AIR CONDITIONING AIR DOOR RANGE NEW

Similar documents
vortice.com SUMMER VENTILATION NORDIK ECO RANGE Reversible ceiling fans NEW

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE

HYGIENE RANGE HAND DRYERS AND HAIR DRYERS NEW

ELECTRIC HEATING VORTICE

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

VORTICE SUMMER FANS NEW OSCILLATING, WALL-MOUNTED, TABLE, FLOOR AND CEILING FANS PORTABLE AIR CONDITIONERS AND DEHUMIDIFIERS

MANUAL Air curtain WRM06+ WRM08+ WRM10+ WRM12+

VORT PROMETEO PLUS HR400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING

VORT NRG RANGE COMMERCIAL VENTILATION NEW

Controlled mechanical ventilation GB 03

Maxwell Air Curtains A I R C U R T A I N S

Co153, Co154 SECURITY SHUTTERS RC3 GRADE ANTI-BURGLARY CERTIFICATION UNI EN1627 P6B GRADE ANTI-BURGLARY CERTIFICATION UNI EN356

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

Maxwell Air Curtains A I R C U R T A I N S

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING

GAS AIR HEATER RANGE

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Topvex SR03, SR04, SR06 Compact Air Handling Unit

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

HARTFORD SLIM ASSEMBLY INSTRUCTIONS. IMPORTANT - RETAIN FOR FUTURE REFERENCE - READ CAREFULLY.

CLEAN AND CONDITIONED AIR ARIA PULITA E CONDIZIONATA

Halton - Meeting the Kitchen Ventilation challenges of multiple venues in Hotels, Casinos and Resorts

Co170 ARMOURED WALL BURGLAR PROOF GRADE 2 ACCORDING TO UNI EN1143

Operating Instructions Air Conditioner

Thermozone ADR 200/300 E/W

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Halton MobiChef Unleashed Business Opportunities! INNOVATION 2014 Patent Pending

60cm Chimney Extractor

Using the Remote Control Unit

USER S GUIDE WATER HEATED AIR CURTAINS

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

TEVHR. Heat Recovery Ventilator

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

XS1271 XS1872 INSTRUCTION MANUAL MODE D EMPLOI This air conditioner uses the new refrigerant R410A.

BT16.4SS-HK BT19.4SS-HK Cooker Hood

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

AIR CURTAIN GUIDE WHAT IS AN AIR CURTAIN?

Centrifugal Juicer # 50 "Santos Juicer"

TUNNEL FANS STANDARD AND HOT SMOKE

Infrared Portable Space Heater

HRV Enthalpy. Catalogue

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

PORTABLE AIR CONDITIONER (LOCAL)

TEVHR. Heat Recovery Ventilators

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Infrared Portable Space Heater

BFR6 / BFR9 Rangehood

NEW RANGE OF WARM AIR CURTAINS

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

WHHR Midi & Midi Lite

DOORS P -SERIES. Shop & Business MADE OFAIR. The smart way for Shop & Business TEDDINGTON AIR CURTAIN SYSTEMS FILTERLESS OPERATION

Air curtain.

AIR DESIGN WATER ITALIA CARISMA COLLECTION

TEVHR. Heat Recovery Ventilators

instructions for use Air Purifier with ionizer _00/

TTL Products Exclusiv. TTL-TWISTO Design air curtain systems with energy saving effect and with EC-fan technology

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

OPERATING INSTRUCTIONS

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Digitemp. Beyond air conditioning.

Enriching Environments

Conditioning your ambient, maximising your comfort.

Airdoor Fundamentals and Applications

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

R A N G E C O N C E P T

WA & RA EVAPORATIVEE COOLERS INSTRUCTION MANUAL

Industrial Air Heaters

Sensors (All Fully Customisable)

HEATER. Fan Forced IMPORTANT INSTRUCTIONS READ & SAVE OWNER S MANUAL. Model No.: DR W 120V 60Hz DR W 240V 60Hz

WATER IS ESSENTIAL FOR OUR LIFE.

Instruction Manual WARNINGS

HUMIDITY-SENSITIVE SOLAR VENTILATION. The sun gives you a breath of fresh air

TDS 100. EN Operating Manual Electrical Fan Heater

BL 53 Security Barrier ENGINEERING SPECIFICATIONS

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Ventilation and Hand Dryers

GUH90 90 cm Canopy Hood

Conditioning your ambient, maximising your comfort.

Features. Simple One-touch Wireless Remote Control The remote control unit has several features to facilitate automatic operation.

OPERATING INSTRUCTIONS

Santoemma Professional Cleaning Machines

Evaporative Cooler 10 litre

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Technical Information

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

XHS1271 XHS1872. This air conditioner uses the new refrigerant R410A. COOL/DRY/HEAT Model

with plasma ioniser and Remote Control USER MANUAL

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Air Conditioning Refrigeration Electrical Work TEL: 0(204) (254)

Pedestrian Swing and sliding doors. Accessories

PORTABLE AIR CONDITIONER (LOCAL)

FIRE PROTECTION FIRE DAMPERS ISONE+

Superdryer Dehumidifiers

Transcription:

www.vortice.com AIR CONDITIONING AIR DOOR RANGE NEW

www.vortice.com

HEADQUARTERS VORTICE IN THE WORLD Founded in 1974, Vortice France is located at Crétail about 10 Km from Paris. Our current Vortice Headquarters have been located in Tribiano (Milan) since 1972. Vortice main company s philosopy is the concept that air is our life. Our mission is always to provide effective solutions for improved air quality using the latest technology to develop and manufacture effective products worldwide. Founded in 1977, Vortice Limited is located at Burton on Trent in the East Midlands. Vortice has achieved European market leadership by dedicating their efforts to the production of products for ventilation, climate control, heating, extraction, purification and the treatment of air, for domestic, commercial and industrial applications. Since 1954 Vortice has been synonymous with quality and excellence and continues to make significant improvements by investing in continuous research to improve the efficiency and quality of its products. Founded in 2012, Vortice Ventilation System is located about 200 Km from Shanghai. Founded in 2012, Vortice Latam in San Josè Costarica. 3

AIR DOOR RANGE Air curtains for horizontal installation, particularly suitable for use in public places Elegant design and environmental comfort Air curtains, installed in line with doors or openings in general, create an invisible barrier separating zones of different temperatures, preventing cooled air from escaping in summer and warm heated air in winter, in order to stop heat from being transferred from one environment to another while preventing pollutants (e.g., dust, exhaust gases, smoke, odours) and insects coming in from outdoors. The air curtains allow customers to enter and leave freely, without obstructing the passageway and providing maximum visibility into the room. The barriers can also be used inside the building, to separate rooms with different conditions: for example, heated areas and unheated warehouses, or dining rooms and kitchens; this facilitates the transit of staff and prevents odours and vapours from being transferred. Key features Elegant and distinctive aesthetics. High performance (up to 2,700 m 3 /h). High speed of air flow (11 m/s standard models, 9,5 m/s. models equipped with heating elements), granting an effective action up to 4 m high installation. Great installation flexibility: front intake grilles allow AIR DOOR mounting close to the ceiling even in low ceiling rooms (minimum 2,30 m). Easy and quick installation, thanks to the practical wall mounting bracket. Possibility on installation in series, to cover long width openings. 4

AIR DOOR RANGE Installation Air speed Minimum installation height: 2.3 m. Maximum recommended installation height: 4 m. Horizontal wall installation, above doors or as close as possible to the opening, to prevent the passage of air at the sides. There is no need to leave space between the curtain and the ceiling, as models with a front air intake grille do not require this. These curtains can also be used for installations with limited space. Easy to install by means of a practical wall mounting bracket. 8-11.5 m/s 4-5 m/s 0 m 1 m YES NO YES NO 3-4.5 m/s 2 m min 2.3 m max 4 m over 4 m 2-3.5 m/s 3 m 4 m Application types Food industry, where climatic and hygienic separation is required between departments, alongside the quick and easy passage of goods and people; Hospitals and laboratories; Catering and hospitality (kitchen odours are kept away from dining rooms); Offices, schools; Cinemas, bookshops; Warehouses and manufacturing departments; Bars, restaurants, ice cream parlours; Supermarkets; Banks; Swimming pools, sports centres, changing rooms; Refrigerated units (outdoor mounting); Greenhouses, drying rooms. 5

AIR CONDITIONING AIR DOOR RANGE Air curtains for horizontal installation, particularly suitable for use in public places PRODUCT SPECIFICATIONS Provide appreciable cost savings related to heating (in winter) and cooling (in summer). Installed in correspondence of doors and, more generally, of access areas, AIR DOOR units generate an air stream hindering the entry of external air at unpleasent temperature. Particularly suitable also to prevent entry of smoke, smog, insects and avoid spread of odors between adjoining rooms. 8 models for different lengths (900 mm, 1200 mm, 1500 mm and 2000), power supplies (single or three phase), available features and benefits paid. Cross-flow fans, ensuring low noise levels, driven by asynchronous, double-shaft, two speed motors for the best compromise between performance, temperature of generated air flow (models equipped with heating elements), and output sound level. Front panels in brushed aluminum (silver grey color), integrating intake grille; rear panels in black painted sheet metal; side panels in black thermoplastic resin. Adjustable flaps; mounted in correspondence of exhaust, allow to direct outgoing airstream as desired. Infrared remote control allowing: - ON/Off switching - Selection of desired operation speed - Heating elements switch On/Off (AIR DOOR H models only) Commands are replicated on board. A lamp on the front panel shows the product status. Only for models AIR DOOR H, heating elements consisting of PTC thermistors offering high thermal performance and reduced drag, protected against overheating and voltage peaks. A peculiar logic of operation, delaying the fan stop after the battery switch off, contributes to its reliable operation over time. Possibility of coupling with standard door sensors on the market. Insulation class: I.. Infrared remote control Commands are replicated on board 6

AIR DOOR RANGE TECHNICAL DATA Models Code V Hz Fan Power min./max. W Heating Power min./mid./max. kw Airflow min./max m 3 /h Air Speed min./max. m/s Noise min./max. db Kg AIR DOOR AD 900 65195 110/160-1100/1400 55/57 10 AIR DOOR AD 1200 65196 150/200-1600/1900 56/58 12.5 9/11 AIR DOOR AD 1500 65197 230 180/230-2000/2500 57/59 15.5 AIR DOOR AD 2000 65198 300/350-2900/3600 59/61 20.5 50 AIR DOOR H AD 900 M 65155 110/160 2/4/6 1000/1200 55/57 13.5 AIR DOOR H AD 900 T 65156 110/160 2/4/6 1000/1200 55/57 13.5 8,5/9,5 AIR DOOR H AD 1200 T 65157 380 150/200 4/6/8 1500/1700 56/58 16 AIR DOOR AD H 1500 T 65158 180/230 6/8/10 1900/2200 57/59 18.5 DIMENSIONS C A B Models A B C AIR DOOR AD 900 900 AIR DOOR AD 1200 1200 AIR DOOR AD 1500 1500 220 190 AIR DOOR AD 2000 2000 AIR DOOR H AD 900 M 950 AIR DOOR H AD 900 T 950 AIR DOOR H AD 1200 T 1230 305 235 AIR DOOR H AD 1500 T 1510 Dimensions (mm) 7

Cod. 5.170.084.666 07/15 Vortice Elettrosociali S.p.A Strada Cerca, 2 Frazione di Zoate 20067 Tribiano (Milano) Conforms to the standards: EN 60335-1, EN 60335-2-80, EN 60529, EN 62233 Performance Tel. checked (+39) 02 906991 according Tél. to: (+33) CEI 1.55.12.50.00 107-53/1986 Tel. (EN13-4: (+44) 1283-49.29.49 2004) Fax (+39) 02 90699314 Fax (+33) 1.55.12.50.01 Fax (+44) 1283-54.41.21 EMC: EN 55014 1, EN 55014-2, EN 61000-3-2, EN 60555-1 Italia France United Kingdom European Directives for CE mark: Low Voltage Directive (2006/95/CE) www.vortice.com www.vortice-france.com www.vortice.ltd.uk Directive on Electromagnetic Compatibility: (2004/108/CE) export@vortice-italy.com Vortice France 15-33, Rue Le Corbusier CS 30007 94046 Créteil Cedex contact@vortice-france.com Vortice Limited Beeches House-Eastern Avenue Burton on Trent DE13 0BB sales@vortice.ltd.uk The description and illustrations in this catalogue are understood to be indicative and are not binding. Vortice reserves the right, while not changing the essential characteristcs of the models described and illustred, to modify products whenever necessary and without warning.