JEDI Powerful adjustable linear LED projector Concept: Powerful adjustable linear LED projector. Materials: Extruded 18μ anodized aluminum body. Extra clear 4mm thick glass flat screen. Painted black die-cast aluminium end caps. Black polycarbonate driver housing. Optional anodized aluminum side cover for wall mount applications. Marine grade, 1.5% to 2.5% copper content in aluminum alloy. Optic: Internal optical unit composed of a primary cylindrical methacrylate lens, a high reflectance anodized aluminum reflector and an integrated holographic filter for Wall Wash, Grazing, and Flood effects. Spot version comes with individual lenses for more precise beam and higher intensity. Mounting: The body of the fixture is adjustable and can be installed away from the mounting surface by installing the brackets along a special guide. The brackets can slide along the body of the fixture to be positioned according to installation needs. To be completed with stainless steel fixed and adjustable brackets or flush wall mount linear brackets. Driver: Integrated electronic drivers with non dimmable and 0-10V dimmable versions housed in sealed black polycarbonate driver box, two cables provided for 0-10V option. Installation: Cabled with SJ00W 18-3 cable and input/output watertight IP68 Quick Disconnect connectors. Lead and Solo configurations provided with 10ft lead cable. See page 3 for Inline connection configurations.. Color Temperature: 2700 K, 3000 K, 3500 K and 4000 K available CRI: 84 Lumens: 24 (27W) 36 (38W) 48 (49W) 3000ºK 4000ºK 3000ºK 4000ºK 3000ºK 4000ºK Wall Washer 59º x 115º = 2318Lm 2434Lm 3477Lm 3651Lm 4637Lm 4868Lm Wall Grazer 15º x 76º = 2565Lm 2694Lm 3849Lm 4041Lm 5133Lm 5389Lm Flood 32º x 85º 2304Lm 2419Lm 3456Lm 3629Lm 4608Lm 4838Lm Spot 10º x 10º = 1500Lm 1625Lm 2252Lm 2438Lm 3000Lm 3250Lm Refer to pages 4-7 for complete fixture data information. Lumen Maintenance (L70): 50,000hrs Calculation for LED fixtures are based on measurements that comply with with IES LM-80. Voltage: Universal Voltage 120-277V AC 50/60Hz Weight: 14lbs IK: IK10 IP: IP68** Certifications: culus Wet Location Listed E488257, Tested in accordance with LM-79-08 Warranty: 5 year limited warranty * Up to 1 METER DEPTH of water for up to a maximum of 30 MINUTES ** Not suitable for submersible installations Wall Wash Wall Graze Spot Integrated Louver Option Integrated anti-glare louver option pre-installed inside the fixture. *Not available for Spot optics. IP67 IP68 Marine Wall Wash Optic Shown PRODUCT CODE TYPE DRIVER OPTICS 1 LENGTH* COLOR TEMP CABLE 2 LOUVER OPTION + MOUNTING JE JEDI P Projector 10 0-10V WW JE-P-ND-WG-36-HO-30** + 1E2752* ND Non-Dimming WG * Lead time for quick ship fixtures is 1-2 weeks from processed PO date. Consult factory for quantites of over 20 fixtures to confirm lead time. ** Confirm Cable Configuration. FL SP Wall Wash 59º x 115º Wall Grazer 15º x 76º Flood 32º x 85º Spot 10º x 10º 24 24 27 2700K L Lead LV 3 Integrated Louver Option 36 36 30 3000K C Center 48 48 35 3500K E End 40 4000K S Solo 1 2700K and 3500K not available with spot optic 2 See Page 3 for inline cable configurations 3 Integrated louver not available for spot optic Required (See Pg 2) Views 3.27 Available Lengths: 24 / 36 / 48 1.70 3.00 3.20 5.70 Targetti USA - A Targetti Group Company - 750-A W. 17 th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: targettiusa@targetti.com - www.targetti.us - 07.11.18 - Page 1 of 8
MOUNTING BRACKET (REQUIRED) 1E2752 1E2753 Wall Mounting Brackets 1.34 short bracket (set of two) 6.30 long bracket (set of two) 1.81 1.34 2.00 6.30 1E2754 Ceiling mount bracket 1DU2755 1DU2756 1DU2757 Wall Flush Mount Brackets are manufactured as full length side covers with countersunk screw holes to attached to wall. For use with fixtures installed facing up only. 24.25 bracket 36.00 bracket 47.87 bracket +/- 85º +/- 108º SIDE COVER (For use with fixtures installed facing up only) 4.3 to 4.9 9.3 to 9.8 1E2752 1E2753 1E2755 1E2758 1E2756 1E2759 1E2757 1E2760 1E2761 24.25 Side Cover 36 Side Cover 47.87 Side Cover End Cap (single). To be completed with side cover. Standard Anti-Glare Standard Anti-Glare Standard Anti-Glare Standard The side cover is anodized aluminum allows for a fluid finished apperance on an architectural surface. Cover can be field painted to match the architectural facade finish. The standard cover mounts flush with to the top of the fixture, the Anti-Glare cover mounts with a slight standoff to eliminate glare from direct view application. 1.63 3.22 3.15 1E2754 4.80 Wall Flush Mount Bracket 36 / 47.87 36 / 47.87 INTEGRATED LOUVER ACCESSORY Consult Factory 24 Integrated anti-glare louver option pre-installed 36 inside the fixture. For use with Wall Grazer and Wall Wash optics only. 48 Consult factory for more information. Side Cover - Standard Side Cover - Anti-Glare ADDITIONAL CONNECTION CABLES JEPNDLEAD-xx 1 JEP10LEAD-xx 1 JEPNDJUMP-xx 2 JEP10JUMP-xx 2 Additonal IP68 lead cable with IP68 female 3 socket connector. Additonal IP68 lead cable with IP68 female 3 socket connector and sparate 0-10V dimmable connection cord. IP68 Connector cord, 2ft cable for fixture to fixture non-dimmable connection with IP68 male 3 socket connector and IP68 female 3-pin connector. IP68 Connector cord, 2ft cable for fixture to fixture connection with IP68 male 3 socket connector and IP68 female 3-pin connector and sparate 0-10V dimmable connection cord. 1 Additional lead cables are sold in 2 foot increments, from 12 foot (JEPxxLEAD 12) to 80 foot (JEPxxLEAD 80). 2 Connector cords sold in 2 foot increments, from 2 foot (JEPxxJUMP 02) to 20 foot (JEPxxJUMP 20). The standard side cover accessory installed on the entire length of the product can be customised in accordance with the needs of the architectural project. Standard Side Cover Shown Targetti USA - A Targetti Group Company - 750-A W. 17 th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: targettiusa@targetti.com - www.targetti.us - 07.11.18 - Page 2 of 8
Standard Connection Cable Configurations CABLE OPTION L Lead C Center E End S Solo DESCRIPTION 10ft lead cable with IP68 female connector. Inline lead fixture with 1ea IP68 male connector and 1ea IP68 female connector. Inline center fixture with 1Ea IP68 male connector and 1Ea IP68 female connector. Included with outdoor jumper cable. Inline end fixture with 1Ea IP68 male connector. Included with outdoor jumper cable. 10ft lead cable with IP68 female connector. Solo fixture with 1Ea IP68 male connector. NOTE: (2) cables provided for 0-10V dimmable versions. 10 ft power cord Fixture code: L Lead Fixture Male Female Male Fixture code: C Center Fixture Female Male Fixture code: E End Fixture 10 ft power cord Female Fixture code: S Solo Fixture Male Female Targetti USA - A Targetti Group Company - 750-A W. 17 th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: targettiusa@targetti.com - www.targetti.us - 07.11.18 - Page 3 of 8
Optics Wall Wash 59ºx115º Spacing Ratio 1:1.25 Wall Washer Optic for a uniform effect with installation. It makes it possible to obtain a completely homogeneous effect on the wall, avoiding any bright stripes or separate beams that are typical of linear fixtures fitted with visible LED strips. h 13ft 30in-45in ideal spacing *60in max (shown) 24in-36in ideal set back *48in max set back (shown) Wall Graze 15ºx76º Spacing Ratio 1:1 Grazing Optic for a grazing, uniform light effect for installation near the desired wall to be illuminated. h 13ft 20in max set back (shown) *20in max (shown) Spot 10ºx10º Spot Optic for more concentrated, precise lighting. h 20ft 12in max set back (shown) 60in (shown) Targetti USA - A Targetti Group Company - 750-A W. 17 th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: targettiusa@targetti.com - www.targetti.us - 07.11.18 - Page 4 of 8
Photometrics Wall Wash 59ºx115º Polar Graph Cone of Light Fixture Output 2177Lm 3265Lm 4354Lm ftcd ftcd Kelvin Temp 2700K 2700K 2700K 35.00 2 1 Beam Spread Wall Wash Wall Wash Wall Wash 28.00 2 1 IMax 770cd/klm 770cd/klm 770cd/klm 21.00 4 2 Efficacy 81 Lm/W 84 Lm/W 85 Lm/W 14.00 10 5 7.00 39 20 Wall Wash 59ºx115º Polar Graph Cone of Light Fixture Output 2318Lm 3477Lm 4637Lm ftcd ftcd Kelvin Temp 3000K 3000K 3000K 35.00 2 1 Beam Spread Wall Wash Wall Wash Wall Wash 28.00 3 1 IMax 770cd/klm 770cd/klm 770cd/klm 21.00 5 2 Efficacy 86 Lm/W 89 Lm/W 91 Lm/W 14.00 11 5 7.00 42 22 Wall Wash 59ºx115º Polar Graph Cone of Light Fixture Output 2393Lm 3590Lm 4786Lm ftcd ftcd Kelvin Temp 3500K 3500K 3500K 35.00 2 1 Beam Spread Wall Wash Wall Wash Wall Wash 28.00 3 1 IMax 770cd/klm 770cd/klm 770cd/klm 21.00 5 2 Efficacy 89 Lm/W 92 Lm/W 94 Lm/W 14.00 11 6 7.00 43 22 Wall Wash 59ºx115º Polar Graph Cone of Light Fixture Output 2434Lm 3651Lm 4868Lm ftcd ftcd Kelvin Temp 4000K 4000K 4000K 35.00 2 1 Beam Spread Wall Wash Wall Wash Wall Wash 28.00 3 1 IMax 770cd/klm 770cd/klm 770cd/klm 21.00 5 3 Efficacy 90 Lm/W 89 Lm/W 96 Lm/W 14.00 11 6 7.00 44 23 Targetti USA - A Targetti Group Company - 750-A W. 17 th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: targettiusa@targetti.com - www.targetti.us - 07.11.18 - Page 5 of 8
Photometrics Wall Grazer 15ºx76º Polar Graph Cone of Light Fixture Output 2409Lm 3614Lm 4820Lm ftcd ftcd Kelvin Temp 2700K 2700K 2700K 35.00 4 2 Beam Spread Wall Grazer Wall Grazer Wall Grazer 28.00 6 3 IMax 1600cd/klm 1600cd/klm 1600cd/klm 21.00 11 5 Efficacy 89 Lm/W 93 Lm/W 95 Lm/W 14.00 24 12 7.00 95 48 Wall Grazer 15ºx76º Polar Graph Cone of Light Fixture Output 2565Lm 3849Lm 5133Lm ftcd ftcd Kelvin Temp 3000K 3000K 3000K 35.00 4 2 Beam Spread Wall Grazer Wall Grazer Wall Grazer 28.00 6 3 IMax 1601cd/klm 1601cd/klm 1601cd/klm 21.00 11 6 Efficacy 95 Lm/W 94 Lm/W 101 Lm/W 14.00 25 12 7.00 101 50 Wall Grazer 15ºx76º Polar Graph Cone of Light Fixture Output 2549Lm 3973Lm 5297Lm ftcd ftcd Kelvin Temp 3500K 3500K 3500K 35.00 4 2 Beam Spread Wall Grazer Wall Grazer Wall Grazer 28.00 6 3 IMax 1601cd/klm 1601cd/klm 1601cd/klm 21.00 12 6 Efficacy 94 Lm/W 102 Lm/W 104 Lm/W 14.00 26 13 7.00 104 52 Wall Grazer 15ºx76º Polar Graph Cone of Light Fixture Output 2694Lm 4041Lm 5389Lm ftcd ftcd Kelvin Temp 4000K 4000K 4000K 35.00 4 2 Beam Spread Wall Grazer Wall Grazer Wall Grazer 28.00 7 3 IMax 1601cd/klm 1601cd/klm 1601cd/klm 21.00 12 6 Efficacy 95 Lm/W 104 Lm/W 106 Lm/W 14.00 26 13 7.00 106 53 Targetti USA - A Targetti Group Company - 750-A W. 17 th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: targettiusa@targetti.com - www.targetti.us - 07.11.18 - Page 6 of 8
Photometrics Flood 32ºx85º Polar Graph Cone of Light Fixture Output 2163Lm 3245Lm 4327Lm ftcd ftcd Kelvin Temp 2700K 2700K 2700K 35.00 2 1 Beam Spread FL 32ºx85º FL 32ºx85º FL 32ºx85º 28.00 3 1 IMax 699cd/klm 699cd/klm 699cd/klm 21.00 5 2 Efficacy 80 Lm/W 85 Lm/W 88 Lm/W 14.00 10 5 7.00 41 20 Flood 32ºx85º Polar Graph Cone of Light Fixture Output 2304Lm 3456Lm 4608Lm ftcd ftcd Kelvin Temp 3000K 3000K 3000K 35.00 2 1 Beam Spread FL 32ºx85º FL 32ºx85º FL 32ºx85º 28.00 3 1 IMax 699cd/klm 699cd/klm 699cd/klm 21.00 5 2 Efficacy 85 Lm/W 91 Lm/W 94 Lm/W 14.00 11 5 7.00 44 21 Flood 32ºx85º Polar Graph Cone of Light Fixture Output 2378Lm 3567Lm 4756Lm ftcd ftcd Kelvin Temp 3500K 3500K 3500K 35.00 2 1 Beam Spread FL 32ºx85º FL 32ºx85º FL 32ºx85º 28.00 3 1 IMax 699cd/klm 699cd/klm 699cd/klm 21.00 5 2 Efficacy 88 Lm/W 94 Lm/W 97 Lm/W 14.00 11 5 7.00 45 21 Flood 32ºx85º Polar Graph Cone of Light Fixture Output 2419Lm 3629Lm 4838Lm ftcd ftcd Kelvin Temp 4000K 4000K 4000K 35.00 2 1 Beam Spread FL 32ºx85º FL 32ºx85º FL 32ºx85º 28.00 3 1 IMax 699cd/klm 699cd/klm 699cd/klm 21.00 5 2 Efficacy 90 Lm/W 96 Lm/W 99 Lm/W 14.00 12 5 7.00 46 22 Targetti USA - A Targetti Group Company - 750-A W. 17 th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: targettiusa@targetti.com - www.targetti.us - 07.11.18 - Page 7 of 8
Photometrics Spot 10ºx10º Polar Graph Cone of Light Fixture Output 1409Lm 2114Lm 2817Lm ftcd ftcd Kelvin Temp 2700K 2700K 2700K 35.00 23 15 Beam Spread SP 10º SP 10º SP 10º 28.00 36 23 IMax 16544cd/klm 16544cd/klm 16544cd/klm 21.00 63 42 Efficacy 52 Lm/W 56 Lm/W 57 Lm/W 14.00 142 93 7.00 569 374 Spot 10ºx10º Polar Graph Cone of Light Fixture Output 1500Lm 2252Lm 3000Lm ftcd ftcd Kelvin Temp 3000K 3000K 3000K 35.00 24 16 Beam Spread SP 10º SP 10º SP 10º 28.00 38 25 IMax 16544cd/klm 16544cd/klm 16544cd/klm 21.00 67 45 Efficacy 55 Lm/W 59 Lm/W 61 Lm/W 14.00 151 100 7.00 605 402 Spot 10ºx10º Polar Graph Cone of Light Fixture Output 1597Lm 2396Lm 3195Lm ftcd ftcd Kelvin Temp 3500K 3500K 3500K 35.00 26 17 Beam Spread SP 10º SP 10º SP 10º 28.00 40 26 IMax 16544cd/klm 16544cd/klm 16544cd/klm 21.00 72 47 Efficacy 59 Lm/W 63 Lm/W 65 Lm/W 14.00 161 106 7.00 645 424 Spot 10ºx10º Polar Graph Cone of Light Fixture Output 1625Lm 2438Lm 3250Lm ftcd ftcd Kelvin Temp 4000K 4000K 4000K 35.00 26 17 Beam Spread SP 10º SP 10º SP 10º 28.00 41 27 IMax 16544cd/klm 16544cd/klm 16544cd/klm 21.00 73 48 Efficacy 60 Lm/W 64 Lm/W 66 Lm/W 14.00 164 108 7.00 656 431 Targetti USA - A Targetti Group Company - 750-A W. 17 th St. Costa Mesa, CA 92627 - Phone (714) 513-1991 - Email: targettiusa@targetti.com - www.targetti.us - 07.11.18 - Page 8 of 8