INSTALLATION GUIDE - FURRINGS OF WOOD

Similar documents
Designpanel ACOUSTIC PERFORATED PLASTERBOARD WITH AIR PURIFYING FOR CEILINGS AND WALLS

Knauf Direct Bonding and Metal Furring

Carbon Film Installation Instructions

Siding Installation Guide

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

SonusClip Installation for walls or ceilings on wood or steel framing. Installation Instructions for Wall & Ceilings

CEILINGS BACKSPLASHES WALLS PROJECTS INSTALLATION GUIDE.

CORNICE FOR INDIRECT LIGHTING

GENIE CLIP TYPE RST. Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS

C08. S05. P02 P05 Decorative effects

Selfie. Curving flexibility. Smooth and quiet rollers. Exceptionally easy installation.

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

TOYOTA RAV BODY SIDE MOLDING Section I - Installation Preparation

CONCEALED CEILING SYSTEMS INSTALLATION GUIDE

Radiant Ceiling. Metawell Klimadecke 1

TOYOTA CAMRY/CAMRY HV BODY SIDE MOLDING Section I - Installation Preparation

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

TOYOTA COROLLA BODY SIDE MOLDING Section I - Installation Preparation

EZ Base is a high-density panel base system that replaces traditional compacted aggregate-base installations.

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

INFRARED BUILDING HEATING BOARDS

Section Plaster Accessories

CONGRATULATIONS! TABLE OF CONTENTS. Introduction. Features and Benefits. Parts Guide 4. Installation Considerations 4. Installing the Loudspeakers 6

Concealed Ceiling Systems

INSTALLATION INSTRUCTIONS FOR. ProTek RIGID VINYL WALLCOVERING

amuheat Cable Mat floor heating systems Installation Manual CM02-12

Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing

ACOUSTIC CEILINGS CREATIVITY. Gyptone BIG Curve CURVED ACOUSTIC CEILINGS INTEGRATION OF LIGHT. Gyptone acoustic ceilings

WARNING. Before installing your siding, inspect the delivered wood. All installed material shall be considered accepted.

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

raymagic quad Installation, Operation & Maintenance Manual

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture.

RADIANT HEATING AND COOLING SYSTEMS Produced by FRENGER SYSTEMEN BV

c. Oko-Tex (European environmental health standard)

TECTUM Direct-Attach Ceiling and Wall Panels Assembly and Installation Instructions for 1" Thick Direct-Attach Wall and Ceiling Panels

Introduction. Please read the following instructions carefully before commencing installation.

INSTALLATION INSTRUCTIONS

Nozzle Band Heaters. Construction Characteristics. Single Port Igloo TM Covers

CONGRATULATIONS! TABLE OF CONTENTS. Introduction. Features and Benefits. Parts Guide 4. Installation Considerations 4. Installing the Loudspeaker 6

decorating ideas under

INSTALLATION INSTRUCTIONS

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE

Inde-Pendants Family. 32L Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

Ceiling Systems 6 Intex Price Guide

Smoke extraction duct of sheet steel

Urbanscape Landscaping Solutions

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com

Level 6 Using Physics: Investigate how physics knowledge is used in a technological application.

User Guideline LMD-E 200 LMD-E 200. Hook-On Ceiling Hook-On / Lay-On Type ceiling panels - removable Standard installation.

Perimeos. Ceiling Recess. decor. systems

Timber Venetians Manual

Guidelines for Earthquake Bracing of Residential Water Heaters

INSTALLATION AND OPERATION MANUAL FOR HUUM DROP ELECTRIC SAUNA HEATER

Tectum Direct-Attach Ceiling and Wall Panels Assembly and Installation Instructions for 1-Inch Thick Direct-Attach Wall and Ceiling Panels

Comfortline Ceiling Heating Foils INSTALLATION INSTRUCTIONS. Rev Mar-2016

chiang mai What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

WaterVue Bluetooth Bathroom Music System

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide

INSTRUCTION FOR ASSEMBLY. 150x200 h Traditional sauna cabin

VELVET MARMORINO. Fine natural mineral lime finish

INSTALLATION MANUAL. Decoration Panel BYCP125K-W1 MODELS

DIY Cabinet Painting Guide

PAL-245 Precision Architectural Loudspeakers

pushing the tube into the rear of the water outlet housing with a slight twisting motion to evenly distribute the adhesive. After cleaning off any ext

Installation & WillowCreekPavingStones.com POWER TOOLS YOU MAY NEED TO RENT PROJECT COMPONENTS. Willow Creek pavers Aggregate base material

Royden. Look how easy it is to roll out the heat

Dear Customer BLANCO - 3 -

PAVER BLOCK FIXING INSTRUCTIONS VYARA ROTATIONAL INTERLOCK

PAL-265 Precision Architectural Loudspeakers

INSTALLATION GUIDE ISODRIVE MOTOR. ST - 900m 3 /hr.

EXAMPLE SPECIFICATION ONLY

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

SPEEDI DUCT AND HVAC INSTALLATION ACCESSORIES

OP44-1 REV 2: Removed depiction of air intake hole in the CB-907A Right Aft Case Baffle.

Packaged Coldroom. Installation Instructions. Operating instructions

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.

INSTALLATION GUIDE CEILING HEATING FOIL ECOFILM C FLOOR HEATING FOIL ECOFILM F F RESISTANCE OUTPUT OUTPUT

INSTALLATION INSTRUCTIONS ONE LARGE ZONE

Application Instructions

Fire Sprinkler Freeze Protection Design / Install Guide

FIRE TUBE Fire protection for process pipes and structural steel

DUCTING FOR HRV SYSTEMS The distribution of airflows

IdealFILM. Do-It-Yourself Installation Manual

CEILING FED RISER RAIL KIT. Installation Guide. tritonshowers.co.uk/digital

Be inspired... hanging wallpaper. CONTACT US ON 0861 SHAVES OR VISIT OUR WEBSITE AT FOR A STORE NEAR YOU

Casper Hoop House Workshop 12 Ft. x 36 Ft. Del Jimenez. 12ft x 36ft Hoop House 2

CEILING SYSTEMS. METALWORKS Tin. Between us, ideas become reality

WATCH OUT! UNDERNEATH THE WOODEN FLOORING IS A 230 VOLT HEATING FOIL SYSTEM! NEVER DRILL OR SCREW INTO THE FLOOR!

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

ALUMINUM. ELEVATED. CEDAR RENDITIONS DESIGN SERIES INSTALLATION INSTRUCTIONS

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

INSTRUCTION FOR ASSEMBLY. 200x200 v Traditional sauna cabin

Report Number BTC 15450A

CHILLED & HEATED CEILINGS

R. K. Ceilings (p) Ltd.

TRADE HomePro connect with the best

Cooling Strip Model SPB

Transcription:

DESIGNPANEL INSTALLATION GUIDE - FURRINGS OF WOOD Legend: A The furring should be min. 60 mm wide at the short end joints (if wood is used; the steel furring can be min. 45 mm). The remaining furring can be 45 mm wide. Screw (SN 3.5 x 30) Max. Fig. 1 A Best Practice: Handling the panels with care will avoid damage and surface contamination prior to painting and thereby ensure a good end result. 1000 mm FURRING CEILING LAYOUT AND FURRING SYSTEM Furrings can be of wood or steel profiles; CD2 system can also be used as substrate - for more details please see page 92. Divide the ceiling surface from the centre of the room or in accordance with the existing ceiling plans. Also see the sections Fire and Acoustics on page 95. As a rule, the furring must be at right angles to the longitudinal direction of the elements at centres of to ensure that the panels are properly supported. Ensure full support for the short edges (e.g. steel band) on longitudinal furrings. Please note that expansion joints must be established on extensive ceiling surfaces at max.intervals of 15 metres in both directions. See detailed drawings on knaufdanoline.com Also see the sections Fire and Acoustics on page 95. 90 Knauf Danoline Non-demountable Ceiling

DESIGNPANEL INSTALLATION GUIDE - FURRINGS OF STEEL (P45-S25) Fig. 1 E C A G D B F G Legend: Primary profile P45 Secondary profile S25/85 Perimeter profile MSK 70 Screw (F/F 13) Hanger (not Knauf Danoline) A = Max. B = Max. C = Max. 1200 mm D = Max.1200 mm E = Max. 1200 mm F = Max. 1200 mm G = Min. 80 mm Best Practice: Handling the panels with care will avoid damage and surface contamination prior to painting and thereby ensure a good end result. Max 400 mm CEILING LAYOUT INSTALLING THE WALL PROFILE Divide the ceiling surface from the centre of the room or in accordance with the existing ceiling plans. Mark out. The furrings should usually run across the longitudinal direction of the element with a C-C distance of. This will ensure that the end edges are fully supported. Ensure full furring support at short edge joints for longitudinal furrings (e.g. steel band). Install the wall profile MSK70. Choose the method of fixing in accordance with the substrate. Please note that expansion joints must be established on extensive ceiling surfaces at max.intervals of 15 metres in both directions. Where conditions indicate an increased risk of movement in a building, this must be taken into account by reducing the distance between expansion joints. PRIMARY PROFILES/HANGERS SECONDARY PROFILES Install primary profiles every 1200 mm centres (max). Fix the secondary profiles to the primary profiles at every 300 mm. Use 2 screws (F/F 13) in each connection. Using rigid or strap hangers. Connect hangers to primary profile with 2 screws (F/F 13). Knauf Danoline Non-demountable Ceiling 91

INSTALLATION GUIDE - FURRINGS OF STEEL (CD2) Fig. 1 E G A B F Legend: C D Wall profile UD 28/27 Screw SN 3.5 x 30 CD profile 60/27 Cross fitting Nonius hanger (type depending on installation depth) Panel edge H A = Max. C = Max. 900 mm E = Max. 900 mm G = Min. 80 mm B = Max. D = Max.900 mm F = Max. 900 mm H = Min. 80 mm Best Practice: Handling the panels with care will avoid damage and surface contamination prior to painting and thereby ensure a good end result. Max 400 mm CEILING LAYOUT Divide the ceiling surface from the centre of the room or in accordance with existing loft plans. The furrings should usually run across the longitudinal direction of the element with a C-C distance of. This will ensure that the end edges are fully supported. Ensure full furring support at short edge joints for longitudinal furrings (e.g. steel band). Please note that expansion joints must be installed in both directions at an interval of maximum 15 metres when working with large ceiling surfaces. Please see detail drawings on knaufdanoline.com. Where conditions indicate an increased risk of movement in a building, this must be taken into account by reducing the distance between expansion joints. INSTALLING THE WALL PROFILE Mark out. Install the wall profile UD 28/27. Choose the method of fixing in accordance with the substrate. 92 Knauf Danoline Non-demountable Ceiling

DESIGNPANEL INSTALLATION GUIDE - FURRINGS OF STEEL (CD2) HANGERS PRIMARY PROFILES Secure the upper part to the construction above it at 900 mm c/c. Choose the fixings in accordance with the substrate. Connect the two parts of the hangers with two split pins, one immediately above the other. Secure the lower part to the primary profile. JOINING CD-PROFILES SECONDARY PROFILES Join the CD profiles with the help of length connectors. Place a cross fitting on the primary profile. Press the underlying secondary profile into it. Adjust the locations of the secondary profiles and lock the cross fitting. Se distances in figure 1. Knauf Danoline Non-demountable Ceiling 93

DESIGNPANEL INSTALLATION GUIDE - PANELS AND FILLING = first filling = filling tape = second filling = third filling INSTALLATION FILLING Install the first row of panels with the help of string. Apply the first layer of filler (Easy Filler Light). Ensure that it is pressed firmly between the panel edges if there is a gap between them. See distances in figure 1 page 90-92 all according to furring. Screws must be fixed 10 mm from the long panel edge and 15 mm from the end panel edge. Panel length and breadth have a tolerance of +0/-4 mm. When installing, take into account the location of perforation fields to ensure they are flush in both directions. This can mean that there can be up to 4 mm between panel edges. The panels are supplied undersized and must be installed at distances of up to 4 mm from each other to ensure that it is possible to insert filler all the way up between the edges of the panels. Cut the elements to size from the front with a fine-toothed saw. Designpanel should always be installed with bevelled edge to bevelled edge (same applies for friezes). We recommend using Plan-4 Board for friezes. If joints with cut edges cannot be avoided, match cut edge to cut edge. We recommend sanding and priming cut edges before installation. Always maintain a gap between the panel edges for a 3-5 mm grout seal. Apply Knauf Uniflott (without paper strips) as grout. Alternatively, the perforated Designpanel boards can run right to the wall, using filler to fill the perforated holes when an unperforated surface is required. In such instances, the perforated holes should be sprayed first with deep primer and then filled with Knauf Uniflott, before finishing with Knauf Uniflott Finish. Avoid filler in the perforated holes (can be masked with a sensitive masking tape, but check that the tape can be removed without damaging the cardboard surface before starting). Apply filler tape to the wet filler. The first filling and application of filler tape can be carried out in a single, very simple operation by using a Mini Bazooka. Allow the filler to dry. Make sure that the filler is completely dry before sanding. Sand with fine sandpaper. Be careful not to damage the cardboard surface. Apply the second layer of filler (Easy Filler Light). Allow the filler to dry. Make sure that the filler is completely dry before sanding. Sand with fine sandpaper. Be careful not to damage the cardboard surface. Apply the third layer of filler (Easy Filler Light). Make sure that the filler is completely dry before sanding. Sand with fine sandpaper until the joint is completely smooth. Be careful not to damage the cardboard surface. 200 mm 900 mm 450 mm SCREW DISTANCES 900 X 2400 (TANGENT) 200 mm Fix the panels acoording to the template above. SCREW DISTANCES 900 X 2700 Fix the panels acoording to the template above. 600 mm 600 mm 200 mm FILLING SCREW HOLES Check that the screws have been countersunk. Apply filler (Knauf Uniflott Finish or Easy Filler). Overfill slightly. SCREW DISTANCES 1200 X 2400 Fix the panels acoording to the template above. 94 Knauf Danoline Non-demountable Ceiling We recommend the use of Knauf Danogips Acoustic filling knife for holes in order to avoid filler getting into the perforation holes. FILLING PERFORATED HOLES spray the holes first with deep primer and fill with Knauf Uniflott. Finish off with Knauf Uniflott Finish.

INSTALLATION GUIDE - PAINTING PAINTING Make sure that the filler is completely dry and the surface is smooth and free from dust. Priming should be carried out in accordance with the paint manufacturer s instructions. Apply the paint with a roller so that the acoustic felt on the perforated panels is not sealed. Use a fine mohair roller. Make sure that the paint is not too thick and avoid applying too much paint at a time. Spraying cannot be recommended as this could influence the acoustic properties of the panels. ACOUSTICS A perforated gypsum panel will lose its acoustic function if the perforations are blocked (this applies to the front and back of the panel). Where applicable, a vapour barrier should therefore always be placed behind the furrings so that it does not come into contact with the back of the perforated panel. When installing Designpanel on a fixed surface we recommend filling the cavity between the back of the panel and the furring with mineral wool. This is primarily to ensure low frequency sound absorption. FIRE If there is a requirement for BD30 follow the instructions for this construction. The furring should be dimensioned in accordance with the load in question and should be at least 45 mm in width. Where BD30 constructions are concerned 25 x100 mm furrings should be used. INSTALLATION GUIDE - CURVED PANELS Apply water on the front face and leave for 30 minutes. If necessary the panel can be covered in plastic to assist the panel in absorbing the water. Lay the panel over a template. Secure the panel on one side of the template. Press the panel against the template using a batten, moving it every 100 mm. Secure the panel on the other side of the template. Make sure that the panel is fully dry before mounting or closing the construction. To minimize the risk of mold formation during the process, make then sure that a fast drying of the boards is present. A good ventilation with high air exchange and relative high temperature is needed and with advantage the boards can be bended and dried out before mounting. Knauf Danoline Non-demountable Ceiling 95

DETAILS DESIGNPANEL WITH 1 LAYER FURRING Mineral wool Furring Designpanel Vapour barrier Filling, tapered edges Furring Designpanel Vapour barrier Filling, tapered edges DESIGNPANEL WITH CROSS-FURRING Mineral wool Furring Designpanel Vapour barrier Mineral wool Mineral wool Furring Designpanel Vapour barrier Mineral wool 96 Knauf Danoline Non-demountable Ceiling

ACCESSORIES PRODUCT NAME SAP NO. W x L x H (mm) Consumption per. m² Primary / secondary CD 60/27-profile 3294 60 x 4000 x 27 4.6 m Wall angle UD 28/27 181589 28 x 3000 x 27 1.0* Length connector CD 60/27 181080 59 x 80 x 28 1.1 pcs. Accessories for system CD2 Cross-fitting 3446-3.3 pcs. Split pin for hanger 198907-2.6 pcs. Nonius hanger lower 198904-1.3 pcs. Nonius hanger upper 85mm 198905 125-185 Nonius hanger upper 135mm 198906 135-235 Nonius hanger upper 235mm 198923 235-340 Nonius hanger upper 340mm 198924 340-440 Nonius hanger upper 440mm 198925 440-540 Nonius hanger upper 540mm 198926 540-640 1.3 pcs. Nonius hanger upper 640mm 198927 640-740 Nonius hanger upper 740mm 198928 740-840 Nonius hanger upper 840mm 198929 840-940 Nonius hanger upper 940mm 198930 940-1040 Accessories for system P45-S25 MSK 70 Perimeter profile 181029 181030 2500 3600 1.0 m* P45 Primary profile 181684 3600 0.85 m S25/85 Secondary profile 181685 3800 3.6 m F/F13 Screw 2017 13 8 pcs. Screw SN3.5x30 3503 3,5 x 30 20 pcs. Joint Filler - Easy Filler Light 235309-0.35 kg Uniflott Finish 129801 8 kg 0.1 kg Filling tape 314828-1.5 m Mini Bazooka 181232 - - Filling knife 73962 - - *Depending on room size. Knauf Danoline Non-demountable Ceiling 96_97 97

PATTERNS DESIGNPANEL 900 X 2700 Following perforation patterns are available for Designpanel Globe, Quadril og Micro 900 x 2700 mm. G1F, Q1F, M1F G1F, Q1F, M1F Perforation percentage A B C D E Designpanel G1F 9.8% 60 780 60 780 120 Designpanel Q1F 13% 60 780 60 780 120 Designpanel M1F 9.8% 62.5 775 62.5 775 125 G2F*, Q2F, M2F G2F, Q2F, M2F Perforation percentage A B C D E Designpanel G2F 7.4% 60 330 60 330 120 Designpanel Q2F 10.2% 60 330 60 330 120 Designpanel M2F 7.1% 62.5 325 62.5 325 125 PATTERNS DESIGNPANEL 1200 X 2400 Following perforation patterns are available for Designpanel Globe, Quadril og Micro 1200 x 2400 mm. G2F, Q2F, M2F G2F, Q2F, M2F Perforation percentage A B C D E Designpanel G2F 8.6% 60 480 60 480 120 Designpanel Q2F 11.6% 60 480 60 480 120 Designpanel M2F 8.4% 62.5 475 62.5 475 125 *Non standard 98 Knauf Danoline Non-demountable Ceiling

PATTERNS DESIGNPANEL 900 X 2400 Following perforation patterns are available for Designpanel Tangent 900 x 2400 mm. T3L1 60 180 120 Perforation percentage T3L1 15.8% 900 70 2400 2260 T3L2 60 180 120 Perforation percentage T3L2 15.0% 900 70 1060 140 2400 T3L4 60 180 120 Perforation percentage T3L4 13.3% 900 70 460 140 460 140 2400 Knauf Danoline Non-demountable Ceiling 99