ESP TECHNOLOGIES LIMITED

Similar documents
Model A1600 Series Annunciator

4 & 8-POINT ANNUNCIATORS Instruction Manual

TECHNICAL DATA OBSOLETE

RTD TEMPERATURE SENSING SYSTEM

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Rack Mount Series Installation Guide

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AO Annunciator Module

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

EXTINGUISHING AGENT RELEASE MODULE

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

20 Light Remote Annunciator

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

AIS750 Series Alarm Annunciator

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

Model 4001 Series Single Channel Controller

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Installation Guide for models:

RELEASE DEVICE CONTROLS

Installation, Operating and Maintenance Manual

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

AL800ULADA. NAC Power Extender. Installation Guide

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Soft Start Series MP700 Solid State, Reduced Voltage

Installation Guide for models:

Specification/ Data Sheet

ESSEX ENGINEERING CORPORATION

SFC-200 SERIES LED FIRE ALARM PANEL

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

INSTALLATION AND INSTRUCTION MANUAL

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

OPTICAL TURNSTILE SYSTEM

Electric Release Panel Wiring Tips

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Pioneer-R16 Gas Monitor Operator s Manual

Intelligent Security & Fire Ltd

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Beacon 800 Gas Monitor Operator s Manual

Door Release Power Supply

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

RAM3 Remote Alarm Module

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

MR-2602 Two Zone Fire Alarm Control Panel

MODEL B2 INSTALLATION MANUAL

FEC400 Series. Installation Manual

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

30.45 Electric Release PDRP-2001

Instruction Manual. CMP-12/24 Fire Alarm Control Panel. 12 Clintonville Road, Northford, CT DOCUMENT /11/96 REV: D1

X11CA COMPUTER ANNUNCIATORS

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Monitoring Devices 11/1

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Across-the-Line SERIES MP300 Combined Manual and Automatic

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Control and Annunciator Panels. Compact systems of signalling and control

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Beacon 410A Gas Monitor Operator s Manual

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

Model A1700 Series Annunciator

4100U City and Relay Cards Installation Instructions

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

LMA LINE MONITOR ALERT USER S MANUAL

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

DGC-1000 DIGITAL GENSET CONTROLLER

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

DH100ACDCI Ionization Air Duct Smoke Detector

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

DH100ACDCI Ionization Air Duct Smoke Detector

INSTALLATION INSTRUCTIONS

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Series. Access Power Controllers. Installation Guide

Installation / Monitoring Technique

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Variable Frequency Drive SERIES MP800 VFD

Instructions for the fan motor control system with integrated wiring terminals SILVER C

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Commercial and Light Industrial Fire Alarm Control Panel

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Model 4880 Status Output Display Module Manual

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Transcription:

Alarm Technology ESPAN-01 Series Annunciator System Combination type User Manual (Rev. 1) ESP TECHNOLOGIES LIMITED www.esptechno.com

Content Page Introduction 2 General Description 2 Overview - Annunciator System 3 Specifications 4 Master Alarming Module 6 Parameters Setting 7 Circuit Wiring Diagram 9 Power Supply Unit 10 Installation 11 Typical Wiring Diagram 14 Dimension 15 Procedure for factory repairing and returning 17 ESPAN01 Series User Manual (Rev. 1) 1 www.esptechno.com

Introduction The Annunciator system ESPAN-01 series incorporate the latest microprocessor technology to provide a versatile and flexible alarm system suitable for a wide range of applications. The basic system consists of a power supply unit, master alarm unit and window display units. The power supply unit is a universal AC or DC converter which can accept both AC and DC source with the wide range but the output shall be DC 24 V. The master alarm unit, normally have six ranges : 16 alarm point, 24 alarm point, 32 alarm point, 40 alarm point, 48 alarm point and 56 alarm module depended on demand selection. The layout of the window display module is flexible according to the requirement. The sizes of the window display units are as following: 30 x 30 and 30 x 60 mm. Lamp inside the window display unit can be LED or incandescent lamp upon request. The master alarm unit is a modern technology using microprocessor based and solid state designed. All setting parameters can be easily done via selector or dip-switch on the control card. General Description Optimizing an industrial installation requires automation of control and is usually accompanied by an alarm or supervisory system of certain parameters called fault. The aim is to attract the attention of the supervising personnel by an illuminated signal and alarm horn or buzzer, thus enabling proceeding to be taken. Rapid detection of any anomaly or excess of critical values will avoid unfortunate consequences, which could result from lack of interference. Item to be Horn/Buzzer Altered Fault Detector Alarm Sequence Definition of fault is expressed by the opening or closing of a contact. This information represents any modification of a physical or mechanical parameter converted into an electrical signal by the intermediary of a detector. ESPAN01 Series User Manual (Rev. 1) 2 www.esptechno.com

Overview - Annunciator System POWER SUPPLY MODULE ESPAN-01 COMBI- TYPE MASTER ALARM MODULE ESPAN ALARM TECHNOLOGY DISPLAYING MODULE LED LAMP OR INCANDESCENT ESPAN-02 SINGLE UNIT, LED TYPE (FLUSH MOUNT) ESPAN01 Series User Manual (Rev. 1) 3 www.esptechno.com

Specifications System Voltage Display Lamps : 24 Vdc + 10% Field contact voltage : (options) 24, 48, 110, 125 Vdc ± 10% Active alarm point : 16, 24, 32, 40, 48 & 56 (max) Temperature Range Storage : -10 to 70 C Operating : -10 to 55 C Humidity : up to 95% Power Source Input voltage : 110-350 Vdc or 90-250 Vac (50/60 Hz) Output voltage : 24 Vdc + 5% Output power : 30, 50, 75, 100, 150 & 300 Watt Output Lamp output : Flash light Audible alarm : Two channels output for audible alarm Repeat relay (option) : 24 Vdc Input coil, 1 output contact (rating: 10A 28 Vdc or 10A 120 Vac) Response time : 20 ms, nominal Display dimension Square window : 30 x 30 mm. (each - with one lamp supplied) Rectangular window : 30 x 60 mm. (each - with 2 lamps supplied) Power of display lamp : 2 watt/pc for incandescent lamp or 0.5 watt/pc for LED lamp ESPAN01 Series User Manual (Rev. 1) 4 www.esptechno.com

Sequence : Manual Reset Standard sequence : ANSI/ISA-S18.1-1981 (Annunciator sequences & specifications) STANDARD SIGNAL NORMAL ALERT RETURN TO NORMAL BEFORE ACKNOWLEDGEMENT ACK RESET RETURN TO NORMAL M-1-2-14 LAMP SOUND OFF SILENCE FLASH ALARM FLASH ALARM ON SILENCE OFF SILENCE OFF SILENCE Manual reset occurs after acknowledge when the process condition has turned to normal and the reset push button is pressed. Sequence : Automatic Reset Standard sequence : ANSI/ISA-S18.1-1981 (Annunciator sequences & specifications) STANDARD SIGNAL NORMAL ALERT RETURN TO NORMAL BEFORE ACKNOWLEDGEMENT ACKNOWLEDGEMENT BEFORE RETURN TO NORMAL RETURN TO NORMAL A-1-2-14 LAMP SOUND OFF SILENCE FLASH ALARM OFF SILENCE ON SILENCE OFF SILENCE Automatic reset occurs after acknowledge when the process condition has turned to normal. ESPAN01 Series User Manual (Rev. 1) 5 www.esptechno.com

Master Alarming Module Power consumption 1.8 Watt (at 24 Vdc) for 16 channel 2.0 Watt (at 24 Vdc) for 24 channel 2.2 Watt (at 24 Vdc) for 32 channel 2.4 Watt (at 24 Vdc) for 40 channel 2.6 Watt (at 24 Vdc) for 48 channel 2.8 Watt (at 24 Vdc) for 56 channel Alarming sequences Manual reset sequence (Lock-in type) In this mode, the momentary fault inputs will be latched until acknowledgement and reset to clear. Alarm device is silenced and stop flashing when acknowledged. Manual reset of acknowledge alarm can be done only after process conditions return to normal. Auto reset sequence (Non locking type) In this mode, the contacts return to normal on and acknowledge the alarm cause that alarm to reset. If alarm contact returns to normal before acknowledgement then the alarm will immediately reset on acknowledge. ESPAN01 Series User Manual (Rev. 1) 6 www.esptechno.com

Parameters Setting 1) Selecting Setup Menu 2) Flash Rate Setting 3) Operation Sequences Setting ESPAN01 Series User Manual (Rev. 1) 7 www.esptechno.com

4) NO NC Fault Contact Setting 5) Bell / Buzzer Output Alarm Setting ESPAN01 Series User Manual (Rev. 1) 8 www.esptechno.com

6) Circuit Wiring Diagram ESPAN01 Series User Manual (Rev. 1) 9 www.esptechno.com

Power Supply Unit This is an AC/DC converter regulated type, designed for surge protection and provides transient surge isolation between the station battery and the sensitive electronic components of the annunciator system. Fuse Protection is also protecting system from overload or short circuit on the output power supply. Model : PSU-30, 50, 75, 100, l50, 300 Output Power : 30, 50, 75, 100, 150 & 300 watt Efficiency : 85-95 % of full load Input Voltage (auto range) : 160 to 250 Vac : 110 to 350 Vdc Input Frequency : 47 to 440 Hz Temperature Range : 0 to 70 C Output Voltage : 24 ± 5% Vdc Output Ripple Voltage : ± 150 mv p-p (max) at full load Hold up time : 10 ms (min) at 24 V Designed for World Wide Operation Reference EMI : Meets VDE B (VFG243B) CISPR22 Class B Safety requirements : IEC 950 / UL1950 Hardware Protection (on board) Primary safety current limit Output short circuit protection Thermal shutdown protects entire power supply ESPAN01 Series User Manual (Rev. 1) 10 www.esptechno.com

Installation Mounting Display Unit to panel Insert the unit from the front side. From the back, attach the mounting clamp (CA-1) ion. Hook to the square hole of the frame board and screw tightly. Place the mounting clamps evenly around the display unit. Fasten with the recommended torque 0.4 ~ 0.5 Nm. For wiring, secure the application terminal with a terminal screw in accordance with the polarity indication. Removing the window displaying unit The window displaying unit consists of a lens, legend plate, filter and lamp. To remove lens, insert the tip of a Philip screw driver into the side space of the case and gently rotate then the lens will come off. Use the fingers or tool to remove the lamp out. ESPAN01 Series User Manual (Rev. 1) 11 www.esptechno.com

When mounting Insert the nameplate, filters and front lens into the lens retains. To mount the window display, place the unit perpendicularly against the case with the two legs section in the left and right side and push in along the way. ESPAN01 Series User Manual (Rev. 1) 12 www.esptechno.com

How to connect system +24V / 0V RES / ACK / TEST / COM / 125COM24 F01 ~ F16 ~ FX1~FX8 (MAX56) PWR OPER BUZZER BELL COM COM L01 ~ L16 ~ LX1 ~ LX8 (MAX56) 1) +24V/ 0V : Input voltage must be DC 24 Vdc : Positive connects to +24 V and Negative connect to 0 V. 2) RES : must be connected to the reset push button switch (RES) which is N.O. contact and the opposite side of the push button switch must connect to COM. ACK : must be connected to the acknowledged (ACK) push button switch and do the same as RES, the purpose is to do horn stop. TEST : must be connected to the lamp test (LT) push button switch and do the same as RES. The purpose is for lamp checking. COM : must be connected to the push button switch RES, ACK and TEST. 3) 125 COM 24 (Notice) In case of Fault input signal is DC +125 V, -125 V must connect to 125 COM In case of Fault input signal is DC +24 V, -24 V must connect to COM 24 4) F01~F16~F32~F56 : must be connected to fault input signal or field contact. 5) BUZZER / BELL : can be selected and connected to Buzzer or Bell outside via primary power source. 6) COM / COM : must be connected to the DC 24 V (Negative pole) 7) L01~L16~L32~L56 : connect to the lamp of window display unit by point and the opposite side of these lamps are common and connect to the DC +24 V (Positive pole). ESPAN01 Series User Manual (Rev. 1) 13 www.esptechno.com

Typical Wiring Diagram ESPAN01 Series User Manual (Rev. 1) 14 www.esptechno.com

Dimension of Master Alarming Unit ESPAN01 Series User Manual (Rev. 1) 15 www.esptechno.com

Dimension of displaying unit 30 x 30 Dimension of displaying unit 30 x 60 ESPAN01 Series User Manual (Rev. 1) 16 www.esptechno.com

Procedure for factory repairing and returning A. Prepare a Return Material Authorization Form (available from ESPAN or its local representative) with the following information: Model and Serial Number of the equipment. Specify Failure Symptom Operating Environment (indoor, outdoor, temperature, vibration, etc.) Approximate date of installation or number of operating hours. Name and telephone number of contact person if questions arise. B. Enclose the information with the equipment and pack in a commercially accepted shipping container with sufficient packing material to ensure that no shipping damage will occur. Ship to the appropriate location as below Attention: Service Department ESP Technologies Ltd. 688/74, M.7, Laksi-square Building, Changwattana Road, Anusaowari-Bangkhen, Bangkhen, Bangkok 10220, Thailand Telephone: +66(0)25226245~7 Fax: +66(0)25226248 C. Your equipments will be tested, repaired and inspected at the factory and return within ten days (exclude shipping back period). D. In case of urgent service needs or repairing status enquiry, please contact the appropriate Service Department or your local ESPAN representative. WARRANTY: ESP Technologies Ltd. warrants equipment of its own manufacture to be free from defects in material and workmanship, under normal conditions of use and service. ESP Technologies Ltd. will replace any components found to be defective, upon its return, transportation charges prepaid, within one year of its original purchase. ESP Technologies Ltd. will extend the same warranty protection on accessories, which is extended or implied, beyond its obligation to replace any components involved. Such warranty is in lieu of all other warranties expressed or implied. ESPAN01 Series User Manual (Rev. 1) 17 www.esptechno.com