ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Similar documents
MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

14 AC x

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

2 shp 13 lc 1 36 t - 1 a

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

T S A 048 S 4 N 4 1 T

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

T P A 120 S 4 S N 1 Y

T P A 048 S 4 N 4 1 T

ELITE Series R-410A - Two-Stage Compressor

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

Visit us at For the latest technical information,

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

ELITE Series Variable Capacity

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

MERIT Series R-410A - Upflow / Horizontal

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

ELITE Series Variable Capacity

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

13 GEP A L P - 1 A

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

RGE 13 A T - 1 A

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

C22FC Bulletin # October 1993 Supersedes May 1993

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

XC21. DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

Commercial High-Efficiency Condensing Units

Ruud Achiever Series Air Conditioners

Commercial High-Efficiency Condensing Units

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL SPECIFICATIONS

C22 Bulletin # October 1993 Supersedes May 1993

Lennox 8 Series Single Zone - R-410A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL SPECIFICATIONS

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

PACKAGE AIR CONDITIONER

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

MACH N-407 Heat Pump Air-Cooled Chiller

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton

PAJ3. Product Specifications

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

16 SEER TWO-STAGE AIR CONDITIONERS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

INSTALLATION INSTRUCTIONS

XC13. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R410A.

PRODUCT SPECIFICATIONS

CB X 32 mv

RSG16**S1M. Split System Air Conditioner 16 SEER

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

ELITE SERIES Downflow - High Efficiency Blower Motor

WCH5**4. Product Specifications

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

R4H4. Product Specifications

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

Corp L2 Revised

TECHNICAL SPECIFICATIONS

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

MAC N-407 Air-Cooled Chiller

13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A.

SPLIT-SYSTEM CONDENSING UNITS. "HRC" Series SEER. Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

Transcription:

PRODUCT SPECIFICATIONS AIR CONDITIONERS EL6XC ELITE Series R-40A Bulletin No. 20833 July 208 Supersedes March 208 SEER up to 7.90.5 to 5 Tons Cooling Capacity - 7,800 to 60,000 Btuh MODEL NUMBER IDENTIFICATION Product Tier EL = Elite Series EL 6 X C - 036-230 A 0 Revision Level Nominal SEER 6 = 6 SEER Ratings Revision Level Refrigerant Type X = R-40A Voltage 230 = 208/230V- phase-60hz Unit Type C = Air Conditioner (Condenser) Cooling Stages = Single Stage Compressor Regional Standards (dash) = All Regions S = Southeast and North Regions Nominal Cooling Capacity 08 =.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 04 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 060 = 5 tons

FEATURES CONTENTS Dimensions - Unit... 9 Electrical Data... 6 Features... 2 Field Wiring... 8 Installation Clearances... 8 Model Number Identification... Optional Accessories... 6 Outdoor Sound Data... 8 Specifications... 6 TXV/Orifice Usage... 0 NOTE! For the latest AHRI System Matches please see the Residential Matchup Tool at www.lennoxpros. com or see the separate document AHRI Air Conditioner Matches that contains all outdoor unit matches. WARRANTY Compressor - limited warranty for ten years in residential installations and five years in non-residential installations. All other covered components - five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AHRI Certified to AHRI Standard 20/240-2008. Sound rated in Lennox reverberant sound test room in accordance with test conditions included in AHRI Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated according to U.S. Department of Energy (DOE) test procedures. Region specific models meet the minimum efficiency requirements for U.S DOE Federal Regional Standards in that area. Air conditioners and components within bonded for grounding to meet safety standards for servicing required by UL and CEC. Units are ETL certified for the U.S. and Canada. ISO 900 Registered Manufacturing Quality System. For expanded ratings, see www.lennoxpros.com. Certain Energy Star certified units are designed to use less energy, help save money on utility bills, and help protect the environment. H B D APPLICATIONS.5 through 5 ton. E I Sound levels as low as 7 db. Single-phase power supply. F C G Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI System Matches. See Indoor Coils and Air Handlers sections for data. Units shipped completely factory assembled, piped and wired. Each unit test operated at the factory ensuring proper operation. Installer must set air conditioner, connect refrigerant lines and make electrical connections to complete job. EL6XC -.5 to 5 Ton Air Conditioner / Page 2

FEATURES B C D E REFRIGERATION SYSTEM R-40A Refrigerant Non-chlorine, ozone friendly, R-40A. Unit pre-charged with refrigerant. See Specification table. Outdoor Coil Fan Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has sleeve bearings and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion. Fan guard constructed of corrosion-resistant PVC (polyvinyl chloride) coated steel. Fan service access accomplished by removal of fan guard. Lennox Quantum Coil Enhanced aluminum alloy tube/enhanced fin coil for superior corrosion resistance. Lennox designed and fabricated coil. Ripple-edged aluminum fins. Aluminum tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections. Coil is factory tested under high pressure to insure leakproof construction. Entire coil is accessible for cleaning. High Capacity Liquid Line Drier Approved for use with R-40A systems. Traps any moisture or dirt that could contaminate the refrigerant system. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Auto-reset. Discharge Thermostat Factory installed on the discharge line of the compressor. SPST, auto-reset Removes power from the compressor when discharge temperature exceeds the factory setting of 220ºF. Refrigerant Flow Control Units applicable to expansion valve systems or RFC systems when matched with specific indoor coils. RFCIV: Accurately meters refrigerant in system. Refrigerant control is accomplished by exact sizing of refrigerant metering orifice. The principle involves matching indoor coil with proper bore size of orifice in metering device. Equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating need for additional controls. Furnished with air conditioner. Optional Accessories Expansion Valve Kits Must be ordered extra and field installed on certain indoor units. See TXV/Orifice Usage table. Chatleff-style fittings. O RING Freezestat Installs on or near the vapor line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint. Opens at 29 F and closes at 58 F. Loss of Charge Switch Kit Helps protect the compressor from damage due low refrigerant charge conditions. SPST, normally-closed switch, automatic reset switch mounted on suction line. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. Suction line fully insulated. Lines are stubbed at both ends. RFCIV METERING SYSTEM ORIFICE BODY RFCIV (On Coil) LIQUID LINE SCREEN SEAL NUT Not available for -060 models and must be field fabricated. ORIFICE LIQUID LINE SWEAT CONNECTION EL6XC -.5 to 5 Ton Air Conditioner / Page 3

FEATURES F COMPRESSOR Scroll Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on specially formulated, resilient rubber base for improved sound dampening and vibration-free operation resulting in quieter operating sound levels. See Outdoor Sound Data table for details. Compressor Crankcase Heater (060 Models) Protects against refrigerant migration that can occur during low ambient operation. Factory Installed. Optional Accessories Compressor Crankcase Heater (08 thru 048 models) Protects against refrigerant migration that can occur during low ambient operation. Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally doesn t need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. Compressor Low Ambient Cut-Off Switch Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35 F. CONTROLS Optional Accessories Indoor Blower Off Delay Relay Delays the indoor blower-off time during the cooling cycle. See AHRI System Matches for usage. Low Ambient Kit Air conditioners operate satisfactorily down to 45 F outdoor air temperature without any additional controls. Low Ambient Control Kit can be field installed, allowing unit operation down to 30 F. Crankcase heater and freezestat should be installed on compressors equipped with a Low Ambient Kit. A compressor lock-out thermostat should be added to terminate compressor operation below recommended operation conditions Thermostat Thermostat not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book. Compressor Timed-Off Control Kit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize. Permits compressor start-up in an unloaded condition. Automatic reset with 5 minute delay between compressor shut-off and start-up. Compressor Sound Dampening System A polyethylene compressor cover containing a 2 inch thick batt of fiberglass insulation for better sound dampening. All open edges are sealed with a one-inch wide hook and loop fastening tape. EL6XC -.5 to 5 Ton Air Conditioner / Page 4

G H I FEATURES CABINET Heavy-gauge steel construction Pre-painted cabinet finish. Control box is conveniently located with all controls factory wired. Corner patch plate allows access to compressor components. Drainage holes are provided in base section for moisture removal. High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture. PermaGuard Unit Base Durable zinc-coated base section resists rust and corrosion. SmartHinge Louvered Coil Protection Steel louvered panels provides complete coil protection. Panels are hinged to allow easy cleaning and servicing of coils. Panels may be completely removed. Interlocking tabs and slots assure tight fit on cabinet. Refrigerant Line Connections, Electrical Inlets and Service Valves Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See dimension drawing. EL6XC -.5 to 5 Ton Air Conditioner / Page 5

SPECIFICATIONS General Data Connections (sweat) Model No. All Regions EL6XC-08 EL6XC-024 EL6XC-030 EL6XC-036 Southeast and North Regions - - - - - - - - - EL6XCS036 Nominal Tonnage.5 2 2.5 3 Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8 Suction line (o.d.) - in. 3/4 3/4 3/4 7/8 Refrigerant R-40A charge furnished 4 lbs. 9 oz. 4 lbs. 9 oz. 5 lbs. 8 oz. 7 lbs. oz. Outdoor Coil Outdoor Fan Net face area - sq. ft. Outer coil 3.22 6.33 2.00 6.33 Inner coil - - - - - - - - - 5.75 Tube diameter - in. 5/6 5/6 5/6 5/6 No. of rows 2 Fins per inch 26 26 26 22 Diameter - in. 8 22 22 22 No. of blades 3 3 3 3 Motor hp /0 /6 /6 /6 Cfm 2290 360 360 360 Rpm 075 825 825 825 Watts 60 25 25 90 Shipping Data - lbs. pkg. 55 7 87 205 ELECTRICAL DATA Line voltage data - 60hz 208/230V-ph 208/230V-ph 208/230V-ph 208/230V-ph 2 Maximum overcurrent protection (amps) 20 25 25 30 3 Minimum circuit ampacity.9 4.6 7 8.0 Compressor Rated load amps 9.0 0.9 2.8 3.6 Locked rotor amps 48 59.3 67.8 79 Power factor 0.97 0.97 0.97 0.96 Outdoor Fan Motor Full load amps 0.7 OPTIONAL ACCESSORIES - ORDER SEPARATELY Locked rotor amps.3.9.9.9 Compressor Crankcase Heater 93M04 Compressor Hard Start Kit Copeland 0J42 LG 88M9 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Timed-Off Control 47J35 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M8 Loss of Charge Switch Kit 84M23 4 Low Ambient Kit (Fan Cycling) 34M72 Refrigerant Line Sets L5-4-20 L5-4-30 L5-65-30 L5-4-40 L5-4-50 L5-65-40 L5-65-50 NOTE - Extremes of operating range are plus 0% and minus 5% of line voltage. Refrigerant charge sufficient for 5 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL6XC -.5 to 5 Ton Air Conditioner / Page 6

SPECIFICATIONS General Data Connections (sweat) Model No. All Regions EL6XC-04 EL6XC-042 EL6XC-047 EL6XC-048 EL6XC-060 Nominal Tonnage 3.5 3.5 4 4 5 Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8 3/8 Suction line (o.d.) - in. 7/8 7/8 7/8 7/8 -/8 Refrigerant R-40A charge furnished 9 lbs. 9 oz. 8 lbs. 2 oz. lbs. 0 oz. 9 lbs. 2 oz. 2 lbs. 0 oz. Outdoor Coil Outdoor Fan Net face area - sq. ft. Outer coil 2.00 2.00 22.7 2.00 29.09 Inner coil 20.25 20.25 2.33 20.25 28.6 Tube diameter - in. 5/6 5/6 5/6 5/6 5/6 No. of rows 2 2 2 2 2 Fins per inch 22 22 22 22 22 Diameter - in. 22 22 26 22 26 No. of blades 3 3 4 4 3 Motor hp /6 /6 /3 ¼ /3 Cfm 3050 3050 4400 3600 4550 Rpm 825 825 825 825 825 Watts 90 90 30 30 30 Shipping Data - lbs. pkg. 227 234 272 255 284 ELECTRICAL DATA Line voltage data - 60hz 208/230V-ph 208/230V-ph 208/230V-ph 208/230V-ph 208/230V-ph 2 Maximum overcurrent protection (amps) 30 40 35 40 50 3 Minimum circuit ampacity 9.3 23.4 2.9 24.2 29.6 Compressor Rated load amps 4.7 7.9 6. 8.0 22.2 Locked rotor amps 75 2 05.5 7 27.9 Power factor 0.96 0.96 0.98 0.96 0.98 Outdoor Fan Motor Full load amps.8.7.8 Locked rotor amps.9.9 2.9 3.2 2.9 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Compressor Hard Start Kit 93M06 Factory Copeland 0J42 LG 88M9 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Timed-Off Control 47J35 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M8 Loss of Charge Switch Kit 84M23 4 Low Ambient Kit (Fan Cycling) 34M72 Refrigerant Line Sets L5-65-30 L5-65-40 L5-65-50 Field Fabricate NOTE - Extremes of operating range are plus 0% and minus 5% of line voltage. Refrigerant charge sufficient for 5 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL6XC -.5 to 5 Ton Air Conditioner / Page 7

OUTDOOR SOUND DATA Unit Model No. Octave Band Linear Sound Power Levels db, re 0-2 Watts Center Frequency - HZ 25 250 500 000 2000 4000 8000 Sound Rating Number (db) EL6XC-08 55 6 67 68 63.5 59 50.5 72 EL6XC-024 55 62 67.5 66.5 63 59 52.5 72 EL6XC-030 54 6.5 66 66 62 57 5 7 EL6XC-036 / EL6XCS036 56 66 69 67 62.5 57.5 50.5 73 EL6XC-04 54.5 62.5 67.5 67 62.5 58.5 52.5 72 EL6XC-042 55.5 62.5 68 67 62 57.5 5.5 72 EL6XC-047 55 62 67 66.5 62.5 57.5 49.5 72 EL6XC-048 55.5 64.5 70 7 65 60.5 54 75 EL6XC-060 55.5 62.5 67 66.5 62.5 60 53.5 73 NOTE - the octave sound power data does not include tonal correction. Tested according to AHRI Standard 270-2008 test conditions. FIELD WIRING DISCONNECT SWITCH (By Others) THERMOSTAT (Optional) DISCONNECT SWITCH (By Others) B LENNOX AIR CONDITIONER C D A LENNOX HEATING UNIT OR AIR HANDLER UNIT A - Two Wire Power (not furnished) B - Two Power (not furnished). See Electrical Data C - Four Wire Low Voltage (not furnished). 8 ga. minimum D - Five Wire Low Voltage (not furnished). 8 ga. minimum All wiring must conform to NEC or CEC and local electrical codes. INSTALLATION CLEARANCES - INCHES (MM) See NOTES NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. See NOTES See NOTES Clearance to one of the other three sides must be 36 in. (94 mm) Clearance to one of the remaining two sides may be 2 in. (305 mm) and the final side may be 6 in. (52 mm). See NOTES Control Box A clearance of 24 in. (60 mm) must be maintained between two units. 48 in. (29 mm) clearance required on top of unit. EL6XC -.5 to 5 Ton Air Conditioner / Page 8

DIMENSIONS - UNIT - INCHES (MM) SUCTION LINE CONNECTION TOP VIEW LIQUID LINE CONNECTION C DISCHARGE AIR B LIQUID LINE CONNECTION ELECTRICAL INLETS SUCTION LINE CONNECTION A 4 /4(08) 4 3/4 (2) 2 (5) SIDE VIEW (25) END VIEW UNIT SUPPORT FEET UNIT SUPPORT FEET 8 /2 (26) 9 /2 (24) D K 8 3/4 (222) 8 /4 (20) E J 5 /2 (40) 3 /2 (343) EL6XC-08 BASE SECTION (Small Base) F G EL6XC-024 TO -060 BASE SECTION (Medium and Large Base) H Model No. A B C D E F G H J K in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm EL6XC-08 3 787 27 686 28 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EL6XC-024 3 787 30-/2 775 35 889 3-7/8 352 7-3/4 97 3-/4 83 27-/8 689 3-5/8 92 4-/2 4 20-5/8 524 EL6XC-030 39 99 30-/2 775 35 889 3-7/8 352 7-3/4 97 3-/4 83 27-/8 689 3-5/8 92 4-/2 4 20-5/8 524 EL6XC-036 / 3 EL6XCS036 787 30-/2 775 35 889 3-7/8 352 7-3/4 97 3-/4 83 27-/8 689 3-5/8 92 4-/2 4 20-5/8 524 EL6XC-04 35 889 30-/2 775 35 889 3-7/8 352 7-3/4 97 3-/4 83 27-/8 689 3-5/8 92 4-/2 4 20-5/8 524 EL6XC-042 39 99 30-/2 775 35 889 3-7/8 352 7-3/4 97 3-/4 83 27-/8 689 3-5/8 92 4-/2 4 20-5/8 524 EL6XC-047 35 889 35-/2 902 39-/2 003 6-7/8 429 8-3/4 222 3-/8 79 30-3/4 78 4-5/8 7 3-3/4 95 26-7/8 683 EL6XC-048 39 99 30-/2 775 35 889 3-7/8 352 7-3/4 97 3-/4 83 27-/8 689 3-5/8 92 4-/2 4 20-5/8 524 EL6XC-060 45 43 35-/2 902 39-/2 003 6-7/8 429 8-3/4 222 3-/8 79 30-3/4 78 4-5/8 7 3-3/4 95 26-7/8 683 EL6XC -.5 to 5 Ton Air Conditioner / Page 9

TXV/ORIFICE USAGE Use this table for C35, CH23, CH33, CH35 and CR33 Field Installed TXV/Orifice Match-Ups. Model No. Refrigerant Metering Orifice (RFC) Order No. Orifice Size Thermal Expansion Valve (TXV) EL6XC-08 97M74 0.053 2J8 EL6XC-024 97M75 0.057 2J8 EL6XC-030 0W99 0.065 2J8 EL6XC-036 EL6XCS036 W02 0.073 2J9 EL6XC-04 97M77 0.074 2J20 EL6XC-042 97M78 0.076 2J20 EL6XC-047 0W86 0.080 2J20 EL6XC-048 W07 0.083 2J20 EL6XC-060 0M3 0.097 2J20 CX35 and CX38 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. If a change out is required it will be listed in the TXV SUBSTITUTIONS table. The correct TXV must be ordered separately and field installed. C35 and CH33 coils - Use the orifice shipped with the outdoor unit or replace the factory installed orifice with the expansion valve listed. CR33 and CH23 coils - Use the orifice shipped with the outdoor unit or use the expansion valve listed. CH35 coils - Factory installed orifice must be replaced with the expansion valve listed. MOST POPULAR MATCHES Outdoor Unit Model No. EL6XC-08 EL6XC-024 EL6XC-030 EL6XC-036 EL6XCS036 EL6XC-04 EL6XC-042 EL6XC-047 EL6XC-048 EL6XC-060 Indoor Unit Model No CX38-25B CX38-25B CX38-3B CX38-38B CX38-49C CX38-49C CX38-62C CX38-62C CX38-62C *TXV SUBSTITUTIONS Use this table to determine if the factory installed TXV in the indoor unit needs to be replaced. Model Indoor Coil or Air Handler Factory TXV AHRI STANDARD 20/240 Replacement TXV EL6XC-030 CX35-48 2J20 2J8 * CX35 coils - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used. Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 250 Btu/h per,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per,000 cfm of indoor air circulated. NOTE! For the latest AHRI System Matches please see the Residential Matchup Tool at www.lennoxpros. com or see the separate document AHRI Air Conditioner Matches that contains all outdoor unit matches. EL6XC -.5 to 5 Ton Air Conditioner / Page 0

REVISIONS Sections Description of Change Txv/Orifice Usage Chnaged orifice for EL6XC from 0.093 to 0.097. Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 208 Lennox Industries, Inc.