NIBE VVM 500 FLEXIBLE INDOOR MODULE INTELLIGENT HOT WATER NIBE VVM 500. Flexible all-in-one indoor module for heating and hot water.

Similar documents
NIBE VVM 300. Intelligent hot water NIBE VVM 300. VVM 300 is designed for connection and communication

NIBE F1245 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1245

Installer manual NIBE VVM 500

Installer manual NIBE VVM 310

Outline principle. Application Houses with water-borne heating systems. Maximal recommended heating output 13.5 kw. Alternative

NIBE SPLIT ACVM 270 Air/water heat pump

Installer manual SMO 40

NIBE F2026 air/water heat pump. fresh air s free. NIBE F2026. Efficient scroll compressor that operates at temperatures down to -20 C.

Installer manual ELK 213 Immersion heater

NIBE F1355. A +++ The system's efficiency class for heating. Speed-controlled ground source heat pump for large buildings. Ground source heat pump

Installer manual AXC 30

Installer manual NIBE VVM 320

Installer manual SMO 40

Installer manual AXC 40. Accessories IHB GB LEK

Outline principle. Application Houses with water-borne heating systems. Alternative Select the desired configuration by highlighting the boxes below.

Installer manual SMO 20

Installer manual SMO 40

Installer manual NIBE VVM 310. Indoor module IHB GB

Installer manual NIBE F1145. Ground source heat pump. UK 1x230V IHB GB LEK

INSTALLATION AND MAINTENANCE INSTRUCTIONS AMB AMB 30 LEK

Installer manual NIBE F730

Installer manual NIBE VVM 500. Indoor module APH

Installer manual NIBE VVM 310

NIBE F470 A + Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery. Exhaust air heat pump

Outline principle. Application Buildings with water-borne heating systems. Alternative

Installer manual NIBE VVM 310. Indoor module IHB GB

Outline principle. Application Buildings with water-borne heating systems. Alternative

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V IHB GB

Installer manual NIBE VVM 320. Indoor module IHB GB

Installer manual NIBE VVM 320. Indoor module IHB GB

Installer manual NIBE VVM 500. Indoor module APH

NIBE F2120 Air/water heat pump

NIBE SPLIT HBS 05 Air/water heat pump

Installer manual NIBE VVM 500

Ground source heat pump NIBE F1255

User manual NIBE F370

NIBE F750 A +++ Flexible, high-performance exhaust air heat pump. Exhaust air heat pump

Installer manual NIBE F1245. Ground source heat pump. UK 1x230V

User manual NIBE F370 1x230 V

Installer manual NIBE F370. Exhaust air heat pump IHB GB LEK

Installer manual AHP/AHPS

Heating when you need it Cooling when you don t

Installer manual SMO 40. Control module IHB GB LEK

Installer manual NIBE F1145

air/water heat pump. NIBE F2040 provides

Installer manual NIBE F470

NIBE IT S IN OUR NATURE

Installer manual SMO 40

ELK 26 INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK 26

Installer manual AHP/AHPS

Air/water heat pump NIBE F2120

SOLAR 42 IHB LEK

MOS GB NIBE VVM INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE VVM 300 VVM 300 LEK

Installer manual NIBE F1245

Installer manual SMO 20. Control module IHB GB LEK

Installer manual NIBE F750. Exhaust air heat pump IHB GB LEK

Installer manual SAM 40. Supply air module IHB GB LEK

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

HT V2 HT Split

User manual NIBE VVM 320

Indoor module NIBE VVM 500

Installer manual NIBE VVM 325. Indoor module IHB GB APH

NIBE SPLIT ACVM 270, AMS 10

Technical description. Atec.

Installer manual NIBE F1245PC. Ground source heat pump IHB GB

Operating manual NIBE F1355

Installer manual NIBE F1245. Ground source heat pump IHB GB

PELLUX INSTALLATION AND MAINTENANCE INSTRUCTIONS PELLUX 100 H AP

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

MOS GB SMO INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE SMO 10

Efficient heating that won t cost the earth

Operating manual NIBE F1345

User manual NIBE F730

NIBE SPLIT ACVM 270, AMS 10

Planning guide. (2010/09) en

Installer manual NIBE FLM. Exhaust air module IHB GB LEK

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Installation, operation and maintenance. Accumulator tank. Acc-tank 500 CU. Acc-tank 500 UB ver: Supersedes:

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

User manual NIBE F1145PC

Planning guide. Atec.

Accumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU

INSTALLATION AND MAINTENANCE INSTRUCTIONS MOS GB NIBE VVM 300 UK NIBE VVM 300 UK 230 V VVM 300 LEK

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

Heat pumps. for larger residential and commercial installations. Made in Sweden

INSTALLATION AND MAINTENANCE INSTRUCTIONS ELK ELK 15 LEK

FIL-SPL Flow-through heater for central heating USER MANUAL

Air/water - Heat pumps

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

MAKING MODERN LIVING POSSIBLE. Wiring Diagram. DHP-iQ.

NIBE EXHAUST AIR NIBE EXHAUST AIR. A new generation of heat pumps

NIBE SPLIT ACVM , AMS 10

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Installation and Commissioning Manual

ELECTRIC BOILERS FOR CENTRAL HEATING

Installer manual ELK 213 Immersion heater

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Transcription:

NIBE VVM 500 FXIB INDOOR MODU INTELLIGENT HOT WATER Flexible all-in-one indoor module for heating and hot water. For upgrading existing heating systems or new buildings with requirements for high performance hot water. Together with NIBE VVM 500, NIBE s air/water heat pumps offer a complete system for heating and domestic hot water. A new generation control module with colour display and several new functions. Integrated solar coil and solar control for connection to solar panels or to a stove with back boiler. Simple connection to and control of external heat source (wood/oil/gas and immersion heater). Prepared for pool heating. Prepared for control of two or more climate systems. Possible to control and monitor NIBE VVM 500 remotely. Integrated buffer tank for the heating system. High hot water capacity, (up to 500 litres at 40 C at 12 litres/ min) in combination with NIBE F2300. Stainless steel hot water coil Climate controlled shunt supply that monitors outdoor temperature Self regulating speed controlled charger and A-class designed heat pump NIBE VVM 500 VVM 500 is a flexible indoor module. Together with air/ water outdoor modules F2300-14/-20 or F2026-6/-8/-10 it creates a complete system to supply heating and hot water requirements of buildings. VVM 500 can receive energy from several different alternatives, such as outdoor heat pumps F2300 and F2026. It can also be supplemented with energy from the existing boiler instead of using the internal immersion heater. You can also use solar power. There are eight complete solar packages with panels and accessories that use the internal solar coil and control. Solar energy is primarily used to cover hot water needs. When enough water is heated, solar energy can be used to heating the house and even a pool. Another energy alternative is a stove with back boiler.

How the NIBE VVM 500 works System diagram VVM 500 is designed for connection and communication with NIBE s air/water heat pumps, and offer a complete heating system. NIBE s air/water pumps cover most of a home s heating and hot water requirements. VVM 500 operates together with NIBE s air/water heat pumps. If the outdoor temperature drops to a level below the stop temperature of the heat pump the VVM 500 heats the home. Together with F2300, VVM 500 satisfies the heating requirements of buildings from 12 24 kw in a climate with outdoor temperature above -25 C. Where less heating is required, use the F2026. Use the NIBE VPDIM software to decide the correct heat pump size. The hot water capacity depends on which outdoor module you select and whether and add-ons are allowed. For example with the F2300-VVM 500 system the tap volume is 500 litres (40 C) at 12 litres/min when the tank is filled with just the F2300. When combined with an outdoor pool in the summer, The F2300-VVM500 system s outdoor unit does not normally need higher dimensioning. This is because the building s heating requirement is less in the summer time and F2300 s output and efficiency increases with warmer outdoor temperatures. Solar panels connected to VVM 500 can also be used to heat the pool. The VVM 500 and NIBE s air/water heat pumps offer complete flexibility. VVM 500 is prepared for pool heating, solar panels or when other external heat sources should be included in the system. Basic docking with hot water and a heating system 2 NIBE VVM 500

NIBE VVM 500 flexibility Design NIBE VVM 500 is equipped with an intelligent and easy to use controller. The controller optimises the two circulation pumps. Both the flow to the outdoor heat pump and the flow to building are adapted to actual demands on heating or hot water. The required input is defined by the installer during the start up procedure. The controller is intuitive for both installers and end users. If a problem occurs there are several ways to log and analyze selected parameters. Software updates are downloaded via the USB connection. The hydraulic concept offers true flexibility and a robust installation. The lower part of the cylinder is used as a heating buffer volume, meaning no extra buffer volume independent of the building s heating system is needed. Energy is provided to the NIBE VVM 500 by the outdoor heat pump to the top of the tank or to the bottom depending on demand. Solar panels can be connected to the built in coil and solar energy can be used for hot water, heating a pool or indoor heating. In the latter case heating water above the stratification plate is transferred into the heating system. An existing boiler can be connected to the upper water volume. Another way is to feed energy using the immersion heater. It can be used for heating and hot water backup. The controller decides when and how much of the available energy sources should be fed into the NIBE VVM 500. It also prioritizes demands for heating, hot water and swimming pool. System overview F2300 - VVM 500 F2026 - VVM 500 Max recommended flow line temperature for heating system. 65 55 Max hot water capacity with outdoor section 24 l/min, 250 l, 40 C DUT* >-25 C Available heating output at -20 C (incl immersion heater) 15 kw (F2300-14) 19 kw (F2300-20) 16 l/min, 175 l, 40 C DUT* >-20 C 9 kw, internal immersion heater Available heating output at -25 C 9 kw, internal immersion heater 9 kw, internal immersion heater Available heating output, Outdoor temperature -24 C (F2300) or -19 C (F2026) Available heating output, Outdoor temperature -26 C (F2300) or -21 C (F2026) Internal immersion heater Max connectable external addition Max available heating output from VVM 500 with electrical addition (for example EL 15) Max connectable output for external additional coil (1.5 m2) 16 kw (F2300-14 and -24 ー C) 19 kw (F2300-20 and -24 ー C) 9 kw (F2300-14 and -26 ー C) 9 kw (F2300-20 and -26 C) 9 kw 25 kw 24 kw 8 kw 12 kw (F2026-6 and -19 C) 13 kw (F2026-8 and -19 C) 14 kw (F2026-10 and -19 ー C) 9 kw (F2026-6 and -21 C) 9 kw (F2026-8 and -21 ー C) 9 kw (F2026-10 and -21 ー C) Max hot water temperature (with compressor) 65 C 58 ー C Max hot water temperature (with internal immersion heater) 75 ー C 65 C VVM 500 must be located in a frost and condensation free room at ambient temperature Max temperature in tank 5 30 ー C 85 ー C "Dimensioned outdoor temperature NIBE VVM 500 3

0 R 0 R GOOD TO NOW ABOUT NIBE VVM 500 Quick and simple installation No extra buffer tank for the heating system is required as VVM 500 fully controls the heat pump and the heating system. New control with colour display and USB port. Installation help with step by step guide through the startup process. Automatic setting of flow across heat pump and heating system. Factory installed components for best operational reliability and safe installation. Complete accessory program. Transport and storage NIIBE VVM 500 must be transported and stored upright and dry. The VVM 500 may, however, be carefully laid on its back when being moved into a building. Maintenance A minimum level of maintenance is required. Only safety valves require checking. All essential components can be accessed from the front. This facilitates service and maintenance. Installation VVM 500 is easy to install. All pipe connections are easily accessible. This is especially useful for the replacement market. Equipment VVM 500 is equipped with a drain and reversing valve. In addition, VVM 500 is equipped with climate controlled automatic bypasses with outdoor and flow sensors, shunt valve, charge and circulation pump. Expansion vessel Dimensioned as 5 % of the maximum system volume (that is 500 litres plus maximum circulating volume in the hot circuit). Design VVM 500 is equipped with an intelligent control. This makes for easy operation at the same time as always enabling the indoor module to run as efficiently as possible. The control manages the automatic bypass and circulation pumps. Current temperatures and set values can be shown on the display. The insulation consists of moulded, freon-free polyurethane which is equivalent to approximately 200 mm mineral wool. The outer casing is of white powder-coated steel plate. Assembly Position VVM 500 on a firm base that can bear its weight, preferably on a concrete floor or foundation. Use the product's adjustable feet to obtain a horizontal and stable set-up. The area where VVM 500 is located must be equipped with floor drainage. Pipe dimensions XL4 CM1 Installation area Leave a space of 500 mm in front of the product. All service on VVM 500 can be carried out from the front. XL8 XL9 XL3 Connection CM1 Expansion tank (connection) Ø G20 internal Heating medium, flow line Ø G25 internal NOTE! Leave 10-25 mm free space between the indoor module and the wall behind for routing of cables and pipes. 500 Heating medium, flow line Ø G25 internal XL3 Cold Water リ G25 internal XL4 Hot Water Ø G25 exernal XL8 Connection, docking in heating medium Ø G25 internal XL9 Connection, docking out heating medium Ø G25 internal 4 NIBE VVM 500

GOOD TO NOW ABOUT NIBE VVM 500 Dimensions 756 734 691 725 791 900 1788 19 28 43 25-50 648 660 381 290 66 85 57 61 73 382 154 296 763 NIBE VVM 500 5

GOOD TO NOW ABOUT NIBE VVM 500 Indoor module design XL8 XL9 QM20 XL3 GP12 BT2 XL39 AA4 QN10 BT63 EB1 VVM 500 SF1 AA4-XJ3 AA4-XJ4 FD1 QN11 8 BT3 UB1 UB2 AA3 GP1 AA1 BT6 9 FA1 3 BT54 AA2 4 QN35 AA7 APH PF1 PF3 QM1 PF1 PF3 BT7 XL4 CM1 XL8 XL9 XL3 4 XL39 QM20 8 9 3 6 NIBE VVM 500

GOOD TO NOW ABOUT NIBE VVM 500 List of components Pipe connections Connection, heating medium flow line Connection, heating medium return line XL3 Connection, cold water XL4 Connection, hot water XL8 Connection, docking in heating medium XL9 Connection, docking out heating medium 3 Connection, solar system flow line (SCA 30) 4 Connection, solar system return line (SCA 30) 8 Connection, docking in high temp (DEH 500) 9 Connection, docking out high temp (DEH 500) XL39 Connection, docking pool (POOL 500) Electrical components AA1 Immersion heater card AA2 Base card AA3 Input circuit board AA4 Display unit AA4-XJ3 USB port AA4-XJ4 Service socket AA7 Extra relay circuit board EB1 Immersion heater FA1 Miniature circuit-breaker FD1 Temperature limiter SF1 Switch HVAC components CM1 GP1 GP12 QM1 QM20 QN10 QN11 QN35 Expansion tank (connection) Circulation pump Charge pump Drain valve, heating medium Venting, climate system Reversing valve, climate system/heating medium, flow line Mixing valve Reversing valve, climate system/heating medium, return line Other information PF1 Rating plate PF3 Serial number plate UB1 Cable grommet UB2 Cable grommet * Not visible in the image Designations in component locations according to standard IEC 81346-1 and 81346-2 Sensors etc. BT2 Temperature sensors, heating medium flow BT3 Temperature sensor, heating medium return* BT6 Temperature sensor, hot water, control BT7 Temperature sensor, hot water, display* BT54 Temperature sensor, solar coil BT63 Temperature sensor, heating medium supply after immersion heater NIBE VVM 500 7

INSTALLATION VVM 500 is easy to install. All pipe connections are easily accessible. Installation alternative Heat pump All outdoor pipes must be thermally insulated with at least 19 mm thick pipe insulation. VVM 500 is not equipped with shut off valves; these must be installed outside the indoor module to facilitate any future servicing. Heating medium side When connecting to a system with thermostats on all radiators/ underfloor heating coils, a relief valve must be fitted, or a thermostat must be removed to ensure sufficient flow. XL8 XL9 -FL10 -RN10 -QM40 -QM1 -HQ1-QM41 Electric boiler mode Connect the pipe for docking in from the heat pump (XL8) to the pipe out from the heat pump (XL9). XL8 XL9 Two or more climate systems When more than one climate system is to be heated, the following connection can be used. For this connection accessory ECS 40/ECS 41 is required. (Max 4 zones) -EP21 -AA5 -BT2 -GP20 -QN11 -BT3 Cold and hot water A mixing valve must be installed if the factory setting is changed so that the temperature can exceed 60 C. If the factory setting is changed, national regulations must be observed. The setting is made in menu (5.1.1). XL4 XL3 External heat source Connection of gas/electric/oil boiler requires accessory DEH 500, see "Accessories" on the product sheet rear cover and the installation manual for DEH 500. -EM1 -AA5 -BT52 -EM1 8 9 -GP15 8 NIBE VVM 500

INSTALLATION Connecting hot water circulation To reduce the risk of bacterial growth in systems with hot water circulation, the temperature of the circulating water should not fall below 50 ー C. There should not be any non-circulatory hot water pipes. Adjust the hot water system so that the temperature does not fall below 50 C at the end of the system. In VVM 500 it is possible to schedule the connected pump (GP9). Sun Connection to solar installation requires accessory SCA 30, see Accessories on the rear cover and the installation manual for SCA 30. This docking provides both heat and hot water. -EP30 -BT53 XL4 XL3 -GP9 -FL10 -RN10 -QM40 -HQ1-QM41 -QM1 3 4 -AA5 -GP30 -RM4 -EP8 -CM5 T -RM3 T P -FL4 -GP4 -QM44 -QM45 -QM43 Pool Pool heating is controlled by the pool sensor. In the case of low pool temperatures, the shuttle valve reverses direction and opens towards the pool exchanger. This connection requires the POOL 500 accessory, see Accessories on the rear cover and the installation manual for POOL 500. Wood burning stove with back boiler Connection to the wood burning stove with back boiler, max 8kW, requires accessory SCA 30, see Accessories on the rear cover and the installation manual for SCA 30. This docking provides both heat and hot water. -CL11-QN19 -CL11 -AA5 -EP5 -GP9 -BT51 -HQ4 POOL XL39 -EP30-BT53 -EM1 -FL10 -RN10 -QM40 -HQ1-QM41 -QM1 -FL10 -RN10 -QM40 -HQ1-QM41 -QM1 -CM5 -EP30 -GP30 -AA25 -RM4 -RM3 T T P -GP4 -FL4 -QM44 -QM45 -QM43 NIBE VVM 500 9

INSTALLATION Pool and solar In this example the solar installation is connected. When solar heating has heated the tank to the desired stop temperature, the solar heat will be transferred to the pool. Charging the pool continues until the pool is fully heated or until the temperature in the tank falls below the desired stop temperature. -FL10 -RN10 -QM40 -QM1 -HQ1-QM41 -GP14 -RM6 XL39 -CL11 -GP9 4 3 -BT51 -EP30 POOL -AA5 -GP30 -RM4 -BT53 -EP8 -CM5 T -RM3 T P -FL4 -GP4 -QM44 -QM45 -QM43 Electrical connections General All electrical equipment, except the outdoor sensors, room sensors and the current sensors are already connected at the factory. Disconnect the indoor module before insulation testing the house wiring. When the building is equipped with an earth-fault breaker, VVM 500 should be equipped with a separate one. The electrical circuit diagram for the indoor module is at the end of this Installer manual. Communication and sensor cables to external connections must not be laid close to high current cables. The minimum area of communication and sensor cables to external connections must be 0.5 mm 2 up to 50 m, for example EX or LiYY or equivalent. You must use cable grommets UB1 and UB2 when cable routing in VVM 500. In UB1 and UB2 the cables are inserted through the indoor module from the back to the front. Pool with heat pump and solar Charging of the pool is controlled by the pool sensor. In the case of low pool temperatures, the shuttle valve reverses direction and opens towards the pool exchanger. This connection requires the POOL 500 accessory, see Accessories on the rear cover and the installation manual for POOL 500. In this example the solar installation is connected. When solar heating has heated the tank to the desired stop temperature, the solar heat will be transferred to the pool. Charging the pool continues until the pool is fully heated or until the temperature in the tank falls below the desired stop temperature. -GP14 -RM6 -CL11 -AA5 -GP9 -BT51 POOL Miniature circuit-breaker The indoor module and a large proportion of its internal components are internally fused by a miniature circuit breaker (FA1). Temperature limiter The temperature limiter (FD1) cuts the current supply to the electrical addition if the temperature rises to between 90 and 100 degrees C and is manually reset. Settings Electrical addition - maximum output The immersion heater can be set to a maximum of 9 kw. Delivery setting is 9 kw. The immersion heater output is divided into 4 steps, according to the table in the Installer manual. Setting maximum output in the electrical addition is done in menu 5.1.12. XL39 -EP30 -BT53 -EP8 Standby mode When the indoor module switch (SF1) is set to emergency mode only the most necessary functions are activated. -FL10 -RN10 -QM40 -HQ1-QM41 -QM1 4 3 -CM5 -AA5 -GP30 -RM4 T T P -FL4 -GP4 -QM44 -QM45 -QM43 The hot water capacity is reduced. The load monitor is not connected. Temperature is fixed in the flow line 10 NIBE VVM 500

INSTALLATION Pump capacity diagram Available pressure, circulation pump for heating systems, GP1 Available pressure, charge circulation pump, GP12 Available pressure Tillgängligt tryck (Pa) (Pa) 70 Tillgängligt Available tryck pressure (Pa) (Pa) 70 60 60 50 50 40 40 30 20 100% 30 20 100% 10 25% 0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 Water Vattenflöde flow (l/s) (l/s) 10 25% 0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 Water Vattenflöde flow (l/s) Water capacity Hot water capacity NIBE VVM 500 with NIBE F2026/F2300 Tappflöde flow (l/min) 30 28 26 Economy Ekonomi Normal Lux Lyx 24 22 20 18 16 14 12 10 Tappvolym volume (l) 40 (l) C40 ー C 100 150 200 250 300 350 400 The diagram above displays what hot water capacity VVM 500 can supply at the different selectable comfort modes. The difference between the selectable modes is the temperature of the hot tap water. Higher temperature means hot water lasts longer. economy: This position gives less hot water, but is more economical. This mode can be used in smaller households with a small hot water requirement. normal: Normal mode gives a larger amount of hot water and is suitable for most households. luxury: Lux mode gives the greatest possible amount of hot water. In this mode, the immersion heater, as well as the compressor, is used to heat hot water, which may increase operating costs. F2026 requires additional heat (internal or external) to reach Luxury. In most cases, F2300 reaches all three settings (including Lux), with just a compressor. NIBE VVM 500 11

THE DISPLAY A large, easy to read multicoulour display gives everyone the chance to maximize the energy saving potential of this exciting green technology! Display unit Display, A Instructions, settings and operational information are shown on the display. The easy-to-read display and menu system facilitates navigation between the different menus and options to set the comfort or obtain the information you require. Status lamp, B The status lamp indicates the status of the heat pump. It: lights green during normal operation. lights yellow in emergency mode. lights red in the event of a deployed alarm. O button, C The O button is used to: confirm selections of sub menus/options/set values/page in the start guide. Control knob, E The control knob can be turned to the right or left. You can: scroll in menus and between options. increase and decrease the values. change page in multiple page instructions (for example help text and service info). Switch, F The switch assumes three positions: On () Standby ( ) Emergency mode ( ) Back button, D The back button is used to: go back to the previous menu. change a setting that has not been confirmed. VVM 500 A B C D E F Display Status lamp O button Back button Control knob Switch 12 NIBE VVM 500

THE DISPLAY Menu system When the door to the heat pump is opened, the menu system s four main menus are shown in the display as well as certain basic information. Outdoor temp. Indoor temperature - (if a room sensor is connected) Hot water temp. Menu 1 Indoor climate Setting and scheduling the indoor climate. Menu 2 Hot water Setting and scheduling hot water production. This menu only appears if a water heater is docked to the heat pump. Menu 3 - Info Display of temperature and other operating information and access to the alarm log. Extra hot water (if activated) Estimated amount of hot water Menu 4 Heat pump Setting time, date, language, display, operating mode etc. Menu 5 - Service Advanced settings. These settings are not available to the user. The menu is visible by pressing the Back button for 7 seconds. Start guide The first time the heat pump is started a start guide is started. The start guide instructions state what needs to carried out at the first start together with a run through of the heat pump s basic settings. The start guide ensures that the start-up is carried out correctly and cannot be bypassed. The start guide can be started later in menu 5.7. 1/21 START GUIDE 5.7 START GUIDE 5.7 START GUIDE 5.7 START GUIDE 5.7 If the start guide is left on this page it closes automatically in 60 min NIBE VVM 500 13

TECHNICAL SPECIFICATIONS IP 21 3x400V Max heat pump output 1) kw 20 Additional power immersion heater kw 9 Electrical data Rated voltage 400 V~ 3 NAC 50 Hz Max operating current A 16,2 Fuse A 16 Power, HM pump W 10-110 Output charge pump W 10-110 IP class IP 21 Heating medium circuit Energy class circ-pump Energy class charge pump low energy low energy Max system pressure heating medium MPa 0.3 (3 bar) Min flow l/h 500 Max HM temp ー C 70 Pipe connections Heating medium, CU pipe G25 internal Hot water connection G25 internal Cold water connection G25 internal Heat pump connections G25 internal Other information Indoor module Area HW coil m 2 5 Volume, total indoor module l 500 Volume, buffer vessel l 80 Area, solar coil m 2 1,5 Cut-off pressure, coil MPa 1.0 (10 bar) Max permitted pressure in indoor module MPa 0.3 (3 bar) Capacity hot water heating According to EN 255-3 Tap volume 40 C at Eco comfort l 235 Tap volume 40 C at Normal comfort l 303 Tap volume 40 C at Luxury comfort l 378 Idle loss according to DIN 4753-8 W 116 Dimensions and weight Width mm 760 Depth mm 900 Height mm 1900 Required ceiling height mm 2000 Weight (excl packaging) kg 240 Part no. 069 400 1) Applies to outdoor air heat pump at 7/45 C (outdoor temperature / Supply temperature) 14 NIBE VVM 500

SUPPLIED COMPONENTS Outdoor sensor Room sensor Current sensor O-rings The kit of supplied items is placed on top of the product. D IP 44 TF 110 Class H Max. 10bar 1m(A) P,(W) 0.20 45 0.30 65 0.40 90 APH Type UPS 25-60 230V50Hz 2.5uF 130 GRUNDFOS HEJSAN P/N:59526447 PC;0017NIB ACCESSORIES NIBE EM 500 Energy measurement kit This accessory is used to measure the amount of energy VVM 500 produces and supplies for hot water and heating in the building. 067 178 NIBE ECS 40/ECS41 Extra shunt group This accessory is used when VVM 500 is installed in houses with two or more different climate systems that require different supply temperatures. ECS 40 (max 80 m2) 067 061 ECS 41 (min 80 m2) 067 099 NIBE HR 10 Auxiliary relay 089 423 NIBE MODBUS 40 Communications module MODBUS 40 enables VVM 500 to be controlled and monitored using a design outdoor temperature in buildings. Communication takes place using a MODBUS-RTU. 067 144 NIBE EL External electrical addition These accessories require accessory DEH 500 (step controlled addition). EL 26 067 074 EL 15 067 022 NIBE SMS 40 Communications module SMS 40 enables VVM 500 to be controlled and monitored via SMS messages. The mobile application NIBE Mobile App can be used with a mobile telephone with the Android operating system. Part no. NIBE POOL 500 Pool heating POOL 500 is an accessory that enables pool heating with VVM 500. 067 181 NIBE RMU 40 Room unit RMU 40 means that control and monitoring of the indoor module can be carried out in a different part of the home to where VVM 500 is located. NIBE RTS 40 Room sensor NIBE SCA 30 (solar) Possible connection and control of solar heating. 067 065 067 179 067 179 067 073 NIBE DEH 500 (oil/electricity/gas) Possible connection and control of external heat source. Part no. 067 180 NIBE F2026 Air/water heat pump NIBE F2300 Air/water heat pump 6 kw 8 kw 10 kw 14 kw 20 kw Part no. 064 084 Part no. 064 085 Part no. 064 086 Part no. 064 063 Part no. 064 064 NIBE Top cabinet 2060 mm 056 177 2160 mm 056 178 2200-2,450 mm 056 179 NIBE premium solar packs for VVM 500 Vertical collectors: P2 Part no. 057 102 P3 Part no. 057 103 P4 Part no. 057 104 P5 Part no. 057 105 Horizontal collectors: PL2 Part no. 057 106 PL3 Part no. 057 107 PL4 Part no. 057 108 PL5 Part no. 057 109 NIBE VVM 500 15

NIBE is ISO-certified: SS-EN ISO 9001:2000 SS-EN ISO 14001:2004 This brochure is a publication from NIBE. All product illustrations, facts and specifications are based on current information at the time of the publication s approval. NIBE makes reservations for any factual or printing errors in this brochure. Photos: www.benfoto.se. NIBE 2012. 16 NIBE VVM 500 NIBE Energy Systems AB Box 14 285 21 Markaryd SWEDEN Tel. +46 433-73 000 www.nibe.eu 639509 Technical PBD GB NIBE VVM 500 1244-1