OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

Similar documents
OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

OPERATION MANUAL. Split system air conditioners FHYBP71B8V1 FHYBP100B8V1 FHYBP125B8V1 FHYCP71B8V1 FHYCP100B8V1 FHYCP125B8V1

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

OPERATION MANUAL. Split system air conditioners FCQG35FVEB FCQG50FVEB FCQG60FVEB FCQG71FVEB FCQG100FVEB FCQG125FVEB FCQG140FVEB

DAIKIN ROOM AIR CONDITIONER. Operation Manual

OPERATION MANUAL. Split system air conditioners FDYP125B8V1 FDYP200B8V1 FDYP250B8V1 FDQ125B8V3B FDQ200B8V3B FDQ250B8V3B

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

OPERATION MANUAL. VRV Classic System air conditioner RXYCQ8A7Y1B RXYCQ10A7Y1B RXYCQ12A7Y1B RXYCQ14A7Y1B RXYCQ16A7Y1B RXYCQ18A7Y1B RXYCQ20A7Y1B

SPLIT SYSTEM Air Conditioners

KSD-35 DR11 KUE-35 DVN11

Operation manual. Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner s Manual Super-Slim Four-Way Cassette

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

SYSTEM Inverter Air Conditioners

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Bosch Split-Type Ductless Air Conditioner / Heat Pump

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

SYSTEM Inverter Air Conditioners

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

NEXXOS INVERTER USER MANUAL

OPERATION MANUAL. System air conditioner

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

SLIM CASSETTE TYPE AIR CONDITIONER OWNER S MANUAL

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

OPERATION MANUAL. MODELS (Duct Connection type) English. Chinese. Arabic

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

Owner s Manual CS

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATION MANUAL. MODELS (Ceiling-mounted Multi flow Cassette type) FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B

Wireless Remote Controller Kit

This air conditioner comprises an indoor unit, outdoor unit, and a connection pipe.

OPERATION MANUAL. MODELS Ceiling mounted cassette type (Round flow model)

CDKD25CVM CDKD35CVM Operation Manual

OPERATION MANUAL. MODELS Ceiling mounted cassette type (Round flow model) FCQN140KVEA FCQN125KVEA

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

OPERATION MANUAL. Wireless Remote Controller Kit

Inverter Split-type Room Air Conditioner

SYSTEM Inverter Air Conditioners

DAIKIN ROOM AIR CONDITIONER MODELS CDXS25EAVMA CDKS25EAVMA CDXS35EAVMA CDKS35EAVMA. Operation Manual

SPLIT SYSTEM Air Conditioners

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

English DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL. Français. Español MODELS FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU

Middle Static Pressure Duct Type

SPLIT SYSTEM Air Conditioners

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

INDOOR UNIT/OUTDOOR UNIT

Indoor Unit :FPA-18 FPA-24 FPA-36DU FPA-48DU Outdoor Unit :CPP018CD(O) CPP024CD(O) CPP036CD(O)-DU CPP048CD(O)-DU

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

SPLIT TYPE. Instruction manual

ZEAS-AC OPERATION MANUAL

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATION MANUAL. MODELS (Ceiling-mounted Duct type) FBQ50EVE4 FBQ60EVE4 FBQ71EVE4 FBQ100EVE4 FBQ125EVE4 FBQ140EVE4. English.

53 KNL / 53 QNL OWNER S MANUAL

Middle Static Pressure Duct Type

INDOOR UNIT/OUTDOOR UNIT

DAIKIN ROOM AIR CONDITIONER. Operation Manual ATXD60CV4 ATXD71CV4 ATXD80CV4

DAIKIN ROOM AIR CONDITIONER. Operation Manual

Operation Manual MODELS FTYN25DV3B FTN25DV3B FTYN35DV3B FTN35DV3B FTYN25DAV3B FTN25DAV3B FTYN35DAV3B FTN35DAV3B DAIKIN ROOM AIR CONDITIONER.

CONTENTS READ BEFORE OPERATION

MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B DAIKIN ROOM AIR CONDITIONER. Operation Manual

X-POWER Full DC Inverter Outdoor Unit

OPERATION MANUAL FAQ18PVJU FAQ24PVJU. MODELS (Wall mounted type)

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

OWNER S MANUAL VMH 09/12/18/24

Using the Remote Control Unit

INDOOR UNIT/OUTDOOR UNIT

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.


Wireless Remote Controller Kit

DAIKIN ROOM AIR CONDITIONER FTXS50FVMA FTKS50FVMA FTXS60FVMA FTKS60FVMA FTXS71FVMA FTKS71FVMA FTXS80FVMA FTXS90FVMA MODELS.

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FVXS25KV1A FVXS35KV1A FVXS50KV1A FVXS35LV1A

SU MO TU WE TH FR SA AM PM

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference.

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

DAIKIN ROOM AIR CONDITIONER. Operation Manual MODELS FTXS25EVMA FTKS25EVMA FTXS35EVMA FTKS35EVMA

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL. Enjoy year-round comfort. MODELS FVXS25KV1A FVXS35KV1A FVXS50KV1A FVXS25RV1A FVXS35RV1A FVXS45RV1A

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

OWNER S MANUAL COMPLETE VRF OUTDOOR UNIT

OPERATION MANUAL CONVENI-PACK LRYEQ16A7Y1 LCBKQ3AV1(E)

TVR 5G All DC Inverter Heat Recovery

Wall Mounted Mini Split Heat Pump Air Conditioner

INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

INDOOR UNIT/OUTDOOR UNIT

SPLIT - TYPE ROOM AIR CONDITIONER

Owner s Manual TABLE OF CONTENTS

Reverse Cycle Split System Air Conditioner

SPLIT-TYPE ROOM AIR CONDITIONER

Transcription:

OPERATION MANUAL system room air conditioners

1 1 5 6 9 4 7 Pair Paar Paire Pair Par Singolo  ÁÔ Par Сплит 3 2 4 5 ÔÏÏ appleïfi Много 8 1 2a 2b 3a 3b 2a 2b 3a 3b S

system room air conditioners CONTENTS Page What to do before operation... 1 Operation range... 1 Installation site... 1 Operation procedure... 2 Optimum operation... 2 Following symptoms are not air conditioner troubles... 2 Troubleshooting... 3 Maintenance... 3 WHAT TO DO BEFORE OPERATION This operation manual is for the following systems with standard control. Before initiating operation, contact your dealer for the operation that corresponds to your system. Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file it away for future reference. These units can be controlled by a remote controller. Refer to the manual of the remote controller for more information. If your installation has a customized control system, ask your Daikin dealer for the operation that corresponds to your system. Never let the indoor unit and the remote controller get wet. It may cause an electric shock or a fire. Never use flammable spray such as hair spray, lacquer or paint near the unit. It may cause a fire. Never replace a fuse with that of a wrong ampere rating or other wires when the fuse blows out. Use of wire or copper wire may cause the unit to break down or cause a fire. Never touch the air outlet or the horizontal blades while the swing flap is in operation. Fingers may become caught or the unit may break down. Never insert objects such as sticks into the air inlet or outlet. It is dangerous for an object to touch the fan when it is turning at high speed. Never remove the fan guard of the outdoor unit. The rotating fan at high speed without the guard is very dangerous. Never inspect or service the unit by yourself. Ask a qualified service person to perform this work. OPERATION RANGE If temperature or humidity is beyond the following conditions, safety devices may work and the air conditioner may not operate, or sometimes, water may drop from the indoor unit. COOLING HEATING outdoor temperature 10~46 CDB 15~20 CWB indoor temperature 14~28 CWB 10~30 CDB indoor humidity 80% (*) (*) to avoid condensation and water dripping out the unit Pair system combination Contact your dealer to know the correct operation range. It can change depending on the outdoor unit connected. This heat pump system provides cooling, heating and automatic operation mode. Names and functions of parts (See figure 1) 1 Indoor unit 2 Outdoor unit 3 Remote controller (optional) 4 Inlet air 5 Discharged air 6 Refrigerant piping, connection electric wire 7 Drain pipe 8 Ground wire 9 Suction air filter (optional) INSTALLATION SITE Never place anything under the indoor unit that you do not want to get wet. The unit may sweat when the humidity is over 80% or when the drain outlet is clogged. Never place other heating equipment directly beneath the indoor unit. Subject to deformation caused by heat. Do not place TV, radio, stereo, etc. within 1 meter from the indoor unit and remote controller. Doing so may cause interference in the picture or sound. system room air conditioners 4PW15396-1A 1

OPERATION PROCEDURE Explanation of heating operation Master-slave unit system (mode batting) System operation mode cool or heat is determined by the mode the master unit is in. When the master unit is in cool mode, respectively heat mode, the system can only operate in cooling, respectively heating, regardless of the thermostat setting. When the master unit is OFF, the system mode is determined by the unit which is switched on first. OPTIMUM OPERATION Observe the following precautions to ensure the system operates properly. Adjust the air outlet properly and avoid direct air flow to room inhabitants. Adjust the room temperature properly for a comfortable environment. Avoid excessive heating or cooling. Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds. Keep doors and windows closed. If the doors and windows remain open, air will flow out of your room causing a decrease in the cooling or heating effect. Never place objects near the air inlet or the air outlet of the unit. It may cause deterioration in the effect or stop in the operation. Turn off the main power supply switch to the unit when the unit is not used for longer periods of time. If the switch is on, it uses electricity. Before restarting the unit, turn on the main power supply switch 6 hours before operation for smooth running. (Refer to "Maintenance" on page 3) When the display shows " " (time to clean the air filter), ask a qualified service person to clean the filters. (Refer to "Maintenance" on page 3) FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES The system does not operate The system does not restart immediately after the ON/OFF button is pressed. If the OPERATION lamp lights, the system is in its normal operating condition. It does not restart immediately because one of its safety devices actuates to prevent the system from being overloaded. The system will turn on again automatically after three minutes. The system does not restart immediately when the TEMPERATURE SETTING button is returned to the former position after pushing. It does not restart immediately because one of its safety devices actuates to prevent the system from being overloaded. The system will turn on again automatically after three minutes. 2 If a function that is not available is selected, the message NOT AVAILABLE will appear. To protect the unit, turn on the main power switch 6 hours before operation. If the main power supply is turned off during operation, operation will restart automatically after the power turns back on again. The master-slave setting is decided upon and set during installation. The system does not start when the display shows " " (EXTERNAL CONTROL ICON) and it flashes for a few seconds after pressing an operation button. This is because the system is controlled or disabled by another controller with a higher priority. When the display flashes, it indicates that the system cannot be controlled by this indoor unit. The system does not start when the display shows " ". This indicates that the change-over of the installation is under centralized control asigned to another unit or to an optional cool/ heat selector connected to the outdoor unit (= master remote controller). The indoor unit has to be restarted with the controller. The system does not start immediately after the power supply is turned on. Wait one minute until the micro computer is prepared for operation. White mist comes out of a unit When humidity is high during cooling operation (in oily or dusty places) If the inside of an indoor unit is extremely contaminated, the temperature distribution inside a room becomes uneven. It is necessary to clean the inside of the indoor unit. Ask your Daikin dealer for details on cleaning the unit. This operation requires a qualified service person. When the system is changed over to HEATING OPERATION after DEFROST OPERATION. Moisture generated by DEFROST becomes steam and exits. Noise of air conditioners A continuous low "hissing" sound is heard when the system is in COOLING or DEFROST OPERATION. This is the sound of refrigerant gas flowing through both indoor and outdoor units. A "hissing" sound which is heard at the start or immediately after the stop of operation or which is heard at the start or immediately after the stop of DEFROST OPERATION. This is the noise of refrigerant caused by flow stop and flow change. A continuous low "swishing" sound is heard when the system is in COOLING OPERATION or at a stop. The noise is heard when the drain pump is in operation. A "squeaking" sound is heard when the system is in operation or after the stop of operation. Expansion and contraction of plastic parts caused by temperature change makes this noise. Dust from the units Dust may blow out from the unit after starting operation from long resting time. Dust absorbed by the unit blows out. The units give off odors The unit absorbs the smell of rooms, furniture, cigarettes, etc., and then emits them. The liquid crystal of the remote controller shows " " Happens immediately after the main power supply switch is turned on. Shows that the remote controller is in normal condition. Continues temporary. system room air conditioners 4PW15396-1A

TROUBLESHOOTING If one of the following malfunctions occurs, take the measures shown below and contact your Daikin dealer. The system must be repaired by a qualified service person. If a safety device such as a fuse, a breaker or an earth leakage breaker frequently actuates, or the ON/OFF switch does not properly work; Measure: Turn off the main power switch If water leaks from unit; Measure: Stop the operation. If the display " " (INSPECTION), "UNIT No.", and the OPERATION lamp flashes and the "MALFUNCTION CODE" appears. Measure: Notify your Daikin dealer and inform him/her of the display. If the system does not properly operate except for the above mentioned case, and none of the above mentioned malfunctions is evident, investigate the system according to the following procedures. If the system does not operate at all. - Check if there is a power failure. Wait until power is restored. If power failure occurs during operation, the system automatically restarts immediately after the power supply recovers. - Check if the fuse has blown or breaker has been stripped. Change the fuse or set the breaker. If the system stops operating after operation is complete. - Check if the air inlet or outlet of outdoor or indoor unit is blocked by obstacles. Remove the obstacle and make it well-ventilated. - Check if the air filter is clogged. Ask a qualified service person to clean the air filter. The system operates but it does not sufficiently cool or heat. - If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles. Remove the obstacle and make it well-ventilated. - If the air filter is clogged. Ask a qualified service person to clean the air filter. - If the set temperature is not proper. (Refer to the manual of the remote controller) - If the FAN SPEED CONTROL button is set to LOW SPEED. (Refer to the manual of the remote controller) - If the air flow angle is not proper. (Refer to the manual of the remote controller) - If the doors or the windows are open. Shut doors or windows to prevent wind from coming in. - If direct sunlight enters the room (when cooling). Use curtains or blinds. - When there are too many inhabitants in the room. Cooling effect decreases if heat gain of the room is too large. - If the heat source of the room is excessive (when cooling). Cooling effect decreases if heat gain of the room is too large. MAINTENANCE Only a qualified service person is allowed to perform maintenance. Before obtaining access to terminal devices, all power supply circuits must be interrupted. Do not use water or air of 50 C or higher for cleaning air filters and outside panels. When cleaning the heat exchanger, be sure to remove the switchbox, fan motor and drain pump. Water or detergent may deteriorate the insulation of electronic components and result in burn-out of these components. How to clean the air filter Clean the air filter when the display shows " " (TIME TO CLEAN AIR FILTER). Increase the frequency of cleaning if the unit is installed in a room where the air is extremely contaminated. (As a yardstick for yourself, consider cleaning the filter once a half year.) If the dirt becomes impossible to clean, change the air filter. (Air filter for exchange is optional.) Do not operate the air conditioner without filters, this to avoid dust accummulation inside the unit. 1 Removing the air filter Rear suction (See figure 2a): Pull the bottom side of the air filter backwards, over the 2 bends. Bottom suction (See figure 3a): Pull the filter over the two bends situated at the backside of the unit. 2 Cleaning the air filter Remove dust from the air filter using a vacuum cleaner and gently rinse them in cool water. Do not use detergent or hot water to avoid filter shrinking or deformation. After cleaning dry them in the shade. 3 Replacing the air filter Rear suction (See figure 2b): Hook the filter behind the flap situated at the top of the unit and push the other side gently over the 2 bends. Bottom suction (See figure 3b): Hook the filter behind the flap situated at the middle of the unit and push the other side gently over the 2 bends. Before a long stop period Operate the fan only for several hours to dry the inside of the indoor unit. Set the remote controller in fan only operation mode. Set the remote controller in cool operation mode and the temperature setting at 31 C. Disconnect the power supply by turning off the safety breaker (fuse or earth leak detector). Clean the air filters and set them back in place. Start-up after a long stop Confirm the following: - Check that the air inlet and outlet are not blocked. Remove any obstacle. - Check if the earth is connected. Clean the air filter and outside panels. - After cleaning the air filter, make sure to attach it. Turn on the main power supply switch. - The control panel display lights when the power is turned on. - To protect the unit, turn on the main power switch at least 6 hours before operation. Disposal requirements Dismantling of the unit, treatment of the refrigerant, oil and eventual other parts, should be done in accordance with the relevant local and national regulations. system room air conditioners 4PW15396-1A 3

Zandvoordestraat 300, B-8400 Oostende, Belgium 4PWEN15396-1A