Multifit. Installation & Commissioning Instructions

Similar documents
Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

Combi Eco Elite Range. User s Guide and Important Warranty Information

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

User Guide. Promax SL Condensing Central Heating Boiler

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Installation & User s Instructions

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

User Guide. Gold Combi Condensing Combination Boiler

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Baxi Maxflow Combi FS

Baxi Maxflow Combi WM

Performa System 12e, 18e, 24e & 28e

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Baxi Bermuda Inset 3 Super

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Installation & Servicing Instructions

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

User Guide. Assure Heat Condensing Central Heating Boiler

User Guide. Promax Store 24. Condensing Boiler with Integrated Hot Water Storage

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater

SAP Product Characteristics Database (PCDB) - Application Guide for Compensating Boiler Controls and Time and Temperature Zone Controls (TTZC)

User Guide Combi. Condensing Combination Boiler

Wall hung combination boiler PROTHERM 23 BTVE

Osprey 2 CFL

User Guide. EcoBlue System Gas Fired Wall Mounted Condensing System Boiler

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Logic+ Combi

Unvented Electric Water Heater 10/15 litre Undersink

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

USERS GUIDE. LOGIC+ Combi 24, 30, 35

MAINTENANCE AND SERVICE GUIDE

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

Bosch Group. 15SBi / 24SBi. WALL MOUNTED BOILERS FOR CENTRAL HEATING and Indirect supply of domestic hot water

Osprey 2 CFL

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

Bosch Group. 15SBi / 24SBi. WALL MOUNTED BOILERS FOR CENTRAL HEATING and Indirect supply of domestic hot water

Baxi Combi 80 Maxflue

DOMESTIC HOT WATER Follow operational sequence

Installation and Service Manual. Promax System Condensing System Boiler

Sirius FS. Working towards a cleaner future

Installation and Servicing Instructions. Alpha FlowSmart

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Installation and Service Manual. Heat Condensing Central Heating Boiler

Megaflo 2 System Compact GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing System Boiler

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

SLIM-LINE RC. Installation, Operating, Maintenance and After Sales Manual. Please leave this manual with the end user. Part Number: Issue 3

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

Modulating clock thermostat

WEATHER COMPENSATION KIT

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

CREDA STORAGE RADIATORS

Installation Instructions

Alpha CombiMax 350 and 600

Wall hung combination boilers. This is a CAT II2H3+ appliance USER, INSTALLATION AND SERVICING INSTRUCTIONS SUPPORTED BY

SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK

User s Operation Instructions & Important Warranty Information

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Service manual. Riva Plus HE. M296.28SR/C System boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler

Installation & Service Instructions. Gold FSB 30 HE. Floor Standing Condensing Boiler. You can rely on

Mikrofill Ethos Condensing combination boiler

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

SIGMA. Wall Mounted Cast Iron, Gas Fired Boiler for Central Heating Fan Assisted, Room Sealed, Electronic Flame Ignition and Control

Installation and Service Manual. Mega o System Gas Fired Wall Mounted Condensing System Boiler

Vokèra OpenTherm 711 with external sensor connected

Baxi Genesis Gas Fired Wall Mounted Combination Boiler Natural Gas, Propane & Butane Comp N o /96

ferroli Boiler Replacement Maxima 35C- Modena HE

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Installation and Service Manual. Promax SL Condensing Central Heating Boiler

BOSCH CONDENS 5000W ZSB18-2A

Installation & Servicing Manual. for the Ultra range of wall mounted fan assisted balanced flue gas boilers

400GL PX (PF) Servicing Instructions. For use in GB and IE PLEASE READ THESE INSTRUCTIONS BEFORE SERVICING THIS APPLIANCE

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

Gas condensing boiler

Installation and Maintenance

Battery Powered Electronic Room Thermostat Cat. No. TRT033

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

Sirius WH. Working towards a cleaner future

Installation and Service Manual. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Solo 3 PFL System

Installation and Service Manual. Titanium Combi Condensing Combination Boiler

USERS GUIDE 24, 30. For installation guide see reverse of book

MIX Boiler & Font Range Service Manual

AGA TOTAL CONTROL. Model No s: TC3 & TC5 (ROOM VENT OPTION)

Transcription:

United Kingdom en Multifit Part No. 7683084 Installation & Commissioning Instructions IFOS - In Flue Outdoor Sensor Kit Temperature Compensation Device Suitable for Combination boilers fitted in conjunction with horizontal flue terminals ONLY & flue systems up to 4 metres These instructions should be read in conjunction with the Boiler Installation and Service Manual and left with the User when completed. Please keep these instructions in a safe place. If you move house please hand them over to the next occupier.

The In Flue Outdoor Sensor is suitable for use with the following boilers:- BOILER GROUP A Baxi Duo-tec Combi range Regulation EU811/2013, supplementing Ecodesign and Energy Labelling Directives 20/30EU Part Number Baxi Platinum Combi range Main Eco Elite Combi range Potterton Promax Combi range Potterton Gold Combi range Potterton Titanium Combi range BOILER GROUP B Baxi 0 Combi range Potterton Promax Ultra Combi range BOILER GROUP C Baxi EcoBlue + Combi & Advance Combi ranges BOILER GROUP D Baxi 200 Combi range Baxi 400 Combi range BOILER GROUP E Baxi 600 Combi range Potterton Assure Combi range Refer to the Installation & Service Manual supplied with the appliance if the boiler being installed is not on the above list. ErP Information This Thermostatic Control Device is rated Correction Factor (Contribution to system energy efficiency) 7683084 Class II 2 % Contents Section Page 1.0 Legislation 2 2.0 Introduction 3 3.0 Contents of pack 3 4.0 Fitting the in flue outdoor sensor 4 5.0 Connecting the in flue outdoor sensor boiler group A 5 6.0 Setting the in flue outdoor sensor curve boiler group A 6 7.0 Connecting the in flue outdoor sensor & setting the curve boiler group B 7 8.0 Connecting the in flue outdoor sensor boiler group C 8 9.0 Setting the in flue outdoor sensor parameters boiler group C 8.0 Operating instructions in flue outdoor sensor boiler group C 9 11.0 Fault finding boiler group C 12.0 Connecting the in flue outdoor sensor & setting the slope boiler group D 11 13.0 Connecting the in flue outdoor sensor & setting the curve boiler group E 12 14.0 Notes 13 15.0 User Information 15 1.0 Legislation NOTES: This kit is suitable only for installation in GB and IE and should be installed in accordance with the rules in force. In GB, the installation must be carried out by a Gas Safe Registered Installer. It must be carried out in accordance with the relevant requirements of the: Gas Safety (Installation & Use) Regulations. The appropriate Building Regulations either:- The Building Regulations,The Building Regulations (Scotland), Building Regulations (Northern Ireland). The Water Fittings Regulations or Water Byelaws in Scotland. The Current I.E.E.Wiring Regulations. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice. In IE, the installation must be carried out by a competent Person and installed in accordance with the current edition of I.S. 813 'Domestic Gas Installations', the current Building Regulations and reference should be made to the current ETCI rules for electrical installation. 2 7687799-01 (2/18)

(i) (ii) For boilers in Group A ONLY 2.0 Introduction 1. The In Flue Outdoor Sensor - IFOS - kit positions a temperature sensor in the horizontal flue terminal. The flue system can be up to 4 metres of actual length. Installation of this kit permits the customer to gain the efficiency benefits of outdoor weather temperature compensation control. The sensor allows the outdoor temperature to be taken into consideration and the boiler flow temperature regulated accordingly to provide required comfort levels. 2. The curve determining boiler flow temperature should be set as low as possible but still maintaining required comfort levels. The selected curve must be noted on the identifying label to be affixed to the boiler. 3. The addition of anything that may interfere with the normal operation of the appliance without express written permission from the manufacturer could invalidate this kit and the appliance warranty. In GB this could also infringe the Gas Safety (Installation and use) Regulations. 4. This kit is only suitable for use with the boiler ranges listed by group on page 2. (iii) For boilers in Group A ONLY IMPORTANT: This kit is for use ONLY with horizontal flue terminals in a flue system of up to 4 metres actual length. It cannot be fitted where other devices such as the MULTIFIT GasSaver are incorporated into the flue system. It is permissible to shorten the cable but it must not be extended or any connectors fitted in its length. If shortening the cable DO NOT cut the sensor end! (iv) IFOS ErP Class II x 2 I certify that this boiler is connected to a weather compensation temperature sensor which is compatible with the boiler & provides weather compensation control that has been permanently enabled. The boiler has been commissioned in accordance with Manufacturer instructions which have been supplied to the Householder. The Central Heating control should be set so that a value of is displayed or in the position. Signed: Date: (vi) Baxi, Brooks House, Coventry Road, Warwick, CV34 4LL Baxi Customer Support 0344 871 1545 7687801-01 (2/18) (v) Conventional Controls: Standard mains voltage ON/OFF controls do not affect the method of setting the curve or boiler operation when the IFOS is fitted. Conventional controls in conjunction with IFOS represent the simplest solution. OpenTherm Controls: If an OpenTherm control is also to be connected to the boiler this must be taken into consideration as some devices affect the operation of the boiler control knobs or buttons. Depending on the device used it is possible that the OpenTherm control will assume the role of master, rendering the boiler controls inoperative or altering their function. It is recommended that the IFOS is fitted and set prior to connecting any OpenTherm device. Consult the instructions supplied with such devices before setting the curve. The Baxi usense device is recommended for this type of control application. 3.0 Contents of Pack Description (i) In Flue Outdoor Sensor (IFOS) & Clip Assembly (ii) M2 Terminal Strip & Screw (for boilers in Group A only) (iii) Replacement Harness (for boilers in Group A only) (iv) 2 x Self Adhesive Routing Clips (v) Cleaning Wipe Sachet 7687799-01 (2/18) (vi) Identifying Label 3

Clip blade must point out of terminal IFOS in position on underside of flue terminal 4.0 Fitting the In Flue Outdoor Sensor (IFOS) - All Models 1. The IFOS must be fixed in the air inlet of the boiler horizontal flue terminal at the time of installation. It MUST be positioned as shown (Fig. 1) or to the adjacent vane. Fix IFOS Clip to either of these vanes 2mm ± 1mm Fig. 1 NOTE: To ensure effective operation the end of the IFOS must be positioned to protrude 2mm ± 1mm from the body of the clip (Fig. 2). 2. The IFOS comprises of 5 metres of small diameter flexible cable. At one end there is a temperature sensor and mounting clip, which is positioned in the flue terminal air inlet. The other end has two wires to be connected to the boiler low voltage terminal. 3. Commence the boiler installation as described in the Installation & Service manual to the point where the flue is cut or adjusted and set to length. Do not cut the flue once the IFOS cable is inserted. Ensure that all electrical supplies are isolated & check to confirm. Fig. 2 4. Insert the loose end of the IFOS cable into air inlet of the cut or adjusted flue terminal. Fix the clip to one of the vanes on the air inlet as shown (Fig. 1). Ensure that it is firmly in position. 5. Pull the loose end of the IFOS cable out of the flue air duct. Terminal IFOS cable Boiler Elbow Schematic showing IFOS cable route 6. Pass the loose end of the IFOS cable through the air duct of the flue elbow and into the outer part of the boiler adaptor (Fig. 3). 7. Ensure that the IFOS cable is accessible within the boiler and continue to assemble and complete the flue installation. 8. Using the wipe provided clean an area on the inner face of the top panel. Fix one of the self adhesive routing clips to the panel (Fig. 4). Connector Fig. 3 9. Route the IFOS cable through the boiler ensuring that it does not touch any hot surfaces or is adjacent to moving parts, e.g. fan. The second routing clip will assist this. Fix Routing Clip to inner face of top panel - typical example shown. Depending on boiler model it may be desirable to route the cable to the left. Fig. 4 NOTE: Depending upon boiler type and position of the connection terminals the cable can be run to either the left or right.. If required cut the IFOS cable to length, leaving sufficient slack to allow the facia panel to be hinged down. If shortening the cable DO NOT cut the sensor end! For more information scan the code:- 4 7687799-01 (2/18)

3 way grommet Fig. 5 5.0 Connecting the Sensor - boiler Group A 1. Ensure that the electrical supply to the boiler is isolated. Allow the facia to drop down (Fig. 6). Route the IFOS cable through the 3 way grommet (Fig. 5) in the combustion box lower panel. 2. Undo the screws securing the cover and release the cover retaining barbs from their slots. Disengage the rear of the cover from the facia hinge pin and lift the cover away (Fig. 7). Fig. 6 3. Do not touch the PCB unnecessarily, and take care when removing and fitting connectors. The use of an earthing wristband is recommended. M2 low voltage terminal strip 4. Engage the M2 low voltage 8 way terminal strip over the vertical flanges and secure with the screw supplied (Fig. 8). Fig. 8 5. Disconnect the harness connector from position X400 on the PCB (Fig. 9). X400 br br Fig. 7 6. Disconnect the wiring from the Hall Effect Sensor, DHW NTC and Water Pressure Switch (Figs. & 11). Retain the Hall Effect Sensor. 7. Connect the new harness supplied to position X400 on the PCB. Fig. 9 8. Connect the harness terminals to the Hall Effect Sensor, DHW NTC and Water Pressure Switch (see Figs. 9 & ). Refit the Hall Effect Sensor. Combi Hall Effect Sensor Combi Water Pressure Switch & DHW NTC 9. Connect the two brown wires on the new harness to 4 & 5 on the M2 low voltage 8 way terminal strip (Fig. 12).. Connect the IFOS cable to 4 & 5 on the M2 low voltage 8 way terminal strip (Fig. 12). There is no polarity. Fig. Brown Wires from New Harness (X400) br 1 3 2 br 5 4 6 8 7 Fig. 11 Note the boiler setting on the identifying label supplied. It must then be signed and affixed to the front of the boiler or inside the control cover facia. The label must be readily accessible without removing the boiler casing or any other disassembly. This label is required to enable SAP/energy assessors to identify that a weather compensation device is installed. 11. Refit the cover, resecure the facia and door panel. Fig. 12 IFOS Cable For more information scan the code:- 7687799-01 (2/18) 5

6.0 Setting the Sensor Curve - boiler Group A Curve 5 Curve Reset Fig. 13 NOTE: Depending upon model of boiler different types of Selector Switch and Central Heating Control Knob will be fitted (Figs. 13 & 14). 1. Ensure that there is power to the boiler (though it is not necessary for there to be any heating demand). Turn the Selector Switch (Fig. 13) to the boiler ON (central heating & domestic hot water) position. Curve 35 Curve 15 Curve 5 Curve 2. The Central Heating Control Knob should be turned clockwise to the position in Fig. 14 which corresponds with the desired curve as shown on the graph below. Curve 30 Curve 25 Curve 20 Fig. 14 Curve 35 Curve 30 Curve 25 Curve 20 Curve 15 3. Normally the display will show the current temperature of the water in the boiler (e.g. 41 C, Fig. 15). As the knob is turned the display will show the selected curve (Fig. 16). For example, if Curve 35 is selected (Fig. 16), at an outside temperature of 0 C the boiler flow temperature will be 80 C. Consider the type of dwelling and discuss with the user their requirements to determine the most appropriate curve. Fig. 15 4. Explain to the user how to select a different temperature curve. Fig. 16 80 75 Boiler Flow Temp. ( C) 70 65 60 55 50 45 40 35 30 35 30 25 25 20 15 5 0-5 - 20 15 Outside Temp. ( C) 6 7687799-01 (2/18) 5-15 -20

M2 low voltage terminal strip IFOS Cable Connect to 4 & 5 1 2 3 4 5 6 7 8 9 Fig. 17 7.0 Connecting the Sensor & Setting the Curve - boiler Group B Connecting 1. Ensure the electrical supply to the boiler is isolated. Undo the securing screws and lift the case front panel off. 2. Disengage the securing tab and hinge the control box downwards. Undo the terminal block cover securing screw and remove the cover. 3. Connect the IFOS cable to 4 & 5 on the M2 low voltage way terminal strip (Fig. 17) then refit the cover. There is no polarity. P R Note the boiler setting on the identifying label supplied. It must then be signed and affixed to the front of the boiler or inside the control cover facia. The label must be readily accessible without removing the boiler casing or any other disassembly. This label is required to enable SAP/energy assessors to identify that a weather compensation device is installed. Fig. 18 Central Heating Temperature Adjustment Buttons Setting 4. Ensure that there is power to the boiler. 5. The Central Heating temperature buttons & are used to select the desired curve as shown on the graph. Boiler Flow Temp. ( C) 80 75 70 65 60 55 50 45 40 35 30 20 90 80 70 60 50 40 30 20 00 15 5 0-5 - -15-20 6. Normally the display will show the current temperature of the water in the boiler (e.g. 41 C). As the buttons are pressed (Fig. 18) the curve identification code the will be shown, from 00 to 90. For example, if Curve 40 is selected (Fig. 19), at an outside temperature of 0 C the boiler flow temperature will be 80 C. Consider the type of dwelling and discuss with the user their requirements to determine the most appropriate curve. Fig. 19 Outside Temp. ( C) 7. Explain to the user how to select a different temperature curve. For more information scan the code:- 7687799-01 (2/18) 7

IFOS Cable Connect to 4 & 5 8.0 Connecting the Outdoor Sensor - boiler Group C 1. Ensure that the electrical supply to the boiler is isolated. Hinge down the control box and remove the boiler terminal block cover. 9 8 7 2. Connect the IFOS cable to 4 & 5 on the M2 low voltage way terminal strip (Fig. 19). There is no polarity. 6 5 4 3 2 1 M2 low voltage terminal strip Fig. 19 Note the boiler setting on the identifying label supplied. It must then be signed and affixed to the front of the boiler or inside the control cover facia. The label must be readily accessible without removing the boiler casing or any other disassembly. This label is required to enable SAP/energy assessors to identify that a weather compensation device is installed. 3. Refit the boiler terminal block cover, hinge back the control box and replace the boiler case. /P R /R EcoBlue 9.0 Setting the parameters for the outdoor sensor - boiler Group C Fig. 20 + + With the IFOS fitted, the boiler central heating flow temperature is adjusted automatically to accommodate the change in heat required to optimise the efficient performance of the boiler whilst maintaining a comfortable room temperature. The central heating buttons on the boiler adjust a simulated room temperature used for this optimisation. P03 2 1.75 1.5 1.25 1 0.75 0.5 0.25 2.25 2.5 2.75 3 3.5 4 Boiler Flow Temperature C 0 90 80 70 60 50 40 30 This functionality requires the setting of three parameters on the boiler, to suit the heating system and the optimisation can be adjusted by the user with the central heating control buttons on the boiler control panel. The parameters which must be set are: P06 = Minimum CH Flow temperature. This should be set to the lowest temperature at which the heat emitters are effective. P07 = Maximum CH Flow temperature. This should be set to the highest flow temperature which can be permitted in the CH circuit. P03 = Heating curve (Fig.21). This should be calculated using the following formula: Fig. 21 C -30-25 -20-15 - -5 0 5 15 20 Outdoor Temperature P07 - T room where: P03 = T room - T outmin T room = The normal room thermostat setting used by the customer (if this is in doubt or unknown use 20 C), and the temperature to be set on the boiler. Consider the type of dwelling and discuss with the user their requirements. T outmin = The minimum expected outdoor temperature, as used for sizing the heating system (recommended value 5 C) NOTE: parameter P03 can be set to a value in the range 0-4 in increments of 0.02. 8 7687799-01 (2/18)

IFOS - In Flue Outdoor Sensor Kit 9.0 Radiator Example P03 = Boiler flow temperature ( C) 90 Example Parameter Recommendations: P07 - Troom Troom - Toutmin 20 Troom 15 80 Setting the parameters for the outdoor sensor (cont) - Group C = 80-20 20 - (-5) = 2.4 25 P07 = 80 C 70 60 50 P06 = 50 C 40 Radiator systems (Fig 22): P03 = 2.4 P06 = 50 C P07 = 80 C If the IFOS is fitted to a boiler serving a low temperature system or underfloor heating please contact Baxi Customer Support for advice. 30 20 0-25 -20-15 - Fig. 22 For more information scan the code:- -5 0 5 Outside Temperature ( C) 15 20 25 30 35 IMPORTANT: Do not change any other parameters other than those described in these instructions otherwise the warranty of this kit and the boiler could be invalidated. The parameters are set as follows (See Fig. 20): 1. Ensure that there is power to the boiler. 2. Press and hold and until P02 is displayed on screen. 3. Press and hold until On is displayed. 4. Press or to scroll until the required parameter is displayed. 5. Press to edit the program. Press or to change the setting to the desired value. Press to confirm selection. 6. Repeat steps 4 and 5 as required for each parameter. 7. When parameter changes are complete press to return to the normal operating screen. NOTE: If at any time when setting parameters an error is made or it is desired to restart the process press..0 Operating instructions with outdoor sensor - boiler Group C 1. While there is no DHW demand the boiler flow temperature is limited according to the heating curve setting 2. If the or are pressed while CH is enabled, the display shows a simulated room temperature set point. Ensure that this set point is the same as the room thermostat to ensure optimal outdoor weather temperature compensation operation. The user can adjust this temperature should the optimisation not suit their requirements. 3. While DHW is enabled, if the or buttons are pressed, the display will show the DHW temperature set point. 4. Explain to the user how to select a different temperature slope. 7687799-01 (2/18) 9

11.0 Fault Finding - boiler Group C No or poor CH performance or error code displayed Error displayed NO YES Check outside sensor wiring for damage or short circuit. Otherwise replace Outdoor Sensor. If any other error code is displayed refer to appliance manuals for further details then continue with CH fault finding. Review section 9: Has the CH set point been adjusted? NO YES Set the CH set point according to section 9 Review Section 9: Setting the parameters for the outdoor sensor. Has a sufficient heating curve value been set? YES NO Adjust heating curve value to a sufficient value according to section 9. Check all system wiring and components. Check appliance manuals for further detail. 7687799-01 (2/18)

Sealing plug Conical sealing gland For more information scan the code:- Fig. 27 80 75 70 65 60 55 50 45 40 35 30 25 20 20 Slope 30 X9 Fig. 26 Slope 20 W Br Gn Bk R Fig. 24 Bl Gy Bl G/Y Br 1 2 345 12 34567 1 1 2 1 2 3 X12 X11 X X5 X3 X13 Gy R J On W Bk Off 3 2 1 Vt Br Slope 12 IFOS cable Bl TIMER Bk Br X2 X1 MAINS X8 X14 X7 X6 X4 F2 0.5A N L IFOS Cable Slope 5 230V - 50Hz 15 5 0-5 Fig. 25 12.0 Connecting the Sensor & Setting the Slope - boiler Group D Connecting 1. Ensure the electrical supply to the boiler is isolated. The IFOS cable must be routed via the conical sealing gland in the lower panel (Fig. 24). Remove the plug from the top of the gland and pass the cable through the gland. Refit the plug to ensure a seal. Within the boiler the cable should be routed to the left side. 2. Fully undo the two screws retaining the electrical cover at the bottom of the front panel. Remove the cover (Fig. 25). 3. Connect the IFOS cable to the grey T-OUT connector (X14 Fig. 26). There is no polarity. Refit and secure the cover. Note the boiler setting on the identifying label supplied. It must then be signed and affixed to the front of the boiler or inside the control cover facia. The label must be readily accessible without removing the boiler casing or any other disassembly. This label is required to enable SAP/energy assessors to identify that a weather compensation device is installed. Setting 4. Ensure that there is power to the boiler (though it is not necessary for there to be any heating demand). 5. The Central Heating Control Knob should be turned clockwise until the value which corresponds with the desired slope (as shown on the graph - Fig. 27) is displayed (Fig. 28). NOTE: If a Baxi usense smart thermostat is connected to the boiler the slope must be set using the usense App. The boiler display will not show the slope but will still be active. OFF Fig. 28 OFF MAX OFF MAX MAX OFF RESET MAX Knob position for slope 5 OFF MAX OFF MAX Knob position for slope 20 When IFOS connected icon displayed 6. Normally the display will show the current temperature of the water in the boiler (e.g. 41 C). As the knob is turned the display will show the selected slope (Figs. 27 & 28). For example, if Slope 12 is selected (Fig. 27), at an outside temperature of 0 C the boiler flow temperature will be 80 C. Consider the type of dwelling and discuss with the user their requirements to determine the most appropriate curve. 7. Explain to the user how to select a different temperature slope. 7687799-01 (2/18) 11

IFOS Cable 1 2 3 4 5 6 7 8 9 13.0 Connecting the Sensor & Setting the Curve - boiler Group E Connecting 1. Ensure the electrical supply to the boiler is isolated. 2. Hinge down the control box and unclip the terminal block cover (Fig. 29). 1 2 3 4 5 M1 Fig. 29 3.Connect the IFOS cable to 4 & 5 of terminal M2 (Fig. 29). 4.Leave sufficient slack in the cable to allow the control box to be hinged fully open then tighten the gland nut. 5. Refit and secure the cover. Boiler Flow Temp. ( C) 90 80 70 60 50 40 30 80 75 70 20 65 60 55 50 45 40 35 00 30 20 15 5 0-5 - -15-20 Outside Temp. ( C) Fig. 30 Max Fig. 31 90 80 Min 00 20 30 40 50 60 70 Note the boiler setting on the identifying label supplied. It must then be signed and affixed to the front of the boiler or inside the control cover facia. The label must be readily accessible without removing the boiler casing or any other disassembly. This label is required to enable SAP/energy assessors to identify that a weather compensation device is installed. Setting 1. Ensure that there is power to the boiler (though it is not necessary for there to be any heating demand). 2. The central heating control knob should be turned clockwise to the position which corresponds with the desired curve as shown on the graph (Fig. 30). For example, if Curve 40 is selected (Fig. 30), at an outside temperature of 0 C the boiler flow temperature will be 80 C. Consider the type of dwelling and discuss with the user their requirements to determine the most appropriate curve. NOTE: If a Baxi usense smart thermostat is connected to the boiler the curve must be set using the usense App. Min 4. Normally the display will show the current temperature of the water in the boiler. As the knob is turned the display will show the selected curve (Fig. 31 & 32). Max Curve 40 5. Explain to the user how to select a different temperature curve. Fig. 32 For more information scan the code:- 12 7687799-01 (2/18)

14.0 Notes 7687799-01 (2/18) 13

14.0 Notes 14 7687799-01 (2/18)

15.0 User Information NOTE: The Central Heating Temperature Control will NOT operate in the same way as described in the User Instructions supplied with the boiler! 1. Your installation has been fitted with an In Flue Outdoor Sensor (IFOS) that acts as a Temperature Compensation Device. 2. The IFOS enables the boiler to respond effectively to changes in the ambient temperature outside the dwelling. 3. As the outside temperature decreases, the boiler flow temperature will increase, thus maintaining comfort levels within the dwelling. 4. Your installer will have set the boiler according to the anticipated outside temperature range. 5. If you require a different comfort level consult your installer or follow the instructions in this booklet. See the list on page 2 to determine which Section is relevant. Do not attempt to adjust the boiler if you are unsure how to proceed! For more information go to:- www.baxi.co.uk/ifos 7687799-01 (2/18) 15

Baxi Customer Support 0344 871 1545 Baxi Brooks House, Coventry Road, Warwick, CV34 4LL baxi.co.uk e&oe All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. For more information go to:- www.baxi.co.uk/ifos 7687799-01 (2/18)