Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Similar documents
Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

GHE Dehumidifiers for radiant cooling systems with heat recovery

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

PRODUCT GUIDE

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Conditioning your ambient, maximising your comfort.

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

ELFOEnergy Duct Inverter

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

YORK Close Control units

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

DOMESTIC DEHUMIDIFIERS FLIPPERDRY

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

w w w. h i d e w. i t i n f h i d e w. i t CCV air conditioner for cellars I N S T A L L A T I O N, U S E A N D M A I N T E N A N C E M A N U A L

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

G E N E R A L C ATA L O G Dehumidif ers

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

K Series Modular air conditioners. With direct expansion coil With chilled water coil

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

TECNAIR LV C series Close control air conditioners

YORK YC-P Series Close Control Air Conditioners

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Precision air handling cabinets Ciatronic MICRO/EXPAIR

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Blue Box Epsilon Echos +

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

USER AND MAINTENANCE MANUAL

CRIMSON & CRIMSON MAX

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Travaglini EQUIPMENT FOR FERMENTING AND AGING OF SALAMI. Travaglini_inglese.indd 6 05/07/

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

Fan Coil Range HYDRONIC TERMINALS

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

CHAPTER 6 CONDENSING UNITS

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

TECNAIR LV C series Close control air conditioners

gforce Units Data Aire and Data Temp Series

Gemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

RECUPERA DRY Controlled mechanical ventilation with dehumidification and air treatment GB 01. Air conditioning. Ideas to install

OPERATING RELIABILITY AND CONTINUITY. HIGH SENSIBLE COOLING CAPACITY No latent cooling required.

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Energy Recovery with Cooling and Heating Model ERCH

DATATECH. Precision air conditioners for technological environments 6 220

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Roof top SPACE RPC 450Z R407C M011

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

Air magic NTD500 Neutral Temperature Dehumidifier Air magic HRV500 Heat Recovery Ventilation. designed for radiant cooling systems.

Close control air conditioning

Liquid Desiccant Air Conditioning Systems

HYDRONIC RESIDENTIAL

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Precision air conditioners with inverter technology for stable room conditions

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

CDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

DEMAND-CONTROLLED HOME VENTILATION

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

Dehumidifying with Dedicated Outdoor Air

Blower-YEFB-020-3R-1maxVel

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

FH - GH Dehumidifiers for radiant cooling systems

Hi-Pres Cooling Products Catalogue. Product Catalogue

Transcription:

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems, industrial processes, public swimming pools and highperformance heat recovery systems for the residential Controlled Mechanical Ventilation. Every HiDew dehumidifier and recovery system has been designed to respond to an increasingly demanding market in terms of technology, reliability, design, compactness, efficiency, sound level, simplicity and installation ease. A wide range of accessories (optional) can fulfil any request and, in the event that installation is especially difficult, HiDew technicians are available to suggest and provide customised solutions. QUALITY FOR YOUR WELLBEING

Dehumidifiers for horizontal drop ceiling radiant systems Dehumidifiers for fitted vertical radiant systems Dehumidifiers for radiant systems with heat recovery Horizontal heat recovery systems with electronic fans Horizontal heat recovery for centralized systems Vertical heat recovery systems with electronic fans Mechanically controlled ventilation Design dehumidifiers for small swimming pools Ductable dehumidifiers for small swimming pools Air conditioners for cellars Dehumidifiers for industrial processes Dehumidifiers for swimming pools Dehumidifiers for swimming pools with high air renewal RSO RSV RER ROE ROC RVE VMC DDS DCS CCV ID SP SPR P. 4 P. 5 P. 6 P. 8 P. 8 P. 8 P. 10 P. 12 P. 12 P. 14 P. 16 P. 16 P. 18

Expert nano Stand-by Set RSO RSE DEHUMIDIFIERS FOR HORIZONTAL DROP CEILING RADIANT SYSTEMS R-134a OZONE FRIENDLY DEHUMIDIFICATION COOLING HEATING ISOTHERMIC RS485 PROTOCOL CONNECTION LINK 530 240 600 The fitted vertical dehumidifiers of the RSV range and the horizontal ductable dehumidifiers for drop ceilings of the RSO / RSE range are designed for civil, residential and commercial environments with high latent load that require 24hrs/day operation. These are particularly suitable for buildings cooled by radiant systems, such as flooring, walls or ceiling. HiDew dehumidifiers can be connected and monitored with RS485 serial port. The RS range consists of two versions : A I A = Neutral air version (isothermal): The letter A represents the neutral air isothermal dehumidifier with air condensation, which is supplied with pre and post cooling coils as standard. The outlet air is the same temperature as the inlet air. I = Cold integration version: The letter I represents the dehumidifier that can add cold power to the radiant system. Thanks to a brazed plate condenser, the I models cool the air when required, just as a normal air-conditioner. This function is particularly useful, during half seasons, due to the high difference in temperature, or when cooking or when guests arrive. The I models must always receive water from the radiant system in order to operate. Technical sheet of the range RS RSO 020 A RSO 020 I RSV 020 A RSV 020 I RSE 050 A RSE 050 I Dehumidifying capacity L / day 20 20 20 20 48 48 Air flow rate m 3 /h 250 250 250 250 600 600 Cooling Power Watt isothermal 1240 isothermal 1240 isothermal 3360 Sound level db(a) 38 38 38 38 42 42 Power supply V/ph/Hz I-------------------------------------------- 230/1/50 ----------------------------------------------I Dimensions L X D X H mm I---- 530 X 600 X 242 ----I I---- 480 X 220 X 665 ----I I---- 760 X 650 X 350 ----I All the values refer to the following conditions: Air temperature 26 C, Relative humidity 65%, Water temperature 15 C 4

Expert nano Stand-by Set DEHUMIDIFIERS FOR FITTED VERTICAL RADIANT SYSTEMS RSV 219 480 665 R-134a OZONE FRIENDLY DEHUMIDIFICATION COOLING HEATING ISOTHERMIC RS485 PROTOCOL CONNECTION LINK Options: - Formwork - White lacquered wooden panel - Painted steel sheet panel with plastic grills - Supply plenum - Mechanical humidistat - RS485 serial port - Supply flange - Steel case for the out-of-the-wall installation - Wooden case for the out-of-the-wall installation - Painted steel sheet panel with aluminium grilles - 2-steps mechanical humidistat - Regulation for floor hot / cold / humidity 5

RER RADIANT SYSTEMS DEHUMIDIFIERS WITH AIR RENEWAL AND HIGH-EFFICIENCY HEAT RECOVERY SYSTEM R-134a RS485 PROTOCOL HEAT RECOVERY VARIABLE SPEED OZONE FRIENDLY DEHUMIDIFICATION COOLING HEATING ISOTHERMIC AIR FILTERS CONNECTION LINK The RER range dehumidifiers with high-efficiency heat recovery system are used in radiant cooling buildings together with an air renewal system. The RER dehumidifiers dehumidify, cool, heat and change the air. They recover heat from expelled air. High pressure and minimum electric consumptions are guaranteed by the adjustable electronic fans with permanent magnet brushless motor and cutting-edge incorporated inverter. The top-quality refrigeration, hydraulic, aerolic and electrical components make RER units state of the art dehumidifiers in terms of efficiency, reliability and silence. More than 90% yield is guaranteed by the high-efficiency counter-current heat recovery system. The zero to 130/250 m3/h modulating air renewal can be manual or automatic. The humidifier autonomously controls room temperature and humidity through the standard fitted temperature and humidity sensors. The RER dehumidifiers can be connected to a home automation system thanks to the standard supplied RS485 serial port and requested software customisation. RER 020 RER 050 Technical sheet of the range RER W A I W A I Dehumidifying capacity L / 24h 29 24,5 24,5 58 48 48 Air flow rate m 3 /h 260 260 260 520 520 520 Air renewal m 3 /h 0-130 0-130 0-130 0-250 0-250 0-250 Recovery system yield % I--------------------------------------------- > 90% -------- -------------------------------------I Cooling Power Watt 1920 isothermal 1300 3650 isothermal 3230 Sound level db(a) 38 39 39 43 44 44 Power supply V/ph/Hz I----------------------------------------- 230/ 1~+ N /50 -------------------------------------------I Dimensions L X D X H mm 1005 X 680 X 250 I------- 1125 X 680 X 250 -----I I--------------- 1665 X 760 X 375 --------------I All the values refer to the following conditions: Air temperature 26 C, Relative Humidity 65%, W Version Water temperature 15 C : water at 10 C 6

The RER range consists of 3 versions : A I - W A = Neutral air version (isothermal): The letter A represents a neutral air isothermal dehumidifier with air condensation, which is supplied as standard with pre and post cooling coils. The outlet air has the same temperature as the inlet air. I = Cold integration version: The letter I represents a dehumidifier that can add cold power to the radiant system. Thanks to the presence of a brazed plate condenser, the I models cool the air as a normal air-conditioner, when required. This function is particularly useful, during half seasons, due to the high difference in temperature or when cooking or when gusts arrive. In order to operate, the I models must always receive water from the radiant system. W = Water version: The letter W identifies an especially silent chilled water hydronic dehumidifier without compressor. The outlet air is always cooler than the inlet air. The W version supplies conditioned air in summer and heating in winter. Summer functions Renewal Renewal + dehumidification Renewal + dehumidification + cooling Cooling Dehumidification Dehumidification + Cooling 4 1 2 3 15 14 13 10 9 8 7 6 5 1 Fresh air intake 2 Exhaust air intake 3 Room air intake (for recirculation) 4 Exhaust air discharge 5 Room air supply 6 Heat exchange coil 7 Blower fan 8 Compressor 9 Exhaust fan 10 Heat recovery system 11 Recirculation damper 12 Supply air filter 13 Recovery system air filter 14 Outdoor air filter 15 Outdoor air damper 15 11 12 9 8 4 Winter functions Renewal Renewal + heating Heating 1 2 3 14 13 7 6 5 11 12 Options: Included: - Remote user terminal - Supply plenum - Recovery plenum - Outside air dampers for dew-point control - Dirty filters indicator pressure switch - Set high efficiency air filters - Antifreeze thermostat - Air distribution systems: see VMC chapter - RS485 serial port - Temperature and humidity probes 7

ROE HEAT RECOVERY SYSTEMS ROC RVE RS485 PROTOCOL HEAT RECOVERY FREE COOLING VARIABLE SPEED AIR FILTERS CONNECTION LINK Air quality and purity, temperature and humidity are critical for comfort, especially during the winter when opening the windows for air results in a significant loss of heat and discomfort for the occupants. In this case a system of controlled mechanical ventilation is the best solution to maintain both the levels of energy performance and the quality of the indoor air. Recent regulations on energy saving in buildings combined with increasingly efficient thermal insulation and ever-better fitting of doors and windows, have definitely made our homes more comfortable both thermally and acoustically. This, however, has also transformed them into potential hazardous, sealed traps where pollutants used in the production process (such as formaldehyde) can be spontaneous released. To achieve adequate air renewal in the building and to ensure good indoor air quality, it is essential to install a controlled mechanical ventilation system. Air renewal is essential for clean living air. The European Parliament has legislated on this, citing ventilation as a need for the building. This need can clash with the need to improve the building s energy performance to reduce consumption to a minimum. Controlled mechanical ventilation with ROE, RVE and ROC of HiDew heat recovery is the best solution to reduce the energy needs of a building and at the same time improve the healthiness of the spaces. ROE RVE ROC Technical sheet of the range ROE, RVE, ROC 10 20 35 50 35 50 10 20 Nominal air flow rate m 3 /h 100 200 350 500 350 500 100 200 Efficiency % 93 91 90 88 90 88 93 93 Recovered heating power in winter Watt 790 1547 2660 3732 2660 3732 790 1580 Recovered heating power in summer Watt 270 538 920 1280 920 1280 270 540 Rated power consumption Watt 21 40 75 85 75 85 -- -- Power supply V/ph/Hz I ------------------------------ 230/1/50 ------------------------------- I Available static pressure maximum speed Pa 150 160 150 160 150 160 -- -- Load losses Pa -- -- -- -- -- -- 110 110 Air connections diameter mm 4x125 4x160 4x180 4x180 4x180 4x180 4x125 4x160 The recovered heat power and yield values are stated in the indoor air 20 /50%rh and outdoor air -5 /80%rh points 8

STANDARD CONTROL DEVELOPMENT CONTROL Electronic fans with brushless motor and built-in inverter STANDARD STANDARD Correct fan rotation control STANDARD STANDARD Intelligent automatic defrost STANDARD STANDARD 3 speed setting STANDARD -- Multi-speed setting -- STANDARD Timed dirty filters signalling STANDARD STANDARD General fault signalling STANDARD -- Detailed fault signalling -- STANDARD Graphic adjustment display to be placed on the wall -- STANDARD Boost mode -- STANDARD Programming by time bands -- STANDARD RS485 serial port -- OPTIONAL Free-cooling OPTIONAL OPTIONAL Dirty filters pressure switch -- OPTIONAL Humidity sensor -- OPTIONAL CO2 sensor -- OPTIONAL VOC sensor -- OPTIONAL Air purifier -- OPTIONAL Coil water duct OPTIONAL OPTIONAL Supply temperature control kit -- OPTIONAL High-efficiency air filtering set OPTIONAL OPTIONAL Air supply at constant flow -- OPTIONAL Air supply at constant pressure -- OPTIONAL THE HEAT RECOVERY SYSTEMS: Increase efficiency class and property value Renew air without dispersing heat Reduce danger of allergies Sample of standard control (not supplied) 9

VMC MECHANICALLY CONTROLLED VENTILATION The new Series of VMC accessories for air distribution, to be combined with the units of our RS, RER and ROE / ROC / RVE Series. Thanks to the variety and completeness of this line, it is possible to realize the ideal comfort conditions and to give an optimal response to the needs for the different installations and canalizations of the units. Our supply and recovery plenums, the coils for ducted installations and the grilles, combined with our machines, grant the realization of flexible, complete and customizable systems for the air distribution, capable of satisfying the needs of each single ambient. The installation of HiDew VMC accessories is a child s play! 10

Accessories Supply and recover air galvanized steel plenums with internal thermal insulation and sound absorber, with circular connections. Supply and recover air galvanized steel plenums with internal thermal insulation and sound absorber, to be combined with design grilles. All our plenums are equipped with an exclusive system of air flow calibration, to grant the right value of air renewal. Conical supply plenum in galvanized steel with internal thermal insulation and sound absorber (for RER models). Hot / cold water coil ducted with galvanized steel plenum, internal insulation, sound absorber and steel basin for condensation collection. Supply and recover grilles with high design, available in aluminium or glared steel. Flange for the connection of flexible pipes in / out air renewal. Ventilation valve for the air recover with adjustable jet. Flexible pipe diameters mm. 125 / 160 / 180 / 200. Polyethylene pipes for the canalization and distribution of air, to be combined with supply and recover plenums. 11

DDS DCS DESIGN WALL-MOUNTED DEHUMIDIFIERS FOR SMALL SWIMMING POOLS HEATING R-410A OZONE FRIENDLY DEHUMIDIFICATION RS485 PROTOCOL CONNECTION LINK LOW NOISE SCROLL COMP. DDS and DCS series dehumidifiers with advanced control are completely autonomous and are conceived for wall-mounted installation in small private swimming pools. DDS models are thought to be installed directly in the room to be dehumidified and the pleasant design is suitable also for other ambiences, such as museum, archives, libraries, churches, cellars and basements. The sober but elegant look eases the installation in public and private ambiences, generally characterized by a sophisticated design. DCS models are thought for the installation in a technical room adjacent to the ambience to dehumidify: in this case, the installation requires supply and recover grilles. The series consists of 10 models, from 46 up to 226 L/day. DDS and DCS dehumidifiers are completely autonomous in managing humidity: the control on board reads the ambient humidity and activates the dehumidification process when necessary: finally, the installation of these units is particularly simple. 12

2 2 Supply plenum DDS DCS 1 1 Recovery plenum DDS - DCS Technical sheet of the range 040 050 060 070 090 100 160 190 210 230 Dehumidifying capacity (at 30 C / 80% R.H.) L/day 46 52 61 68 89 98 165 186 211 226 Nominal air flow m3/h 350 450 500 600 700 800 1000 1200 1500 1500 Hot water coil capacity (1) kw 3,7 4,5 4,5 6,1 6,8 7,5 10,1 11,5 14,5 14,5 Load losses water without valve kpa 8 11 11 25 30 36 14 18 32 32 Load losses water with valve kpa 11 16 16 35 42 50 24 31 52 52 Electrical heater capacity kw 1,5 1,5 1,5 2 3,6 3,6 4 4 7,2 7,2 Power consumption kw 0,9 0,9 1 1 1,7 1,7 2,6 2,7 3,6 3,9 Dimensions L x H x D mm I------- 850 x 780 x 280 ---------I-------- 1050 x 780 x 280 -------I--- 1350 x 850 x 330 -I- 1550 x 850 x 330 -I Refrigerant gas R410A Power supply V/ph/Hz I-------------------------------------- 230 / 1 / 50 ----------------------------------------I-- 400 / 3+N / 50 --I Working temperature range C 12-36 Working humidity range % R.H. 45-95 (1) Hot water coil capacity declared at the following conditions: water T 80 C, ambient T 30 C. Options: - Advanced control - Advance remote display - Hot water coil - Electrical heaters for air - Hot water coil with 3-ways valve - Silent version - Serial board RS485 for Modbus communication (only combined with the advanced control) - Mechanical hygrostat on board (only combined with the standard control) - Remote mechanical hygrostat - Chrono thermo hygrostat - Supply and recovery plenum (only for DCS models) - Supply and recovery grilles (only for DCS models) 13

CCV AIR CONDITIONER FOR CELLARS The new CCV air conditioner is studied and developed to grant a fine control of temperature and humidity parameters, especially for small private cellars and other ambiences that need such a fine parameters control. The compact and elegant design of the unit can satisfy the most exigent requests according to reduced spaces, as often is the case for the ambiences of destination. The unit is a mono-block direct expansion solution with a high technology degree. Functions: Heating Cooling Humidification Dehumidification HEATING COOLING R-410A RS485 PROTOCOL OZONE FRIENDLY DEHUMIDIFICATION CONNECTION LINK LOW NOISE Focus on technology: - Electrical heating - Refrigerant cooling circuit - Humidification with distilled water tank - Recirculation fan: electronic radial with brushless engine and inverter, that can be modulated from 0 up to 100% - Condensation fan: electronic radial with brushless engine and inverter, that can be modulated from 0 up to 100% - Temperature and humidity probe on board with close tolerance (+/- 0,5 C/%) - Advanced and programmable control with available remote display - Water sanitization system - Time-bands program - Access and unit maintenance from the front Advantages: - Mono-block extremely compact unit - Elegant design - Connection with the aeraulic system compatible with the new HiDew VMC Series for air distribution - Short installation time - No needs for refrigerator technician neither for refrigerant gas empty or fill in operations - The risk of installation faults is extremely reduced: higher economy - Circular connections nr 6 x 160 mm 14

Technical sheet CCV 450 S CCV 450 H Cooling power (*) Watt 1750 2150 Recirculation internal air flow m³/h 450 450 Condensation external air flow m³/h Modulated from 0 to 450 Modulated from 0 to 450 Recirculation fan pressure Pa 180 180 External air fan pressure Pa 150 150 Electrical heater capacity Watt 1600 1600 Nominal power consumption Watt 890 910 Maximum power consumption Watt 1240 1260 Maximum power consumption with electrical heater Watt 2840 2860 Dimensions L x H x D mm 650 x 1645 x 450 650 x 1645 x 450 Refrigerant gas R 134 A R 410 A Power supply V/ph/Hz 230 / 1 / 50 230 / 1 / 50 Internal temperature working range C da 10 a 28 da 10 a 25 External temperature working range C da -5 + 37 da -5 + 35 Internal humidity working range %u.r. 45-95 45-95 (*) internal conditions 18 C / 80% R.H, - external air 30 C Options: - Humidification system - Humidification water sanitization system - Electrical heater - RS485 Serial board - Remote user terminal - Silent version - Wood-like cover 15

ID SP DEHUMIDIFIERS FOR SWIMMING POOLS AND INDUSTRY HEATING R-410A RS485 PROTOCOL OZONE FRIENDLY SCROLL COMP. ENERGY SAVING VARIABLE SPEED DEHUMIDIFICATION AIR FILTERS CONNECTION LINK The ID and SP range dehumidifiers are designed for use in high latent load environments requiring 24hrs/day operation. They are typically installed in environments such as public and private swimming pools, dairies, basements, ironing shops, curing cellars, warehouses and wherever a lack of humidity control can damage the structure or the product. Technical sheet of the range 0130 0160 0190 0210 0260 0300 0350 0450 0580 Dehumidifying capacity L / day 128 157 190 210 268 302 358 452 581 Air flow rate m 3 /h 1200 1600 1600 2000 2800 2800 3800 4000 4800 Hot water coil capacity kw 9,8 9,8 9,8 16,5 17 17 26,5 26,5 27 Power supply V/ph/Hz I------- 230/1/50 ----------I I--------------------- 400/3/50 ------------------------------I Dimensions L X D X H mm I---- 700 X 550 X 900 -------I I------- 700 X 850 X 900 ------I I----- 830 X 850 X 1350 -----I Technical sheet of the range 0750 0950 1100 1400 1500 1700 1900 2200 3000 Dehumidifying capacity L / day 760 955 1120 1380 1480 1710 1870 2180 2960 Air flow rate m 3 /h 7000 8200 11000 12500 13000 15000 15000 17000 25000 Hot water coil capacity kw 48 55 76 83 98 107 107 118 168 Power supply V/ph/Hz I--------------------------------------- 400/3/50 ------------------------------------------I Dimensions L X D X H mm 1000 X 1400 X 1350 -I- 1000 X 1950 X 1640 -I----------- 1000 X 2500 X 1640 ---------I 1000 X 3390 X 1640 All the values refer to the following conditions: Air temperature 30 C, Relative Humidity 80%, Water temperature 80/70 C 16

2 1 Recirculation air fan 2 Compressor 3 Evaporator coil 4 Condenser coil 5 Post heating coil (optional) 1 1 2 3 4 5 STANDARD CONTROL DEVELOPMENT CONTROL Electronic radial fans -- OPTIONAL ACF: automatic control flow -- OPTIONAL High pressure centrifugal fans OPTIONAL OPTIONAL Hot water reheat coil with valve OPTIONAL OPTIONAL Desuperheater OPTIONAL OPTIONAL Dirty filters sensor OPTIONAL OPTIONAL Softstart OPTIONAL OPTIONAL RS485 serial port OPTIONAL OPTIONAL Filter holder frame for suction ducting OPTIONAL OPTIONAL EU4 Efficiency air filters OPTIONAL OPTIONAL Condensate drain pump OPTIONAL OPTIONAL Clock card - time bands -- OPTIONAL Humidity sensor -- OPTIONAL Mechanical humidistat OPTIONAL -- CTI - Chrono-hygrothermostat OPTIONAL -- Fresh air damper OPTIONAL OPTIONAL Hot gas defrosting OPTIONAL OPTIONAL CO2 or VOC sensor -- OPTIONAL Electric coils OPTIONAL OPTIONAL Remote wall terminal -- OPTIONAL Outdoor version OPTIONAL OPTIONAL Manometers OPTIONAL OPTIONAL Summer / Winter operating modes -- OPTIONAL 17

SPR SWIMMING POOL DEHUMIDIFIERS WITH ENHANCED AIR RENEWAL AND HIGH-EFFICIENCY HEAT RECOVERY SYSTEM R-410A RS485 PROTOCOL HEAT RECOVERY HEATING OZONE FRIENDLY SCROLL COMP. VARIABLE SPEED DEHUMIDIFICATION AIR FILTERS CONNECTION LINK The SPR units are ideal for swimming pools that not only require dehumidification but must also renew the indoor air without dispersing heat outdoors. Up to 80% yield is guaranteed by the high-efficiency recovery system. The SPR units represent the state-of-the-art in terms of efficiency, reliability and emitted sound power. The SPR range only uses electronic radial fans with high-energy efficiency incorporated inverter. HiDew has developed a sophisticated adjustment software to adjust the SPR dehumidifiers air flow rate. This software sets, measures and controls the air flow rate, eliminating any chance of incorrectly calculating the ducts pressure drops, thereby making dehumidifier installation and system commissioning extremely easy and quick and reducing installation times and costs. Technical sheet of the range SPR 0130 0160 0190 0210 0260 0300 Dehumidifying capacity L / day 128 157 190 210 268 302 Recirculation air flow rate m 3 /h 1200 1600 1600 2000 2800 2800 Fresh air flow rate m 3 /h 0-1200 0-1200 0-1200 0-2000 0-2000 0-2000 Hot water coil capacity kw 9,8 9,8 9,8 16,5 17 17 Heat recovery system efficiency % 70 70 70 70 70 70 Alimentazione elettrica V/ph/Hz I--------------- 230/1/50 ----------------I I--------------- 400/3/50 ----------------I Technical sheet of the range SPR 0350 0450 0580 0750 0950 1100 1400 Dehumidifying capacity L / giorno 358 452 581 760 955 1120 1380 Recirculation air flow rate m 3 /h 3800 4000 4800 7000 8200 11000 12500 Fresh air flow rate m 3 /h 0-2000 0-2000 0-2000 0-6000 0-6000 0-11000 0-12500 Hot water coil capacity kw 26,5 26,5 27 48 55 76 83 Heat recovery system efficiency % 70 70 70 70 70 70 70 Power supply V/ph/Hz I----------------------------------------- 400/3/50 ------------------------------------------I Dehumidification power in following conditions: Air Temperature 30 C, Relative Humidity 80% net of contribution of air renewal Recovery system efficiency with indoor 26 C/60% RH outdoor -5 C/80% RH conditions 18

15 8 5 6 10 1 Inlet fresh outdoor air flow 2 Indoor recirculation air flow 3 Expelled outdoors air flow 4 Supply air flow indoors 5 High-efficiency crossed flows heat recovery system 6 Exhaust air exhaust fan 7 Recirculation air fan 8 Outdoor air damper 9 Calibration damper 10 Discharged air gravity damper 11 Compressor 12 Evaporator coil 13 Condenser coil 14 Reheat coil (optional) 15 Outdoor fresh air filter 16 Indoor recirculation air filter 1 2 16 9 12 13 14 3 4 7 11 Options: - ACF: automatic control flow - Hot water reheat coil with valve - Desuperheater - Dirty filters sensor - Softstart - RS485 serial port - EU4 Efficiency air filters - Condensate drain pump - Clock card - time bands - Electric coils - Wall remote terminal - Outdoor version - Manometers - Summer / Winter operating modes Key to symbols used Heat Recovery Isothermic version High Efficiency Fans HEAT RECOVERY ISOTHERMIC ENERGY SAVING De-humidification R-410A R410A refrigerant gas EC plug fans DEHUMIDIFICATION OZONE FRIENDLY VARIABLE SPEED Winter time heating mode R-134a R134a refrigerant gas Low noise version HEATING OZONE FRIENDLY LOW NOISE Summer time cooling mode Scroll Compressors Air filter COOLING SCROLL COMP. AIR FILTERS FREE COOLING Free-Cooling BLDC FULL INVERTER BLDC Compressors RS485 PROTOCOL CONNECTION LINK Remote control via RS485 19

HiDew S.r.l. Operational Office: Via dell artigianato, 1 35020 San Pietro Viminario (PD) - Italy Phone: +39 049 9588510 Registered Office: Viale Spagna, 31/33 35020 Tribano (PD) - Italy Phone: +39 049 9588511 Fax: +39 049 9588522 www.hidew.it info@hidew.it HDEN0500014-0