UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

Multipoint Technical Data

Unvented water heating

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

2015 PRODUCT RANGE GUIDE

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Electromax. Combined electric boiler and domestic hot water store

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

HOTFLO 10 / 15. Fitting Instructions and User Guide

HOTFLO 10 / 15. Fitting Instructions and User Guide

Unvented Electric Water Heater 10/15 litre Undersink

Ventilation Product range ADVANCE ECO 4 ECO 2

MEGAFLO HE Iss 1

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

Installation and User Instructions HS10U, HS15U.

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

Megaflo eco Unvented hot water cylinders

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

VENTED POINT-OF-USE HOT WATER PRODUCT RANGE

Unvented Water Heating. Zircon

Hand Hygiene. September 2015 EV Instantaneous Handwash

Megaflo eco Unvented hot water cylinders

MULTIPOINT SS H 50/80 & 100

Cylinders & Water Heaters

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Megaflo eco. Unvented hot water cylinders

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

H o t Wa te r Syste m s. Unvented Copper Hot Water Cylinders for Heat Pump and Solar Input. Exceeding the Standard

Water. Heating. Connect with the Best. Electric Showers Power Showers 324. Shower Pumps 324. Beverage Water Dispensers

Exceeding the Standard

Exceeding the Standard

Streamline Undersink. Fitting Instructions and User Guide

MULTIPOINT 30 & 50 Litre

Solar thermal domestic hot water system

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

Regulations, Legislation and Byelaws

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

SMART HOT WATER SOLUTIONS PRODUCT RANGE

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Stored Water District Heating Interface Units. Heat Interface Units

Unvented water heaters

SOLAR HEATING SYSTEMS

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

Unvented Direct & Indirect Hot Water Cylinders

Megaflo Eco Unvented Direct & Indirect Solar Hot Water Cylinders

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

ELECTRIC HEATING SOLUTIONS PRODUCT RANGE

Water Heating Systems

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Unvented Direct & Indirect Hot Water Cylinders (400L L)

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

Packaged Solutions. Basic Packages

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: MonoWave single-coil and DuoWave twin-coil unvented heat pump cylinders

Megalife Solar Vented Cistern Fed Water Heater Installation manual

Megaflo Eco Slimline Unvented Direct & Indirect Hot Water Cylinders 100L - 200L

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

Megaflo Eco Solar PV Ready Unvented Direct & Indirect Hot Water Cylinders 170L - 300L

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Megalife Vented Cistern Fed Water Heater Installation manual

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

maximise the sun s energy with warmflow solar Warmflow Solar

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

Series 1000 & Storage Water Heaters

SUPREME 140, 155, 170

Instructions for Use Installation and Servicing

Tristor MF. Installation Guide

Multipoint. Installation and User Instructions Instantaneous Hand Wash Models: EV 2008

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Express 50 Litres Installation, operation and maintenance manual

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Cylinders - Vented Water Heaters - Electric Water Heaters - Domestic 314

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Installation & Technical Guide. Domestic & Commercial.

Installation Manual EXCELSIOR Unvented Water Heater

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Unvented Copper Hot Water Cylinders

THERMOSTATIC SHOWER VALVE

UNVENTED STAINLESS STEEL CYLINDERS

Transcription:

Unvented point of use hot water

Many different types of large commercial and industrial organisations need a reliable supply of hot water for up to 0 basins or sinks and we have developed the Multipoint range specifically to meet this demand. Multipoint can be adapted to suit standard or mixer taps and fed from the mains water supply provides high hot water flow rates. Flexibility when it comes to siting means there is no requirement for a cold water cistern. With the best possible performance, long-term reliability and corrosion-resistance in mind, our designers specify high-grade copper for the Multipoint s inner container. Using copper for this key component also means we don t have to fit a sacrificial anode avoiding the need for the hassle and expense of regular inspections and replacement. In addition, copper is better than lower grade materials at withstanding shock and vibration during delivery, installation and maintenance. The complete confidence we have in the quality of Multipoint s design and materials is proven by its five year inner container guarantee with on-site service support.

Multipoint 0 and 5 Multipoint is the market-leading range of small unvented water s and is ideal for any situation where a single is required to service the needs of multiple outlets. Multipoint is supplied with a factory-fitted temperature and pressure relief, is quick and easy to install and is offered in a wide range of capacities and ratings. 0 and 5 litre capacities. hoice of kw and kw ratings. Five year inner container guarantee with on-site service support. Replaceable long-life alloy sheathed element. Externally adjustable thermostat from 0 to 70 max. Lockable in hot or mid-range position. F/HF free (OP zero) flame-retardant expanded polystyrene. Element On indicator. No anode to inspect or replace. Suitable for use with any standard mixer or tap. Fitted with metre of -core cable. omprehensive installation IPX4 rated. E and kiwa approved to UK Water Supply Regulations. E marked. ccessories supplied with all units Factory-fitted temperature and pressure relief. Easy-fit wall-mounting bracket. ischarge funnel (tundish). Service. Optional accessories See pages 8 and 9. Multipoint 0 and 50 Multipoint 0 and 50 are ideal for commercial applications such as cloakrooms, kitchens or washrooms, where a single is required to service multiple draw-offs. The 50 litre product may also be used for single point showering. Versions of both products are available with kw elements for use in locations where electrical loading is restricted (horizontal unit kw only). Multipoint 0 and 50 are supplied complete with necessary installation accessories. thermostatic blending can also be used. See page 9 for details. s with all unvented units above 5 litres, it is a uilding Regulation requirement that installers are competent to install Multipoint 0 and 50 litre units. This normally means having successfully completed a course in unvented systems. For details on training courses call 0845 00 7402 or 02 8509. 0 and 50 litre capacities. hoice of kw and kw ratings. Horizontal versions available. Five year inner container guarantee with on-site service support. Factory-fitted temperature and pressure relief. Heavy gauge copper inner container. Replaceable long-life alloy sheathed element. Externally adjustable thermostat from 5 to 75 maximum lockable in hot or mid-range position. F/HF free (OP zero) insulation. Element On indicator. No anode to inspect or replace. Suitable for use with any standard mixer or tap. Fitted with metre of -core cable. omprehensive installation IPX4 rated. E and kiwa approved to UK Water Supply Regulations. E marked. ccessories supplied with all units Easy-fit wall-mounting brackets. ischarge funnel (tundish). ombined pressure reducing with built-in strainer. Expansion vessel and fixing bracket(s). Pressure relief (expansion). Optional accessories TMV2 and TMV thermostatic blending s see page 9. 4 5

Multipoint 75 and 00 Ideal for commercial applications such as cloakrooms, kitchens or washrooms, where a single is required to service multiple draw-offs. oth products may also be used for single point showering and are available with kw rating (2x kw elements) for use in locations where faster hot water recovery is required. s with all unvented units above 5 litres, it is a uilding Regulation requirement that installers are competent to install Multipoint 75 and 00 litre units. This normally means having successfully completed a course in unvented systems. For details on training courses call 0845 00 7402 or 02 8509. 75 and 00 litre capacities. hoice of kw and kw rating. Factory-fitted temperature and pressure relief s. Twin heavy gauge copper inner containers. Replaceable long-life alloy-sheathed elements. djustable thermostats from 5 to 75 maximum. Suitable replacement for cistern-type water s where improved water flow is required. F/HF free (OP zero) insulation GWP. (Global Warming Potential). Element On indicator. No anodes to inspect or replace. Suitable for use with any standard mixers or taps. Fitted with metre of -core cable. omprehensive installation E and kiwa approved to UK Water Supply Regulations. E marked. Five year on-site parts and labour inner container guarantee with on-site service support. Items supplied factory fitted to 75 and 00 litre models Expansion vessel. Pressure relief (expansion). Temperature & pressure relief s. Items supplied loose ombined pressure-reducing with built-in strainer. Tundish. Mounting brackets. Optional accessories TMV2 and TMV thermostatic blending s see page 9. 2 2 7 2 4 5 8 0 9 Expansion vessel. 2 Pressure relief. Non-return. 4 Thermostats. 5 Safety cut-outs. Element plate assemblies. 7 Element. 8 Inlet. 9 ischarge. 0 Outlet. able entry. 2 Temperature and pressure relief s. Water expands by up to 4% when heated (see Fig. ). This means that the design of the water and the installation in which it is used are critical. onventional (vented) and unvented systems allow for expansion in different ways. Fig. Expansion % 5 4. 4 2.2 0 0 20 0 40 50 0 70 80 90 00 Temperature rise º With unvented systems there are no cistern tanks or open outlets to accommodate expansion. ll systems above 5 litre, and some systems of 5 litre or less, employ an expansion vessel or an internal air-gap to accommodate expansion. With larger systems (above 5 litre) expansion is accommodated either by a separate expansion vessel or an internal air-gap. Multipoint 75 and 00 litre units use an expansion vessel which is supplied factory fitted within the casing. ll units above 5 litres are supplied complete with all the necessary components and controls to provide a safe and efficient method of providing stored mains pressure hot water in compliance with the latest building regulations. High-grade copper is used for the Multipoint inner container because of its optimum performance in terms of durability and corrosion resistance. opper requires no sacrificial anode and therefore avoids the need for regular inspection and replacement. Unlike other lesser grade materials, it also withstands shock and vibration during delivery, installation and maintenance. uilding Regulations irect connection to the cold mains supply has been permitted in the UK since 987. ll units above 5 litres must be installed to meet the requirements of the uilding Regulations. It is a legal requirement that the local uilding ontrol Officer is notified of any proposed installation of unvented water heating systems over 5 litre capacity. Products up to 500 litres and 45kW must be approved by a recognised body such as kiwa and be fitted by an installer who has successfully completed a recognised course in the installation of unvented heating systems such as those offered at our in-house training centres. all 0845 007402 for further information. Requirements call for an expansion space (internal or external), safety devices to prevent the stored water exceeding 99, and pipework to convey discharged hot water safely away from the safety devices. 7

ccessories Multipoint 0 and 5 Multipoint 0 and 5 ll Multipoint models an expanded water be accommodated in the pipework without hot water entering any supply pipe to which a cold water draw-off is connected? (i.e. at least 2.8m of 5mm pipe for 0 litre unit and 4.2m for 5 litre unit) re there any check s, stop s with loose jumpers or fittings that prevent reverse flow? No pack required iagram Is mains pressure 4. bar or less? Fit packs U + U2 iagram Is mains pressure 4. bar or less? Fit packs U2 iagram 2 Fit packs U + U2 iagram iagram For inlet water pressure up to 4. bar (0psi). Factory-fitted temperature and pressure relief Hot Factory-fitted temperature and pressure relief Hot old Multipoint 0 litre or 5 litre old Multipoint 0 litre or 5 litre Factory-fitted temperature and pressure relief Hot old Multipoint 0 litre or 5 litre 2.8 (0 l) or 4.2 (5 l) metres is required for expansion in pipework Pressure relief (expansion) T piece Pressure relief (expansion) T piece Expansion vessel heck Expansion vessel heck Nearest cold draw-off Nearest cold draw-off Nearest cold draw-off Pressure reducing Service (Fixed Jumper or /4 Turn all type) iagram 2 For inlet water pressure up to 4. bar (0psi) where expansion down the mains is not possible. iagram For inlet water pressure over 4. bar (0psi). old mains feed Service old mains feed Service old mains feed Note: If pressure reducing is used, expansion down the mains is not possible. full range of accessories are available for installation with Multipoint 0 and 5. These are supplied as accessory packs. Thermostatic blending, Pack U (TMV2) and Pack U7 (TMV), can also be used with Multipoint 0 and 50 litre units. When installing small unvented water s, it is essential that the correct accessory packs are used. The selection guide on page 8 indicates the appropriate pack(s) for different s and situations. If the expansion in the cold main is restricted, for example by a stop, check or water meter, an accessory pack which includes an expansion vessel must be fitted. See diagrams 2 and on page 8. knowledge of the maximum incoming water pressure is an essential requirement prior to installation; where this is not known the local Water uthority should be consulted. Pack U ombined pressure reducing and strainer The pressure reducing limits water pressure to.5 bar (50 psi). The strainer filters coarse impurities from the water supply. onnection /2" SP female. Installation Pack U must be installed on the cold inlet side of the and before the expansion vessel. Where possible, installation should be on the mains side of the cold water tap draw-off. This will result in balanced water supplies and is particularly important when mixers are to be used. Pack U must be used with Pack U2. Pack U2 Expansion vessel and check The expansion vessel when fully charged, will absorb all expanded water produced by the Hotflo during normal operation. onnection /2" SP male; precharged 4. bar. The check prevents backflow of hot water and eliminates any possibility of crosscontamination between cold and hot water. onnections 5mm compression. Installation Pack U2 must be fitted on the inlet side and in close proximity to the as shown in diagram 2 and on page 8. Thermostatic blending s allow water to be stored at high temperatures and blended with cold water to a preset outlet temperature. This provides over-temperature protection, and is ideal for the control of Legionellae and the extension of system capacities. Pack U TMV2 onnection 5mm compression. llows water to be safely stored above 0. Precisely controls outlet water temperature (range from 5 to 0 ). Lockable control knob. Fail-safe shutdown. Incorporates check s to prevent cross contamination. Operating pressure from 0.2 bar to.0 bar. Pack U7 TMV onnection 5mm compression. Fully approved under the TMV scheme to the O8 specification. llows water to be safely stored above 0. Precisely controls outlet water temperature (range from 8 to 4 ). Unique adjuster key to prevent unauthorised temperature adjustment. Fail-safe shutdown. Incorporates check s to prevent cross contamination. Operating pressure from 0.2 bar to 5.0 bar. Installation diagram and advice Heatrae Sadia offers a dedicated Specification dvice Team to provide information and advice on specification and installation. This is supported by a fully-trained national sales team, all of whom are qualified to provide further guidance and support locally. Outlet taps Hot outlet old mains feed lended water to outlets alanced cold water supply Pack U or U7 blending Water 8 9

Full specifications imensions and ordering Specification apacities 0, 5, 0, 50, 75 and 00 litre. Rating Multipoint 0 and 5 kw, kw @ 240V, (2.8kW, 4.kW @ 20V). Multipoint 0 and 50 kw, kw @ 240V, 0.9kW, 2.8kW @ 20V. Multipoint 75 and 00 kw @ 240V (2x.5kW), (2.8kW @ 20V (2x.4 kw)). kw @ 240V (2x kw), (5.kW @ 20V (2x 2.8 kw)). Outer casing Multipoint 0 and 5 White plastic top moulding with steel base and centre section finished in white stove enamel. Multipoint 0, 50, 75 and 00 White plastic top and base mouldings with steel centre section finished in white stove enamel. Thermal insulation Multipoint 0 and 5 F/HF free (OP zero) flame-retardant expanded polystyrene. Multipoint 0, 50, 75 and 00 F/HF free (OP zero) flame-retardant expanded polyurethane. Water container Multipoint 0 and 5 Replaceable heavy gauge copper inner container, designed for bar (87psi) working pressure and type tested to 20 bar (290 psi). Multipoint 0 and 50 Heavy gauge copper. Type tested to 20 bar (290 psi). Multipoint 75 and 00 2x heavy gauge copper inner containers. Type tested to 20 bar (290 psi). Heat unit Replaceable, alloy sheathed rod-type element. Thermostat Multipoint 0 and 5 Rod-type externally adjustable from 0 to 70, lockable in hot or mid-range position. Multipoint 0, 50, 75 and 00 apillary-type, externally adjustable from 5 to 75. Safety features Multipoint 0 and 5 Factory-fitted temperature and pressure relief opens at 7 bar (00 psi) or 90. Resettable over-temperature cut-out. Multipoint 0, 50, 75 and 00 Manually re-settable thermal cut-out. Factory-fitted temperature and pressure relief set to operate at 7 bar and 90. node Not required. pprovals E and kiwa approved to UK water supply regulations. E marked. Manufactured in the UK in a S EN ISO 900:2000 registered factory. Electrical The unit must be permanently connected to the electrical supply through a double-pole linked switch with minimum breaking capacity suitable for the loading. Must conform to current IEE wiring regulations. Vertical models only. Installation Multipoint 0, 50, 75 and 00 must be installed by a competent person in accordance with local Regulations. England and Wales uilding Regulations G, Scotland Technical Standards P, N. Ireland uilding Regulations P5. Fixing Multipoint 0 and 5 Must be mounted in the vertical position with inlet / outlet at the top. Floor or wall-mounted (three screws / easy-fit wall bracket). Fixing Multipoint 0 and 50 vertical units Must be mounted in the vertical position with inlet/outlet at the bottom. Temperature and pressure relief fitted to the top of the. Wall-mounted by easy-fit wall bracket and spacers (supplied). Fixing Multipoint 0 and 50 horizontal units Must be mounted in the horizontal position with the inlet and outlet to the right of the. Temperature and pressure relief fitted to the left of the. Wall-mounted using brackets (supplied). Fixing Multipoint 75 and 00 Mounting brackets supplied loose. Must be mounted in the vertical position with inlet/outlet at the bottom. Temperature and pressure relief s factory fitted to the top of the. Plumbing Minimum water pressure 0.8 bar (2 psi). Multipoint 0 and 5 pressures above 4. bar (0 psi), Packs U and U2 must be used. Multipoint 0 and 50 accessories supplied with all units. Multipoint 75 and 00 discharges from tundish 22mm compression. onnections Heater 5mm copper tube tails. Tundish Inlet /2" SP male; outlet /4" SP female. Service 5mm compression. Safety discharge Multipoint 0 and 5 the temperature and pressure relief must be plumbed to discharge in a safe visible location. Multipoint 0 and 50 temperature and pressure relief and expansion must be plumbed to discharge in a safe visible location in accordance with the local regulations stated above (tundish supplied). Optional thermostatic blending ccessory Pack U and Pack U7 (see page 9) allows water to be stored at high temperature and blended with cold to a preset outlet temperature. Electrical The unit must be permanently connected to the electrical supply through a double-pole linked switch with minimum breaking capacity suitable for the loading. Must conform to current IEE wiring regulations. ccessories (supplied with all units) Tundish and service. Guarantee Multipoint is guaranteed for a period of five years and its immersion and thermal control for a period of two years from the date of purchase against faulty manufacture and materials provided that: It has been installed in accordance with the instructions contained in the installation manual and all relevant odes of Practice and Regulations in force at the time of installation. ny s or controls are of the recommended type. The unit has not been tampered with and has been regularly maintained as detailed in the fitting It has been used only for heating potable water. Within 0 days of installation the user completes and returns the certificate supplied along with proof of purchase to register the product. The unit is not guaranteed against damage by frost. The Multipoint immersion and thermal controls are guaranteed for a period of two years, from the date of purchase, with the exception of damage due to excessive scaling. Evidence of purchase and date of supply must be submitted. The guarantee will not be transferable. This guarantee does not affect your statutory rights. imensions 0 and 5 litre models 0 00 vertical pipe drop from tundish TOP imensions 0 and 50 litre models OTTOM 0 00 imensions 0 and 50 litre horizontal models 250 apacity Rating @240 Weight imensions 75 and 00 litre models Ordering guide Multipoint 75 Multipoint 00 Multipoint 0 Multipoint 0 Multipoint 5 Multipoint 5 Multipoint 0V Multipoint 0V Multipoint 0H Multipoint 50H Multipoint 75 Multipoint 75 Multipoint 00 Multipoint 00 055 22 729 729 40 40 824 982 apacity (litre) 75 00 Rating @ 240V (kw) Weight empty full (kg) (kg) 52.5 27.5 Product code 95:050:4 95:050:45 95:050:44 95:050:4 95:050:52 95:050:50 95:050:5 95:050:5 95:050:54 95:050:57 95:050:70 95:050:7 95:050:72 95:050:7 Multipoint 0 572 27 457 (litre) 0 (kw) empty full (kg) (kg).9.9 Supplied complete with external expansion vessel, combined pressure reducing and strainer, check, expansion, tundish and wall brackets. Multipoint 0 572 27 457 0.9.9 Multipoint 5 Multipoint 5 Multipoint 0V Multipoint 0V 728 728 788 788 27 27 70 70 52 52 5 5 0 0 8.8 2.8 8.8 2.8 2.5 42.5 2.5 42.5 ccessories ordering guide Product code Multipoint 0H Multipoint 50H 00 00 788 00 70 70 70 70 52 52 52 52 888 888 888 50 50 0 50 9. 9. 9. 9. 2.5 42.5 9. 9. ccessory pack U See page 9 for details ccessory pack U2 See page 9 for details ccessory pack U See page 9 for details ccessory pack U7 See page 9 for details 95:970:52 95:970:5 95:970:54 95:970:0 0

ontact Specification T: 00 420220 F: 00 420229 E: specifier@heatraesadia.com fter Sales Service T: 0844 87 55 F: 0844 87 528 E: heatraesadiaservice@heateam.co.uk Web www.heatraesadia.com National service network Heatrae Sadia products are inherently reliable and are designed to meet the demanding needs of all users. nationwide network of experienced engineers is available to provide fast and efficient on-site service support. In addition, spare parts for the complete range of products are readily available through a wide variety of stockists. rochures for all of our products are available free of charge. Please call our literature hotline on 00 42027. omestic Heating and Hot Water erheat mptec Electric Solar Electromax Electromax Solar Megaflo HE Megaflo Solar Megalife HE Showers ommercial Hot Water M / M Express FM Handy Handy ri and Hair rier Hotflo Immersion Heaters Multipoint Streamline UT 99 rinking Water Superhill Supreme Heatrae Sadia Heating Hurricane Way Norwich Norfolk NR E Heatrae Sadia Heating may introduce modifications to their products from time to time. onsequently, the details given in this brochure are subject to alteration without notice. 95 900 908 Issue Heatrae Sadia Heating. 2009. This product is printed on 50% post consumer recycled paper. That is paper that has been previously used eg. newspapers and magazines. This product is printed using vegetable based inks which are non toxic. Please recycle this product once you have finished with it.