Pro-Clean Stratified Tank scope of delivery:

Similar documents
SUN EQUINOX HEATING SYSTEMS

Installation and operating instructions. DK energy storage and DK energy buffer

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

Buffer Tank FWSS 1000 V7-RH

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems

STORAGE WATER HEATERS

Installation manual Operating instructions

General System Layout Sketch

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Multilux 4-Eclipse-Set

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

TERMO Combi Cylinder TECHNICAL INFORMATION

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

Installation, Operating and Servicing Instructions

CIRCO 6 Solar Circulation Unit

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

Thermostatic valves with radiator connection systems

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

protective magnesium anode and hard polyurethane insulation. Socket for optional

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

CALORIFIERS (Energy Storage Tanks) for domestic, commercial and industrial applications.

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

OPERATING AND INSTALLATION MANUAL

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Industrial and collective. With coil exchanger. Technical data. Initial heat-up. surface area. Exchanger. Exchanger capacity.

PRODUCT INFORMATION. Solar DHW storage tank SKL. Technical description. High performance solar tank, bivalent

Congratulations with your purchase of our high quality, corrosion-free hot water cylinder (HWC).

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

Installation, operating and servicing instructions

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Problem-solvers The Radiator Solution Range

Condair Esco. Steam humidification system INSTALLATION INSTRUCTIONS EN 1310

Technical information SB 4 10/11 Prefabricated swimming pools -English-

Frequently Asked Questions Solar Collector G24

Mounting and Operating Instructions EB 2231 EN

SHOWERS SHOWERS

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

INDIRECT WATER HEATERS

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

REMKO Comfort-WP The versatile heat pump

Fresh Water Station FWS 20 / FWS 30. Manual. Masterpieces. Art.-Nr.: (V1.0) of Solar Technology

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Right-hand connection. 1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

OPERATING AND INSTALLATION MANUAL

General System Layout Sketch

Air Conditioner. user installation & manual manual. imagine the possibilities

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Solar heating systems

TA-MATIC

Three-way reversing valve

General System Layout Sketch

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

INSTALLATION GUIDE. soft duomatik evoline

HE120, HE160 Humidifier Installation Kit

product overview ProControl

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

MEGABAND MICA INSULATED BAND HEATERS

FAVORIT DISHWASHER USER MANUAL

sustainable energy solutions

Rif Cod i220-0

Installation & Operation Manual Models: TSU

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

Please read the following installation instructions first after purchasing this product or transporting it to another location.

REMKO HYBRID HEAT PUMPS

Installation Instructions for. CattleMaster Series Fountains

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Control valves for floor heating systems. Floor Heating Manifolds

Instruction Manual April sitrans AS 100

Installing the Turbo Floor Model System

Thermostatic valve bodies

D O M E S T I C Solar Thermal

Model BX-903, BX-904 and BX-906 Environmental Enclosure For BAM-1020 Operation Manual

Moisture inside the drum is due to final testing.

CryoPod Carrier. Quick Start Guide. English Quick Start Guide, 2 Français Guide de démarrage rapide, 8 Deutsch Schnellstartanleitung, 14

64 Beverage dispensing

SBB 300, 400 S & Sbb 300, 400, 600 Plus

INSTALLATION INSTRUCTION

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

Installation Instructions for. OmniFount

SOLAR TANKS for The rough

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Connection parts and accessories

FAVORIT VI DISHWASHER USER MANUAL

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

INDUSTRIAL / DOMESTIC WATER HEATERS

HT V2 HT Split

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

PRODUCTS THAT CONSERVE, REPAIR AND SAVE!

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

User Manual. Version 3.0

F-T, FT-P, F-L AND F-P SERIES

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

FAVORIT34502VIO. EN User Manual

Transcription:

Foreword Hearty congratulations on your purchase of a product from TiSUN! We vouch for the high quality and long service life of our products with our name. Only licensed specialized companies that have experience with our products are permitted to install and maintain them. Check The Pro Clean Stratified Tank and the accompanying modules must be checked for possible transport damage after unloading. Any damage must be indicated on the delivery slip. 22

Pro-Clean Stratified Tank scope of delivery: français english italiano deutsch 1 pc. Tank 3 pc. Melamine resin insulating shell 1 pc. Melamine resin insulating lid 1 pc. Melamine resin insulating base 1 pc. PVC end cover 4 pc. Melamine resin insulation disks (with perforation), español ½ cover rosettes, various insulating bungs and covers to insulate the unused connections 23

Technical Description Max. backup operating pressure 3 bar Max. service water operating pressure 6 bar Hot water connection 1 female thread* V4A (no. 1.4401) A insolation PRO - CLEAN Tank Cold water connection 1 female thread* V4A (no. 1.4401) Heating/boiler connection 6/4 female thread* with inflow absorber Thermometer and sensor connection 1/2 female thread* B Max. temperature 110 C Specifications Tilt height 1 Weight Type Total height Ø with Ø without Width A with Width B with with insulation 1 insulation 1 insulation 1 insulation 1 insulation 1 PC 500 1,860 mm 850 mm 650 mm 1,020 mm 1,175 mm 1,820 mm 178 kg PC 800 2,010 mm 950 mm 750 mm 1,105 mm 1,280 mm 1,975 mm 210 kg PC 1000-B 2,050 mm 1,050 mm 850 mm 1,180 mm 1,380 mm 2,020 mm 240 kg PC 1000-S 2,220 mm 990 mm 790 mm 1,140 mm 1,320 mm 2,185 mm 235 kg PC 1250 2,300 mm 1,100 mm 900 mm 1,235 mm 1,440 mm 2,270 mm 276 kg PC 1500 2,290 mm 1,200 mm 1,000 mm 1,320 mm 1,540 mm 2,280 mm 303 kg PC 2000 2,380 mm 1,300 mm 1,100 mm 1,400 mm 1,640 mm 2,380 mm 360 kg PC 2500 2,270 mm 1,500 mm 1,300 mm 1,600 mm 1,840 mm 2,350 mm 448 kg PC 3000 2,760 mm 1,450 mm 1,250 mm 1,530 mm 1,790 mm 2,780 mm 458 kg PC 4000 2,390 mm 1,800 mm 1,600 mm 1,830 mm 2,130 mm 2,520 mm 550 kg PC 5000 2,900 mm 1,800 mm 1,600 mm 1,830 mm 2,130 mm 3,020 mm 630 kg 1) All size specifications are in a tolerance range of +/- 3% 24

Hot water output and spherical exchanger sizing with the Pro-Clean stratified tank: Type PC 500 PC 800 PC PC 1000-B1000-S PC 1250 PC 1500 PC 2000 PC 2500 PC 3000 PC 4000 PC 5000 Tank volume lt. 520 760 980 980 1,250 1,490 1,930 2,430 2,910 3,920 4,950 Domestic water corrugated pipe volume lt. 45 55 55 55 55 60 65 75 75 75 75 One-off pouring capacity 1 lt. 400 600 810 810 1,050 1,290 1,710 2,150 2,610 3,560 4,475 deutsch english Tapping quantity (hot water) -T 2 at 30 lt/min C 4 3 3 3 3 3 3 3 3 3 3 -T 2 at 40 lt/min C 6 5 5 5 5 5 5 4 4 4 4 -T 2 at 50 lt/min C 10 8 8 8 8 7 7 6 6 6 6 -T 2 at 70 lt/min C 11 11 10 9 9 8 Area of use NF (hot water) 4 1-2 1-4 1-5 1-5 1-5 1-6 1-7 1-9 1-11 1-12 1-14 3 ST10-40 ST10-40 ST20-40 ST20-40 ST20-40 ST20-40 ST20-40 ST20-40 ST60 ST60 ST60 can be combined with ST60k ST60k ST60k ST60k ST60k ST60k 1... Pouring capacity (hot water up to 38 C) when the backup tank is charged at 60 C. 2... Temperature difference between the backup tank temperature and the domestic water tapping temperature when the tank is half-full. 3... The specifications are normal consumption values. Specific calculations are made for extreme consumption e.g. in swimming pools, saunas etc. 4... Number of flats (3 occupants/flat). Apply only without circulation. italiano français español 25

1. Installing the Pro-Clean tank: The Pro-Clean Stratified Tank must be installed by a certified company in a dry, frost-free space. Observe applicable laws, regulations and standards for boiler house piping and sanitary installations. Depending on its size, the Pro-Clean Stratified Tank can be carried into the space in which it will be installed upright or on its side or be brought in with lifting equipment. The only gripping points that may be used are the 6/4 sleeves (52 mm) or the two closed ¾ sleeved fittings on the lid and base. Follow the installation sequence step by step from a) to d). a) After it is brought in, lay the Pro-Clean Stratified Tank on its side, install the base insulation, stand it upright and place it in its intended location. Observe necessary clearances for installing the insulation and electrical heating element as well as any connections to other tanks. 26

b) When installing the electrical heating element, seal and screw in the 2 reducing sleeve (from the electrical heating element original accessories). c) The tank, including the spherical exchanger, can now be connected. A licensed specialist company is to make all necessary connections as indicated in the hydraulic connection plan provided by Tisun, depending on the purpose and additional components, and to start up the tank (see the Pro-Clean Spherical Exchanger installation instructions). Caution: Only connection materials made of noble metals (such as gunmetal, brass, or stainless steel) or plastics should be used for the domestic water connections (no. 2 and no. 13). Suitable immersion tubes (max. 100 mm) must be screwed into the ½ sleeves. The tank must then be checked for pressure and leakage. Observe the flow rule: According to the flow rule, nobler metals (such as copper) should not be used before less noble metals (such as steel) because they can dissolve the subsequent less-noble metal. This causes both corrosion in the piping system and increased contaminant loads in the drinking water. The flow rule applies not only to piping, but also to all used installation parts. español français italiano english deutsch 27

d) Install an expansion tank ( ET ) of sufficient size: Guideline: 10% of the total heating system water capacity. Calculating the admission pressure of the expansion tank: For example, building height 10 m = 1.0 bar Excess pressure = 0.5 bar Heating-side system pressure = 1.5 bar Admission pressure (membrane) = - 0.2 bar Admission pressure ET = 1.3 bar 28

2. Installing the Pro-Clean tank insulation: a) Tank insulation: Beginning with the two shells that connect to the spherical exchanger, click all three shells as tightly together as possible from top to bottom using the ratchet buckles. español deutsch français italiano english 29

b) Place the melamine resin lid and the PVC end cover on the tank. The ratchet buckles must be at the tightest position. c) All unused sleeves may be insulated using the round flexible foam plates. 30

d) Attach the ½ rosettes and the cover plates. español français english italiano deutsch e) If the spherical exchanger is not used, the melamine resin disks and the black cover caps are placed over the dummy flanges. 31

Pro-Clean Spherical Exchanger scope of delivery: 1 pc. Spherical exchanger 1 pc. Melamine resin insulating shell 1 pc. Melamine resin insulating lid with PVC cover 1 pc. Melamine resin insulating base (perforated) with PVC cover 8 pc. Flat seals 4 pc. Stratified charging flaps 16 pc. Washers ø 12 and nuts M12 2 pc. Aluminium rails with plate nuts and bolts 6 pc. Sealing band 32

3. Mounting the Pro-Clean Spherical Exchanger: a) The necessary fittings for the two connections on the spherical exchanger (ST1 and ST2) must be sealed, secured and brought into the proper position. deutsch english b) Attach 4 pieces of the included flat seals to the Pro-Clean Stratified Tank using installation sealing compound. Next, place the stratified charging discs into position in the order given (according to the drawing on the spherical exchanger) and once again install 4 flat seals using installation sealing compound. ST1 ST2 italiano français español 33

c) Secure the spherical exchanger from bottom to top using the washers and M12 nuts with a torque of 9 11 knm. d) If the spherical exchanger is used, the perforated inner portions of the insulating discs are removed, and the resulting rings are placed over the spherical exchanger connection pipes. e) Connect the solar lines to the indicated connections (red/blue) using a detachable connection. 34

4. Mounting the Pro-Clean Spherical Exchanger insulation a) After the Pro-Clean insulation is assembled, the labels may be removed and the included plate nuts may be placed in the pre-drilled holes. español deutsch français italiano english b) Screw on the aluminium rails. 35

c) Place the spherical exchanger melamine resin base around the collector inflow and return lines. d) Glue the included sealing bands onto the Pro-Clean tank s insulation as shown in the photo. One sealing band is glued onto the middle of the spherical exchanger. e) Attach the spherical exchanger insulation shell to the aluminium rail using screws. f) Place the insulating lid onto the top side of the spherical exchanger insulation, close it with the end cover, and fasten both the insulating lid and end cover with the dowels. 36

When retro-fitting a new spherical exchanger onto an existing Pro-Clean Stratified Tank: When working with PC tanks with rigid PU foam insulation and aluminium external casings, the spherical exchanger must be insulated onsite. With all other PC tanks, attach the spherical exchanger s insulation and mark the location of the aluminium sheet metal rails. To mount the aluminium rails with: a) PC tanks with PVC flexible foam external casing (since May 2001): Screw plasterboard anchors (e.g. type TOX GDK 32S) through the flexible foam casing into the PU insulation and mount the aluminium sheet metal rails. b) PC tank with melamine resin insulation and EPS external casing: Carefully use a drill (Ø 5 mm) to drill through the EPS external casing and likewise attach the rails with plasterboard anchors. deutsch english italiano español français 37

START-UP a) Fill the domestic water corrugated pipe to 2 bar b) Fill the tank with water and carry out a leakage test using a max. of 5 bar c) Bring the tank to heating-side system pressure (max. 3 bar) d) Using the FE valve, deaerate and refill the tank by the breather tube e) Fill the corrugated pipe with drinking water to the desired domestic pressure level (max. 6 bar) f) Once more, check all connections for leaks. 38

5. Safety notes In general, all legal regulations and applicable versions of the corresponding standards should be observed. Especially when used with solar energy systems or solid fuel boilers, we recommend that you install a thermostatic mixing valve in the hot water line to protect from scalds. Oxygen must be prevented from entering the heating side (risk of corrosion and sludge formation). Safety equipment, on both the sanitary and heating sides, must be provided onsite according to local and technical regulations (safety valve, manometer, etc.). To even out pressure variations in the service water system, TiSUN recommends the use of a suitable expansion tank. We recommend the use of a decalcification system for water hardness levels higher than 15 dh (German degrees of hardness) in order to prevent damage to devices in the entire household resulting from calcification. deutsch english italiano español français 39

2 30 3 15 1 1 4 6 7 8 9 31 5 16 17 spherical exchanger 1 1 10 11 13 32 33 18 11 19 40

1 Spherical exchanger with layer flaps 11 Sensor immersion tube for solar sensor 2 HW connection (stainless steel) 13 CW connection (stainless steel) deutsch 3 Breather tube 15 Sensor immersion tube for boiler thermometer 4 Forward flow: re-heating 5 Sensor immersion tube for boiler sensor 6 Forward flow: heating loop 7 Electric heating element 8 Return: re-heating 9 Return: high temperature heating loop 10 Return: low temperature heating loop 16 Sensor immersion tube usually for boiler sensor 17 Sensor immersion tube 18 Sensor immersion tube 19 Drain 30 Corrugated connection pipe 31 Corrugated connection pipe 32 Corrugated connection pipe 33 Corrugated connection pipe español français italiano english 41