HALL D WORKER SAFETY AWARENESS TRAINING (SAF113)

Similar documents
HALL D WORKER SAFETY AWARENESS TRAINING (SAF113)

HALL B WORKER SAFETY AWARENESS TRAINING (SAF111)

HALL B WORKER SAFETY AWARENESS TRAINING (SAF111)

LINDENWOOD UNIVERSITY BASIC EMERGENCY ACTION PLANS

Emergency Preparedness General Response

SCALES NW EMERGENCY ACTION PLAN

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

Emergency Action Plan (EAP)

Emergency Evacuation Plan

EMERGENCY RESPONSE GUIDELINES

Business Emergency Plan

EMERGENCY RESPONSE PLAN

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

Emergency Plan. Chemistry and Chemical Biology. Clark Hall Building 22. Revision 1 January

Emergency Procedures Protocol

Workplace Safety North

Building Emergency Policies and Procedures

BUILDING EMERGENCY ACTION PLAN

IIPP. Injury & Illness Prevention Program Hartog Drive San Jose CA Responsibilities. Workplace Hazards. Training. Incident Investigations

Health and Safety Plans Health and Safety Policy Statement Fire Prevention Plan Objective

Be Safe and Be Prepared! EMERGENCY PREPAREDNESS QUICK-REFERENCE GUIDE. YOUR CURRENT LOCATION Building/Address: Room Number:

Emergency Action Plan Program

HEALTHWEST PROCEDURE. No Prepared by: Effective: February 6, 2008 Revised: June 5, 2017 Environment of Care Committee

BUILDING EMERGENCY ACTION PLAN

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

Building Emergency Policies and Procedures

Emergency Preparedness Guide

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe

Campus Emergency Response Plan Standard Operating Procedure

X0.01 Emergency Management. Approved: September 27, 2002 Revised: July 15, Next Scheduled Review: July 15, 2014 PROCEDURE STATEMENT

Evacuation and Lockdown Plan

Department of Veterinary Medicine

New Worker Orientation Health and Safety

EMERGENCY TELEPHONE NUMBERS

Emergency Action Plan (EAP)

COUNTY OF ALAMEDA County Administrator s Office Risk Management Unit th Street, 3 rd Floor, Oakland, CA 94607

Crisis Response Plan Greenwood Center 207 West Park Avenue Greenwood, MS

Campus Emergency Procedures Guide

Kaufert Laboratory Building Emergency Plan

DIAL 911 EMERGENCY PROCEDURES

Emergency Evacuation Procedures

SAFETY BEGINS WITH YOU!

EMERGENCY RESPONSE/ FIRE PREVENTION

GM Technical Center Emergency Phone Number:

Cerritos College Emergency Procedures (Campus Safety Plan)

Emergency Action Plan

Emergency Action Plan For All City Facilities. Employee Orientation

FIRE PREVENTION PLAN EMERGENCY ACTION

EMERGENCY ACTION PLAN (EAP) UAF

Emergency Procedures Quick Reference Guide

Emergency Action Plan for

Emergency Action Plan

Emergency Action Plan

Xavier Field Office Emergency Action Plan. For. Xavier Field Office Dana Avenue

Dutchess Community College. Emergency Action Plan. Conklin Hall College Residence

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

EMERGENCY ACTION GUIDE

DUNCAN STUDENT CENTER. Emergency Action Plan

TABLE OF CONTENTS. Medical & First Aid Procedure 11, 12. Hazardous Material Emergency Response 17. Civil Disturbances and Demonstrations 21

Emergency Procedures Quick Reference Guide

Occupant Emergency Plan Revised 9/09/2008

Emergency Evacuation or Lockdown

PHOENIX CONVENTION CENTER. EMERGENCY PROCEDURES MANUAL for SHOW MANAGERS

2.1 WHAT TO DO IN THE EVENT OF AN ACCIDENT OR EMERGENCY

Facility Hazard Surveillance of JLab Facilities

West Virginia University Health Sciences Center Campus Emergency Preparedness Instructions for

Sam Houston State University Emergency Protocol Quick Reference Guide

School EMERGENCY PLAN

EMERGENCY PREPAREDNESS: EVACUATIONS

Emergency Action Plan (EAP)

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

Emergency Response Procedures

More information can be found at: Please take note of safety signs and evacuation routes

CAMPUS EMERGENCIES CAMPUS EMERGENCIES WHAT TO DO IN THE EVENT OF A CAMPUS EMERGENCY

Safety Plan. 2/1/2012 Page 1

SECTION 7 EVACUATION PROCEDURES

Men s Shelter SACOT Program 1210 North Tryon Street Charlotte, NC 28206

WESTCHESTER PUBLIC LIBRARY EMERGENCY POLICY. Revised January 12, 2017

Fire Evacuation Plan Bressler Research Building. UMB POLICE or

Neil Armstrong Hall of Engineering. Safety Training

EMERGENCY PROCEDURES LOOK, LISTEN, AND RESPOND

CORPORATE SERVICES HEALTH AND SAFETY

Emergency Action Plan For Alumni Center 1507 Dana Avenue

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

Liberal Arts and Humanities. Building # 275. Emergency Evacuation Plan

Emergency procedures flip book

Emergency Action Plan for Sycamore House 3818 Winding Way

University of Maryland FIRE EVACUATION PLAN

Emergency Action Fire Prevention Plan

GENERAL EMERGENCY AWARENESS

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or

Murray State University Building Coordinator Emergency Procedures. Hollis Franklin College

Fire Evacuation Plan Davidge Hall. UMB POLICE or

South Portland Fire Department Fire Station Emergency Action Plan

Emergency Guidebook WEAPONS ON CAMPUS ACTIVE SHOOTER BOMB THREAT FIRE / EXPLOSION CRIME REPORTING EVACUATION HAZMAT SPILL HIGHWAY HOSTAGE SITUATION

SAFETY BEGINS WITH YOU!

Emergency Response Procedures. Sandhills Community College

Emergency Response Procedures. Sandhills Community College

LYON COLLEGE CRISIS PLAN PROCEDURES

Building Emergency Policies and Procedures. Clermont College 4200 Clermont College Batavia OH 45103

Transcription:

SVN: docs/reviews/experimentalreadinessreview HallD/ERG September 18, 2014 HALL D WORKER SAFETY AWARENESS TRAINING (SAF113) Purpose Familiarize users with safety hazards and protection systems in the Counting House, Hall D and Tagger Hall. Training All users must take the guided walkthrough covering the Hall D Counting House, Hall D and Tagger Hall using the latest update of the Emergency Response Guidelines (ERG) document for the hall. For this, the user should contact the person responsible for the training Hall D/SAF113 - Tom Carstens (867-3940, carstens@jlab.org) or Mark Stevens (310-1576, stevensm@jlab.org) or Elton Smith (269-7625, elton@jlab.org) The guided training will, at a minimum, go over the likely hazards as well as the protection and emergency systems and procedures outlined in Appendix A of the ERG that one finds in the Counting House, personnel access stairs/tunnel, Hall D and the Tagger Hall. The JLab Skill Requirements List (SRL) tracking system (i.e. training) will be used to track the training status. The SAF113 training does not have an expiration date. If however, the conditions of a hall are deemed to have changed sufficiently by the Division Safety Officer, the SAF113 training will be invalidated (forced to expire). The training tracking system will, like with any other training, notify all those affected so that they can make arrangements to take again the guided SAF113 training. SAF113 training is required for unescorted access to the hall and to be able to take shifts in the Counting House. Escorting of shift personnel is not allowed. 1

Contents Emergency Response Guideliness (ERG) for Hall D 1 Introduction 2 2 Purpose and Requirements 2 2.1 Prerequisites to access the halls without escort............. 2 2.2 Reminders................................. 2 3 The two-person rule 3 4 Undergraduate Students in the Experimental Halls 3 A Appendix A 4 A.1 Hazards.................................. 4 A.2 Protection and Emergency systems and procedures.......... 4 1

1 Introduction As part of the Experiment Readiness Review Process and Approval, every experiment is required to submit, in addition to the Conduct-of-Operations (COO), Experiment Safety Assessment Document (ESAD) and, Radiation Safety Assessment Document (RSAD), a document that summarizes the location of major hazards in the hall, the location of the various emergency systems as well as emergency procedures and egress routes during that experiment: the Emergency Response Guidelines (ERG), this document. Shift personnel and anyone else wishing access to the hall during the duration of the experiment, must read and sign to indicate they have understood the COO, ESAD, RSAD and ERG of the experiment. Anyone feeling in doubt with the information contained in the ERG should contact the person responsible for the Hall Worker Awareness Training and schedule guided refresher training. 2 Purpose and Requirements The purpose of this document is to familiarize users with safety hazards and protection systems in the Counting House, Hall D and Tagger Hall. An overview of the layout of the counting house and experimental hall can be found in Fig. 1. It includes a map of the safety equipment and a sketch of the emergency plan for the area. Further details about the Counting House can be found in Fig. 2, details of the experimental hall in Fig. 3 and information about the tagger area in Fig. 4. The list of likely hazards and emergency systems can be found in Appendix A. A summary of emergency response procedures can be found in Fig. 5. 2.1 Prerequisites to access the halls without escort ES&H Orientation (SAF100) Rad Worker I Training (SAF 801C, SAF801T, SAF801P) and been issued a dosimeter by JLab ODH training (SAF103) General Access Radiological Work Permit [RWP] (SAF801kd) Hall D Worker Safety Awareness Training (SAF113) 2.2 Reminders No one under 18 years may enter the Hall No sandals or open toe shoes in the Hall No food or drinking inside the Hall 2

Check postings at the entrance to the hall for special requirements (e.g. long pants may be required during extended shutdowns). If in doubt, please contact the Hall Work Coordinator or his/her designee, Hall D - Tom Carstens Check that all work or test setups follow the work controls indicated in the ESH&Q manual [1] and on the supplemental Physics Division Work Planning Guidance [2]. If in doubt, consult the Safety Warden of the area (T. Carstens, or alternate J. Foyles) in which the work will take place, the Physics Division ESH&Q coordinator (B. Manzlak) or the Physics Division Safety Officer (P. Rossi). 3 The two-person rule Performing work in Hall D may require that personnel work on teams of at least two people. The two-person rule must be followed when performing a task that requires two-persons as indicated by the applicable general JLab safety rules or task OSP/TOSP. Examples of tasks that require two-persons would be operation of the hall crane within 10 ft of the cryogenic transfer lines, safeing-out the high current power supplies, or welding/grinding requiring a fire watch. If in doubt, contact the Hall Work Coordinator or his/her designee. 4 Undergraduate Students in the Experimental Halls Regardless of hall or task, undergraduate students must follow the two-person rule during their first three-months at JLab. During that period, undergraduate students are allowed to work in the hall if (a) their work in the hall is always under the supervision of a hall-authorized buddy (the buddy can not be another undergraduate) and, (b) a permanent JLab staff member is cognizant of the work to be done, has supervisory responsibility for their work and approves of the buddy. As with all work, the work coordinator will be informed of the work. 3

A Appendix A This appendix lists likely hazards, protection and emergency systems used and emergency procedures to be reviewed during the Hall Worker Awareness Training A.1 Hazards Fire (electrical equipment, breaker panels, paper, trash, cables) Tripping and overhead hazards Falling hazards Elevated work High-pressure systems including low-conductivity water distribution Radiation hazards (beam-on, contaminated and activated areas) Loud noise hazards (thin vacuum windows) Flammable gasses (Hydrogen) Cryogenic (ODH and cold-bite ) Magnets and magnetic fields Electrical AC & DC (various voltages) Magnet power supplies and their current distribution systems High-Voltage supplies A.2 Protection and Emergency systems and procedures Signs and postings, Radiological areas Hearing protection requirements Exit signs Exit routes (evacuation plans) Oxygen Deficiency Hazards Personnel Protection Requirements (e.g. earplugs, safety glasses, ) First Aid kit and Emergency Defibrillator 4

Telephone locations with emergency numbers Fire Detection systems (e.g. the Very Early Smoke Detection Apparatus [VESDA]) Alarm pull boxes Fire alarm bells Extinguishers Evacuation routes and muster points Electrical Power shutoff switches Circuit breaker panels Weather related hazards Tornado emergency response Severe weather shelter locations Emergency lights Beam status, interlock and abort Machine State Status Indicators, Magenta/purple beacons, Access doors to hall Key interlocks Run/Safe boxes Oxygen Deficiency Hazard condition detection Sensors locations Blue beacons and alarms locations Radiation Monitors (Controlled Area Radiation Monitors CARMs) RadCon staging areas for equipment to be removed from hall Red beacons for hazards (e.g. energized magnets) Yellow beacons for warning or caution (e.g. energized lasers, forklifts) Cabinets for storing flammable materials 5

Figure 1: Overview of the layout of the Hall D counting house and experimental hall indicating safety equipment and emergency plan. 6

Figure 2: Layout of the Hall D counting house indicating safety equipment and emergency plan. 7

Figure 3: Layout of the Hall D experimental hall indicating safety equipment and emergency plan. 8

Figure 4: Layout of the Hall D tagger hall indicating safety equipment and emergency plan. 9

f a Figure 5: Summary of proper response to various emergency situations. Important information DIAL 9-911 or 911 Emergency Response Procedures Both numbers will connect you to: City of Newport News Emergency Dispatch Center f f a a If dialed from a land-line phone the following are automatically alerted: JLab Security Occupational Medicine Other key JLab Responders. If dialed from a cell phone you will also need to call: JLab Security EVENT ACTION 1 ACTION 2 ACTION 3 Injury or acute illness Call 9-911 or 911 Stay with the victim while awaiting emergency responders Do not move the victim unless they are endangered at location Administer first aid/cpr if willing and trained Avoid contact with other s blood If possible send someone to flag down the ambulance Direct minor injuries to Occupational Medicine (Support Service Center, Bldg 28, Room 22) during regular business hours. Most buildings have one or more first-aid cabinets and AEDs for your convenience. There are pamphlets at these locations to assist you. Fire Alarm Sound Alarm (use the nearest pull box) Evacuate to Muster Point (refer to the evacuation map for your location) Evacuate to Muster Point (refer to the evacuation map for your location) Await All-Clear Notification From Fire Protection Engineer or Building Drill Coordinator before re-entry. Await All-Clear Notification From Fire Protection Engineer or Building Drill Coordinator before reentry. Unexplained Odor of Natural Gas Sound Alarm (use the nearest pull box) Evacuate to Muster Point (refer to the evacuation map for your location) Severe Weather Warning (via weather alert radio, outdoor siren, or other official source) Earthquake Bomb Threat OIL SPILL Do Not Evacuate Building Write Down: Any demands/instructions Caller s number if available Vocal characteristics Any other relevant details to identify the caller Immediately: Pass the Word Taking Cover (refer to the evacuation map for your location) Protect Yourself from Falling Objects (get under a desk or table) or Sound Alarm (use the nearest pull box) Cordon Off Area Keep people away If there are injuries or damage Evacuate to Muster Point (refer to the evacuation map for your location) Wait for trained and equipped staff to control and contain the spill ODH Alarm or visible plume Evacuate to Muster Point (refer to Supervisor s instructions for your location) Call Crew Chief @ 269-7045 Radiation Alarm Hit Push to Safe RED Button Evacuate to Muster Point (refer to the evacuation map for your location) Call Crew Chief @ 269-7045 Automobile Accident Intruders, Threatening or Abusive Behavior other unauthorized conduct Rev. 04/2014 Trouble Indication audible alert in fire alarm panel Requests to Serve Summons or other legal documents Requests for Personal Information about JLab staff or visitors Requests for passwords or other Computer-Access information Requests for JLab News, Status, or other information If anyone is injured. Call 9-911 or 911 Call Facilities Management @ 269-7400 Ensure Your Personal Safety! Run, Hide, Fight (See ES&H Manual Chapter 3510-T5 Active Threat Emergency Procedure and HR Workplace Harassment and Violence Policy) Call Facilities Management @ 269-7400 You are not authorized to provide any information about JLab staff members Refer Requestor to Human Resource Representative @ 269-7068 You are not authorized to provide any information about computer accounts, passwords, user names, and so forth Refer Requestor to Computer Center Help Desk @ 269-7155 You are not authorized to provide any information regarding JLab status or conditions Refer Requestor to JLab Public Information Office @ 269-7689 10

References [1] Jefferson Lab. EH&S manual. http://www.jlab.org/ehs/ehsmanual. 3 [2] Jefferson Lab. Physics Division Work Planning Guidance. http://www.jlab.org/div dept/physics division/work guidance final.pdf. 3 AFTER READING THIS DOCUMENT Employees Make arrangements with Tom Carstens, cell: 757-876-3940 (carstens@jlab.org) or Mark Stevens, cell: 757-310-1576 (stevensm@jlab.org) or Elton Smith, office: 757-269-7625 (elton@jlab.org) to schedule the guided walk-through. Contractors Contact your SOTR to schedule the guided walkthrough. 11