHER USE NOT RECOMMENDED BY THE MANUFACTURER MAY CAUSE FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS. 7) THIS DEVICE IS FOR INDOOR USE ONLY. 8) TURN OFF POWER AT THE CIRCUIT BREAKER PRIOR TO BEGINNING WORK ON THIS INSTALLATION. WHEN DRILLING HOLES FOR MIRROR, MAKE SURE THERE ARE NO ELECTRICAL WIRES OR PLUMBING PIPES DIRECTLY BEHIND THE DESIRED HOLE LOCATIONS. 9) YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A WET APPLICATION. SLIPPING AND FALLING INTO THE MIRROR ITSELF WILL CAUSE SERIOUS PHYSICAL INJURY. 10) THERMASOL DOES NOT KNOW WHAT MATERIAL THE MIRROR WILL BE MOUNTED ON. THEREFORE, IT IS IMPORTANT THAT THE INSTALLER CREATE A STURDY AND SAFE ANCHOR. IF THE MATERIAL THERMASOL HAS SPECIFIED TO MOUNT THE MIRROR WILL NOT PROVIDE A STURDY AND SAFE ANCHOR FOR YOUR PARTICULAR INSTALLATION, THEN PLEASE SUBSTITUTE SUITABLE MATERIAL. 11) MAKE SURE THERE IS NO INSULATION OR COMBUSTIBLE MATERIAL WITHIN 8 INCHES OF THE TRANSFORMER. NO MATERIAL SHOULD TOUCH THE TRANSFORMER. 12) NEVER USE ANY SURFACE CLEANERS THAT DO NOT APPLY TO GLASS SURFACES. 13) TO REDUCE THE RISK OF FIRE DO NOT STORE OR USE IN THE VICINITY OF FLAMMABLE LIQUIDS OR VAPORS. SAVE THESE INSTRUCTIONS 81161 2 OF 6 REV B 01/15 JWJ

INSTALLATION INSTRUCTIONS WARNING: Must be wired, connected and all work must be done to National and Local Electrical codes. 1. Drill two 1/4 Dia. Holes 9-11/16 apart at a desired height on wall. Refer to figure #1. Insert PLASTIC anchors to reinforce holes. Use two 1-1/2 - #10 pan head screws for mounting the mirror. Screw the flat head screws into the anchors leaving ¼ protruding. ***WHEN DRILLING HOLES FOR MIRROR, MAKE SURE THERE ARE NO ELECTRICAL WIRES OR PLUMBING PIPES DIRECTLY BEHIND THE DESIRED HOLE LOCATIONS.*** 2. Find the center between the two mounting holes you just made. Measure down 3 ½, using a stud finder insure that there is not a stud located behind hole to be drilled. If there is, then offset to a location without stud interference, drill one 5/8 Dia. hole on the wall. Refer to figure 1. Figure #1 3. Mount the transformer in a location that is easily accessible for wiring and inspection. Mount in a bathroom vanity, located inside on the top where it is out of common contact. The power to the mirror should be connected to a switch, which may be turned on from outside of the shower enclosure. Such as a light switch or a dedicated switch. (Refer to diagram #2 and #3 for wiring with a switch) Because there are a wide variety of switches available to you, and we do not provide the switch, refer to your specific switch installation instructions. 81161 3 OF 6 REV B 01/15 JWJ

WARNING: Make sure there is no insulation or combustible material within 8 inches of The transformer. NO material should touch the transformer. Figure #2 Use the proper Crimping tool for solderless connectors: WT1455, WT2000, WT105M, ERG-2001, ERG-2003. Figure #3 4. You will need to supply 18-gauge wire to connect and extend blue and red transformer wires. Pull the wires through the hole, leaving roughly 1.5 feet extra out from wall for maneuverability and ease of installation. 5. Connect the mirror to the transformer by crimping the two wires from the mirror (with solder-less connections on ends) to the two transformer wires now coming through the 5/8 drill hole. 6. Cover the plug located on the wires from the mirror with silicone and gently push the wires and crimped connections into the 5/8 hole and insert the plug into hole, sealing the hole with silicon while mounting mirror. 7. Transformer is to be mounted in remote location. Make sure mounting location is a dry well ventilated space. DO NOT MOUNT IN SHOWER. 8. To reduce the risk of fire do not store or use in the vicinity of flammable liquids or vapors. 81161 4 OF 6 REV B 01/15 JWJ

OPERATION 1. BEFORE USE ENSURE THE MIRROR IS INSTALLED PER THE INSTRUCTION MANUAL. 2. IF THESE STEPS ARE FOLLOWED, YOUR FOG-FREE MIRROR WILL BE A PLEASURE TO LOOK AT AND USE FOR MANY YEARS. 3. TRANSFORMER IS MOUNTED IN REMOTE LOCATION AND IS TURNED ON AND OFF WITH A SWITCH LOCATED OUTSIDE THE SHOWER AREA. 4. TRANSFORMER IS INSTALLED TO ENSURE THE SAFETY OF THE USER. DO NOT TAMPER WITH. 5. YOUR MIRROR MAY REQUIRE PERIODIC CLEANING WHEN DIRTY. 6. MAKE SURE BREAKER IS OFF AND MIRROR IS COOL TO THE TOUCH PRIOR TO ANY CLEANING/SERVICE. 7. USE A GLASS CLEANING SOLUTION SUCH AS WINDEX AND A SOFT CLEAN COTTON CLOTH TO CLEAN THE MIRROR. NEVER USE ANY SURFACE CLEANERS THAT DO NOT APPLY TO GLASS SURFACES. 8. TO PREVENT WATER SPOTS, USE A SOFT CLEAN COTTON CLOTH AND WIPE THE MIRROR DRY BEFORE LEAVING BATHROOM. 9. IF YOUR MIRROR IS EVER REMOVED STORE IN THE FACTORY PACKAGING. 10. OTHER THAN NORMAL MAINTENANCE, ANY SERVICE SHOULD BE DONE BY QUALIFIED SERVICE TECHNICIAN. 81161 5 OF 6 REV B 01/15 JWJ

MAINTENANCE 1. YOUR MIRROR MAY REQUIRE PERIODIC CLEANING WHEN DIRTY. 2. MAKE SURE BREAKER IS OFF AND MIRROR IS COOL TO THE TOUCH PRIOR TO ANY CLEANING/SERVICE. 3. IF THESE STEPS ARE FOLLOWED, YOUR FOG-FREE MIRROR WILL BE A PLEASURE TO LOOK AT AND USE FOR MANY YEARS. 4. USE A GLASS CLEANING SOLUTION SUCH AS WINDEX AND A SOFT CLEAN COTTON CLOTH TO CLEAN THE MIRROR. NEVER USE ANY SURFACE CLEANERS THAT DO NOT APPLY TO GLASS SURFACES. 5. TO PREVENT WATER SPOTS, USE A SOFT CLEAN COTTON CLOTH AND WIPE THE MIRROR DRY BEFORE LEAVING BATHROOM. 6. OTHER THAN NORMAL MAINTENANCE, ANY SERVICE SHOULD BE DONE BY QUALIFIED SERVICE TECHNICIAN. Headquarters & Technical Support 1958 Steam Way, Round Rock, TX 78665 (800) 776-0711 Mon Fri 7:00 7:00 CST Failure to follow all instructions will void the warranty. 81161 6 OF 6 REV B 01/15 JWJ