PORTABLE AFTERCOOLER MODEL CA-350 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL

Similar documents
Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Air Dryers & After Coolers Dry Land

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT***

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

Installation and Testing of Inverted Bucket Steam Traps Manual

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

Model OP155 Air Dryer

SFD. Suburban Filter Dryer. User Manual Installation Instructions

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

USER S OPERATING AND INSTRUCTION MANUAL

PNLDII-28 Condensate Drain Instruction Manual

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

THERMAL SYSTEMS, INC. Installation and Operation Manual

PORT700CF Portable Fume Collector

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

PULSE JET DE-ICER OPERATING MANUAL SETUP OPERATION MODEL PJDX-C (REV B) Mode Adjustment Knob WATER SERVICE LINE THAWER FLOW MODE PULSE MODE

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

15Hp/20Hp Deluxe Compressor-Dryer System

2001 Smith Eastern Corporation

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

OPERATING INSTRUCTIONS

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Owner s Manual Phoenix Aquadry TX 200

Desiccant Air Drying System

55-Gallon Dispenser Package

Installation Instructions PP-AS20 Anti-Scale System

Humidistat-Thermostat

INSTALLATION AND OPERATION INSTRUCTIONS

Compressed Air Dryers

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD

55-Gallon Dispenser Package

VSA Series Air Dryer. User s Guide

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

MODEL MW200 MODEL MW600 AIR DRYER

Instruction Manual. Super 88

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

AeroVent 1 Product Manual

OPERATING INSTRUCTIONS

Desiccant Air Drying System

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

CP-JR STILL WATER CHILLER SYSTEM DESCRIPTION

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Vertical Dryer Owner s Manual

Hot Dog Roller Grills

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

ACT Cartridge Dust Collector

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

IMPORTANT SAFETY INFORMATION

SELF-CONTAINED POWER MISTER

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Horizontal Bottle Cooler Installation and Operation Manual

Model Numbers MH-16-TTC / MH-32-TTC / MH-47-TTC

Sound Cover [ , , , ]

Quest PowerHeat HFC 100 Pro

Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS

Installation and Operating Instructions

Service Parts, Kits and Accessories

MRS-6 Maxi-Guard II. Model: C , 12, 13, 14 OPERATION SERVICE PARTS CARE. Revised 2/02

CL & CLG Clamp Mount Mixers

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ULTRA QUIET & OIL FREE

DRYAIRE DESICCANT SYSTEM MODEL 6760

Parts Manual Vermeer/McLaughlin V500LTHD Vacuum Machine Part #E (SERIAL # 5DHDLT _5DHDLT )

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Part No Revised: October 2004 BUN WARMER. Instruction Manual. Models:8018,8019,8117,8219,8170

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

BLASTMASTER 1600 CFM AIR DRYER

High Performance Oilless Residential Light Commercial. Product Leadership Training Service Reliability

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

Refrigerant Recovery Machine. Model No Operating Manual

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Corrosion Dry Air Pak

BIG BOOT COMBUSTION AIR KIT Model: CAS-2BB, CAS-2CB, CAS-2B375

INSTANT-FLOW C-MICRO WATER HEATER

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Transcription:

PORTABLE AFTERCOOLER MODEL CA-350 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL

Aftercooler Operation Manual.0 INTRODUCTION Suitable for most blasting applications, the Command Air 350 efficiently cools, filters and dries the hot moist air produced by air compressors. Built tough for portable applications, the Command Air 350 features self-purging automatic drains, robust steel frame and airless tires for easy mobility. APPLICATIONS: Dry Ice Cleaning Sand Blasting Soda Blasting Any other equipment requiring cool, dry air for operation. WARRANTY Command Air Aftercoolers are guaranteed to be free of defects in material and / or workmanship for two (2) Years from the date of shipment to the buyer. The warranty shall cover 00% of all parts and labor with the exception of misuse, abuse, or neglect. The warranty also does not cover consumable items such as filters, drains and separators. The manufacturer will at it s option repair, replace or issue credit for the value of any defective aftercooler. Failure to follow proper operation and maintenance procedures described in this manual may limit or void this warranty. Buyer accepts all responsibility for compliance with any / all Local, State and Federal Laws or Regulations including Regulations of Foreign Governments. No equipment shall be returned without a Return Authorization Number from our customer service department. Upon evaluation and determination of warranty, replacements or repairs will be sent to the buyer. If a replacement is needed immediately, a Purchase Order is required to cover the cost of the product until the warranty is determined. The warranty is limited to replacing any goods that are proved to be defective and the manufacturer in no event shall have any liability for paying incidental or consequential damages including and without limitation, damages resulting in personal or bodily injury or death, or damages to, or loss of use of any property. Notwithstanding any of these terms and conditions, the warranty set forth shall apply in connection with any sales of goods, services or design by the manufacturer and are in lieu of all warranties, express or implied, including warranties of merchantability and fitness for a particular purpose..2 SAFETY PRECAUTIONS As with all equipment using a high pressure air source, proper eye and ear protection, along protective gloves, are required while operating the aftercooler. Do not touch inlet piping without protective gloves, air coming in from the compressor can be extremely hot and could cause minor burns. Review this operation manual prior to operation to ensure proper setup and safety procedures are followed. Rev. 3/4/4 2

Aftercooler Operation Manual.3 MACHINE SPECIFICATIONS CA-350 Aftercooler Specifications: Pressure Rating: 230 psi Max inlet temperature: 250 F Flow Capacity: 233 SCFM @ 00 psi, 352 CFM @ 232 psi MAX Filtration: Coalescing grade 0 (.7 micron) Dimensions: 48 tall x 26.6 wide x 8.75 deep Weight: 80 lbs Inlet:.5 female NPT Outlet: female NPT Fan Motor Supply: 25 CFM @ 35 psi MAX 2.0 OPERATION. Connecting Air Supply and Equipment Supply Hose Fitting: Connect air supply hose fitting (not included) to the.5 female NPT fitting (Air In). Supply hose should be rated for the outlet pressure and temperature of your air compressor. A shorter hose is recommended, the aftercooler should be located as close to the compressor as possible. Outlet Hose Fitting: Connect the outlet hose fitting (not included) to the female NPT ball valve (Air Out). Connect the outlet hose to your equipment. An outlet valve is required on the air supply so the aftercooler can be isolated from the air pressure in case of emergency Full flow valves and fittings, along with hose whip checks are recommended Air Supply Inlet Air Motor Shutoff Air Outlet 2. Pressurizing the Aftercooler Always ensure all connections are secure and the outlet valve is closed prior to pressurizing, then activate your air compressor. Open the compressor outlet valve slowly to pressurize the aftercooler. 3 Rev. 3/4/4

Aftercooler Operation Manual 2.0 OPERATION (continued) 3. Air Motor Adjustment The fan motor will require adjustment based on the ambient temperature. In environments with a temperature of 80 F or higher, set the motor at 35 psi. In cold environments the fan can be adjusted very low or even at zero when it is near or below freezing. For most environments the fan motor should be set between 20 and 35 psi. Set the motor operating pressure by turning the knob on the air pressure regulator connected to the fan motor. Air pressure to the fan can be monitored on the gauge located behind the motor. 4. Pressurizing Blaster or Other Equipment (Air Out) Ensure the outlet connection on the aftercooler and the inlet connection on your equipment are secure. Open the aftercooler outlet valve slowly to pressurize your equipment. Equipment can be used immediately after pressurizing, the aftercooler will provide cooled and filtered air instantly, no warm up time is required. 5. Cooling Operation The outlet piping and hose from the aftercooler should be cool to the touch even after hours of operation. If it is hot or warm, increase the air motor pressure to reduce the air temperature. Do not touch inlet piping as air coming in from the compressor can be extremely hot and could cause minor burns. Water will automatically drain from the water separator (silver cylinder) on the back of the aftercooler. A drip pan is recommended for indoor use. The amount of water drainage will depend on temperature and humidity levels. To deactivate the aftercooler, first shut down your blasting equipment, then close the aftercooler outlet valve. Shut down the air compressor to depressurize the aftercooler. Rev. 3/4/4 4

Aftercooler Operation Manual 3.0 MAINTENANCE & PARTS DP Indicator Coalescing Filter Cooler Motor Water Separator Automatic Drain Pulse Drain Filter Drain Cooler Pulse Drain Coalescing Filter Check the differencial pressure (DP) indicator on the top of the coalescing filter periodically to view the status of the filter element. The indicator will show red when it is time to change the filter element. Water Separator The water separator is for the most part maintenance free, however it should be inspected for proper operation. If it is not separating moisture from the air it may need to be replaced or the drain may be clogged. Moisture Drains The four drains may be cleaned or replaced as needed. The automatic drain on the water separator will drain the most water. If it stops draining for an extended period of time, check for a clogged drain and clean. Cooler & Air Motor The air motor powering the cooler is oilless and should not require maintenance. The fan and vents on the cooler should be inspected regularly and will require cleaning when dirty. The fan unit may be cleaned with compressed air or a power washer. If power washing, be sure to spray the unit parallel to the direction of the fan blades in order to avoid damage. 5 Rev. 3/4/4

Aftercooler Components COMMAND AIR 250 SPARE PARTS DRAWING # OF 6 REVISED 0/05/4 TOP VIEW CAC2GA00 AHP-400-C CAC2F06 CAC2F035 CAC2FA250 AIR OUT FILTER ASSEMBLY DETAIL (CAC2AOF0) SEE DRAWING # 2 CAC2AOF06 CAC2AOF02 CAC2AOF07 AIR OUT CAC2AOF04 CAC2AOF05 CAC2AOF03 DRAWING #2 OF 6 AIR OUT FILTER ASSEMBLY DETAIL (CAC2AOF0) Rev. 3/4/4 6

Aftercooler Components DRAWING #3 OF 6 DRAWING #4 OF 6 CAC2AI0 AIR IN REVISED 0/05/4 LEFT SIDE VIEW REVISED 0/05/4 LEFT SIDE VIEW CAC2FBA033 CAC2F030 CAC2F038 CAC2AOF08 CAC2F06 CAC2AOF07 AIR OUT CAC2HA03 CAC2GA00 CAC2HA04 CAC2F060 CAC2F059A CAC2F03 IB0B26 CAC2AO0 CAC2F064 7 Rev. 3/4/4

Aftercooler Components DRAWING #5 OF 6 REVISED 0/05/4 REAR VIEW CAC2AI02 CAC2FA250 AIR OUT FILTER ASSEMBLY DETAIL (CAC2AOF0) SEE DRAWING # 2 AIR IN CAC2AI0 CAC2F038 CAC2FBA033 CAC2AOF07 AIR OUT CAC2F035 CAC2F060 CAC2HA05 CAC2F03 CAC2AO0 CAC2AO02 Rev. 3/4/4 8

Aftercooler Components 4.0 REPLACEMENT PARTS LIST (#CAC2CF250CA) REVISED 0/05/4 PART # CAC2FA250 CAC2GA00 CAC2FBA033 CAC2F030 CAC2F03 CAC2F035 CAC2AI0 CAC2AI02 CAC2F038 CAC2AO0 CAC2AO02 CAC2HA03 CAC2AOF0 CAC2AOF02 CAC2AOF03 CAC2AOF04 CAC2AOF05 CAC2AOF06 CAC2AOF07 CAC2AOF08 CAC2F060 CAC2HA04 CAC2HA05 CAC2F059A IB0B26 CAC2F06 CAC2F064 TUBING FRAME ASSEMBLY W/WELD ON BRACKETS - SMALL COOLER RADIATOR GUARD ASSEMBLY W/BOLTS INLET PIPE SUPPORT ASSEMBLY W/BOLTS UPPER RADIATOR MOUNTING BRKTS W/BOLTS LOWER RADIATOR MOUNTING BRKTS W/BOLTS REGULATOR MOUNTING BRKT AIR IN COUPLING & BRKT W/BOLTS AIR IN PIPE ASSEMBLY RADIATOR ASSEMBLY W/FAN & SHROUD AIR OUT PIPE ASSEMBLY W/JIC FITTING WATER AUTO DRAIN HOSE ASSEMBLY - RADIATOR TO SEPARATOR AIR OUT FILTER ASSEMBLY ELBOW ASSEMBLY WATER SEPARATOR PIPE NIPPLE COALESCING FILTER ASSEMBLY ELBOW ASSEMBLY W/ 3/8 PORT DISCHARGE BALL VALVE BALL VALVE - FAN MOTOR CONTROL FAN AIR MOTOR W/SPACER & BOLTS HOSE ASSEMBLY W/FITTINGS - VALVE TO REGULATOR HOSE ASSEMBLY W/FITTINGS - REGULATOR TO FAN MOTOR FILTER/REGULATOR-3/8" PORTS (250 PSI) 0" SOLID WHEELS 7/6" S.S. U BOLTS (5/6") NYLOC NUT - WHEEL RETAINING DESCRIPTION (2) -RT -LT 2 2 2 # PER EA. MACHINE (2) -RT -LT 9 Rev. 3/4/4

TO ORDER BLASTING DRY ICE OR FOR SERVICE CALL: -800-DRY-ICE2 www.continentalcarbonic.com For a full product line please visit www.continentalcarbonic.com.