General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Technical Information

General Specifications

Technical Information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Technical Information

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

General Specifications

General Specifications

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

Two global companies, one solution.

General Specifications

General Specifications

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

EOTec 2C32 Installation Guide

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

4 Channel Contact Closure SFP DIN Fiber Link System

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

FDA241, FDA221 Siemens ASD

Touch Screen 1 loop Addressable Fire Alarm Panel

General Specifications

AO Annunciator Module

FDA241, FDA221 Siemens ASD

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

Fire and Gas Monitoring Panel ST7-HV

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

Assembly. Host Sub-D Alarm

General Specifications

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Analog Input Module IC670ALG630

Four channel video link For low cost video transmission

P R O D U C T D ATA S H E E T

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

APPLICATION DATA SHEET

APPLICATION DATA SHEET

RS485 MODBUS Module 8AI

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Intensity Level. Intensity Control. Mounting Plate. Signal Type Switch Signal Ports USB DC Power Port

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

SUPREMATouch. Modular Fire & Gas Detection System

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

AQ7275 OTDR Optical Time Domain Reflectometer

4120 Fire Alarm Network Reference

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

AQ7275 OTDR Optical Time Domain Reflectometer

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

EC-BOS-602/616 AX Security

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Intensity Level. Intensity Control. Signal Type Switch. 12V Power Port. Signal Ports

FAST/TOOLS. Alarm System Performance Analysis (ASPA) Bulletin 50A01A00-02EN

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

C-Bus Four Channel General Input Unit Installation Instructions

Network Display Unit Installation Instructions

User s Manual YTA610 and YTA710 NEPSI Certification

User s. Manual) Model VJUK Limit Alarm for Universal Input

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

P R O D U C T D ATA S H E E T

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

FC724 Fire control panel

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

segment redundant fieldbus power supply

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

Proven Technology for Safety Instrumentation Systems

Operating Manual MS220DA

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

FC722 Fire control panel

Four-Door Access Controller User s Manual

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

SUPREMATouch. Modular Fire & Gas Detection System

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Instrumentation Products and Applications

Model 4880 Status Output Display Module Manual

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Transcription:

General Specifications Model A2NN30D Node Interface Unit (for N-IO) GENERAL The Node Interface Unit (NIU) has an interface function that allows a Field Control Unit (FCU) to communicate with an I/O unit for N-IO and an interface function that allows NIUs to communicate each other. Furthermore, the NIU supplies power to the I/O unit for N-IO. Refer to the GS N-IO System Overview (GS 33J62A10-01EN) together with this GS. [Release 6] STANDARD SPECIFICATIONS For the installation environment for this product, refer to the GS N-IO System Overview (GS 33J62A10-01EN). Module Configuration 24 V DC Output Power Supply Units (A2PW503 or A2PW504): 2 N-ESB Bus Modules (A2EN501): 2 N-ESB Bus Interface Uplink : 1 port / N-ESB Bus Module (for N-ESB bus or optical ESB bus) Downlink:1 port / N-ESB Bus Module (for N-ESB bus or optical ESB bus) Number of I/O Unit for N-IO Connections Up to 6 units / NIU External Alarm Input Function The NIU has an external alarm input terminal for an external device and an alarm is displayed as a system alarm on a Human Interface Station (HIS). Input terminal: Pressure clamp terminal (2-pin) Input signal: Voltage input ON voltage 18 to 26.4 V OFF voltage 5.0 V or less Input current (when 24 V input): 2.4 ma±20% Cable thickness: 0.5 to 2.5 mm 2 (AWG 20 to 14) (*2) *1: The withstanding voltage between the input signal and system is 500 V AC for 1 minute. *2: For the cable termination process, refer to the section Signal Cable for A2BN3D of the GS Field Connection Specifications (for N-IO) (GS 33J62A20-01EN). Maintenance Function The NIU has a Micro-USB for maintenance. The Setting of the node address is possible with a NIU Node Number Setting tool. *1: NIU Node Number Setting tool is stored in the software medium for CENTUM VP R6 Installation Method Specified by suffix code. DIN rail mount type Wall mount type (M4 x 4 screws) Supply Power Specified by suffix code. Voltage: 100 to 240 V AC, frequency: 50/60 Hz Voltage: 24 V DC Withstandng voltage Between Input and Output terminal: 3000 V AC, for 1 minute (100 to 240 V AC) 500 V AC, for 1 minute (24 V DC) Between Input and Ground terminal: 1500 V AC for 1 minute (100 to 240 V AC) 500 V AC for 1 minute (24 V DC) Insulation resistance Between Input and Output /Ground terminal : 50 MΩ or more at 500 V DC. F01E.ai Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 Copyright Feb. 2015 (YK) 4th Edition Dec. 28, 2015 (YK)

2 Power Supply Input Connection Use the dedicated power supply input cable included with the main unit by connecting it to the Power Supply Bus Unit, Vertical Type (AEPV7D) (Style S2 or later). The operating temperature range is different between this product and the Power Supply Bus Unit, Vertical Type (AEPV7D) so be careful when installing them. Node Interface Unit (A2NN30D): 0 to 60 C (-40 to 70 C optional temperature environment) Power Supply Bus Unit, Vertical Type (AEPV7D): -20 to 70 C If you do not use the dedicated cable, you need to supply power to the power supply input terminal of the following power supply unit. For the cable termination process, refer to the TI CENTUM VP Installation Guidance (TI 33J01J10-01EN). Power supply input terminal (L/+) Power supply input terminal (N/-) Ground terminal Terminal Connection For A2PW503 For A2PW504 Power supply input terminal (L/+) Pressure clamp terminal AC input (L) DC input (+) Power supply input terminal (N/-) Pressure clamp terminal AC input (N) DC input (-) Ground terminal M4 screws Protective grounding Functional grounding Power Consumption 100 to 240 V AC input: 190 V A 24 V DC input: 150 W Weight Approx. 4.2 kg (configuration maximum value) F02E.ai Feb. 1, 2015-00

3 EXTERNAL DIMENSIONS A2NN30D- 0 (DIN rail mount type) Unit: mm Power supply input cable length: 1500, minimum bending radius: 25 (When the /NCBL option code is specified, cables are not included) (70) 174.5 30 177.2 Ventilation area 25 88 DIN rail TH35-7.5 248 (248) Minimum cable area (30) Nominal Tolerances: When the reference dimension is over 0.5 mm and equal or less than 120 mm, its nominal tolerance is ± 0.8 mm, while its combination of nominal tolerance is ± 1.5 mm. When the reference dimension is over 120 mm, its nominal tolerance is in accordance with JEM 1459. F03E.ai Feb. 1, 2015-00

4 The name of each part of the Node interface Unit is shown in the following figure B1 B2 P1 P2 Slot for power supply unit (P1) Slot for N-ESB bus module (B1) Slot for power supply unit (P2) Slot for N-ESB bus module (B2) DIN rail release tab Connector for connecting power supply unit (POWER1) External alarm input terminals Connector for connecting power supply unit (POWER2) F-SB bus cable connector (BUS1) F-SB bus cable connector (BUS2) BUS1 BUS2 AUX IN + - POWER1 HKU + - FG PWR1 POWER2 PWR2 Check terminal (for maintenance) Grounding terminal HKU terminal (Not supported) PWR3 PWR4 PWR5 PWR6 System power supply output connectors ( PWR3) ( PWR1) ( PWR2) ( PWR4) ( PWR5) ( PWR6) F09E.ai Feb. 1, 2015-00

5 A2NN30D- 1 (Wall mount type) Unit: mm Power supply input cable length: 1500, minimum bending radius: 25 (When the /NCBL option code is specified, cables are not included) (70) 171 30 5 5 170 160 Ventilation area 25 (248) 248 238 Minimum cable area (30) F04E.ai *1: M4 screws for Wall mount type: effective screw length 6 mm x 4. Nominal Tolerances : When the reference dimension is over 0.5 mm and equal or less than 120 mm, its nominal tolerance is ± 0.8 mm, while its combination of nominal tolerance is ± 1.5 mm. When the reference dimension is over 120 mm, its nominal tolerance is in accordance with JEM 1459. Feb. 1, 2015-00

6 Details on the N-ESB Bus Modules N-ESB Bus for uplink N-ESB Bus for uplink N-ESB Bus for downlink N-ESB Bus for downlink F05E.ai F06E.ai A2NN30D- 00 (N-ESB Bus for uplink, N-ESB Bus for downlink) A2NN30D- 01 (N-ESB Bus for uplink, Optical ESB bus (0 to 5 km) for downlink) A2NN30D- 02 (N-ESB Bus for uplink, Optical ESB bus (5 to 50 km) for downlink) Optical ESB Bus for uplink Optical ESB Bus for uplink N-ESB Bus for downlink Optical ESB Bus for downlink F07E.ai F08E.ai A2NN30D- 10 (Optical ESB Bus (0 to 5 km) for uplink, N-ESB Bus for downlink) A2NN30D- 20 (Optical ESB Bus (5 to 50 km) for uplink, N-ESB Bus for downlink) A2NN30D- 11 (Optical ESB bus (0 to 5 km) for uplink, Optical ESB bus (0 to 5 km) for downlink) A2NN30D- 21 (Optical ESB bus (5 to 50 km) for uplink, Optical ESB bus (0 to 5 km) for downlink) A2NN30D- 12 (Optical ESB bus (0 to 5 km) for uplink, Optical ESB bus (5 to 50 km) for downlink) A2NN30D- 22 (Optical ESB bus (5 to 50 km) for uplink, Optical ESB bus (5 to 50 km) for downlink) Feb. 1, 2015-00

7 MODEL AND SUFFIX CODES Node Interface Unit (for N-IO) Model A2NN30D Node Interface Unit (for N-IO) Suffix Codes Option Codes Description -4 Dual-redundant Communication, Dual-redundant power supply 3 24 V DC output power supply (100 to 240 V AC input) 4 24 V DC output power supply (24 V DC input) 0 Always 0 0 DIN rail mount type 1 Wall mount type 0 Always 0 0 N-ESB Bus for uplink 1 Optical ESB Bus(0-5 km) for uplink 2 Optical ESB Bus(5-50 km) for uplink 0 N-ESB Bus for downlink 1 Optical ESB Bus(0-5 km) for downlink 2 Optical ESB Bus(5-50 km) for downlink 0 With no explosion protection 1 With explosion protection 0 Basic type 1 With ISA Standard G3 option 2 With temperature (-40 to 70 C) option 3 With ISA Standard G3 option and temperature (-40 to 70 C) option /NCBL With no power supply cable /ATDOC Explosion Protection Manual (*2) *1: An input cable for the power supply unit. *2: Select the option code /ATDOC to follow the ATEX Directive when any of N-IO components are used for explosion protection. APPLICABLE STANDARDS Refer to the GS Integrated Production Control System CENTUM VP System Overview (GS 33J01A10-01EN). ORDERING INFORMATION Specify model, suffix codes, and option codes when ordering. For selecting the right products for explosion protection, please refer to TI 33Q01J30-01E without fail. TRADEMARKS CENTUM is a registered trademark of Yokogawa Electric Corporation. Other company and product names appearing in this document are trademarks or registered trademarks of their respective holders. Dec. 28, 2015-00 Subject to change without notice.