FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

Similar documents
September 30, Dear Fire Suppression System Contractor/Designer:

New Construction Fire Inspection Process

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Commercial Remodel/ Add On Rules and Regulations

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

BULLETIN. Permitting Tips (11/10)

Fire Sprinkler Submittal Requirements and Acceptance Testing

AUTOMATIC FIRE SPRINKLER SYSTEMS

You are required to READ ALL PAGES. of this application

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Fire Sprinkler Plan Submittal Form

Brighton Area Fire Authority

Commercial Rules and Regulations

Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

Fire Permit Application

Full Service Central Station Fire Alarm Listing Evaluation

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

FIRE & LIFE SAFTEY STANDARD

FIRE DEPARTMENT SYSTEM PERMIT APPLICATION

Bold items are particular to the City of Euless

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

May 1, Dear Fire Suppression System Contractor/Designer:

FIRE CODE. Coal City Fire District International Fire Code Update. 35 S. DeWitt Place Coal City, IL

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

IOWA STATE FIRE MARSHAL DIVISION Attn: Licensing Administrator

NASSAU COUNTY FIRE PROTECTION PERMIT APPLICATION

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Sandwich Community Fire Protection District. Plan Review Submittal Guidelines and Requirements

Fire Prevention Coffee Break Training. February 2016

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

Liberty Township Fire Department Fire Prevention Bureau. Clean Agent Fire Protection Plan Submittal Checklist

Fire Sprinkler System Design and Installation Requirements

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Department of Planning & Community Jefferson Station 1526 E. Forrest Avenue Suite 100 East Point, GA 30344

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

PLAN REVIEW SUBMITTAL GUIDE

FIRE SPRINKLER SHOP DRAWING SUBMITTAL REQUIREMENTS

Fire Prevention Coffee Break Training. February 2017

CHRISTMAS TREE LOT INFORMATION & REQUIREMENTS

BCCO TRAINING FOR CONTRACTORS

City of Madison Heights Landlord Licensing Program 300 W. Thirteen Mile Road Madison Heights, MI (248)

ADOPTED MODIFICATIONS

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Design & Construction Standards, Revised January

Norfolk Fire Department Fire Prevention & Information

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

PLAN REVIEW FEES. Sprinkler Systems. NUMBER OF Without With SPRINKLERS Inspections Inspections

FIRE SPRINKLER SYSTEMS POLICY

At least 10 calendar days prior to project start date Within the last 30 days of a project that will extend beyond 12 months

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

Commercial Business Licensing Requirements

FIRE SPRINKLER SYSTEMS POLICY

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

D. Reference Standards (Utilize latest editions available):

El Reno Fire Department Fire Alarm Plan Review Worksheet

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Community Development Department Commercial Permit Application

Site Address: Bldg./Suite #: Departments Phone Date Approval Signature A) Planning COMMENTS:

CITY OF PASADENA FIRE DEPARTMENT

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

Medical Gas and Vacuum Systems

Carrollton Fire Rescue

Commercial Application/Plan Review Submittal Checklist

Fire Alarm, Water Flow Alarm & Signaling Systems

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Plan Submittal Checklist

CITY OF DANIA BEACH Local Business Tax Receipt Division 100 W Dania Beach Blvd. Dania Beach, FL Phone: ext 3644 / Fax

SECTION : FIRE ALARM & DETECTION SYSTEMS

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

SECTION ADDENDUM NO. 1 FIRE SPRINKLER SYSTEM

NFPA Fire Inspector I Study Guide

Winnipeg Fire Department Fire Prevention Branch

Colorado Division of Fire Prevention & Control, Fire & Life Safety Section

Fire - Rescue. November 2016

APPLICATION CERTIFICATE OF OCCUPANCY $50.00 FEE (non-refundable)

APPLICATION FOR INSTALLATION OF SPRINKLER SYSTEM.,. :" ROCHESTER, NH FIRE DEPARTMENT FIRE PREVENTION DIVISION

FIRE FIGHTER II APPLICATION PENNSYLVANIA VOLUNTARY FIRE SERVICE CERTIFICATION PROGRAM NFPA Edition

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

HIGH-RISE RETROFIT ORDINANCES - NO and NO

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

SECTION WET-PIPE SPRINKLER SYSTEMS

Narrative Reports As Regulated by 780 CMR, Section 903.0

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

C i t y o f G r o v e r B e a c h ADMINISTRATIVE SERVICES DEPARTMENT

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Transcription:

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS www.madison-heights.org COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 300 W. THIRTEEN MILE RD. MADISON HEIGHTS, MICHIGAN 48071 (248) 583-0831 FAX (248) 588-4143 FIRE DEPARTMENT FIRE PREVENTION BUREAU 31313 BRUSH STREET MADISON HEIGHTS, MICHIGAN 48071 (248) 588-3605 FAX (248) 588-3604 SYSTEM TYPE: CIRCLE ONE COMPLETE PARTIAL SUPERVISED (Entire building - includes smoke/heat detectors, pull stations, etc.) (System with all but smoke detectors) (Sprinkler or duct monitoring) PROPERTY ADDRESS & INFORMATION STREET NUMBER STREET NAME UNIT NUMBER NAME OF BUSINESS AT THIS LOCATION Check here to receive Notices of Repair by facsimile or e-mail. APPLICANT INFORMATION: CONTRACTOR NAME AS SHOWN ON LICENSE STREET ADDRESS E-MAIL ADDRESS ( ) PHONE NUMBER ( ) CITY STATE ZIP FAX NUMBER NOTE: ALL CONTRACTORS MUST REGISTER WITH THE CITY ON A SEPARATE FORM PROPERTY OWNER: FIRST NAME LAST OR BUSINESS NAME STREET ADDRESS ( ) CITY STATE ZIP PHONE NUMBER ALL REQUESTED INFORMATION MUST BE PROVIDED - INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED `

FILL IN THE BOX BELOW COMPLETELY DEPENDING ON THE TYPE OF SYSTEM FIRE ALARM SYSTEMS: INSTALLATION COST: (INCLUDE ALL COSTS INCLUDING ELECTRICAL SUPPLY) TOTAL BUILDING SQUARE FOOTAGE: # OF FIRE AREAS: TOTAL # OF DEVICES: PANELS: PULL STATIONS: HEAT/SMOKE DETECTORS: HORN STROBES: OTHER DEVICE: OTHER DEVICE: KNOX BOX ON BUILDING?: YES NO (IF NO, OBTAIN APPLICATION FROM F.D.) ARCHITECT OR ENGINEER: (IF APPLICABLE) FIRST NAME LAST OR BUSINESS NAME NUMBER STREET NAME ( ) CITY STATE ZIP PHONE NUMBER ( ) FACSIMILE NUMBER (REQUIRED) SEND PLAN REVIEW COMMENTS TO THE : ARCHITECT/ENGINEER APPLICANT ALL SUBMISSIONS MUST INCLUDE THREE COPIES OF THE CONSTRUCTION DOCUMENTS. ONE COPY MUST BE A FULL SIZE COPY (24 X 36 MAXIMUM) TO SCALE, AND ONE COPY MUST BE NO LARGER THAN 11 X 17 INCHES. ALL REDUCED COPIES MUST BE FULLY LEGIBLE AND HAVE A GRAPHIC SCALE. REVERSED TEXT DRAWINGS WILL NOT BE ACCEPTED.

DESCRIBE THE OVERALL SCOPE OF THE WORK THE FOLLOWING ATTACHMENTS ARE PART OF THIS APPLICATION FORM: FIRE DEPARTMENT MINIMUM PLAN REVIEW REQUIREMENTS BUILDING DEPARTMENT LOCAL REQUIREMENTS FOR INSPECTION OF FIRE PROTECTION SYSTEMS FIRE ALARM PERMIT FEE SCHEDULE FIRE ALARM PERMIT FEE WORKSHEET PERMIT PROCESS FLOW CHART PERMITS ARE NOT TRANSFERABLE AS TO PERSON OR PLACE AND ARE NOT REFUNDABLE. ISSUANCE OF A PERMIT DOES NOT GUARANTEE COMPLIANCE WITH ANY CODE. PLAN REVIEWS NOTE ALL OBSERVED DEFECTS AND ARE SUBJECT TO FIELD CORRECTION. COMPLETED WORK MUST BE INSPECTED IMMEDIATELY. THE APPLICANT SHALL BE RESPONSIBLE FOR OBTAINING PERMITS AND INSPECTIONS AND PAYMENT OF FEES. IF WORK IS STARTED BEFORE A PERMIT IS ISSUED AN ADDITIONAL INVESTIGATIVE FEE WILL BE ASSESSED. SECTION 23a OF THE STATE CONSTRUCTION CODE ACT OF 1972, ACT 230 OF THE PUBLIC ACTS OF 1972, BEING SECTION 125.15321 OF THE MICHIGAN COMPILED LAWS, PROHIBITS A PERSON FROM CONSPIRING TO CIRCUMVENT THE LICENSING REQUIREMENTS OF THE STATE RELATING TO PERSONS WHO ARE TO PERFORM WORK ON A RESIDENTIAL BUILDING OR A RESIDENTIAL STRUCTURE. VIOLATORS OF SECTION 23a ARE SUBJECT TO CIVIL FINES. APPLICANT SIGNATURE: I HEREBY CERTIFY THAT I HAVE RECEIVED, READ AND UNDERSTAND THIS FORM AND THE ABOVE ATTACHMENTS AND THAT ALL INFORMATION PROVIDED HEREIN IS CORRECT AND TRUE TO THE BEST OF MY KNOWLEDGE. APPLICANT S SIGNATURE DATE DRIVERS LICENSE NUMBER DATE OF BIRTH

OFFICE USE ONLY FEES: PAID: Admin Fee CDD & FD: _$125.00 Permit #: Permit Fee: Date Issued: Elec. Insp: _$70.00 Issued by: Plan Review Fee: Contractor Registration: Investigative Fee: Other: TOTAL: OFFICE USE ONLY: APPROVED BY DATE COMMENTS: REV 01/12

INFORMATION REQUIRED FOR FIRE ALARM AMD FIRE SUPPRESSION PLAN REVIEWS Sprinkler System Submittals: *See NFPA 13 for a complete submittal list. Plans must be to scale and clearly show work to be done including a detailed scope of work. Plan must show the job name and address, building dimensions and total square feet. The specific type and quantity of sprinklers shall be provided on every page. Catalog cut sheets for all sprinklers, valves, etc. shall be included and highlighted. Fire hydrant flow test information shall be dated and less then 1 year old. Hydraulic calculations shall clearly show the friction loss for the backflow preventer and include a graph curve sheet. All hydraulic node points shall be clearly shown on the drawings. All ceiling information including soffits, heights, construction type, slope, etc. shall be shown and noted with cross section detailed on the plans. Specific code sections and storage information shall be provided for all design densities over Ordinary Group II. All plans shall have the contractors name, address, phone and fax number. Provide a scaled site plan clearly showing the building fire department connection location and fire hydrant locations. Fire Alarm System Submittals: *See NFPA 72 for a complete submittal list. Plans shall be to scale and include a scope of work outlining details of the project. Plans must show job name and address, building dimensions and total square feet. The square foot area of the building shall be noted on the plans. Catalog cut sheets shall be provided and highlighted for all components to be installed. Specific details shall be provided regarding the offsite monitoring of the system including type of transmission means and name and location of receiving station. All wiring information shall be shown on the plans including size, type, and all point to point wire runs. Complete battery back up calculations shall be provided that clearly note battery size to be provided. Voltage drop calculations for notification devices shall be provided. All plans shall have the contractors name, address, and phone number. Kitchen Hood Wet Chemical System Submittals: *See NFPA 17A for a complete submittal list. Plans shall include exact hood, duct, pipe and appliance dimensions. Plans must show job name and address, building dimensions and total square feet. Catalog cut sheets shall be provided for all nozzles and equipment to be used. The tank size and flow point count shall be noted on the plans. All plans shall have the contractors name, address, and phone number. A plan view of the kitchen shall show the hood, tank, and pull station locations. The plans shall clearly show the type of nozzles to be used and show the mounting height, and aiming point for each. Kitchen Hood Mechanical System Submittals: *See NFPA 96/mechanical code for a complete submittal list. Plans shall include complete hood, duct and mounting dimensions. Plan must show job name and address. Plans shall include a roof detail showing the exhaust fans and all equipment within 15'. Specific information and manufacturers UL listing shall be provided for all hoods calculated for other than code requirements. Complete calculations shall be shown for both the CFM and FPM used in sizing the exhaust duct and fan. All plans shall have the contractors name, address, and phone number.

LOCAL REQUIREMENTS FOR INSPECTION OF FIRE PROTECTION SYSTEMS 1. All hydrostatic and alarm tests must be scheduled directly with the Fire Department at 248-588- 3605, with 48 hours notice. That office will coordinate with the Building Department. Mechanical piping inspections must be scheduled in the normal manor by calling 248.583.0831. 2. The riser must be installed in accordance with the City approved piping detail. The piping inspection by the Mechanical Inspector must be complete and approved. 3. The suppression system (including required alarms) must be complete and fully operational. We do not witness partial tests. 4. An inspectors test must be installed on each riser and reduced to the smallest size head in service on that riser. Wherever possible, the preferred location is at the farthest point from the water source 5. Spare heads and wrenches must be in place. 6. All fire department connections must be a five inch (5 ) Storz connector. There shall be a minimum of ten feet of separation between the F.D. connection and any gas or electric service equipment. All new or modified systems must comply with this requirement. 7. All new or modified systems must comply and conform to current backflow/cross connection rules. If modification of the riser is required the riser must conform to the Madison heights Riser Diagram. 8. Dry pipe systems must be tested for timed operation as well as wet or dry pressure. 9. Madison Heights Building Department Local Requirement: The State of Michigan Bureau of Construction Codes has determined that the alarm equipment required to monitor a fire suppression system is NOT an fire alarm under the code and as such, notification devices are NOT required in the occupied spaces of a building. The Madison Heights Building Department and the Madison Heights Fire Department STRONGLY recommends that notification devices be installed in all buildings in sufficient numbers to alert all the occupants of the activation of the fire suppression system. Whether the activation is from a fire, or another activity such as damage or freezing, the water flowing from these systems can cause severe building damage and personal injury in a matter of minutes. Immediate notification to building occupants is necessary to protect their safety.

CITY OF MADISON HEIGHTS FIRE SUPPRESSION AND FIRE ALARM PERMIT PROCESS APPLICANT FILES APPLICATION AT COMMUNITY DEVELOPMENT DEPARTMENT LOCATED IN CITY HALL FIRE SUPPRESSION ALARM PLAN IS REVIEWED BY THE BUILDING AND MECHANICAL INSPECTORS PLAN IS REVIEWED BY THE ELECTRICAL INSPECTOR APPROVED NOT APPROVED NOT APPROVED APPROVED SUPPRESSION ALARM REVIEW COMMENTS ARE SENT TO APPLICANT, PLAN IS CORRECTED AND RE- SUBMITTED APPLICATION IS SENT TO THE FD AND REVIEWED BY THE FIRE PREVENTION BUREAU OR THEIR CONSULTANT APPROVED NOT APPROVED Legend: Applicant Building Division CDD Fire Prevention Bureau PLAN IS RETURNED TO THE BUILDING DIVISION AND THE PERMIT IS ISSUED. (NOTE: ANY CORRECTIONS REQUIRED BY THE FD REVIEW AFFECTING THE BUILDING, MECHANICAL OR ELECTRICAL CODES ARE REVIEWED BY THE BUILDING DEPARTMENT. ANY CHANGES REQUIRED BY THAT DEPARTMENT AS A RESULT OF THE FD REVIEW MUST BE CORRECTED AND RESUBMITTED PRIOR TO THE PERMIT BEING ISSUED.) REVIEW COMMENTS ARE SENT TO APPLICANT, PLAN IS CORRECTED AND RE- SUBMITTED APPLICANT COMPLETES ALL WORK AND OBTAINS AND PASSES ALL REQUIRED MECHANICAL AND ELECTRICAL INSPECTIONS AND SYSTEM TESTS

CITY OF MADISON HEIGHTS COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION (248) 583-0831 FIRE DEPARTMENT FIRE PREVENTION BUREAU (248) 588-3605 1. FEE SCHEDULES: www.madison-heights.org FIRE ALARM PERMIT FEES AND POLICIES Administration Fee: Electrical Inspection - CDD Re-Inspection Fee: $125.00 (Required on all permits) $70.00 each (One required on all permits) $35.00 each inspection (Charged on all failed inspections by CDD and FD. Must be paid prior to re-inspection. FD Plan Review Fees: Minimum Fee: $150.00 Number of Alarm Devices: Permit Fee: 1 to 10 $200.00 11 to 25 $290.00 26 to 50 $435.00 51 to 75 $700.00 76 to 100 $850.00 101 to 125 $1020.00 Over 125 $1020.00 plus $5.70 per additional device over 125 Rush Plan Reviews: Add 100% to base fee.* 1 to 3 days turn around. * Add $25 for overnight plan return Contractor Registration Fee: $15.00 for term of license. (Requires valid State license, drivers license, workman's compensation information, and a federal I.D. number. Initial registration must be done in person by license holder.) 2. POLICIES: All applications are received at the Community Development Department. All plan reviews include one initial and one follow-up review. Additional fees will be charged for plan reviews past one follow-up review. Electrical inspections are scheduled through the Building Department at (248) 583-0831. Alarm and other system tests are scheduled with the Fire Prevention Bureau at (248) 588-3605. All tests and inspections that are not approved require payment of a $30.00 re-inspection fee to both Departments prior to re-inspection. Rev. 05/02/17

FIRE ALARM FEE WORKSHEET 05/02/17 FIRE ALARM PERMIT FEE COMPUTATION WORKSHEET (SUBMIT WITH PERMIT APPLICATION) FEE ITEM: DESCRIPTION: FEE: # OF ITEMS: TOTAL: Admin. Fee Building Division & Fire $125.00 1 $125.00 Administration Fee (Req.) Plan Review Fee In-House Plan Review $150.00 1 $150.00 Electrical Insp. Building Division Electrical Inspection $70.00 1 $70.00 (Req.) Additional Mechanical Inspection(s) $70.00 F.D. Permit Fees Number of Devices Base Fee: 1 to 10 $200.00 11 to 25 $290.00 25 to 50 $435.00 51 to 75 $700.00 75 to 100 $850.00 100 to 125 $1020.00 Over 125 $1020.00 plus $5.70 per device over 125 Rush Review *Add $25 for overnight plan return Add 100% to base fee.* 1 to 3 days turn around. Other: Contractor Registration $15.00 TOTALS: 1