PRESSURE DEW POINT MEASUREMENT WITH CCC*-SENSOR

Similar documents
Meteorology 432. Hygrometry Spring 2013

DP 300 mobile dew point instrument

Hygrometry. The art or science of humidity observation

Humidity Measurement Technology

UNIT - 3 Refrigeration and Air - Conditioning

Humidity Generation and Humidity Measurement The Complete Guide

Chapter 9: The basics of air preparation

Chapter 5: Atmospheric Moisture

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

3.4 Humidity. Types of instruments

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Moisture in the Atmosphere. GEOG/ENST 2331 Lecture 9 Ahrens: Chapter 4

White paper Compressed air drying

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Thermodynamics II Chapter 6 Mixtures & Psychrometry

Determination of the enthalpy of vaporization of liquids

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

Water in the Atmosphere

Atmospheric Moisture: Relative Humidity and Dew Point

IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone:

Humidity Measurement Technology pros & cons. Helping you make a better measurement.

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

Using the Model 1500 Portable Chilled Mirror Hygrometer

2016 Annual Conference

Refrigeration dryers DW 2-504

Thermo-physical properties found on most psychrometric charts

Humidity Measurement Technology Pros & Cons. Helping you make a better measurement.

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Chapter 8 Balances on Nonreactive Processes PSYCHROMETRIC CHART

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

(Refer Slide Time: 00:00:40 min)

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

SIR C.R.REDDY COLLEGE OF ENGINEERING, ELURU DEPARTMENT OF MECHANICAL ENGINEERING ETD-II. Model Short Answer Questions And Answers

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION PROPERTIES OF THE RSES CALCULATOR

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

Chapter 9. Refrigeration and Liquefaction

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

The Refrigeration Cycle

Using the DewTrak II Dew Point/ Humidity Transmitter

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

A Treatise on Liquid Subcooling

The Refrigeration Cycle

SIMRAD GD10PE IR GAS DETECTOR

Refrigeration dryers DW 2-504

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Heat pump supplemental heating system for motor vehicles

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

RK Carbon Monoxide Transmitter Operator s Manual

Induction Billet Heaters with Enthalpy Controlled Zone Heating

GE General Eastern Instruments

HICOSYS FOR PROCESS CONTROL OF SPRAY DRYERS

Optimizing Strategy for Boiler Drum Level Control

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Humidity An excuse for the 80s

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Refrigerant Glide and Effect on Performances Declaration

METPOINT OCV. e. g. SAFE PROCESS THROUGH MONITORING. FOR CHALLENGING COMPRESSED-AIR APPLICATIONS Pharmaceuticals. Food Chemical Coating

Pressure Enthalpy Charts

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Membrane Dryers KMM Series

Summary: thermal analysis, CFD simulations. - Enrico Da Riva - CERN (EN/CV/PJ) Workshop on SiPM cooling for Fiber Tracker, 17 October 2013

Thermo Scientific Model 1160 Principle of Operation

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Global Warming and the Hydrological Cycle

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Dew-Point Transmitters and Instruments

CE311 Fall 2016 Mid-Term Exam 1

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

: REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE

HVAC (Heating, Ventilating, and Air Conditioning)

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

The Basics - B Practical Psychrometrics. Jerry Cohen President Jacco & Assoc.

Adsorption Dryers. AD 7 to 1300

PLEASE READ AND FOLLOW THESE INSTRUCTIONS

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING

Chapter 4 Compressors Overview & System Annual Power Consumption

OURSE TITLE : MASS TRANSFER OPERATIONS 1 COURSE CODE : 5071 COURSE CATEGORY : A PERIODS/ WEEK : 4 PERIODS/ SEMESTER : 52 CREDIT : 4 TIME SCHEDULE

UNIT-III PSYCHROMETRY. Though there are many psychometric terms, yet the following are important from the subject point of view :

Humidity sensors. Behavior in different environments. Supervisor: Vaclav Vacek Collaborators: Martin Doubek, Martin Janda and Michal Vitek 28.9.

RK Carbon Monoxide Transmitter Operator s Manual

Transcription:

PRESSURE DEW POINT EASUREENT WITH CCC*-SENSOR A. Steinke*, B. arch*, B. Prümm**, H. Hansch*** * CiS Institut für ikrosensorik ggmbh, D-99097 Erfurt, Germany ** PRÜ Feuchtemeßtechnik, D-41748 Viersen, Germany *** IL etronic Sensortechnik GmbH, D-98693 Ilmenau ABSTRACT: Humidity in compressed air is one of the most important problems in industrial and non industrial processes. The compressed air contains humidity despite of the drying process realized by the refrigeration dryer. The reason for that are located in the uncompleted separation process or in leaks along the compressed air pipes. For reasons of the energy and quality management a multiplicity of measurement principles has been developed for this application. But these technical and economical demands require more and more humidity measurement sensors with higher accuracy and long term stability. The best solution would be a direct and absolute humidity measurement system. It can be stated generally that the dew point principle is a (absolute measurement of humidity) favourable solution for such problems due to the measurement at the equilibrium state of condensation and evaporation. The developed monolithic integrated CCC*-dew point sensor bases on this thermodynamic principle and utilizes as a typical microsystem the cost advantages of the batch processes. This paper describes the most innovative CCC*- dew point sensor which is specified for the measurement of the pressure dew point temperature. Keywords: Humidity, Dew Point, Compressed Air 1 INTRODUCTION Compressed air is a compressed mixture of several gases like Nitrogen, Oxygen, Carbon dioxide, Hydrocarbon and many other trace gases. Besides such gases compressed air contains foreign substances like water, dust and oil. An air dryer is normally necessary to reduce the content of water. In such a case the absolute content of water has to be reduced to guarantee good conditions for technical processes. In case of higher humidity several damages or other disadvantages can happen. Condensed water causes rust within the pipe or in valves and reduces the long term stability. Not-airtight valves cause leaks and an endangering of the environment. In such pneumatic systems moisture in combination with the contaminations like oil reduces precision and disturbs control mechanisms. The costs for maintenance and service are increasing considerably. based painting processes and powder coating technologies use for example the compressed air as an active gas medium. The amount of water determines the percentage of water within the whole mixtured gases. Depending on the guarantee of the accuracy and the guarantee of the required water content in (compressed) air the quality of the process and the quality of the final product is more and less in good quality. oisture can contaminate the product followed by any chemical reactions. To avoid such disadvantages the refrigeration dryers are able to remove water vapor down to a pressure dew point temperature of about 2 C. In case of these refrigeration dryers compressed air passes the air-air-exchanger (Figure 1). In the following air-heat exchanger the air temperature of the compressed air is reduced to the required dew point temperature. The heat is removed from the compressed air by evaporation of the cooling medium. The cooled air passes through a separator. This separator discharges the water drops from the air. This air is heated up again by passing the airair-exchanger contacting the incoming hot air. Defect separators (1d), defects of the pipes (2) or other events after maintenance (3) cause considerable deviation of the required pressure dew point temperature. Due to this fact there can be stated a loss of quality of the product and technology. easurement of the pressure dew point temperature at the marked points (see Figure 1) is the best way to avoid any unwished problems. *Condensate controlled capacitance according to HEINZE

Fridge Dryer Transport of gases User of compressed air 1a 1b 1c 2 3 1d 1a 1b 1c 1d air-air-heat exchange air-heat exchange fridge machine separator measuring point Valves connection Painting process eteorological equipment Drying process Storage Figure 1. Scheme of drying, transport and using of the compressed air 2 REALIZATION OF THE REQUIRED EASUREENT SYSTE FOR ABSOLUTE HUIDITY The maximum content of water (g/m 3 ) in air depends on the air temperature. In case of a defined air pressure and a defined absolute humidity the air is able to take in water until a temperature sink. Below this limited temperature liquid water condense and flow away. This limited temperature is named as dew point temperature. The measurement of humidity is actually the measurement of the partial pressure of the water vapor component of a mixture of gases. One of the most common ways of measuring this partial pressure is by measuring the condensation temperature of the water vapor component of the gas known as the dew point temperature. There is a one to one correspondence between dew point temperature and water vapor partial pressure. Vapor Pressure solid liquid vaporized Tripelpoint Figure 2. vapor pressure curve Sublimation Temperature

The agnus formula describes the connection between water vapor pressure and temperature /2/ with the saturated water vapor pressure e w = e ws exp (a w t F )/(b w +t F ) (1) e ws = m wdmax R d T/V (2) The temperature in the point on the water vapor pressure curve (Figure 2) where the state of saturation is reached. is the dew point temperature. Since water vapor is found in gas mixtures, it behaves in accordance to the gas laws and exerts a partial pressure in a gas mixture per Dalton`s law. According to Dalton`s law is the total pressure of a gas mixture equal to the sum of the partial pressures of the component gases. If the total pressure is increased the partial pressure increased by the same amount. Because water vapor pressure is a function of dew point temperature, when total pressure is increased the dew point increases. As that pressure goes down, the dew point reduces (Figure 3). For calculation of dew point temperature at pressure p a a dew point temperature t d at pressure p a can be converted in a dew point temperature t d1 at a pressure p a1 by the following equation: t d + ((b w +t d )/a w ) ln(p a1 /p a ) t d1 = -------------------------------------- 1 ((b w +t d )/(a w b w ))ln(p a1 /p a ) x/g/kg 100 1 bar 10 2 bar 1-20 0 20 40 60 80 td/ C Figure 3. Dew point at different overall air 3 EASUREENT PRINCIPLE OF THE PRESSURE DEW POINT TEPERATURE The best and simplest way to measure the absolute humidity is to use a dew point hygrometer. The principle can be explained by using the water vapor curve. These dew point hygrometers work at the equilibrium state of condensation and evaporation. Therefore it is a favourable solution for such problems where accuracy and direct measurement of absolute humidity is required. Figure 4 shows a systematic /1/ which presents both physical methods for measurement of humidity - the thermodynamical equilibrium of energy between medium and sensors and absorption of energy by the water mass of medium at transmission. Besides the most expensive dew point mirror hygrometers the CCC* monolithic integrated sensor is based on thermodynamic principle of condensation and evaporation too and utilizes the cost advantages of the microelectronic batch processes.

The sensor system consists of the sensor chip, the cooling element and the signalprocessing for the evaluation of the condensed water mass and for the measurement of the temperature of the water drops. The dew point detector is located on the surface of the silicon chip formed as a stray field capacity and is connected with an integrated capacity-frequency converter. The detection area is cooled down by the cooling element. When water vapor condenses at the chip surface the dew point is reached. At the moment of dewing the stray field capacity is changing and so does the VCOfrequency (integrated signal preprocessor). In the same moment the temperature of the water drops is measured by an integrated monolithic temperature sensor. The signal processing (controller) guarantees a constant mass of water on the chip surface at the moment of dew point temperature measurement. The physical principle is the same used for the dew point mirror. Figure 5 shows the principle of the CCC*-dew point sensor system. Figure 4. Overview on the physical methods for measurement of humidity /1/ 4-20 ma sensor- environment interface integrated signal preprocessor Sensor area incl. - detection system - transducer controller mounting plate heat sink cooling element Figure 5. Principle of the CCC*-dew point sensor system (dimension of the sensor: 4 x 2 x 0,5mm 3 ). The dynamic behaviour regarding the detection system is very simple. After reaching the thermodynamical equilibrium a constant water mass exists on this surface like shown in Figure 6. If the humidity of the surrounded air increase more water condenses (see Figure 7). The origin state is reached by reducing the cooling performance.

Figure 6. Covering of the detection area with water drops regarding the thermodynamical equilibrium Figure 7. drops configuration after increasing of the humidity Based on this CCC*-principle different types of probes, compact transmitter, transmitter with separate probe and dew point meters were manufactured. Probes for pressure dew point is one of the possible configuration beside such one for higher gas temperature for example /3/. The dew point measurement systems are traceable to PTB standards. All these probes and devices have been provided with CE declaration. Low cost versions consisting of dewing element only are available too. 4 SPECIAL ADVANTAGES OF THE CCC*-DEW POINT SENSOR In accordance to the features of absolute humidity sensors the CCC*-dew point sensor offers several advantages in case of industrial applications. Figure 8 presents the special advantages. Special advantages of the CCC*-dew point sensor easurement of pressure dew point, absolute humidity (g/m 3 ), mixing ratio (g/kg) with high accuracy Long term stability Fast responds High reproducibility in case of high humidity Direct comparison of dew point temperature and temperature of material Figure 8. Advantages of the CCC*- dew point sensor 5 SYBOLS R d gas constant T temperature /K V volume e water vapor pressure e F water vapor pressure of sensor e W water vapor pressure, saturation e WS water vapor pressure, saturation at 0 C m wdmax max. mass of water vapor, saturation p a t F t d a W b W pressure of air temperature of sensor dew point temperature constant factor constant factor

REFERENCES [1]Heinze,D.;Einheitliche mathematische Beschreibung von Gasfeuchtemeßverfahren, Technische Universität Ilmenau,1980 [2]Heinze,D.;Steinke,A.:Thermodynamische Grundlagen,Sensor 93, Kongreßband IV, S.119-127,Wunsdorf:ACS 1993 [3]Product information TP 11020, TTR 11045, TPS 11310/TTR 11610/CiS-Erfurt AUTHOR(S): Dipl.Ing.Arndt Steinke, Dipl.Chem.Barbara arch, CiS Institut für ikrosensorik Erfurt ggmbh, Haarbergstraße 61, D-99097 Erfurt, Germany, Phone 49(0) 361 42051 0, Fax +49 (0) 361 42051 13, email: ims@cismst.de; Dr.Ing.Bernhard Prümm, PRÜ Feuchtemeßtechnik, Helenenstraße 94, D-41748 Viersen, Germany, Phone/Fax +49 (0) 2162 30208, email: pruemm@surfmarkt,de; Dr.Ing.Horst Hansch, IL etronic Sensortechnik GmbH, Am Vogelherd 22, D- 98693 Ilmenau, Germany, Phone +49 (0) 3677 871841, FAX +49 (0) 3677 871842, email: horst.hansch@il-metronic.de