PS12 12 day Autotimer water softener

Similar documents
Effective April 14. Installation Date:..

Installer & User Guide Effective February 2013

Installer & User Guide Effective January 2013

Installer & User Guide Effective January 2017

MONARCH WATER INSTALLER & USER GUIDE. Effective January The Plumbsoft Water Softeners with the 7 & 2 year Guarantee

What to expect from your water softener

Water Softener Installation Guide Effective for all Softeners from our Range

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

INSTALLATION AND QUICK COMMISSIONING INSTRUCTIONS EWC WARM WATER TIME CLOCK WATER SOFTENERS

~-ti-=t"- MODELS. !'..,.~-_ ~ _,, -:~.. l- l.. -l > _ {.- ~ t "',, j ~ t. t- -,l-~ -+ _ "'l.,.._

Installation, Commissioning, Programming & User Information For Water Softener Models: SF 10 Litre Timed & SF 12 Litre Metered

2020c WATER SOFTENER INSTALLATION INSTRUCTIONS. visit

Water Softener. Operating Manual

NOT EVERYTHING IN LIFE IS COMPLICATED.

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

CONTENTS. Page. Contents. Introduction, features and benefits. PART ONE Overview of the water softening process 4-5

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

MONARCH SCALEOUT MONARCH WATER

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Water Softener VSOFT 15. Fitting and operating instructions. Changes of technical details are reserved. VSOFT / BWT UK Limited F R E E H O M E

1. BYPASS 7. WATER OUTLET 2. VALVE HOUSING 8. BLENDING REGULATOR 3. RESIN TANK 9. HARDNESS REGULATOR 4. SALT BIN 10.

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Tel: Fax:

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

WS1 Softener Installation & Start-Up Guide

ACN Home Security in collaboration with Verisure UK. Market & Product Overview

Cabinet Non-Electric Water Softener

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

1. BYPASS 7. WATER OUTLET 2. VALVE HOUSING 8. BLENDING REGULATOR 3. RESIN TANK 9. HARDNESS REGULATOR CONTAINER FOR 4.

BWT WS Range Water Softener

Inta City Concealed Shower Mixing Valve CT80010CP

Clean Water Made Easy

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

DUPLEX COMPACT. 11. CONNECTIONS (1/2",3/4, 1") BRINE VALVE 5. (floater)

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

CWS Plus Sediment Filter Installation & Start Up Guide

INSTALLATION GUIDE. soft duomatik evoline

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

Kinetico 2060f OD Sulfur Guard Installation Instructions

WF140 Freestanding Dishwasher

INSTALLATION GUIDE. soft monomatik hotwater

WC141 Integrated Dishwasher Installation, Use and Maintenance

60W Multi PIR Bulkhead

Alpha CombiMax 350 and 600

Clean Water Made Easy

INSTALLATION GUIDE. soft duomatik evoline

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

MW401 Integrated Dishwasher

OPERATION AND MAINTENANCE MANUAL

OWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters

IMPORTANT SAFETY INFORMATION READ ALL...

Installation Instructions

Fleck 5600 Carbon Filter Installation & Start Up Guide

Clean Water Made Easy

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Carmen. Operating Instructions. 1

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Owner's Manual. WS Series. Water Softener

MW402 Integrated Dishwasher

2.0 HIGH CAPACITY SIMPLEX WATER SOFTENER INSTALLATION AND OPERATIONS MANUAL

Installation and Operations Manual

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

USER GUIDE VOGUE MAX SYSTEM

For use with approved Bathstore head kits. Installation guide. Viso Digital installation instructions Page 1

18W Round LED Wall/Ceiling Light with Microwave Sensor

The Professional s Choice

Clean Water Made Easy

Fleck 7000 Sediment Filter Installation & Start-Up Guide

360 Surface Mount Ceiling PIR Light Controller

12W Round LED Wall/Ceiling Light with Microwave Sensor

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

PULSACOIL A CLASS USER GUIDE. TEL:

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Bx OVEN SET UP AND OPERATION OF OVEN AND CONDENSER UNIT (IF FITTED) CLASSIC

Inta City Shower Mixing Valve CT20010CP

WS1 Greensand Installation & Start Up Guide

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

Fleck 2510 SXT Catalox Installation & Start Up Guide

5W LED Energy Saver PIR Bulkhead

Flomate Mains Boost Pump Installation & Maintenance Instructions

Metermatic Water Softener. Operation Manual

Baxi Maxflow Combi FS

Fleck 2510 Sediment Filter Installation & Start-Up Guide

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Deluge Shower Mixing Valve 10045CP

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

WC370 Integrated Intelligent dishwasher Manual for Installation, Use and Maintenance

Model NFF Iron, Manganese, Hydrogen Sulfide Reduction

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

High Frequency Sensor

500 SERIES FOOD WASTE DISPOSERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR 523 SERIES SERIES SERIES 17

Intatherm Safe Touch Basin Tap IT1008CP

Installation, Operating and Maintenance Guide

Enzo Concealed Shower Mixing Valve

THE OXYVENT TANK. Patent No. EP INSTALLATION MANUAL. This Manual is to be left with owner. TUV Certificate of Design Approval

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

Transcription:

PS12 12 day Autotimer water softener

PLUMBSOFT PS12 AUTOTIMER WATER SOFTENER PROGRAMMING & INSTALLATION INSTRUCTIONS Effective October 2013. Thank you for choosing our water softener. Please read the following carefully, which if followed correctly, should ensure the installation is trouble free. A. PLANNING THE INSTALLATION Always observe the water byelaws. Ensure there is only one rising main, that you have allowed space for access to the unit for salt filling and for any possible maintenance in the future. Check the water pressure; locate the rising main, a drain facility and a power supply. B. SITING THE SOFTENER Fig 1 Where possible, this should be close to the rising main. Take care to allow hard water take off points for a drinking water facility and/also an outside tap. The distance between the softener and the drain should be as short as possible. Ensure that both the drain and the overflow are not subject to freezing or over 120 degrees F. If siting the softener within a kitchen cupboard ensure that the base is adequately supported. If the softener is being installed in your loft, 1 st, 2 nd floor etc, it is recommended to house the softener within a 25-gallon plastic tank and insulate well. The overflow on the plastic tank should be below the overflow of the softener and a minimum of ¾ in size. Failure to install the softener in a suitable tank will void the Guarantee C. NON-RETURN VALVE In single dwellings a single check valve should be fitted. All other applications require a double check valve. D. DRINKING WATER FACILITY Fig 1. In compliance with U.K. Water Regulations a tap for drinking water purposes should be left on the hard water supply. E. MATERIAL CHECK LIST The softener includes an installation kit for a conventional system (tanks in roof). For Combi boilers you will need additional Maxflow Hoses. For a pressurised system (22mm pipe work) you will need the additional PSK that includes Maxflows. F. WATER PRESSURE TEST It is IMPORTANT that a pressure check is carried out. Low and high pressure can result in either damage to, or failure of the softener. If daytime static water pressure* exceeds 3.5 bar (50psi) a pressure limiter should be fitted. Minimum dynamic pressure must exceed 1.4 bar. If in any doubt please call us on 01986 784 759. *50psi daytime pressure can reach over 70psi nighttime pressure! J. FAST FLOW DRAIN KIT Where a drain is not readily available. A Fast Flow Drain Kit may be used and is available from us. Ref: FFDK Please note that the Fast Flow Drain Kit cannot be used on overflow connections. K. OVERFLOW CONNECTION The hose for the overflow should be cut from the drain hose provided. The overflow connection is the ½ hose spigot on the rear of the cabinet. No clip is required. The overflow must be run downhill through an outside wall without kinks or restriction. It is recommended the overflow hose be run to over an outside gully whenever possible with a clear 20mm air gap at the end of the hose. A 22mm copper protective sleeve through the outside wall will help prevent kinking of the hose. The overflow hose can be cut off the drain hose for use. L. TEST INSTALLATION FOR LEAKS Close Inlet and Outlet valves to the softener and open Bypass valve. Open mains stopcock slowly and flush the new pipe work and connections via an adjacent mains tap. Ensure the tap used is not a hard water tap. Check all connections for leaks. M. OBTAIN YOUR WATER HARDNESS These instructions apply to the enclosed test kit only. Run hard water for approx. 1 minute and rinse the test tube well. Fill the test tube up to the 10ml level. Add 2 drops of the dark solution and mix gently. If the water sample contains hardness it will turn red. Add the dark solution in batches of 5 drops, holding the dropper bottle at 45 degrees. Mix gently after each 5 drops. Count the drops needed until the colour of the sample in the test tube changes from a dark red to a dark blue/green. You will need this figure for the Settings Chart. Fig 1. G. INSTALL BYPASS VALVES & NON-RETURN VALVE Form an installation as per Fig 1. H. INLET & OUTLET CONNECTIONS Fig 3. Using the hoses provided connect the braided hoses to the in/out connections on the sides of the softener it is recommended to use the elbow connections here. Under no circumstances use washing machines hoses or plumb the softener in solid copper pipe. I. DRAIN CONNECTION Fig 3. The drain hose is already connected to the drain connection for you. Run the drain hose to either an upstand or an outside drain. A minimum air gap of 20mm should exist at the end of the drain line. Softened water will have no adverse effect on a septic tank. If you need to extend the drain hose this can be done by connecting to a 15mm copper tube for a max run of 8 metres with a minimum daytime pressure of 40 psi. Ensure that the drain hose is adequately fixed to the copper pipe. The drain hose must not dip or be kinked in any way as this will lead to an overflow of the machine. UPHILL? The white flexible drain hose can run uphill internally for a maximum of 3 feet with a minimum water pressure of 40 psi.

Step by Step guide for assistance Remove top cover by undoing 2no screws as shown. Rear view showing Inlet (L) & Outlet (R) connections Pre-connected Drain hose. Front view of Electro Mechanical Timer Plan view of Inlet (L) and Outlet (R) connections. Flow direction arrow clearly marked on both Inlet & Outlet connections

Programming the Electro Mechanical Timer The electro-mechanical timer is fully automatic. It uses a 12-day skipper wheel to activate the regeneration. Fig 1. Fig 2. Time of Regeneration This has been pre-set to 2am. If Economy 7 electricity is used during the night, ensure that appliances do not use water between 2 and 3.30am. Alternatively, you can alter the regeneration time by loosening the centre screw then turn the REGEN TIME wheel to the appropriate time and then retighten screw. Time of Day Turn the timer knob (k) anticlockwise until the correct time of day on the clock appears in the TIME OF DAY window. Days of Regeneration With all skipper pins (E) pulled out, push in the pins as determined by the chart and details below relevant to your installation. Settings Chart Family Size Up to 30 drops 31-40 drops 41-50 drops 1 person A B C 2 people C D D 3 people D E E 4 people E E E Pin Settings A = push in pins 1 & 7 D = push in pins 1, 3, 5, 7, 9 & 11 B = push in pins 1, 5 & 9 E = push in all pins or consider larger softener with C = push in pins 1, 4, 7 & 10 greater capacity/less frequent regenerations. Finalise Commissioning 1. Fill softener with tablet salt only, before you turn on the water supply. Please advise customer to keep the softener full at all times using tablet salt see USER MAINTENANCE below 2. Close Bypass valve, then slowly open both Inlet and Outlet valve and allow softener to pressurise and salt chamber to fill approx 10 minutes. 3. Check for leaks. 4. Connect plug top and turn on power. USER MAINTENANCE The softener requires minimal maintenance. Simply keep the unit topped up with salt. The softener will require topping up when or before you see water. We recommend that the softener be topped up twice a week. Never let the salt go below the water level. USE TABLET SALT IN EVERY INSTANCE. Water softener guarantee becomes void if granular salt is used! Suppliers to H.M. the Queens Estate at Sandringham Monarch Water, Halesworth Road, Bramfield, Suffolk, IP19 9HS Tel: 01986 784759 Fax: 01986 784769 Email: sales@monarchwater.co.uk Web: www.monarchwater.co.uk

PLUMBSOFT WATER SOFTENER GUARANTEE Effective August 2011 This water softener is fully covered by 5 year parts and 2 years labour guarantee for installation within the hard water regions of mainland England as detailed on Monarchs National Service Coverage List, from date of purchase. Full details are available on request. Installations outside this area are automatically covered by 5 year parts only exchange warranty. PLEASE NOTE - This guarantee has the following conditions, and is not covered by the following. 1. Damage caused by high water pressure, we strongly recommend a 5bar water pressure limiting valve on the inlet to your water supply, where daytime water pressure exceeds a static pressure of 50 psi (3.5 bar) 2. This water softener is suitable for a mains water supply only. Under no circumstances install this softener on a private water supply unless it is fully protected against iron, sediment build up etc in the water. 3. Damage caused by a dirty mains water supply. The installation of an H1034 c/w APSR Debris Filter cost 53.82 inc VAT & postage on the supply to your softener cancels this clause. The majority of debris in water is caused by local authority work on the water main. If notified in advance, by your local water authority, please put your softener onto bypass, see Fig 1on Programming & Installation Instructions. For Bypass: Close both Inlet & Outlet valves, and open Bypass valve. For Normal Service: Open both Inlet & Outlet valves, and close Bypass valve. Details with diagrams are available on our web site: www.monarchwater.co.uk/htm/home/bypassing.htm 4. Callouts due to incorrect installation. If you have any queries when installing your softener, please call us on 01986 784759. 5. The wrong type of salt used. NOTE: In all cases use TABLET SALT ONLY. (The Solo range can use Kinetico Block Salt as an alternative to Tablet Salt) 6. The use of any other hoses than those provided. Under no circumstances use washing machine hoses. 7. The build up of salt fines in the bottom of the salt compartment. 8. The effect of aggressive water, the degradation and/or blinding of resin and/or chlorine attack on resin. 9. Under no circumstances plumb in the softener in solid copper. 10. The installation kit is only covered by the OEM twelve-month parts exchange warranty only. 11. Compensation as a result of damage caused by; or incorrect installation of the water softener. In the unlikely event of a fault developing, put the softener on to Bypass, see 3 above ref For Bypass until an engineer calls. THE ABOVE DOES NOT AFFECT YOUR STATUTORY RIGHTS SERVICE CARE The manufacturer of your water softener includes 45+ years of manufacturing experience, to give you a water softener that is arguably the most reliable on the market today. One of the aspects incorporated into the manufacture of your softener is Prevention is better then cure. To these ends, Monarch strongly recommends a service every 2 years from date of installation, to ensure the continued excellent operating efficiency you will come to expect. We will of course inform you when this small service is due and arrange a convenient time for our engineer to call. Therefore please ensure that your guarantee card is returned once installation is complete Suppliers to H.M. the Queens Estate at Sandringham Monarch Water, Halesworth Road, Bramfield, Suffolk, IP19 9HS Tel: 01986 784759 Fax: 01986 784769 Email: sales@monarchwater.co.uk Web: www.monarchwater.co.uk

Sales and Service Coverage Areas Agreement Effective 1st November 2010. The below postcodes (see map below) are automatically covered by a parts and labour warranty as set out in the relevant sales brochure for the individual model/range. BA BH BN BS CB CM CO CT DT GU HP IP LONDON as inset LU ME MK NN NR OX PE PO RG RH SG SL SN SO SP SS TN IMPORTANT Water softeners sold outside the above counties are to be covered strictly by a parts only exchange warranty as determined by the model/range of softeners i.e. Plumbsoft with 5 years parts only. All parts sent back to Monarch are at the expense of the sending parties. All repaired or replaced items will be returned to the sender on a no charge basis whilst covered by the parts exchange guarantee. Once the parts exchange guarantee has expired, Monarch reserves the right to make a charge for any postage/delivery, labour and parts charges that is deemed necessary. Monarch will endeavour to keep these charges at the lowest cost whenever possible. Suppliers to H.M. the Queens Estate at Sandringham Monarch Water, Halesworth Road, Bramfield, Suffolk, IP19 9HS Tel: 01986 784759 Fax: 01986 784769 Email: sales@monarchwater.co.uk Web: www.monarchwater.co.uk