Performance Chart Electrical Data

Similar documents
Performance Chart Electrical Data

Performance Chart Electrical Data

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Performance Chart Electrical Data

Classix 6" 6" Round Lens Downlight

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Downlight

Evoke Square Downlight

Hornet HP. Round Glass Downlight

Performance Chart Electrical Data

Essenza. Square Downlights

Essenza. Round Downlights

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Lens Wall Wash

Evoke Round Downlight

Velato. Recessed Slot Adjustable Multiples

Hornet HP. Semi-Recessed 4-Light Square Multiple

Hornet HP. Recessed 4-Light Square Multiple

Classix 6" 6" Round Adjustable C3M

Classix 6" 6" Round Adjustable C3

Classix 6" 6" Round Lens Wall Wash

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke Round Adjustable C3

Classix 6" 6" Round Adjustable C3

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Evoke Square Adjustable C3M

Murro HP. 3.5" Round Surface Canopy Wall Wash

Hornet HP. Square Glass Downlight

Evoke Square Adjustable HP

HORNET-HP-R- A14-3 3LT LED

Evoke Square Adjustable HP

Classix 6" 6" Round Downlight

Etch 2' x 2' Recessed LED

Performance Chart Electrical Data

Grüv Flare Regressed. Recessed Linear LED

Cylindrix III Mini. 3.5" Round Surface Canopy

Grüv Flare Regressed. Recessed Linear LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Linea 1.5. Linear Direct Wall Wash LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Fino. Asymmetric Wall Mount Indirect LED

Linea 2.5. Linear Indirect LED

Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot. Standard Patterns " "

Linea 2.5. Linear Direct/Indirect LED

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Linea 3.5. Linear Direct/Indirect LED

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

LIGHT CHANNEL 45 COMPLETE FIXTURE

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

LIGHT CHANNEL TRIM 1.6

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

3.75 Gyro Shift Multiples Single Head

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

NOVA CEILING WALL GRAZER WITH REMOTE POWER

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Truss Surface SURFACE

Claude Indirect Wall WALL

Linea 1.5. Linear Direct/Indirect LED

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

TUBE ARCHITECTURAL DS-PD05

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

12 inches to 120 inches

DATE TYPE 40 DELIVERED PERFORMANCE

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

Max 4 Flush Lens RECESSED

DIMMING 0-10V Continuous

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

120V 12V LED LAMPS. Proven LED performance, superior savings and a broad range of options for landscape lighting systems

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

E10 & L9 Low Wattage Light Cone Data

80 Watts FLANGE FINISH

IHOL-4DR / IRD400 4 Gravity LED Downlight

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

LED Control Solutions

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

IHOL-6DR / IRD600 6 Gravity LED Downlight

VESICA LINEAR SUSPENDED VES L

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

LED Linear Design Highlights

Lamp: K K K K K K

Transcription:

2% Nitrogen Infused Acrylic Pendant Nitro (23W, 36W, 51W) Features Nitro A16 is a high performance architecturally styled pendant for ambient and general lighting applications in retail and supermarket spaces. Offered with various wattages ranging from 27 watts to 94 watts. A 16 inch 2% nitrogen infused refractor surrounds the source, reducing glare and providing a comfortable ambient light level. With a choice of flood, wide flood or very wide flood distributions, the Nitro LED is a great replacement for CMH or CFL sources. Product Overview Type: Round Pendant Wattage: 23, 36, 51, 70, 94 Lumen Output: up to 6,361; up to lm/w CBCP: up to 14,414 Color Temp: 2700K, 3000K, 3500K, 4000K, Class A CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) + typ. (2700K, 3000K, 3500K) Class A, 3000K LED available Dimming: TRIAC & ELV (27W-51W) - 5% Dim 0-10V (canopy mount only) - 1% Dim Performance Chart Watts Delivered Lumens LPW CBCP Color Temp 23 2,099 5,344 3000K-83 36 2,732 76 6,899 3000K-83 51 3,848 9717 3000K-83 70 4,577 65 10,666 3000K-83 94 6,185 66 14414 3000K-83 Data is based on 3000K-83 IES files available on website Data is based on optics See pages 5-6 for data on other beam spreads Nitro (70W) 5 Nitro (94W) Electrical Data 23W 36W 51W Watts Amps Watts Amps Watts Amps 120V 23 0.19 36 0.30 51 0.43 277V 23 0.08 36 0.13 51 0.18 70W 94W Watts Amps Watts Amps 120V 70 0.58 94 0.78 277V 70 0.25 94 0.34 Electronic constant current LED driver LIT-20 06/13/18 Page 1 of 7

Ordering Information NIT-A17 1 2 3 4 5 6 7 8 1 2 3 Model NIT Wattage 23 36 51 70 94 Housing Finish WT - white texture BT - black texture ST - silver texture For other RAL colors, consult factory 5 6 7 Voltage 120 (for C-Clamp mounting option only) 120-277 Beam Spreads FL - flood, 35 WF - wide flood, VWF - very wide flood, 65 Color Temp 83 CRI + CRI 27-2700K-83 279-2700K-+ 3CLA - Class A 30-3000K-83 309-3000K-+ 35-3500K-83 359-3500K-+ 40-4000K-83 4 Mounting C4 - canopy, 4' stem* length C8 - canopy, 8' stem* length B4 - busway (B40, B50, Bc), 4' stem* length B8 - busway (B40, B50, Bc), 8' stem* length CCL-SCP4 - C-Clamp with straight cord (6'), 4' stem* length CCL-SCP8 - C-Clamp with straight cord (6'), 8' stem* length CCL-CCP4 - C-Clamp with coil cord (12" length at rest/5' extended), 4' stem* length CCL-CCP8 - C-Clamp with coil cord (12" length at rest/5' extended), 8' stem* length *Field cuttable For custom lengths, consult factory 8 LE/TE - TRIAC/ELV dimming, 5% dim (23W-51W only) 0-10V - 0-10V dimming; 1% dim (canopy mount only) ND - non-dimming (all wattages) LIT-20 06/13/18 Page 2 of 7

Specifications Application Retail and supermarket ambient and display lighting Construction Extruded aluminum heat sink and driver enclosure Formed sheet metal Acrylic 2% nitrogen infused refractor Optical Beam Spread Options: 35, Wide,, Very Wide 65 LED Color Temp Options: 2700K, 3000K, 3500K, 4000K CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) + typ. (2700K, 3000K, 3500K) Class A*, 3000K LED available R9 Values: 11 (83 CRI), 55 (92 CRI) Binning: 3 MacAdam (SDCM) Life: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs *Class A LED: Class A LED s have a CRI > 80 and a GAI > 80. CRI defines color Naturalness and GAI defines color Saturation. Both being high delivers rich colors and pure whites. s LE/TE - Leading Edge, TRIAC, forward phase/trailing Edge, ELV, reverse phase (23W-51W only) 0-10V dimming available (canopy mount only) ND - non-dimming (all wattages) See pages 7 for more dimming information Note: Mounting and wattage affects dimming options available, see chart below Finish Powder coat paint Consult factory for custom finishes Mounting Canopy, Busway or C-Clamp Certifications CSA tested to UL standards Indoor use only Warranty 5 year limited warranty Electrical Wattage: 23, 36, 51, 70, 94 Electronic constant current LED driver, 120V or 277V input This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Amerlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. Dimming Options Depending on Selected Mounting and Wattage: Wattage Canopy Mount Busway Mount C-Clamp Mount 23 ND, 0-10V, LE/TE ND, LE/TE ND, LE/TE 36 ND, 0-10V, LE/TE ND, LE/TE ND, LE/TE 51 ND, 0-10V, LE/TE ND, LE/TE ND, LE/TE 70 ND, 0-10V ND ND 94 ND, 0-10V ND ND LIT-20 06/13/18 Page 3 of 7

4" octagonal j-box supplied by others 6 1 /2 (23W-51W) 10" (70W, 94W) 1 1 /4 Ø3 15 /16 Stem Length 4' or 8' Ø6 3 /4 3 15 /16 (23W-70W) 6 7 /16" (94W) 2 1 /2 11 7 /8 Ø16 1 /8 Canopy Mount Option Additional Mounting Options: 2 13 /16 5 1 /4 Coil Cord & Plug shown (Straight Cord & Plug available) Ø2" max Pipe (supplied by others) Busway (supplied by others) 1/2 C-Clamp Mount Option Busway Mount Option LIT-20 06/13/18 Page 4 of 7

FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES file on website) Wattage: 23W 36W 51W 70W 94W *FOR 94W DATA SEE PAGE 6 Factor: 0.55 0.71 1.0 1.4 * CCT: 2700K-83 3000K-83 3500K-83 4000K-83 2700K-+ 3000K-+ 3500K-+ 3CLA Factor: 0.96 1.0 1.02 1.04 0.80 0.83 0.87 0. 51W LED, 3000K-83 (FL) Distribution, 35º LTL #1234418 Lumens: 3848 Lm/W Wide (WF) Distribution, º LTL#1234419 Lumens: 38 Lm/W Very Wide (VWF) Distribution, 65º LTL # 1234420 Lumens: 3204 Lm/W 2500 10 0 5000 3500 1500 2250 00 5250 3000 10000 7000 0 9717 5 33 15 5120 25 2230 35 349 93 0 6958 5 6762 15 5014 25 25 35 519 100 0 3444 5 3373 15 2966 25 2316 35 2 168 Application Data: wide Very Wide 0 o Aiming Angle Horizontal Footcandles 7.5 167 3.9 3.9 10.0 95 5.3 5.3 12.5 61 6.6 6.6 15.0' 43 7.9 7.9 7.5 120 5.2 5.2 10.0 68 7.0 7.0 12.5 44 8.7 8.7 15.0' 31 10.4 10.4 7.5 59 7.1 7.1 10.0 34 9.5 9.5 12.5 22 12.0 12.0 15.0' 16 14.6 14.6 W D L FC Notes and Definitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Effective Visual Beam length in feet (50% of maximum footcandle level). W=Effective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. LIT-20 06/13/18 Page 5 of 7

FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES file on website) Wattage: 23W 36W 51W 70W 94W *FOR 51W DATA SEE PAGE 5 Factor: 0.25 0.38 * 0.74 1.0 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 2700K-+ 3000K-+ 3500K-+ 3CLA Factor: 0.96 1.0 1.02 1.04 0.80 0.83 0.87 0. 94W LED, 3000K-83 (FL) Distribution, 35º LTL #1234415 Lumens: 6185 Lm/W Wide (WF) Distribution, º LTL#1234416 Lumens: 6361 Lm/W Very Wide (VWF) Distribution, 65º LTL # 1234417 Lumens: 5180 Lm/W 2500 2500 1500 5000 00 5000 3000 10000 00 12500 00 10000 15000 0 14410 5 13550 15 8207 25 3711 35 559 154 0 100 5 10250 15 8089 25 4376 35 838 167 0 5505 5 5395 15 4787 25 3749 35 1211 274 Application Data: wide Very Wide 0 o Aiming Angle Horizontal Footcandles 7.5 247 4.2 4.2 10.0 141 5.6 5.6 12.5 91 7.0 7.0 15.0' 64 8.5 8.5 7.5 179 5.6 5.6 10.0 102 7.4 7.4 12.5 66 9.2 9.2 15.0' 47 11.1 11.1 7.5 95 7.1 7.1 10.0 54 9.6 9.6 12.5 35 12.1 12.1 15.0' 25 14.7 14.7 W D L FC Notes and Definitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Effective Visual Beam length in feet (50% of maximum footcandle level). W=Effective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. LIT-20 06/13/18 Page 6 of 7

DIMMING COMPATIBILITY: Amerlux Nitro fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMATION BELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FACTORY --- TRIAC (Forward Phase) DIMMING (Standard) Utilizes Standard incandescent dimmers that are in wide use in installations across the US. Best for retrofit applications where TRIAC dimmers are installed. 120V or 277V* Dims down to less than 5% light output (most cases) Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! Must meet dimmer Minimum Load Requirements per dimming manufacturer Compatible Dimmers Wall Box (Incandescent Style, Wattage as required) Lutron Diva Lutron Vareo Lutron Nova-T Lutron Skylark Lutron Maestro TRIAC Wiring Diagram TRIAC Dimming Control White Green Central Lutron GP Panel Lutron Grafik Eye QS V+ V- Red ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized ELV dimmers. Best for New Construction applications ELV Wiring Diagram 120V or 277V* Dims down to less than 5% light output (most cases) ELV Dimming Consult Dimming manufacturer for installation Control instructions - DO NOT SHARE NEUTRALS! Must meet dimmer Minimum Load Requirements Compatible Dimmers Wall Box (ELV Style) Lutron Diva Lutron Nova-T Lutron Maestro Leviton Surslide Lutron Vareo Lutron Skylark Leviton Vizio White Green Central Lutron GP Panel with PHPM-PA Interface Lutron Grafik Eye QS with PHPM-PA Interface V+ V- Red 0-10V - DIMMING (-0-10V Option) Integrates into a variety of building management and daylighting controls 0-10V Wiring Diagram 120V or 277V* Dims down to 1% light output Requires interface to turn off power to driver Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! 0-10V Dimming Control Gray Purple White Green 0-10V (-) 0-10V (+) Switched Hot V+ V- Red Compatible Dimmers Wall Box Lutron Diva - DVTV with PP- 120H Interface Leviton Renoir II 0-10v Central Lutron Grafik Eye with GRX-TVI Interface * is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimming installation instructions for 277V wiring diagrams. LIT-20 06/13/18 Page 7 of 7