NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS

Similar documents
NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

Prescriptive Requirement for Smoke Control

UNIVERSITY COLLEGE LONDON PREMISES FIRE SAFETY HANDBOOK. Regulatory Reform (Fire Safety) Order 2005 DARWIN BUILDING

EMERGENCY EVACUATION PLAN

BUILDING FIRE STRATEGY (Operational & Fire Engineering Information)

EMERGENCY EVACUATION PLAN

FIRE ALARM SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS (Student Halls of Residences & Sleeping Accommodation)

BUILDING FIRE STRATEGY

IFE Level 4 Certificate in Fire Science and Fire Safety

PREMISES FIRE SAFETY HANDBOOK

FIRE ALARM SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS (All Buildings - Excluding Sleeping Accommodation)

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

BUILDING FIRE STRATEGY (Operational & Fire Engineering Information)

BUILDING FIRE STRATEGY

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

PREMISES FIRE SAFETY HANDBOOK

Kensington Aldridge Academy, London W10

RELIGIOUS, FESTIVAL & OTHER DECORATIONS - FIRE SAFETY GUIDANCE

Loss Prevention Standards

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

Fire Risk Assessment

FIRE RISK ASSESSMENT NOT KNOWN 15/10/ SOMERTON COURT BROADMOSS DRIVE SIMON ROFFEY

Fire Risk Assessment

Specified Systems List

LYHA Fire Safety Policy

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

UCL FIRE EXTINGUISHER SCALING & LOCATION POLICY

Areas of the building to which access was not available. Details of any onsite management (if known)

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

Charlotte Building, 17 Gresse Street, London W1T 1QL

Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011

The Code of Practice for Fire Safety in Buildings 2011 It comprises 7 parts and 1 annex:

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

Fire Design Guide. Introduction Scope Aims Consultation Design Strategy Compartmentation Provision...

Design of Fire safety in Multi Occupancy Residential Accommodation

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

Fire safety procedure

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

Fire Safety and Fire Risk Management Procedures, Fire Safety Systems Testing Instructions and Log Sheets

Fire Risk Management Policy. UK September 2017

Case Study 1 Underground Car Park

Building Consent Application Compliance Schedule Information

BUILDING FIRE STRATEGY

Building Construction i. approx. age ii. building structure iii. cladding iv. floors v. walls vi. roof

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

Princess Court Cornbrook Park Road Old Trafford Manchester M15 4FE

Fire Safety. A TUC guide for trade union activists

Fire protection documentation. CFPA-E Guideline No 13:2015 F

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire Risk Assessment Guidance

Fire Risk Assessment (FRA) Checklist

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

Active & Passive Fire Protection System. Page 1 Kalidasan S BT IN SSP-OP

Firefighting operations on fire alarm panels F5-04 GD

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Fire Risk Assessment

Fire Risk Assessment 2016

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

GENERAL FIRE SAFETY TERMS & DEFINITIONS

Design Guidelines Fire Safety in New and Refurbished Buildings

Policy for Safe Evacuation of Persons with Disabilities

MECHANICAL, ELECTRICAL & PUBLIC HEALTH (MEP), UTILITIES, SERVICES, LABS & FIRE BRIGADE EQUIPMENT - DESIGN GUIDANCE

Fire Risk Assessment Safety Checklist

Management Standard: Fire Safety

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

(Fire) Emergency Evacuation Plan

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

The Regulatory Reform (Fire Safety) Order 2005 Fire Risk Assessment Proforma

Fire Risk Assessment

1970s building housing main school reception and support offices. Well managed buildings with no significant risk of a fire occurring.

Fire Safety Policy 2018/19

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

UNIVERSITY OF OXFORD FIRE RISK ASSESSMENT

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

Agency for Health Care Administration

PREMISES FIRE SAFETY HANDBOOK

FIRE SAFETY AND PREVENTION POLICY

Trust Policy and Procedure Document Ref. No: PP (017) Policy Statement Statement of Intent 4 LEGISLATION.5

Fire Risk Assessment

RIBA response to the second phase of the Independent Review of Building Regulations and Fire Safety

Compliance Schedule Handbook Prepared by the Ministry of Business, Innovation and Employment

Fire Risk Assessment. ABC Car Workshop. Prepared for. Redacted

FIRE RISK ASSESSMENT

Fire Safety Design Guide

Approved Document for New Zealand Building Code Warning Systems Clause F7 Third Edition

What you need to know about. Maintaining essential safety measures in your building

GDST Fire Safety Strategy March 2016

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

What are the Contents of an Effective Fire Safety Plan? Name: Date: Address of Project: Building Permit Number:

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY

London Borough of Hammersmith & Fulham

London Borough of Hammersmith & Fulham

Unit 2 Fire Safety (Zone 1)

Fire Risk Assessment. Prepared for CTP (Wakefield) Ltd. Location Office Three St Pauls Place 129 Norfolk Street Sheffield South Yorkshire S1 2JE

Transcription:

Mandatory Fire Safety Instruction Reference A: Reference B: NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS Approved Document B Fire Safety (Volume 2) the Building Regulations 2010: - Para 0.13 Management of Premises. The Building Regulations 2010: Approved Document B (Volume 2) - Appendix G Fire Safety Information required under Regulation 38. What both the Principal Designer & Principal Contractor need to know: Mandatory - UCL the Client requires that design teams comply with the Regulatory Reform (Fire Safety) Order 2005. Specifically, the protection of UCL staff, students and visitors by providing suitable and effective control measures to mitigate the impact of fire from their design. Mandatory - UCL the Client requires design teams to comply with Regulation 38 (The Building Regulations 2010). Specifically, suitable and sufficient fire safety information is provided prior to Practical Completion / Client Occupation to allow safe occupation, fire brigade information and maintenance of the building s fire safety systems. Mandatory Mandatory - the fire strategy (where required) for the new buildings / projects must be a dynamic document to reflect alterations and changes to the design of the building throughout construction, to practical completion and occupation by UCL. Design team fire engineering services need to monitor and update strategy to reflect design to practical completion - not just for Building Regulation Approval. Mandatory - UCL the Client requires that all elements of external cladding system are non-combustible in design. Prohibited Acceptable Prohibited - to introduce complex or inappropriate measures to the building design for the sake of aesthetics or convenience, which requires fire safety management controls on occupation by UCL that solely rely on fire safety management by occupants to resolve building design issues. Statuary Authorities -it is recommended that both the design and general fire strategy be discussed at RIBA Stage 4 (D) with the Local Authority Fire Brigade, Building Control Officers and UCL Fire Safety team. This is to ensure that design concept will not present problems at handover affecting project completion. Principal Designer & Contractors - it is recommended that both the design and general fire strategy and Regulation information required is discussed & reviewed at RIBA Stage 4 (D) to check understanding & assumptions prior to Stage 5 (E) handover and practical Completion/ client occupation. Note - UCL Employers Requirements see UCL Fire Safety Technical Notes available at: www.ucl.ac.uk/fire/documents/ucl_fire_safety_project_design_summary_aide_memoir.pdf Last Amended: Dated: Apr 18 1.

1.0. Regulation 38 the Building Regulations - Fire Safety Manual & Information 1.1. Reference B - requires that the person carrying out the project work shall give fire safety information to the Responsible Person 1 or his representative not later than the date of completion of works, or the date of occupation of the building or extension whichever is the earlier information shall be supplied by the Principal Contractor and Designers prior to handover. 1.2. Documents and Drawings are to be provided electronically via Web Download or Transfer / Data Stick / CD marked with Project Name and set out in separate folders with Docs (Word/PDF) / Drawings (.DWG) / Drawings (.PDF) formats. 1.4. The UCL Fire Safety Manager shall on behalf of the UCL Responsible Person, be provided with fire manual information set out with the following in documents, drawings, strategies and specifications as follows: 2.0. Required Architectural Documentation & Drawings: 1 x Set of General Arrangement (GA) - As Built drawings in AutoCAD & PDF; 1 x Set of Fire Strategy - As Built drawings in AutoCAD and PDF; o Fire Strategy Drawings - shall provide information on Means of Escape (MoE) and travel distances to escape routes / inner room arrangements, o Fire Strategy Drawings - shall provide information on project fire compartmentation, appropriate Fire Resistance (30, 60 or 120 minutes) and separation of building structures, indicating fire walls, fire doors fire shutters / curtails and their fire rating, ting, signage the floors and general layouts; (i.e. location of fire separating elements, including cavity barriers in walk-in spaces); o Fire Doors - fire doors, self-closing fire doors and other doors equipped with relevant hardware (see UCL Fire Safety Tech Note TN013); o Fire Rated Glazing details of relevant screens or windows (see UCL Fire Safety Tech Note TN013); o External Building Cladding Details - fire rating and as built information; 1. The Fire Safety Order 2005 defines the Responsible Person as the employer (UCL Council) in relation to a workplace, if the workplace is to any extent under their control. However, the day-to-day responsibility is devolved to the UCL President and Provost, who is the employer s representative. Last Amended: Dated: Apr 18 2.

o Safety Signage - indicate fire signage (see UCL Fire Safety Tech Note TN090); o Firefighting Equipment - indicate dry or wet risers / dropping mains and other firefighting equipment and location of hydrants outside the building; o Disabled People - any provision incorporated into the building to facilitate the evacuation of Disabled people, disable refuge positions; Any other relevant information (Details & Plans AutoCAD & PDF); 3.0. Required Mechanical, Electrical & Public Health (MEP) Documentation & Drawings: Air Handling Units, Fume Cupboards/MSC, Containment Level (CL) 2/3 and Specialist Laboratory Controls: o 1 x set of System Schematics & Interface - As Installed Drawings in AutoCAD and PDF showing locations of AHU Yellow Fire Brigade overrides control panels and I/O devices; o Systems Cause & Effect Information - As Installed details of Yellow Box override, Cause and Effects and operational documents in MS Word / MS Excel and PDF; Fire Alarm (FA) System: o 1 x set of Fire Alarm - As Installed drawings in AutoCAD and PDF showing locations of smoke / heat detector heads, alarm call-points, alarm sounders, alarm control panels and I/O devices; o Fire alarm Cause & Effect information - As Installed documents in MS Excel and PDF; o Fire alarm Zone Chart information - As Installed drawings in AutoCAD and PDF; o Copy of FA Zone & Device Addresses - documents in MS Excel; o Copy of sounder levels for rooms and individual areas; Emergency Lighting (EL) System: o 1 x set of Emergency Lighting - As Installed drawings in AutoCAD and PDF showing locations of EL light units control panels etc. o Copy of lighting levels (dark test) for rooms and individual areas; Last Amended: Dated: Apr 18 3.

Smoke Control Arrangements and System: o 1 x set of Smoke Vents (for Atrium / Stairs / Basement as Appropriate), complete with Controls and Fire Dampers - As Installed drawings in AutoCAD and PDF showing locations of smoke vents manual overrides and control panels etc.; o Smoke System Cause & Effect Information - As Installed documents; o Copy of smoke vent type, controls, operation details - documents as necessary; Smoke Curtains & Fire Shutters: o 1 x set of Smoke Curtain / Shutters & Controls - As Installed drawings in AutoCAD and PDF showing locations of curtails shutters and any manual overrides and control panels etc. o Cause & Effect Information - As Installed documents; o Copy of curtain / shutter type, controls, operation details - documents as necessary; Sprinklers / Water Mist / Fire Suppression Systems: o 1 x set of sprinkler or other fire suppression system(s), including isolating valves and control equipment locations - As Installed drawings in AutoCAD and PDF showing locations of details and any manual overrides and control panels etc. o Cause & Effect Information - As Installed documents; o Copy of system type, controls, operation details - documents as necessary; Fire Brigade Equipment: o Dry Riser / Foam Inlets - test certificates; Pack to include any other relevant drawings or documents; Last Amended: Dated: Apr 18 4.

4.0. Principal Documents and Plans to be As Built folder Setting Out for Regulation 38 information (For Delivery for Practical Completion / Client Occupation): 4.1. General areas information required: Architectural General Arrangement (GAs) Plans (AutoCAD & PDF) Atrium / Stair Smoke Vent (Details & Plans AutoCAD & PDF) Basement Smoke Extract Systems (Details & Plans AutoCAD & PDF) Dry Riser / Foam Inlets (Details & Plans AutoCAD & PDF) External Building Cladding Details (fire rating details & Plans AutoCAD & PDF) Fire Door Certs (Details / PDF) Fire Dampers and Grilles (Details & Plans AutoCAD & PDF) Emergency/Standby Generator (Details & Plans AutoCAD & PDF) Emergency Lighting Layouts (Details & Plans AutoCAD & PDF) Fire Alarm and Detection (Details & Plans AutoCAD & PDF) Fire Curtains or Shutters (Details & Plans AutoCAD & PDF) Fire Stopping Register (Details & Plans AutoCAD & PDF) Fire Strategy (Details /Documents) Fire Strategy Plans (Details & Plans AutoCAD & PDF) Glazed Fire Rated Window / Screens (Details & Plans AutoCAD & PDF) Intumescent Paint Cert (Details & Plans AutoCAD & PDF) Sprinklers Water Mist -Fire Suppression (Details & Plans AutoCAD & PDF) Any other relevant information not covered above Current Regulation 38 from Approved Document B, Appendix G of the Building Regulations Information attached: Last Amended: Dated: Apr 18 5.