G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.

Similar documents
E Specifications. Ver.1.2. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.

A Specifications. Ver.1.1. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

C 46 K a d. Specifications EKMC K. Ver.1.1. Page: EKMC K. 1.Product Name. 2.Model Number. 3.Dimensions. Approved by.

C Specifications. Ver.1.1. Page: EKMB Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2017 Jul.

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

PIR MOTION SENSOR. PIR Motion Sensor (EKMB, EKMC, AMN2, 3)

Simplified circuitry with fully integrated sensor design. Low curvature lens for product designs. Robust design prevents false detection

SP/WL/VZ SERIES. PaPIRs MOTION SENSOR

PIR MOTION SENSORS

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

Buzzer Unit. TAN-5000 Series. Operating Manual

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Applications PL- N Series Lens Type Sensor Type Serial Number

Ionizer (Static Remover) STABLO-EX Instruction Manual

APPROVED BY CHECKED BY DRAWN BY

Read this Safety Guide first.

ZMOTION Pyroelectric Sensors

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

Pyroelectric Infrared Sensors

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

PIR Motion Sensor. Special Designs from Panasonic that Provide High Sensitivity and Reliability

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Description. Optex Incorporated

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector

Pyroelectric Infrared Sensors

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

Pressure Switches Precautions 1 Be sure to read this before handling.

Metal, ceramic, plastic package products

E3M-V. Mark Sensor. Applications

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us:

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Advanced Ultraviolet Burner Controller

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

SPECIFICATION of PYROELECTRIC PASSIVE INFRARED SENSOR

Pyroelectric Infrared Radial Sensor

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

DAIKIN ROOM AIR CONDITIONER. Operation Manual

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

USE & CARE INSTRUCTIONS

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

250mm dia straight pipe length SP4 SP3. Air volume

RK/ RK Oxygen Detector Operator s Manual

Installation Guide. Home Network System Motion Sensor KX-HNS102HM. Model No.

AUR300C. Advanced Ultraviolet Burner Controller

ENGINEERING SAMPLES PYRO-ELECTRIC IR-DETECTOR

Smart Transmitter/ Gas Detector Head

Flame Simulator User Manual. Publication Rev. A

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

GENERAL INSTRUCTIONS FOR THE TM BI0MATMX

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Acusensor 3. Instruction Manual

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

CAUTIONS ON INSTALLATION

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

RK Combustible Gas Transmitter Operator s Manual

MightyMax Tower Fan MIGHTY POWERFUL. MIGHTY QUIET.

3 963/963E Benchtop Air Ionizer Instructions

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

CABINET INFRARED HEATER

Owner s Manual Super-Slim Four-Way Cassette

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C

Stand Fan. English. Owner s Guide. Model F R

Technical data sheet TDS0060

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Portable Refrigerator

RK-05 Carbon Monoxide Detector Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

Original instructions. Operation Manual & Cautions

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Furnace Gas Monitor SD Operating Manual (PT2-163)

RK-02 Multi Point Detector Operator s Manual

LUX Hardwired - Installation Notes

IRT2 Dual Laser IR Thermometer - User Guide

General safety precautions English

General safety precautions English

Technical data sheet TDS0034

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Transcription:

1. 2.Model Number VZ series Long distance detection type (170μA / Digital output / High Sensitivity) Lens Color White Black Pearl White Model Number EKMC4603111K EKMC4603112K EKMC4603113K Marking 1 3.Dimensions Top VIEW G045 G 0 45 a) b) c) a) The Marking which was shown by a list shown below Side VIEW Marking A B C D E F G H I Model Number EKMB110311 EKMB120311 EKMB260311 EKMC160311 EKMC260311 K EKMC460311 K b) Last-digit of the year (Ex:2010=0,2011=1, ) c) Lot No. 1 st week of Jan. will be 01, and further No. of 02,03, will continue up to 53. Bottom VIEW General Tolerance ±0.5mm (±0.020inch) Issued on Mar. Issued 26 th on,2018 Mar. 26 th,2018 Approved by Checked by Designed by

2 4.Characteristics 4-1 Detection Performance Conditions for measuring: Ambient temperature=25 (77 F) Operating voltage=5vdc (Note1) Detection Range Temperature difference Value Conditions concerning the target 4 (7.2 F) Max 17m 1.Movement speed: 1.0m/s 2.Target concept is human body 2 (3.6 F) Max 12m (Object size:around 700 250mm) Note1:Depending on the temperature difference between the target and the surroundings, detection range will change. Detection Area Value Horizontal 102 (±51 ) Vertical 92 (±46 ) Detection zones 92 Notes Refer to the section 4-5. 4-2 Maximum Rated Values Value Unit Power Supply Voltage -0.3~7.0 VDC Usable Ambient Temperature Storage Temperature -20~+55 (-4~+131 F) Do not use in a freezing or condensation environment -20~+70 (-4~+158 F) 4-3 Electrical Characteristics Conditions for Measuring: Ambient temperature=25 (77 F) Symbol Min Avg. Max Unit Special mention Operating Voltage Vdd 3.0-6.0 VDC - Electrical Current Consumption Iw - 170 300 μa Iout=0 Output Current Iout - - 100 μa Vout Vdd-0.5 Output Voltage Vout Vdd-0.5 - - VDC - Circuit Stability Time (when voltage is applied) Twu - - 30 s -

3 4-4 Timing Chart Power Supply ON OFF Detecting Target Present Absent Output Voltage ON OFF Twu Durations Twu:Circuit Stability Time=About 30s. (max.) During this stage, the output s status is undefined (ON/OFF) and detection is therefore not guaranteed.

4 4-5 Detection Area Vertical Tab Horizontal

5 4-6 Wiring Diagram Sensor Vdd + GND OUT Load + Iout:Max.100μA 4-7 Mounting Directions 1) Direction In this direction, no detection problem As detailed on the diagram, please install the sensor so that the expected trespassing direction corresponds to the axis X or axis Y. Y X Z In some cases, going back and forth towards the sensor (parallel movement to the axis Z), may not be detected. In this direction, detection is uncertain. 2) Detection Area Target As shown on the diagram, the detection zone is polarized. If a target enters the detection zones + and at the same time, the signals are respectively cancelled and detection could become impossible at maximum detection range. (Please refer to the detection area diagram in 4-5 for details) + - - +

6 5. Safety Precautions Head the following precautions to prevent injury or accidents. 1) Do not use these sensors under any circumstance in which the range of their ratings, environment conditions or other specifications are exceeded. Using the sensors in any way which causes their specifications to be exceeded may generate abnormally high levels of heat, emit smoke, etc., resulting in damage to the circuitry and possibly causing an accident. 2) Our company is committed to making products of the highest quality and reliability. Nevertheless, all electrical components are subject to natural deterioration, and durability of a product will depend on the operating environment and conditions of use. Continued use after such deterioration could lead to overheating, smoke or fire. Always use the product in conjunction with proper fire-prevention, safety and maintenance measures to avoid accidents, reduction in product life expectancy or break-down. 3) Before connecting, check the pin layout by referring to the connector wiring diagram, specifications diagram, etc., to verify that the connector is connected properly. Mistakes made in connection may cause unforeseen problems in operation, generate abnormally high levels of heat, emit smoke, etc., resulting in damage to the circuitry. 4) Do not use any motion sensor which has been disassembled or remodeled. 5) Failure modes of sensors include short-circuiting, open-circuiting and temperature rises. If this sensor is to be used in equipment where safety is a prime consideration, examine the possible effects of these failures on the equipment concerned, and ensure safety by providing protection circuits or protection devices. Example : Safety equipments and devices Traffic signals Burglar and disaster prevention

7 6.Operating Precautions 6-1 Basic Principles PaPIRs is a pyroelectric infrared sensor that detects variations in infrared rays. However, it may not detect in the following cases: lack of movement, no temperature change in the heat source. Besides, it could also detect the presence of heat sources other than a human body. Efficiency and reliability of the system may vary depending on actual operating conditions: And this model number is a high sensitivity item with a low threshold level. Please be aware that the false alarm probability will increase as compared with standard sensitivity items. 1) Detecting heat sources other than the human body, such as: a) small animals entering the detection area b) When a heat source for example sun light, incandescent lamp, car headlights etc, or strong light beam hit the sensor regardless inside or outside the detection area. c) Sudden temperature change inside or around the detection area caused by hot or cold wind from HVAC, or vapor from the humidifier, etc. 2) Difficulty in sensing the heat source a) Glass, acrylic or similar materials standing between the target and the sensor may not allow a correct transmission of infrared rays, b) Non-movement or quick movements of the heat source inside the detection area. 3) Expansion of the detection area In case of considerable difference in the ambient temperature and the human body temperature, detection area may be wider apart from the configured detection area. 4) Malfunction / Detection error Unnecessary detection signal might be outputted, on rare occasions, come from sudden outbreak output due to the nature of pyro-electric element. When the application does not accept such condition strictly, please implement the countermeasure by introducing pulse count circuit etc. 6-2 Optimal Operating Environment Conditions 1) Temperature : Please refer to the maximum rated values of 4-1. 2) Humidity Degree :15~85% Rh (Avoid condensation or freezing of this product) 3) Pressure : 86~106kPa 4) Overheating, oscillations, shocks can cause the sensor to malfunction. 5) This sensor is not waterproof or dustproof. Avoid use in environments subject to excessive moisture, condensation, frost, containing salt air or dust. 6) Avoid use in environments with corrosive gases.

8 6-3 Handling Cautions 1) Do not solder with a soldering iron above 350 (662 F), or for more than 3 seconds. This sensor should be hand soldered. 2) To maintain stability of the product, always mount on a printed circuit board. 3) Do not use liquids to wash the sensor. If washing fluid gets through the lens, it can reduce performance. 4) Do not use a sensor after it fell on the ground. 5) The sensor may be damaged by ±200 volts of static electricity. Avoid direct hand contact with the pins and be very careful when operating the product. 6) When wiring the product, always use shielded cables and minimize the wiring length to prevent noise disturbances. 7) The inner circuit board could be destroyed by a voltage surge. Use of surge absorption elements is highly recommended. Surge resistance : below the power supply voltage value indicated in the maximum rated values section. 8) Please use a stabilized power supply. Power supply noise can cause operating errors. Noise resistance : ±10V or less (Square waves with a width of 50ns or 1μs) To reduce the effect of power supply noise, install a capacitor on the sensor s power supply pin. 9) Operating errors can be caused by noise from static electricity, lightning, cell phone, amateur radio, broadcasting offices etc 10) Detection performance can be reduced by dirt on the lens, please be careful. 11) The lens is made of soft materials (Polyethylene). Please avoid adding weight or impacts that might change its shape, causing operating errors or reduced performance. 12) Operating temperatures and humidity level are suggested to prolong usage. However, they do not guarantee durability or environmental resistance. Generally, high temperatures or high humidity levels will accelerate the deterioration of electrical components. Please consider both the planned usage and environment to determine the expected reliability and length of life of the product. 13) Do not attempt to clean this product with any detergent or solvent, such as benzene or alcohol, as these can cause shape or color alterations. 14) Avoid storage in high, low temperature or liquid environments. As well, avoid storage in environments containing corrosive gas, dust, salty air etc. It could cause performance deterioration and the sensor s main part or the metallic connectors could be damaged. 15) Storage conditions Temperature: +5 ~ +40 (+41 ~ +104 F) Humidity: 30 ~ 75% Please use within 1 year after products delivery.

9 7.When Designing Your Product To maintain specified detection capability, please place and expose the sensor so that tip of lens will be more than 7.1mm above the chassis. The hole of the chassis should have a taper depending on the lens shape, or have a bigger hole. Recommended Hole Drilling Diameter Chassis s Hole-drilled Part Recommended PCB Pattern Diagram

10 8.Special Notice As improvements are continually being made, the specifications or design of this product are subject to change without notice. Please strictly follow the Safety Precautions and Operating Precautions on the specifications sheet. Normal functioning cannot be expected if used in environments or conditions other than those specified above. We are deeply committed to providing the highest quality control for this product. Nevertheless: 1) For issues not addressed above, we invite you to share your suggestions, or details about your company s usage conditions, installation, specifications, needs of end users, and applications for this sensor. 2) To reduce the risk of harm caused by product failure to human life or assets, this product should always be used in conjunction with other safety measures, such as protective circuitry, double layered circuit boards, etc., and used within the guaranteed performance, efficiency or special characteristics values stated in the specification sheet. 3) This product is warranted for a period of one year, from date of delivery, applicable only if the product is used in accordance with the precautions mentioned above and the specifications sheet. We will replace or repair at the delivery location any malfunctioning or defective part or entire product if such defect or malfunction is caused by us. However, the above warranty shall be void in the following circumstances: a) Damage caused to something else than the product itself. b) Damage or loss resulting during transportation, storage or handling after the date of supply. c) Phenomenon unforeseeable in the state of the technology as of the supply date. d) Damage caused by natural or unnatural events such as fire, earthquake, flood, or conflicts beyond our control.