comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

Similar documents
Ductless Series Variable Speed Split Systems

R-410A DUCTLESS SPLIT SYSTEMS. Single Zone, Dual Zone & Multi Zone Air Conditioners and Heat Pumps

R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils

Presents. Variable Speed Heat Pump Ductless Split Systems

Single and Multi-Zone Ductless Split Systems

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

Single - Zone Systems

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

Model: Ceiling Cassette V 9k-24k

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Specifications, Performance & Submittal

S1CV/S1HV Single-Zone

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Specifications and Performance S2H

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Lennox Mini-Split Systems Year-Round Comfort and Performance

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

InverterFlex SERIES InverterFlex Systems condition up to five rooms

Residential and Light Commercial Ductless Systems Catalog

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Divisions of ECR International, Inc. Commercial Zone-Comfort Solutions

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

... Air Conditioners & Heat Pumps Light Commercial ...

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Ductless SPLIT SYSTEMS. cool only HEAT PUMPS

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

Ductless Systems. Right product for the right application

EMI ENGINEERING SUBMITTAL

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

DUCTLESS SPLIT SYSTEMS

Ductless Split Systems Ceiling Cassette Heat Pumps

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

AIR CONDITIONERS CENTRAL & DUCTLESS. napoleonheatingandcooling.com

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

Discover Innovative Comfort

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS

K sin. Mini Split Air Conditioners and Heat Pump

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Quiet Comfort Dependable Performance Guaranteed Energy-Efficient. Mini-Splits Single-Zone & Multi-Zone Systems

Specifications and Performance

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

EMI ENGINEERING SUBMITTAL

comfort, room by room ROOM AIR PRODUCTS CATALOG

TECHNICAL SPECIFICATIONS

Mitsubishi System Technologies:

RSG16**S1M. Split System Air Conditioner 16 SEER

Air Conditioning & Heating. Ductless Product Catalog

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

comfort, room by room NEW! Room Air Product Catalog

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Up to SEER 26.1 Wall Mount Heat Pump

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

LV Series. SEER 20+ Wall Mount Heat Pump

AIR CONDITIONERS 2017 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units

13 SEER CONDENSING UNITS & AIR HANDLERS

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Specifications and Performance

Feel the difference! Uncompromised Comfort Unrivaled Value C US. Mark of Superior Quality SERIES

LG Comfort Solutions. Comfort Solutions You Never Thought Possible

LV Series. SEER 15+ Concealed Built in Heat Pump

DC Inverter Smart VRF Products(R410A)

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Air Conditioning & Heating. Ductless Heating & Cooling Systems

Product Data INDUSTRY LEADING FEATURES / BENEFITS

About Daikin: WARNINGS:

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Transcription:

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

2 EMI E-verter Ductless Split Systems are an excellent alternative for cooling and heating indoor space when traditional systems are not practical or feasible. E-verter Split Systems are small in size and very flexible for zoning because no ductwork is required. EMI E-verter Split Systems combination of an outdoor condenser and indoor air handler fits almost anywhere simple to install and economical to operate and are ideal for a wide range of applications. Computer rooms, restaurants, apartments and condos, nursing homes, warehouse offices, schools, doctors offices, hotels and motels. EMI E-verter Split Systems primary feature is the inverter-driven compressor that can modulate the speed at which it operates, adjusting the capacity to closely match the load and demand. This functioning reduces temperature swings, cycling, compressor noise and energy usage & costs, while more precisely maintaining comfort. In this brochure you will find a variety of E-verter Split System options that are right for almost any application. E-verter Benefits Variable speed load matching High efficiency 3:1 turn down increases reliability with less cycling Quiet operation Minimal room temperature swings Single or dual point power connections (without electric heat only) Turbo heat plus two stage heating with optional E-boost electric heat Widest selection of energy star eligible ductless products Inverter Inverter technology allows the compressor in the outdoor condensing unit to continuously adjust its speed to match the load and demand of the zone. This method is a substantial improvement on a conventional split system s efficiency because the system compressor will run longer, but at a lower speed, as the system approaches the set temperature. When demand is low, the speed of the compressor, and consequently the electric meter, will slow down; running down to ~1/3 of the rated capacity. This helps to maintain the room temperature with a higher degree of consistency and accuracy. When demand is high, the compressor will speed up, running at full capacity. The compressor does not start and stop nearly as often, which provides energy cost savings, as well as extends the life of the compressor, offering a significant overall payback. Since the compressor does not always run at the highest speed, there is a noise reduction at the outdoor condenser, and at the indoor air handler since it doesn t consistently have to run at the highest fan speed to satisfy demand.

Wall Mounted Air Handlers WLHV Series Cooling & Heat Pump (9,000 24,000 Btuh, 2.6 7.0 kw) Hand-Held Wireless Optional Wall Mounted Wired Wall Mounted Air Handlers Indoor Model WLHV09 WLHV09 WLHV12 WLHV12 WLHV18 WLHV18 WLHV24 WLHV24 Outdoor Model S1CV9000 S1HV9000 S1CV2000 S1HV2000 S1CV8000 S1HV8000 S1CV4000 S1HV4000 Type A/C HP A/C HP A/C HP A/C HP Energy Star Eligible Nominal Cooling (Btu/hr) 9,000 9,000 12,000 12,000 18,000 18,000 24,000 24,000 Min - Max Cooling (Btu/hr) 3,000 9,000 3,000 9,000 4,000 12,000 4,000 12,000 6,000 18,000 6,000 18,000 8,000 24,000 8,000 24,000 Nominal Heating (Btu/hr) 8,800 10,000 18,000 21,000 Min - Max Heating at 47 F (Btu/hr) 2,900 8,800 3,300 10,000 6,000 18,000 7,000 21,000 Low Temp Turbo Heating at 17 F (Btu/hr) 7,000 7,000 14,000 14,000 SEER 16.7 16.7 17.0 17.0 17.0 17.0 17.0 17.0 HSPF 8.2 8.5 9.5 9.5 EER 13.5 13.5 12.0 12.0 13.0 13.0 11.0 11.0 COP 3.2 3.0 3.5 3.2 Cooling Operating Range ( F) 60 115* 32 115 60 115* 32 115 60 115* 32 115 60 115* 32-115 Heating Operating Range ( F) 0 75 0 75 0 75 0-75 Line Length feet 100 100 100 100 100 100 100 100 Indoor unit # of Fan Speeds 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto Sound Levels: High (dba) 45 45 45 45 56 56 56 56 Medium (dba) 42 42 42 42 54 54 54 54 Low (dba) 40 40 40 40 52 52 52 52 Outdoor unit Transformer Kit required for 115Vac Condenser Sound Level (low/high) (dba) 61/64 61/64 61/64 61/64 65/68 65/68 65/69 65/69 Options E-boost Electric Heat (208/230v only) (kw) 3 3 3 3 3 & 5 3 & 5 3 & 5 3 & 5 Low Ambient Cooling Range ( F) 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 ** ** ** Becomes 32-115 F with addition of optional Crank Case Heater Kit Must add optional Crank Case Heater Kit (AC Only) and Wind Baffles Kit Additional Sizes Coming Soon Added Features Include: Sweep function on louvers provides a wide cooling area. Dry mode allows for dehumidification, with minimal change in room temperature. Selectable filter indicator notifies occupant when cleaning is required. Condensate pump accessory includes integral safety switch with 48" (1.2 m) available lift. Internal mount up to 24,000 Btu/h. Test mode overrides controls for easy start-up and diagnostics. 3

Cassette Air Handlers CAHV Series Cooling & Heat Pump (9,000 24,000 Btuh, 2.6 7.0kW) Hand-Held Wireless Optional Wall Mounted Wired Cassette Air Handlers Indoor Model CAHV09 CAHV09 CAHV12 CAHV12 CAHV18 CAHV18 CAHV24 CAHV24 Outdoor Model S1CV9000 S1HV9000 S1CV2000 S1HV2000 S1CV8000 S1HV8000 S1CV4000 S1HV4000 Type A/C HP A/C HP A/C HP A/C HP Energy Star Eligible Nominal Cooling (Btu/hr) 9,000 9,000 12,000 12,000 18,000 18,000 24,000 24,000 Min - Max Cooling (Btu/hr) 3,000 9,000 3,000 9,000 4,000 12,000 4,000 12,000 6,000 18,000 6,000 18,000 8,000 24,000 8,000 24,000 Nominal Heating (Btu/hr) 8,400 8,800 17,000 19,000 Min - Max Heating at 47 F (Btu/hr) 2,800 8,400 2,900 8,800 5,600 17,000 6,200 19,000 Low Temp Turbo Heating at 17 F (Btu/hr) 7,000 7,000 14,000 14,000 SEER 15.0 15.0 15.8 15.8 17.0 17.0 17.0 17.0 HSPF 7.7 7.7 9.0 9.0 EER 13.0 13.0 12.0 12.0 13.0 13.0 11.0 11.0 COP 3.0 3.0 3.1 3.0 Cooling Operating Range ( F) 60 115* 32 115 60 115* 32 115 60 115* 32 115 60 115* 32 115 Heating Operating Range ( F) 0 75 0 75 0 75 0 75 Line Length (feet) 100 100 100 100 100 100 100 100 Indoor unit # of Fan Speeds 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto Sound Levels: High (dba) 41 41 41 41 44 44 44 44 Medium (dba) 40 40 40 40 43 43 43 43 Low (dba) 39 39 39 39 42 42 42 42 Outdoor unit Sound Level (low/high) (dba) 61/64 61/64 61/64 61/64 65/68 65/68 65/69 65/69 Options E-boost Electric Heat (208/230v only) (kw) 1½ 1½ 1½ 1½ 3 3 3 3 Low Ambient Cooling Range ( F) 0 115 0 115 0 115 0 115 0 115 0 115 0 115 0 115 ** ** ** Becomes 32-115 F with addition of optional Crank Case Heater Kit Must add optional Crank Case Heater Kit (AC Only) and Wind Baffles Kit Additional Sizes Coming Soon Added Features Include: Factory installed condensate pump includes integral safety switch with 36" (0.9 m) available lift. Easily configured for fresh air intake and up to 2 branch discharge locations. Motorized discharge vanes on CAHV18-24. Infra-red compatible remote control with test mode CAHV models. Selectable filter indicator notifies occupant when unit needs filter cleaning. 4

Universal Ceiling & Floor Mount Air Handlers UNHV Series Cooling & Heat Pump (9,000 24,000 Btuh, 2.6 7.0 kw) Single unit can be used in either a ceiling or floor mount application. Hand-Held Wireless Optional Wall Mounted Wired Universal Ceiling & Universal Floor Mount Air Handlers Indoor Model UNHV09 UNHV09 UNHV12 UNHV12 UNHV18 UNHV18 UNHV24 UNHV24 Outdoor Model S1CV9000 S1HV9000 S1CV2000 S1HV2000 S1CV8000 S1HV8000 S1CV4000 S1HV4000 Type A/C HP A/C HP A/C HP A/C HP Energy Star Eligible Nominal Cooling (Btu/hr) 9,000 9,000 12,000 12,000 18,000 18,000 24,000 24,000 Min - Max Cooling (Btu/hr) 3,000 9,000 3,000 9,000 4,000 12,000 4,000 12,000 6,000 18,000 6,000 18,000 8,000 24,000 8,000 24,000 Nominal Heating (Btu/hr) 8,800 10,000 18,000 21,000 Min - Max Heating at 47 F (Btu/hr) 2,900 8,800 3,300 10,000 6,000 18,000 7,000 21,000 Low Temp Turbo Heating at 17 F (Btu/hr) 7,000 7,000 14,000 14,000 SEER 16.7 16.7 17.0 17.0 17.0 17.0 17.0 17.0 HSPF 8.2 8.5 9.5 9.5 EER 13.5 13.5 12.0 12.0 13.0 13.0 11.0 11.0 COP 3.2 3.0 3.5 3.2 Cooling Operating Range ( F) 60 115* 32 115 60 115* 32 115 60 115* 32 115 60 115* 32 115 Heating Operating Range ( F) 0 75 0 75 0 75 0 75 Line Length feet 100 100 100 100 100 100 100 100 Indoor unit # of Fan Speeds 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto Sound Levels: High (dba) 45 45 45 45 56 56 56 56 Medium (dba) 42 42 42 42 54 54 54 54 Low (dba) 40 40 40 40 52 52 52 52 Outdoor unit Sound Level (low/high) (dba) 61/64 61/64 61/64 61/64 65/68 65/68 65/69 65/69 Options E-boost Electric Heat (208/230v only) (kw) 3 3 3 3 3 & 5 3 & 5 3 & 5 3 & 5 Low Ambient Cooling Range ( F) 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 ** ** ** Becomes 32-115 F with addition of optional Crank Case Heater Kit Must add optional Crank Case Heater Kit (AC Only) and Wind Baffles Kit Additional Sizes Coming Soon Added Features Include: Multiple drain pans are factory installed, no field modification required. Dry mode allows for dehumidification, with minimal change in room temperature. Selectable filter indicator notifies occupant when cleaning is required. Easily configured for fresh air intake. Plastic filter grille standard, optional metal grille available. Condensate pump accessory includes integral safety switch with 48" (1.2 m) or 144" (3.6 m) available lift Optional wired or hand-held controller. 5

Single Zone Condensers Variable Speed Ductless Split Systems Single Zone S1CV Series Cooling (9,000-24,000 Btuh, 2.6-7.0 kw) Single Zone S1HV Series Heat Pump (9,000-24,000 Btuh, 2.6-7.0 kw) Side Discharge Condensers Single Zone nominal NOMINAL model number OF COOLING HEATING CIRCUITS CAP. BTUH, (kw) CAP. BTUH, (kw) S1CV9000/S1HV9000 1 9,000 (2.6) 8,800 (2.6) S1CV2000/S1HV2000 1 12,000 (3.5) 10,000 (2.9) S1CV8000/S1HV8000 1 18,000 (5.2) 18,000 (5.3) S1CV4000/S1HV4000 1 24,000 (7.0) 21,000 (6.2) Hail Guard/Wind Baffle Accessory Comfort Features: 3:1 turn down for increased comfort with decreased temperature swings. Single point power connection is standard. (Electric Heat models require Dual Point power connection.) Standard cooling operation down to 32 F (0 C) outside temperature. Standard heat pump heating operation down to 0 F (-13 C) outside temperature. Application flexibility with up to100 EQUIVALENT feet (30.5 m) of interconnect refrigerant piping, supporting 35' (10.6 m) of elevation difference. Side discharge cabinet with durable injection molded base and enclosed compressor compartment for reduced noise. Coil ground clearance of 12" (0.3 m) provides added protection from the environment year round. Environmentally friendly R-410A refrigerant. Easy access connections for refrigerant gauges. Corrosion resistant, powder-coated steel cabinet with PVC coated wire guard coil protection. One year parts, five year compressor warranty. 6 Options: Low ambient kits field installed for cooling operation down to 0 F (-18 C). Hail guard/wind baffle/architectural louvers. 115v transformer kit field installed for 9,000 and 12,000Btu/hr models (not available on systems with supplemental electric heat).

Accessories Condensate Pump includes Integral Safety Switch. Provides available lift to Air Handlers as follows: Condensate Pump Wall Mounted Air Handlers to 48" (1.2m) Universal Air Handlers to 48" (1.2m) or 144" (3.6m) Hand-Held Wireless (standard) Convenient full function cooling and heating control included with every system. Wired OEM Wall Control (optional) Provides access to functions as cool or heat, timer, fan speed, temperature setting. Hand-Held Wireless Interconnecting Cord Extension (optional) Comes in 15' sections to locate Wired OEM Wall Control up to 150' away from the air handler. Bi-Flow Filter Dryer Keeps moisture out of refrigerant (field installed) Crank Case Heater (for Straight Cool Models) (standard on Heat Pump Models) Line Sets (requires insulation on both tubes) Architectural Louvers, Wind Baffles and Hail Guards Wall-Mounted Wired Branch Duct Discharge Air Collar Kit (for Cassette Air Handlers) Merv 11 Filter (for Universal Air Handlers) Floor Mount Trim Kit (for Universal Air Handlers) Metal Return Grill and Filter (for Universal Air Handlers) 7

Single Zone Air Conditioners / Heat Pumps www.e-verter.com For complete product information, please refer to individual unit specifications, installation and operation manual, and other product literature found on www.enviromaster.com. Due to on-going product development, specifications are subject to change without notice. Contractor Assistance: 800.325.5479 Enviromaster International 2201 Dwyer Avenue Utica, New York 13501 Phone: 800.325.5479 Fax: 866.432.7329 E-Mail: emi@enviromaster.com Web: enviromaster.com Part # 240009376 Rev. 7/12