Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

Similar documents
VIEW500 USER-FRIENDLY STANDARD OTDR

MINI2 MOST ACCURATE COMPACT OTDR

VIEW500 FASTEST STANDARD OTDR

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

Qualification Test Report LC Duplex Adapter For LC Cutouts

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Fiber Optic Patch Cord and Pigtails

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

Test Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

ENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING

THE ENTRY-LEVEL SOLUTION DESIGNED FOR ALL YOUR TESTING NEEDS

Fibre Specification Standards

FiberExpress Solutions

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Product Specification

Intelligent Optical Link Mapper (iolm)

M700-Series Multifunction OTDR

Core Alignment All In One Fusion Splicer

MaxTester 730C PON/METRO OTDR OPTIMIZED FOR FTTx/MDU FIBER DEPLOYMENTS AND TROUBLESHOOTING, SUITABLE FOR METRO

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Intelligent Optical Link Mapper (iolm)

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

MaxTester 715B Last-Mile OTDR

Best Practice Briefing

Connections You Can Count On.

Jul07 Rev C

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

Ensuring Cabling Performance in the Customer-Owned Outside Plant

M210 Multifunction Micro OTDR

M210 Multifunction Micro OTDR

MaxTester 730B PON/METRO OTDR

MaxTester 730B FTTx/MDU PON OTDR

MaxTester 715B Last-Mile OTDR POINT-TO-POINT (P2P) LINKS, LAST-MILE INSTALLATION AND TROUBLESHOOTING

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

OZ Optics Limited. Fiber Optic Attenuators. June 2018

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

MaxTester 715B Last-Mile OTDR POINT-TO-POINT (P2P) LINKS, LAST-MILE INSTALLATION AND TROUBLESHOOTING

VePAL FX300 Fiber Expert OTDR

MaxTester 715B Last-Mile OTDR

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Clearlite Photonic Fibers

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

ENCIRCLED FLUX (EF) TEST SOLUTIONS

AV6416 OTDR. Product Overview: Main Features:

Intelligent Optical Link Mapper (iolm)

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

palmotdr Series Handheld OTDR

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

FHO5000 Series Triple-Proof OTDR

Noyes OFL 250B Specs Provided by

M700-Series OTDRs. or (800) , (603)

M310 Data Center OTDR

Cooled Butterfly 980nm Pump Laser Module

Instruments Designed for POF & Fibre Optic Cable Testing

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

Apr06 Rev A

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne

740C xwdm OTDR Series C-BAND DWDM AND 18-WAVELENGTH CWDM TUNABLE OTDR SERIES FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

MTTplus Modular Test Platform

Fiber Optic Distribution Cables (6-144 Fibers)

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

818 Series Low-Power Detectors

MT-RJ Optical Fiber System Field Testing

4120 Fire Alarm Network Reference

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

FLX380-30x FlexTester3 OTDR


M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

GRANDWAY FHO5000 series OTDR

OLTS vs OTDR Tier-2 Expert; How far from Tier-1?

LCS 2 YOUR digital infrastructure

OPX-350 Series. Fiberizer Cloud. Universal Performer for Fiber Testing. Add value with. Test and Measurement in Fiber Optics

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

NG4access ODF Platform Standard Chassis Installation Manual

Dome Fiber Optic Closure SC-221

Fiberizer IIT-6000 Series

Remote fiber testing to improve SLA s

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

AE2200 FTTx Multi-Function Meter

AS/NZS ISO/IEC :2012

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Transcription:

Attenuators Build Out Attenuators Product Facts A range of fixed attenuation values. Standard values of 1 through 20 and 25dB UPC and APC offer Excellent Return Loss LC, SC, FC, ST, and D4 styles Attenuation is wavelength independent and polarization insensitive Low PDL Low modal noise High reliability Very low reflectance Vibration resistant Dual Window and Broadband Bandpass End face geometry per GR-326 Designed to comply with Telcordia GR-910 Applications Power leveling in DWDM transmission systems Test and Measurement Power attenuation at the receiver Tyco Electronics high performance Build Out Attenuators utilize a unique all-fiber construction to absorb the optical signal. By employing a Tyco Electronics technology, the design minimizes Customizable Features Attenuation tolerance Attenuation values in 1dB increments Labeling reflectance, attenuation tolerance, and PDL while maximizing reliability, environmental stability, and power handling. There are no filters, air gaps, or core mismatches. Specifications Attenuation Values 1-20dB and 25 db (Fixed) Reflectance -55 and -65dB for UPC and APC polish, respectively Operating Temperature -40 C to +75 C Vibration Resistance < 0.1 x attenuation Kitting/Packaging Available Collateral Wavelength Dependent Loss Test reports qualifying product to Telcordia GR-910 (2004) Application Specification 114-1129 Reflectance: UPC to -55 db max. APC to -65 db max. Installation/Cleaning Instruction Sheet 408-8895 Product Specification 108-2099 Customer Drawings 178

Note: Additional s LC Attenuators, Build Out LC/UPC 1 1693560-1 2 1693560-2 3 1693560-3 4 1693560-4 5 1693560-5 6 1693560-6 7 1693560-7 8 1693560-8 9 1693560-9 10 1-1693560-0 11 1-1693560-1 12 1-1693560-2 13 1-1693560-3 14 1-1693560-4 15 1-1693560-5 16 1-1693560-6 17 1-1693560-7 18 1-1693560-8 19 1-1693560-9 20 2-1693560-0 25 2-1693560-5 Note: Part Numbers are RoHS compliant except: Indicates non-rohs compliant. Attenuators, WDMs, and Switches 6 179

SC Attenuators, Build Out SC/UPC Note: Additional s SC Attenuators, Build Out Style Fixed Value SC/APC 8 Note: Additional s * 9 APC Available (417496-X) 0 9-5209943-9 1 5209943-1 2 5209943-2 3 5209943-3 4 5209943-4 5 5209943-5 6 5209943-6 7 5209943-7 8 5209943-8 9 5209943-9 10 1-5209943-0 11 1-5209943-1 12 1-5209943-2 13 1-5209943-3 14 1-5209943-4 15 1-5209943-5 16 1-5209943-6 17 1-5209943-7 18 1-5209943-8 19 1-5209943-9 20 2-5209943-0 25 2-5209943-5 0 db: 0.50 db max 1 5209597-1 2 5209597-2 3 5209597-3 4 5209597-4 5 5209597-5 6 5209597-6 7 5209597-7 8 5209597-8 9 5209597-9 10 1-5209597-0 11 1-5209597-1 12 1-5209597-2 13 1-5209597-3 14 1-5209597-4 15 1-5209597-5 16 1-5209597-6 17 1-5209597-7 18 1-5209597-8 20 2-5209597-0 25 2-5209597-5 Reflectance -60 db 0 9-5209250-9 1 5209250-1 2 5209250-2 3 5209250-3 4 5209250-4 5 5209250-5 6 5209250-6 7 5209250-7 8 5209250-8 9 5209250-9 10 1-5209250-0 11 1-5209250-1 12 1-5209250-2 13 1-5209250-3 14 1-5209250-4 15 1-5209250-5 16 1-5209250-6 17 1-5209250-7 18 1-5209250-8 19 1-5209250-9 20 2-5209250-0 25 2-5209250-5 0 db: 0.50 db max. 1 5417021-1 2 5417021-2 3 5417021-3 4 5417021-4 5 5417021-5 6 5417021-6 7 5417021-7 8 5417021-8 9 5417021-9 10 1-5417021-0 11 1-5417021-1 12 1-5417021-2 13 1-5417021-3 14 1-5417021-4 15 1-5417021-5 16 1-5417021-6 17 1-5417021-7 18 1-5417021-8 19 1-5417021-9 20 2-5417021-0 25 2-5417021-5 Reflectance -65 db 180

FC Attenuators, Build Out FC/UPC Note: Additional s FC Attenuators, Build Out FC/APC (8 ) 1 5209948-1 2 5209948-2 3 5209948-3 4 5209948-4 5 5209948-5 6 5209948-6 7 5209948-7 8 5209948-8 9 5209948-9 10 1-5209948-0 11 1-5209948-1 12 1-5209948-2 13 1-5209948-3 14 1-5209948-4 15 1-5209948-5 16 1-5209948-6 17 1-5209948-7 18 1-5209948-8 19 1-5209948-9 20 2-5209948-0 25 2-5209948-5 1 1754722-1 2 1754722-2 3 1754722-3 4 1754722-4 5 1754722-5 6 1754722-6 10 1-1754722-0 12 1-1754722-2 15 1-1754722-5 18 1-1754722-8 20 2-1754722-0 25 2-1754722-5 Reflectance -65 db 0 9-5209285-9 1 5209285-1 2 5209285-2 3 5209285-3 4 5209285-4 5 5209285-5 6 5209285-6 7 5209285-7 8 5209285-8 9 5209285-9 10 1-5209285-0 11 1-5209285-1 12 1-5209285-2 13 1-5209285-3 14 1-5209285-4 15 1-5209285-5 16 1-5209285-6 17 1-5209285-7 18 1-5209285-8 19 1-5209285-9 20 2-5209285-0 25 2-5209285-5 0 db: 0.50 db max. Attenuators, WDMs, and Switches 6 Note: Additional s 181

ST Attenuators, Build Out ST/UPC 1 5417549-1 2 5417549-2 3 5417549-3 4 5417549-4 5 5417549-5 6 5417549-6 7 5417549-7 8 5417549-8 9 5417549-9 10 1-5417549-0 11 1-5417549-1 12 1-5417549-2 13 1-5417549-3 14 1-5417549-4 15 1-5417549-5 16 1-5417549-6 17 1-5417549-7 18 1-5417549-8 19 1-5417549-9 20 2-5417549-0 25 2-5417549-5 5 db: ±.15 x nominal < 5 db: ± 0.75 db 0 9-5417399-9 1 5417399-1 2 5417399-2 3 5417399-3 4 5417399-4 5 5417399-5 6 5417399-6 7 5417399-7 8 5417399-8 9 5417399-9 10 1-5417399-0 11 1-5417399-1 12 1-5417399-2 13 1-5417399-3 14 1-5417399-4 15 1-5417399-5 16 1-5417399-6 17 1-5417399-7 18 1-5417399-8 19 1-5417399-9 20 2-5417399-0 25 2-5417399-5 0 db: 0.50 db max. D4 Attenuators, Build Out D4/PC 5 5209570-5 10 1-5209570-0 15 1-5209570-5 20 2-5209570-0 5 db: ±.15 x nominal < 5 db: ± 0.75 db Reflectance -45 db Note: Additional s 182

In Line Attenuators Product Facts A range of fixed attenuation values. Standard values of 1 through 20, and 25 db UPC offers Excellent Return Loss Attenuation is wavelength independent and polarization insensitive Low PDL Low modal noise High reliability -60dB Reflectance (unconnectorized) Low cost Vibration resistant Single and Dual Window Designed to comply with Telcordia GR-910 Applications Power leveling in DWDM transmission systems Test and Measurement Power attenuation at the receiver Available Collateral Product Specification 108-2103 Heavy Duty 3mm cable 108-2130 Medium Duty 900µm cable Specifications Attenuation Values 1-20dB and 25 db (Fixed) Reflectance -55 and -60dB for UPC and unterminated respectively Operating Temperature -40 C to +75 C Vibration Resistance < 0.1 x attenuation Tyco Electronics high performance In Line Attenuators utilize a unique all fiber construction to absorb the optical signal. By employing a Tyco Electronics technology, the design minimizes reflectance, attenuation tolerance, and PDL while maximizing reliability, environmental stability, and power handling. There are no filters, air gaps, or core mismatches. Attenuators, WDMs, and Switches 6 Customer Drawings Customizable Features Lead lengths Connectorized types, including SC, FC, ST, & LC LC available in Medium Duty (900 µm cable) only Available in Heavy Duty (3mm cable) and Medium Duty (900 µm cable) 183

In Line Attenuators, Heavy Duty (3mm cable), Fixed Value SC - SC Dual Window In Line Attenuators 1 6588517-1 2 6588517-2 3 6588517-3 4 6588517-4 5 6588517-5 6 6588517-6 7 6588517-7 8 6588517-8 9 6588517-9 10 1-6588517-0 11 1-6588517-1 12 1-6588517-2 13 1-6588517-3 14 1-6588517-4 15 1-6588517-5 16 1-6588517-6 17 1-6588517-7 18 1-6588517-8 19 1-6588517-9 20 2-6588517-0 25 2-6588517-5 In Line Attenuators, Medium Duty (900 µm cable), Fixed Value LC to LC Dual Window In Line Attenuators 1 6588564-1 2 6588564-2 3 6588564-3 4 6588564-4 5 6588564-5 6 6588564-6 7 6588564-7 8 6588564-8 9 6588564-9 10 1-6588564-0 11 1-6588564-1 12 1-6588564-2 13 1-6588564-3 14 1-6588564-4 15 1-6588564-5 16 1-6588564-6 17 1-6588564-7 18 1-6588564-8 19 1-6588564-9 20 2-6588564-0 25 2-6588564-5 184 Reflectance -50 db