PARTICULATE EMISSION MONITORING

Similar documents
S304 and S305 Dust Emission Monitors. User Manual. Distributor

Dust Alert 75. *shown with optional external keypad and display

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Snifter. User Manual. Distributor

Dust Concentration Meter

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Snifter ATEX22 VERSION. User Manual. Distributor

Sintrol Snifter A1+ Manual. Version 1.2.2

INTRINSICALLY SAFE S314X AND S315X

The Emergence of Triboelectric Technology

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

THE INDUSTRIAL APPROACH TO DUST MONITORING

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Specifications - Installation and Operating Instructions 2X 1/2 NPT OR M20 ELECTRICAL ENTRY. 3/4 NPT or 3/4 BSPT 5/8 [15.88]

MONITORING & CONTROL. the expert approach. Dust Sensors.

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Emissions monitoring solutions

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

portable gas analyser

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

SILO PROTECTION SYSTEMS

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Mobrey ultrasonic Liquid level detection systems

CONTROL UNIT: REFERENCE MANUAL

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

LaserFOCUS VLF-250 Engineering Specification

PUV, PIR and PFO Series BROCHURE

Electronic Flow Switches

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Analog Room Pressure Monitor RPC Series

Frequently asked questions: Intelligent Transmitter Series

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

A New Standard of Excellence

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

WG Buried Cable Perimeter Detection System

Sitron s CF Line of Flow Switch Monitors

The A-series Eletta Flow Monitor with local indication and analog output

Low Temperature Zirconia Oxygen Analyzer

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

PTE0705 Electric Fence Monitor

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

Inductive Conductivity

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Accuracy by Design Products for the HVAC Professional

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

APPLICATION DATA SHEET

Advanced Test Equipment Rentals ATEC (2832)

IntelliPack : 800 Series

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

APM110 LOW AIR VELOCITY ALARM

Speed and Frequency Seite 1 von 7

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

SITRANS F. SITRANS FUG1010 Clamp-on Gas Flowmeters. Answers for industry.

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

IC-45AV Vertical Clean Centrifuge

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

Enraf Servo Gauge 854 XTG

SUPREMATouch Modular Fire & Gas Detection System

International comparison of validation methods for dust concentration measurement

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

OPTISENS TUR 2000 Technical Datasheet

Automatic Isokinetic Sampler ST5

Ultrasonic Point Level Switches

Product data sheet Palas Fidas 200 S

Substation Monitoring System

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

IGD.CO.UK

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

USER MANUAL FOR OPERATING SYSTEM

Temperature Controllers

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Sentry G3 Machinery Protection Monitor

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Process Gas Chromatograph

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

SIMRAD GD10PE IR GAS DETECTOR

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Software Version 2.01 LEVEL MONITOR MODEL 220

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Gas ventilation monitoring and control system

TPF Series Ozone Generators

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Module Features are-configurable, no module jumpers to set

Transcription:

PARTICULATE EMISSION MONITORING CLEAN AIR SOLUTIONS

EMP 7 PARTICULATE EMISSION MONITOR CLEAN AIR SOLUTIONS

- EMP7 WHAT IT DOES Continuously monitors for filter media leakage EMP7 is a simple self contained 2-wire, particulate monitor with 4 20 ma output designed to feed a PLC, display device such as AUD1 or Connect Network via Connect Access Card or Numeric Display, AUD1 Continuously monitors particulate flow, primarily emissions from process plants Indicates condition and efficiency of cleaning system Maintains absolute calibration Models available for mg/m 3 (gr/ft 3 ) or mg/s (gr/s) following calibraton to Iso-kinetic sample Self Test Diagnostics including Statistical History, Run Time, Power Up and Optional Remote Diagnostics Reporting PRODUCT DESCRIPTION Made a reality by recent advances in low power digital signal processing, ISE technology is as significant a step forward now as the introduction of AC Triboelectric technology was in 1992. OPERATIONAL RANGE Suitable for a wide range of dust collection and materials handling operations and gas cleaning plants Dust concentrations from 0.01 mg/m 3 (4 10 6 gr/ft 3 ) Accurate for most particle and particle characteristics Insertion temperatures from 20 C over 650 C ( 4 F to over 1200 F) with additional hardware For duct sizes from 50 mm (2 ) to outlets over 10 m (33 ft) Suitable for most stack material. e.g. steel, brick etc. BENEFITS Detects all particles regardless of composition Very sensitive due to ISE Technology Monitoring No range switching or other adjustments Calibration is constant Extremely wide range of concentration and mass flow Tolerates extremely high leakage of signal due to insulator bridging Seamless interface into industrial controls systems, such as PLC The EMP7 utilises ISE technology. Each particle travelling through the process develops an electrical charge. As the particle passes or impacts with the sensing element, a current is induced which is processed in EMP7 by a method called Impulse Signature Extraction ( Ise ). ISE technology extracts the basic characteristics (the signature ) of the impulsive signals induced by individual particles in the gas stream. Since these characteristics are related to such things as the particle velocity, EMP7 is able to compute velocity as a parameter, and therefore to calculate the emission level as either mass flow rate or mass density as required. In addition, although ISE technology processes the entire signal from the sensing element, its algorithm effectively negates the potentially erroneous effects of the DC component of the signal, so ISE technology shares all the advantages of existing AC Triboelectric technology. 3

- EMP7 TECHNICAL SPECIFICATION FUNCTIONS Monitoring units calibrated Monitoring units diagnostics OUTPUTS Emission specification Emission function INSTRUMENT SPECIFICATION mg/m 3 (gr/ft 3 ) user defined automatic or mg/s (gr/s) Statistical history, run time diagnostics, power-up diagnostics and optional reporting 4 20 ma Enclosure rating IP66/NEMA 4 Enclosure size Power supply Insertion temp range Connection required on duct Log (concentration/mass flow) ø88 125 mm high (ø3.5 5 ) not including sensor length 10 32 V DC 20 C to 200 C ( 4 F to 392 F), see supplier for higher temperature options 1 BSPT socket Sensing element material 316 Stainless steel (5 mmod 300 mm (standard cable length) 3/16 12 ) Sensing element options Air purge requirments Air pressure Air consumption Electrical specification between sensing head and electrical input Solid rod, tubular, teflon coated, multiple supports, cable type, other lengths available Connection: 1/8 gas thread on side of unit 400 kpa (60 psi) max 1.7 17 m 3 /hr (1 10 cfm) pulsed 2 core screened data cable: max 5000 m (16,400 ft) Resolution 0.001 mg/m 3 (0.4 10 7 gr/ft 3 ) Range stability ±1% 4 20 ma signal FEATURES Extremely wide, adjustment free range (0.01 mg/m 3 to 1 kg/m3 or 4 10 6 gr/ft 3 to 400 gr/ft 3 ) Simple 4 20 ma, 2-wire output connection Output is true mass density (mg/m 3 ) (gr/ft 3 ) or true mass flow rate (mg/s) (gr/s) depending on model selected Full internal electrical isolation to prevent potential corruption due to ground potential differences Resolution of 0.001mg/m 3 (4 10 7 gr/ft 3 ) Logarithmic output for wide range displays, but also easily converted to linear AUD1 numeric DISPLAY or PLC (optional) EMP7 4

EMP6B PARTICULATE EMISSION MONITOR CLEAN AIR SOLUTIONS

- EMP6B Note: This brochure is compatible with the original EMP6 brochure and refers to the new part numbers in the B series. WHAT IT DOES Continuously monitors for filter media leakage Indicates and transmits relative condition of bags Provides a 4 20 ma and 0 10 V DC output designed to feed a PLC or other display device Continuously monitors particulate flow, primarily emissions from process plants Can be calibrated for mg/m 3 (gr/ft 3 ) or mg/s (gr/s) following calibration to Iso-kinetic sample Push button and remote input to enable zero and span checks Built in data logging capability for redundancy Acts as a preventative maintenance tool PRODUCT DESCRIPTION The EMP6B utilises AC Coupled Triboelectric technology. As particles travel through the process they develop a charge. This charge is transferred as the particle passes or impacts the sensing element. The resulting current is amplified, filtered, rectified and further filtered looking only at the AC component, to give a linear representation of the concentration or mass flow rate of the particles in the gas stream. The reason for measuring the AC component is that compared to the DC component the electronics are more sensitive. The AC signal is substantially less affected by influences such as amplifier noise and process parameters, which includes the buildup of process dust on the sensing rod. The EMP6B remote Active Head totally filters out any 50 Hz or 60 Hz frequencies related to mains supply. The amplified signal is then sent via data cable to Control Unit for further processing and display. OPERATIONAL RANGE Applicable for all types of outlet stack geometrical arrangements Insertion temperatures up to 200 C (392 F), higher if required Applicable to most particulate types For duct sizes from 50 mm (2 ) to outlets over 10 m (33 ft) Dust concentrations from 0.01 mg/m 3 (4 10 6 gr/ft 3 ) Suitable for a wide range of dust collection, gas cleaning and stack emissions Suitable for most stack material, e.g. steel, brick etc. BENEFITS Detects most particles regardless of composition. Very sensitive due to AC coupled technology. Can monitor extremely small particles, e.g. galvanising fume (A0.1 μm) EMP6-4200B: 100-240 VAC EMP6-3200B: 18-32 VDC Control Unit with 200 ο C Active Head Can be calibrated for large range of concentrations or mass flow rates 0.01 mg/m 3 to 800 mg/m 3 (4 10 6 gr/ft 3 to 0.35 gr/ft 3 ) A seamless interface with industry standard PLC, data logger or SCADA Can dramatically reduce plant downtimes when interfaced into existing plant monitoring equipment FEATURES Proven AC Triboelectric technology Relay time delay feature Dual relay outputs SD card slot for data logging (ASCII comma delimited) Digital two way communication to ensure product integrity Sensitivity adjustment to aid in the elimination of bridging Air purge port Simple installation Alarm level adjustment ATEX II 3 D&G and MACT compliant 6

- EMP6B TECHNICAL SPECIFICATION FUNCTIONS Bar graph Alarm time delay Visual indication of emission density 0 9 seconds in 1 second steps to prevent false alarms due to pulsing MODES OF OPERATION The EMP6B is a continuous monitoring device for particulate emissions in a gas stream. The instrument is applied in an uncalibrated indicative mode in which levels are displayed and recorded in a relative scale (0-100%) or as a 4 20 ma scale which ensures that the signal output to PLC, SCADA system or data logger has the same value as that at the Control Unit. The EMP6B gives a linear representation of either mg/m 3 or mg/s (gr/ft 3 or gr/s), when calibrated to gravimetric standards. The EMP6B also has 2 relay modes Normal and Failsafe. Normal The alarm relay is de-energised when the EMP6B is powered up. Failsafe The alarm relay is energised when the EMP6B is powered up. The alarm relay is de-energised when the EMP6B is in the alarm state. This mode is used to operate external alarm, indicating power failure. Historical Logging of Data For improved preventative maintenance and compliance with some permit agreements, it may be necessary to have all historical information charted for future reference. The EMP6B carries an SD card slot for data logging and recording internally through ASCII comma delimited format. The system is user settable through the system port (adjustments include averaging time, sample rate). Sensitivity Adjustable sensitivity within the active head (high, medium and low available) OUTPUTS PARTICULATE CONCENTRATION OR MASS FLOW Specification 4 20 ma (1 K max) or 0 10 V (10 K min) Function Full range of particulate level ALARM RELAY Specification 8A Resistive/3.5A Inductive 2 Function CONTROL UNIT Enclosure rating Enclosure size Enclosure material Power supply Bargraph display Temperature range Active head ACTIVE HEAD Insertion temperature range Connection required on duct Enclosure temperature range Enclosure rating Enclosure material Sensing element material Sensing element options Air purge requirments Electrical specification between active head and control unit Gain switch High High/High Level Alarm, High/Low Level Alarm, Low Low/Low Level Alarm IP54, ATEX II 3 D&G 280 mm 190 mm 130 mm (254 mm 164 mm mounting) Plastic composite 100 240 V AC 50/60 Hz or 18 32 V DC 20 step LED 20 C to 60 C ( 4 F to 140 F) One per control unit P2-45200B: 20 C to 200 C ( 4 F to 392 F) 1 BSPT socket 20 C to 60 C ( 4 F to 140 F) IP54, ATEX II 3 D&G Aluminium 316 Stainless steel Wire cable [standard]. Also available; solid rod, tubular, extendable, PTFE coated, tubular ceramic, wearresistant alloys and multiple supports, at any length Connection: 1/8 gas thread on side of unit Air Pressure: 400 kpa (60 psi) max air consumption: 1.7 17 m1/hr (1 10 cfm) pulsed 4 core screened data cables: BELDEN 8723NH (or equivalent) max 200 m (656 ft) Three positions (located on the Active Head): High (0 20 mg/m 3 ), Medium (0 150 mg/m 3 ) Low (0 1000 mg/m 3 ), Nominal only: depends on material velocity, geometry 7

BBD6B BROKEN BAG DETECTOR CLEAN AIR SOLUTIONS

- BBD6B BROKEN BAG DETECTOR Note: This brochure is compatible with the original BBD6 brochure and refers to the new part numbers in the B series. WHAT IT DOES OPERATIONAL RANGE BENEFITS Continuously monitors for filter media leakage Indicates relative condition of bags Acts as a preventative maintenance tool PRODUCT DESCRIPTION The BBD6B utilises AC Coupled Triboelectric technology. As particles travel through the process they develop a charge. This charge is transferred as the particle passes or impacts the sensing element. The resulting current is amplified, filtered, rectified and further filtered looking only at the AC component, giving a linear representation of the concentration or mass flow rate of the particles in the gas stream. The reason for measuring the AC component is that, compared to the DC component, the electronics are more sensitive. The AC signal is substantially less affected by influences such as amplifier noise and process parameters, which includes the build-up of process dust on the sensing rod. The BBD6B remote Active Head transfers via a digital signal totally filters out any 50 Hz or 60 Hz frequencies related to mains supply. The amplified signal is then sent via data cable to the Control Unit for further processing and display. Suitable for a wide range of dust collection and stack emissions Applicable for all types of outlet stack geometrical arrangements Insertion temperatures up to 200 C (392 F), higher if required Applicable to most particulate types For duct sizes from 50 mm (2 ) to outlets over 10 m (33 ft) Dust concentrations from 0.01 mg/m 3 (4 10 6 gr/ft 3 ) Suitable for most stack material e.g. steel, brick etc Optional hazardous area (positively pressurised) BBD6-4200B: 100-240V AC Control Unit with 200 C Active Head Detects most particles regardless of composition Very sensitive due to AC coupled technology Can monitor extremely small particles eg. galvanising fume (A0.1 μm) Can be used over a wide range of particulate densities Can assist in dramatically reducing plant down time through filter failures BROKEN BAG DETECTOR 9

- BBD6B BROKEN BAG DETECTOR TECHNICAL SPECIFICATION FEATURES Proven AC Triboelectric technology Relay time delay feature Sensitivity adjustment Air purge port to aid in the elimination of bridging Simple Installation Alarm level adjustment Active Head to the Control Unit mounting up to 100 metres apart ATEX II 3 D&G compliant MODES OF OPERATION The BBD6B indicates instantaneous levels of particulate emissions stream. The instrument is usually in an uncalibrated indicative mode in which levels are displayed in a relative scale (0 100%). The BBD6B also has 2 relay modes N ormal and Failsafe. Normal The alarm relay is de-energised when the BBD6B is powered up. Failsafe The alarm relay is energised when the BBD6B is powered up The alarm relay is de-energised when the BBD6B is in the alarm state Is used so that both power failure and high emissions are alarmed. FUNCTIONS Bar graph Alarm time delay Sensitivity OUTPUTS Name Specification Function CONTROL UNIT Enclosure rating Enclosure size Enclosure material Power supply Bargraph display Temperature range Active head ACTIVE HEAD Insertion temperature range Connection required on duct Electrical specification between active head and control unit Temperature range Enclosure rating Enclosure material Sensing element material Sensing element options AIR PURGE REQUIREMENTS Connection Air pressure Air consumption Visual indication of emission density 0 9 seconds in 1 second steps to prevent false alarms due to pulsing Adjustable sensitivity within the active head (high, medium and low available) Alarm relay 8A resistive, 1A inductive Emission alarm IP54, ATEX II 3 D&G 280 mm 190 mm 130 mm (254 mm 164 mm mounting) Plastic composite 100 240 V AC 20 step LED 20 C to 60 C ( 4 F to 140 F) One P2 45200B: 20 C to 200 C ( 4 F to 392 F) 1 BSPT socket 4 core screened data cables: BELDEN 8723NH (or equivalent) max 100 m (330 ft) 20 C to 60 C ( 4 F to 140 F) IP54, ATEX II 3 D&G Aluminium 316 Stainless steel Wire cable [standard]. Also available; solid rod, tubular, extendable, PTFE coated, tubular ceramic, wearresistant alloys and multiple supports, at any length 1/8 gas thread on side of unit 400 kpa (60 psi) max 1.7 17 m 3 /hr (1 10 cfm) pulsed BROKEN BAG DETECTOR 10

CONTROLS PTY LIMITED 268 MILPERRA ROAD, MILPERRA NSW 2214, AUSTRALIA WWW.MECAIR.PENTAIR.COM Note: The information and data contained in this document are based on our general experience and are believed to be correct. They are given in good faith and are intended to provide a guideline for the selection and use of our products. Since the conditions under which our products may be used are beyond our control, this information does not imply any guarantee of final product performance and we cannot accept any liability with respect to the use of our products. The quality of our products is guaranteed under our conditions of sale. Existing industrial property rights must be observed. PL PENTAIR ING 5117 2017 Pentair. All Rights Reserved.