FlexiPanel INSTALLATION PROCEDURES WITH MAINTENANCE AND TROUBLE SHOOTING GUIDE INSPECTION REPORT FORMS

Similar documents
Raychem Heating System

HEATRACE. Young Chang Silicone Ltd, Co. SELF-REGULATING PIPE TRACING HEATER CABLE. Installation, Operation & Maintenance Manual

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

Electric Heat Tracing INSTALLATION, MAINTENANCE, & TROUBLESHOOTING

SELF-REGULATING PIPE TRACING HEATER CABLE

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

Frost Heave Protection System Installation and Operation Manual

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

American Dish Service

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

KE-Series Constant-Wattage Heating Cable

NELSON HEAT TRACING SYSTEMS

Industrial Flanged Immersion Heaters

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Fire Sprinkler Freeze Protection Design / Install Guide

NELSON HEAT TRACING SYSTEMS INSTALLATION

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

HOTFOIL HB MODULE HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL HB.IOM.R3

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

XL-Trace System Installation and Operation Manual

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

ClimaGuard Outdoor Heat Exchanger All Models

SAFETY INFORMATION AND WARNINGS

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

DHCSR Series Drum / Pail Heaters

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Getting Started Quick Reference Guide

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

Design Guide and Installation Details for Self-Regulating Heating Cable

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Maintenance Manual WATER SLUG CONTROL SWITCH PART NUMBERS: F528 AND F528B

Consignes d installation

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

NELSON HEAT TRACING SYSTEMS

OPERATING AND MAINTENANCE MANUAL FOR PACKAGED ELECTRIC TEPID WATER HEATING SYSTEMS BASE MODEL ESS

MARATHON HEATER. File # E Made in USA

User s Information and Installation Instructions

Installation Instructions

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

Service Manual Model 3163

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

Flexible Heaters. of Silicone Rubber & Kapton

INSTALLATION & MAINTENANCE MANUAL PVI ELECTRIC HOT WATER SUPPLY BOILER

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Installation Instructions

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. I 2017 Pentair Equipment Protection P/N

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

FLT93 Installation, Operation and Troubleshooting Guide

INSTALLATION. For more information on this product or to order samples call or visit our website at builddirect.com.

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Service Handbook. Servicing should only be performed by a Qualified Service Agent.

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SEALING FIBER SEALING COMPOUND

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

NELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT

Public Safety DAS Annunciator Panel

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

T-Series Air Conditioner T15 Model

INSTALLATION AND SERVICE MANUAL

Otherwise, you can continue reading the file on the following pages.

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER. ELECTRIC HEATER COMPANY BASE MODEL SH and H

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

T-Series Air Conditioner T20 Model

Circulating Oil Temperature Control System

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

PLSRR Heat Trace Cable Data Sheet

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Sidel Combi-Combi Therm & CO2 Counter Installation Guide

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Transcription:

FlexiPanel INSTALLATION PROCEDURES WITH MAINTENANCE AND TROUBLE SHOOTING GUIDE INSPECTION REPORT FORMS

FlexiPanel Vessel Heating System The following installation procedures are suggested guidelines for the installation of Thermon s FlexiPanel system. They are not intended to preclude the use of other methods and good engineering or field construction practices. A copy of this manual accompanies each heater panel shipped. It is also available on the web at www.thermon.com. Receiving, Storing and Handling... 1. 2. 3. 4. Inspect materials for damage incurred during shipping. Report damages to the carrier for settlement. Shipping cartons are marked on the outside with the product description, sales order number and quantity. Compare information on shipping carton with packing slip and purchase order to verify receipt of correct shipment. Product should be stored indoors away from standing water; however, if outdoor storage is required, a protective covering should be used. Do not remove the heater from the carton until ready to install. Read all installation instructions prior to installing heater(s). Surface Preparation/Layout... 1. Surface area where the FlexiPanel is to be installed must be reasonably clean. Remove dirt, rust and scale with a wire brush and oil and grease film with a suitable solvent. Mill varnish and protective coatings may be removed with a suitable stripper. 2. FlexiPanels are typically 12 in width and vary in length up to 84. In general the heater is adhesively bonded to the lower exterior tank wall. The FlexiPanel should not extend above the vessel s normal minimum liquid level as this will result in higher operating sheath temperatures at the exposed heater area. Space FlexiPanels evenly around circumference of vertical vessels and along lower area of horizontal vessels. FlexiPanel Testing... 1. 2. 3. Prior to installation check each heater for proper resistance. Resistance values for standard FlexiPanel heaters are enclosed. Nominal resistance is V 2 /P (Voltage squared divided by Power) Example - 120V@1000 Watt = 120 2 /1000 or 14.4 ohms. The resistance window is +/- 10%. (13.0-15.8 ohms) Prior to installation check each heater for insulation resistance. 1000 Vdc megohmeter check for insulation resistance between the power wires and ground wire. On steel tanks repeat test between the power wires and steel tank. 20 megohms minimum after 60 seconds. Repeat these tests after installing heaters and after the insulation has been installed. FlexiPanel Attachment... 1. 2. 3. 4. 5. Plan for proper heater placement on the tank based on tank and heater sizes, tank obstructions, low liquid level and wiring routing requirements etc. FlexiPanels rely on good surface contact to maximize the heat transfer into the tank wall and product. Do not modify, overlap, cut or crease the heater. Heaters are typically bonded to the tank wall surface using adhesive supplied with the RTM Mounting Kit Part# W3073. An instruction sheet (Thermon dwg # 54A107S1) is supplied with the kit. The RTM Mounting Kit includes 2 each 10.3 oz tubes of RTV silicone sealant. One kit can install up to 8 square feet of heater. Additional tubes are available specify Part Number W20043 Silicone Sealant 10.3oz. Allow 0ne tube per 4 square feet of heater area. A roll of AL-20L tape is also included and installs up to 35 square feet of heater. Additional rolls of AL-20L are available - specify Part Number W400080. Photo: RTM Mounting Kit The outline of the heater is marked on the vessel using the marking pen. Load the adhesive tube into the caulking gun. Clip off end of threaded tip or puncture seal as applicable, install cartridge nozzle and cut ½ off the nozzle tip for proper bead size. A bead of adhesive is applied to the silicone heater layer at 2 spacing. In a similar manner apply adhesive to the marked area on the tank wall. Using the notched spreader immediately spread the adhesive on the heater and tank not exceeding 1/32. Be sure the entire surface area is covered. Position the heater in place. Do not allow the adhesive to skin over. Compress heater firmly in place onto the tank wall using the roller. Work out any air bubbles by running the roller over the backside of the heater from the center outward. Secure the heater to the tank using aluminum tape as required. If spray on foam type insulation is to be used seal all the edges of the heater with AL-20L tape to prevent lifting. Allow 24 hours for adhesive to cure before energizing. The RTM Mounting Kit includes 8 each Caution Labels to be secure to the exterior of the insulating shell to identify the tank as electrically heat traced. 2

INSTALLA LATI TION PRO ROCEDURES Final Connections... 1. 2. 3. 4. 5. FlexiPanel heaters are supplied standard with a T&B 5232 liquidtight flex conduit fitting exiting the top of the heater cap. The ½ liquidtight flexible conduit is supplied by others. Local junction boxes and thermostats are to be properly installed and supported. Connect conduit securely as required to keep enclosures dust-tight and water-tight. Area approved seal fittings when required are supplied by others. Carefully connect conduit to heater fitting without rotating the fitting. Use a wrench to keep the heater fitting from rotating while tightening. Use a wrench to keep the heater fitting from rotating. Tighten the cap nut first by hand and then with a second wrench with 25 ft-pounds of torque. Repeat heater resistance and insulation resistance tests after the heater is installed on the tank. This verifies the heater was not damaged during the heater installation. Make any corrections/ repairs/replacements. Tape or bond thermostat bulb or sensor onto the tank wall midway between heaters and away from any heat sinks at a level similar to the heaters. If a high temperature thermostat is used to monitor maximum bulk fluid temperature the thermostat bulb or sensor would be located on the tank wall similar to the control thermostat but at a higher temperature setpoint. If a high temperature thermostat is used to monitor maximum heater sheath temperature the thermostat bulb or sensor would be located directly on the backside of one heater in the circuit and set to a temperature above the normal operating temperature of the heater. Thermal Insulation... 1. 2. The need for properly installed and well maintained thermal insulation cannot be overemphasized. Regardless of the type or thickness of insulation used, a protective barrier should be installed. This protects the insulation from moisture intrusion, physical damage and helps insure the proper performance of the heat tracing system. Seal around all penetrations through the thermal insulation. Repeat heater resistance and insulation resistance tests after the installation of the thermal insulation and weather barrier. This verifies the heater was not damaged during the insulation installation. Make any corrections/repairs/replacements. System Operation... 1. 2. The heating system can be energized once the fluid level is above the heaters. Turn the circuit breaker on and with the control thermostat closed (set to a temperature higher than actual fluid temperature) record the voltage and current. Retain these readings as part of an ongoing maintenance program. Lower the setpoint on the control thermostat to below the actual fluid temperature to test that the thermostat will shut off the heaters. The microswitch will produce an audible click sound and the heater current will be zero. Set the control thermostat to the desired maintain temperature setpoint. 3 3. 4. 5. An overlimit or high temperature thermostat may be employed in the design to monitor the maximum allowable bulk fluid temperature or maximum allowable heater temperature. If designed to monitor the maximum bulk fluid temperature lower the setpoint of the high temperature thermostat below the actual fluid temperature to verify switch operation. The microswitch will produce an audible click sound and the heater current will be zero. Increase the setpoint to the design high temperature cutout setpoint. Note that the sensor is wall mounted and during normal operation this thermostat will always be in the closed position. If designed to monitor the maximum allowable heater temperature lower the setpoint of the high temperature thermostat below the actual heater operating temperature to verify switch operation. The microswitch will produce an audible click sound and the heater current will be zero. Increase the setpoint to the design high temperature cutout setpoint. Note that the sensor is mounted on the heater and during normal operation this thermostat will always be in the closed position. A liquid level below the heaters with the heaters energized is considered an upset condition and should be avoided or prevented unless the heating system has been specifically designed for this condition. In general the heater operating temperature is much higher without fluid to conduct heat away from the heater. Liquid level controls can be employed to cut off the power supply to the heating system during low liquid level conditions but this disables the heating system so it is best to consider the fluid level above the heaters as a system requirement for safe operation. The 2002 NEC requires Ground Leakage Equipment Protective Devices on all heat tracing circuits. Exception: Ground Leakage Monitoring and Alarms may prevent the need for branch EPD breakers. Electrical Heat Tracing caution labels should be applied to the outer surface of the weather barrier at regular intervals around the tank. 8 labels are supplied with the RTM Mounting Kit. Part# 27200 provides a package of 25 labels. Once the heat tracing system has been installed, an ongoing preventative maintenance program should be implemented using qualified personnel. Support documentation should be maintained which provides general information and an operating history of the specific circuits in the system.

FlexiPanel Vessel Heating System Insulation Resistance Test (IR Test) Description An Insulation Resistance Test (Megger) checks the quality of the heaters insulating layers by measuring the electrical insulation resistance of the system. The higher the reading the better the insulation resistance. A low reading may indicate potential failure and allow replacement during routing maintenance. To obtain comparable results tests are done for the same duration usually 60 seconds. Check heater insulation resistance before installation, after installation, after insulation is installed as as part of an annual preventative maintenance program. Record data in a maintenance log. An IR test should also be done if any work is done on the tank insulation or if the tank has been subject to damage. Equipment The test is performed with an instrument called a megohmmeter or Megger. Thermon recommends performing the test at 1000 Vdc. 500 Vdc is the minimum acceptable test voltage. Testing Tests are done with the heating equipment not connected to a power supply. On an installed system use the connections at the local junction box or splice box.disconnect the heater lead wires from the terminals and connect to Megger. Testing insulation layer between heater element and heater ground. Connect one lead to the heater power wires and the other lead to the heater ground wire. Set the voltage to 1000Vdc. Turn the Megger on. Apply test voltage for one minute. The minimum insulation resistance reading is 20 megohms. If the heater is installed on a nonmetallic tank the testing is complete. To test the insulation layer between heater element and metal tank r emove the negative lead from the ground wire and connect to the metal tank surface. Set the voltage to 1000Vdc. Turn the Megger on. Apply test voltage for one minute. The minimum insulation resistance reading is 20 megohms. Test Results For readings below 20 megohms recheck testing procedure. Look for correct connections and settings and that the heater is isolated from other electrical connections. Check for evidence of excess moisture, corrosion or damage to the heater or wiring.. Damaged heaters should be replaced. Insulation failure can result from excessive heat or cold, dirt, moisture, oil, corrosive vapors, vibration, aging, nicked wires or mechanical or electrical damage. FlexiPanel Cat. # Nominal Service Voltage (VAC) Nominal Power (Watts) Dimensions (Inches) Minimum -10% Nominal Resistance Maximum +10% RT-521 120 500 12 x 24 25.9 28.8 31.7 RT-522 240 500 12 x 24 103.7 115.2 126.7 RT-1021 120 1000 12 x 42 13.0 14.4 15.8 RT-1022 240 1000 12 x 42 51.8 57.6 63.4 RT-2022 240 2000 12 x 84 25.9 28.8 31.7 RT Special Up to 600V Up to 2 W/in2 As Specified -10% As Specified +10% RTF-1236 120 300 12 x 36 43.2 48.0 52.8 RTF-1260 120 500 12 x 60 25.9 28.8 31.7 RTF-1282 120 300 12 x 84 43.2 48.0 52.8 RTF-1284 120 500 12 x 84 25.9 28.8 31.7 RTF-2260 240 500 12 x 60 103.7 115.2 126.7 RTF-2284 240 500 12 x 84 103.7 115.2 126.7 RTF Special Up to 600V Up to 0.7 W/in2 As Specified -10% As Specified +10% FlexiPanel Cat. # Nominal Service Voltage (VAC) Nominal Power (Watts) Dimensions (Inches) Minimum -10% Nominal Resistance Maximum +10% 4

Single Heater / Phase to Phase or Phase to Neutral Power Supply 208V/240V N 120V/277V Control thermostat Bulb WIRING SCHEMATI TICS 120 volt Power Supply C NC 28.8 OHMS / 500 watts 28.8 OHMS / 500 watts Multiple Heater / Phase to Phase or Phase to Neutral Power Supply 208V/240V N 120V/277V Control thermostat Bulb 28.8 OHMS / 500 watts PARALLEL WIRING 120 volt Power Supply C NC 125 WATTS 125 WATTS 28.8 OHMS + 28.8 OHMS = 57.6 OHMS Multiple Heater / Contactor / Phase to Phase Heaters / Phase to Neutral Control Power Supply N A B 208V/240V HEATER SERIES WIRING REF: OHMS LAW V 2 /R=W Contactor Control thermostat Bulb 120V COIL C NC Sample Circuit - Control Thermostat and High Temperature Cutout Thermostat Power Supply N A B 208V/240V HEATER Contactor Control Thermostat Bulb High Temp Thermostat 120V Coil C NC C NC 5

FlexiPanel Vessel Heating System Maintenance and Troubleshooting Guide The following information is intended to assist you in maintaining and troubleshooting electric tank and vessel heating systems. The primary objective is to enhance your understanding of the elements of a successful heat tracing installation. Of these elements, one of the most important is thermal insulation. Before calling your heat-tracing vendor make a visual inspection of the installation; perhaps the thermal insulation is wet, damaged or missing. Also, consider that repairs or maintenance of in-line or nearby equipment may have resulted in damage to the heating equipment. These are common causes of heat tracing problems, and they are often overlooked. Other possible causes are listed below with their symptoms and remedies. Note: If you suspect that an electric heating circuit is damaged, we recommend a dielectric insulation resistance (megger) test be performed with a 1000 Vdc megohmmeter. See page 4 of this manual. Readings can be logged on Part 2 of the Thermon Inspection Report Form brochure. Periodic testing with accurate records will establish a normal range of operation, and dielectric insulation resistance readings, which deviate from the normal range, can quickly reveal a damaged circuit. Thermal Insulation... An Integral Part of Every Heat Tracing System The value of properly installed and well-maintained thermal insulation cannot be overemphasized. Without the insulation, the heat losses are generally too high to be offset by a conventional heat tracing system. Before the thermal insulation is installed on the tank or vessel, the heating circuit should be tested for dielectric insulation resistance. This will ensure that the heater has not been damaged while exposed on the uninsulated tank. There are many different tank insulation materials, each of which has advantages in particular applications. The temperature ratings of some of the common insulation materials are listed below in order of their efficiency (from the most to least effective), based on equivalent thicknesses: Polyurethane foam (180 0 F - 250 0 F) Rigid Fiberglass (375 0 F 500 0 F) Flexible Cellular Glass (400 0 F) Rigid Calcium Silicate (1200 0 F+) Rigid Regardless of the type or thickness of insulation used, a protective barrier should be installed. This protects the insulation from moisture intrusion and physical damage, and helps ensure the proper performance of the heat tracing system. Insulating materials such as fiberglass and calcium silicate are very susceptible to water absorption, which dramatically increases the heat lost. They should be replaced if they become wet. SYMPTOM I. No heat/no current POSSIBLE CAUSE REMEDY A. Loss of Power (Voltage) Restore power to the heating circuit. (Check circuit breaker and electrical connections.) B. Controller set point too low Adjust set point. C. High-temperature limit May require manual reset to switch activated re-enable heating circuit. Check set point. (Identify cause of high temperature- review design, check liquid level.) D. Open series heating circuit Repair or replace circuit. 1 E. Controller Failure Repair sensor or controller. 2 SYMPTOM Il. Low System Temperature POSSIBLE CAUSE REMEDY A. Controller Set Point Too Low Adjust set point. B. Temperature sensor located too Relocate sensor. close to heater or other heat source; may be accompanied by excessive cycling of control relays/contacts. C. Insulation material and/or Replace insulation; thickness different than designed. Increase insulation thickness (if dry); Consider increasing voltage 3 for higher heater output; Add additional heaters. D. Ambient temperature lower than Add additional heaters; designed Consider increasing voltage 3 ; Add additional insulation. E. Lower Voltage (Check at power Adjust voltage 3 to meet design Connection point) requirements. F. Liquid Level below heaters Increase liquid level; (Heaters cycling or deenergized) Lower heater location below low if tied into LLL switch) liquid level. 6

MAINTE NTENANCE E AND TROUBLESHOOTI TING GUIDE SYMPTOM III. I. High System Temperature POSSIBLE CAUSE REMEDY A. Controller on continuously Adjust set-point or replace sensor. 2 B. Controller failed with contacts Replace sensor or controller. 2 closed C. Sensor located near heat sink. Relocate sensor to an area representative of overall tank conditions. D. Backup heating circuit Adjust set-point or replace controller on continuously backup controller. Footnotes... 1 FlexiPanel heaters must usually be replaced if defect not found in heater wires. Note: FlexiPanel heaters may use an internal thermal cutout that will result in a open circuit if activated due to temperatures above the rated set point. This may be normal. Check system design. 2 Mechanical thermostat sensors cannot be repaired or replaced; RTD or thermocouple sensors may be replaced. Some controllers have replaceable contacts/relays, or may require a manual reset if a trip-off condition on the heating circuit was detected. 3 The operation of most electric heating circuits is dramatically affected by changes in the supply voltage. Before making any changes, consult the heater manufacturer with information on the alternate voltages available, otherwise, heater failure and/or electrical safety hazard may result is some situations. SYMPTOM IV.. Excessive Cycling POSSIBLE CAUSE REMEDY 4 Verify voltage prior to energizing heating system. Higher voltages can result in heater failure and/or an electrical safety hazard may result in some situations. 5 A liquid level below the heaters is considered an upset condition and should be avoided or prevented unless the heating system has been specifically designed for this condition. A. Temperature sensor located Relocate sensor. too close to heater or other heat source; may be accompanied by low system temperature. B. Connected voltage too high Lower voltage 4 (See item C) C. Heater output too high Install lower-output heater or lower voltage. D. Fluid level below heater Increase fluid level above heaters. 5 E. Wall thickness larger than Lower maintain temperature; design allowance Lower voltage; (Not an issure for steel wall) Design for lower watt density heater; Increase setpoint for high temp cut out. 7

FlexiPanel Vessel Heating System INSULATION JUNCTION BOX THERMOSTAT HEATER LOW LIQUID LEVEL ABOVE HEATERS POWER IN TEMPERATURE SENSOR SAMPLE INSTALLATION HORIZONTAL TANK INSULATION JUNCTION BOX THERMOSTAT POWER IN TEMPERATURE SENSOR SAMPLE INSTALLATION VERTICAL TANK HEATER LOW LIQUID LEVEL ABOVE HEATERS STANDARD DWG NO: 54A001 R2 Thermon Manufacturing Co. Printed in U.S.A. THERMON... The Heat Tracing Specialists 100 Thermon Dr. PO Box 609 San Marcos, TX 78667-0609 Phone: 512-396-5801 Facsimile: 512-396-3627 800-820-HEAT www.thermon.com In Canada call 800-563-8461

FlexiPanel Vessel Heating System Inspection Report Form For Electric Tank Heating Part 1 Page of LOCATION SYSTEM REFERENCE DRAWING(S) CIRCUIT INFORMATION BKR PANEL NO. BKR POLE(S) NO. HEATER JUNCTION BOX # # HEATERS PER JUNCTION BOX HEATER CONTROLLER HIGH LIMIT CONTROLLER (IF ANY) GROUND FAULT PROTECTION (TYPE) GROUND FAULT TRIP SETTING DATE COMMENTS AND ACTIONS

INSPECTION REPORT FORMS Inspection Report Form For Electric Tank Heating Part 2 Page of QUANTITY/TYPE/LOCATION/RESISTANCE HEATER MODEL PART NUMBER LOCATION RESISTANCE INSULATION RESISTANCE TESTING (BEFORE INSULATING) HEATER # TEST VOLTAGE MEGGER VALUE INSULATION RESISTANCE TESTING (AFTER INSULATING) HEATER # TEST VOLTAGE MEGGER VALUE HEATER SUPPLY VOLTAGE VALUE AT POWER SOURCE VALUE AT FIELD CONNECTION HEATER CIRCUIT CURRENT READING AMP READING GROUND FAULT CURRENT

FlexiPanel Vessel Heating System Inspection Report Form For Electric Tank Heating Part 3 Page of THERMAL INSULATION DAMAGED INSULATION OR LAGGING WEATHER SEAL GOOD INSULATION OR LAGGING MISSING PRESENCE OF MOISTURE CAUTION LABELS INSTALLED HEATING SYSTEM COMPONENTS ENCLOSURES, BOXES SEALED SIGN OF CORROSION HEATER WIRE CONNECTIONS PRESENCE OF MOISTURE HEATING AND/OR HIGH LIMIT CONTROLLER MODEL CONTROLLER SET POINT(S) OPERATING PROPERLY PERFORMED BY DATE APPROVED BY DATE COMPANY COMPANY

NOTES: INSPECTION REPORT FORMS