Please make yourselves familiar with the changes and start implementing them immediately so you can be better prepared for June 30 th, 2018.

Similar documents
Electrical Tech Note 107

2011 and 2014 National Electrical Code Changes Residential Only

Instructor: L. Keith Lofland

Overview of Significant 2017 NEC Changes

ELECTRICAL BULLETIN

2009 ELECTRICAL CODE REQUIREMENTS

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

Bulletin An application for inspection not required Rule 2-005

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

NEC {CODE CHANGES. OVERVIEW OF 2014 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

2014 National Electrical Code & NFPA 70E/Arc Flash

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

Alberta Municipal Affairs

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

Chapter 1 General... 5

WIRING AND PROTECTION

TECHNICAL ARTICLE. Inspecting Existing Dwelling Electrical Systems Using NFPA 73 by Skip Walker September 2009

2017 NEC Presented by: Russ LeBlanc

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

TOM BURNS, PLANNING DIRECTOR

NEC Code Changes. Overview of 2011 Related to Electrical Wiring Devices. Cablofil. Pass & Seymour. Wiremold

National Electrical Code

Commercial Renovation Investigation Program

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

Arc-Fault Circuit Interrupters (AFCIs) Frequently Asked Questions

Units 2, 3, 4, 5, 6, 8, 9, 10, Electrical Wiring Residential Unit 2 (Unit 5 Fourth Edition)

Second Revision No. 321 NFPA [ Detail ] Submitter Information Verification. Committee Statement. Make the following changes to 210.

IEC and NCCER Mapping for Year 1

NEC Study Guide CORRECT: C NEC (A)(1)

PLUG int o HOME SAFETY

Revisions for the 2011 National Electrical Code - Part 1

Power over Ethernet cable Product standards and Installation code Updates. Julian Mereuta - June 1, 2017 Banff, Alberta

Residential Wiring (2014 NEC) (Homestudy)

Building and Safety Division Civic Center Dr, Bellflower, CA, (562) x

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire

Graded Project. National Electrical Code

Spa Control System OWNER S MANUAL

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

GROUND FAULT PROTECTION METHODS & 2017 National Electric Code

Alberta Municipal Affairs

Troy's Home Inspection Services LLC

SAN JOAQUIN COUNTY ELECTRICAL PLAN CHECK CORRECTION SHEET (209) FAX (209)

NFPA 70 May 2001 ROP Copyright 2000, NFPA

Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

Town of Cicero Local Code Amendments

NEC ROP/ROC Code Making Panel Meetings

Residential Wiring According to 2011 NEC (Homestudy)

2016 Electrical Supplemental Plan Review List

Spring Test 6 due 04/26/2013

WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY

Red Deer. AMA Regional Meeting. Electrical, Plumbing, Gas, Private Sewage, Building and Fire

Electrical Hazards and NFPA-70E: Protecting Your Employees

CHAPTER 14 ELECTRICAL CODE

Photovoltaic (Solar) Array Installation Guide

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

ELECTRIC and NEON SIGN STANDARDS. By Randy Wright RKW CONSULTING

2014 NEC for. Understanding the. AFCI protection AFCI code compliant safety. Eaton is a registered trademark.

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Electric Shock Drowning

ll. Consistency Questions

technology using advanced to reduce electrical fires arc fault circuit interrupters

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev

NEC 2017 Changes and Their Effect Upon the ICT Industry

How to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers

Electrical Program. Electrical Laws & Rules. Electrical RCW WAC B. Permits Inspections Access Description Directions Comments.

Residential Wiring (2017 NEC) (Homestudy)

Residential Wiring According to the 2011 NEC

PANELBOARDS & BUILDING DISTRIBUTION

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

All electrical practitioners know too well that water and electricity do

SECTION AUTOMATIC TRANSFER SWITCHES

Construction Codes Advisory Council

NEC CODE QUESTIONS and ANSWERS Wisconsin Chapter IAEI Green Lake, Wisconsin May 16-18, 2012

RESIDENTIAL OVER. 4. Would it be permissible to hard- wire the dishwasher in question 3? If so, under what conditions?

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Data Bulletin. Determining the Cause of AFCI Tripping Class 760

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

Municipal Code of Chicago TITLE 14E ELECTRICAL CODE

Revisions for the 2011 National Electrical Code - Part 4

TABLE 1-E (2017) Effective July 1, 2017

Understanding Your Options: AFCI Protection and the 2015 CE Code

Combination Type AFCI

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE

Intellectual Properties, Trademarks and Copyrights

Transcription:

Included below are the top fifteen changes within the 2018 Canadian Electrical Code (CEC). Here in Newfoundland and Labrador, the 2018 Code was adopted as of January 1 st, 2018 and will be enforced as of June 30 th, 2018. Please make yourselves familiar with the changes and start implementing them immediately so you can be better prepared for June 30 th, 2018. Now in its 24th edition, the 2018 Canadian Electrical Code, Part I include a number of significant updates and changes to better help electrical workers in the safe maintenance of electrical equipment and create safer electrical installations. This edition features important revisions to many sections. For example, Section 26 now mandates the use of tamper-resistant receptacles in additional areas where children may be present. Section 62 now requires ground fault circuit interrupter protection for heating devices and controls in proximity to tubs, sinks, and shower stalls. Section 10 has been updated, reorganized, and significantly reduced in length. Requirements for power over Ethernet systems have been added to Section 16, and requirements for marinas, wharves, and similar facilities have been substantially updated and reorganized in Section 78. Listed on the following pages are the top 15 changes to the code.

1. Power over Ethernet 2015 Code No specific requirements 2018 Code New Subsection 16-300 POE (Power over Ethernet) has existed for many years however, recent revisions to IEEE standards for communications cables has opened the door to higher power applications for POE, such as room lighting. Through these cables, power levels approaching 100 W are possible, along with simultaneously communications between devices and systems. POE is typically implemented as a "structured" cable system, wherein cables are bundled together for extended lengths. Cable heating is a function of the power it carries and as such, installation and layout become critical factors in ensuring safe operation. New requirements for POE have been added to the Code in the form of new Rules 16-300 through 16-350, and Table 60. 2. Installation of identified conductor at control locations 2015 Code Two wire simple switch loop acceptable 2018 Code Identified conductor required at every control location Control devices are increasingly used as an essential part of energy management systems. Many of these devices require power to operate, and where used in a simple switch loop, create a small current through the bonding conductor. As the number of devices increases, the cumulative current through the bonding system will become unacceptable. New Subrule 4-028(2) now mandates that an identified conductor be installed at each manual or automatic control location. This requirement applies to all occupancy types. The term neutral has been replaced with the more accurate term identified conductor. 3. Bonding and grounding 2015 Code 15 pages long and two tables 2018 Code 8 pages long and one table Section 10 requirements have been reorganized into a more logical flow of requirements and significantly reduced in size. Objectives for solidly grounded, impedance grounded, and ungrounded systems are clearly specified at the beginning of the Section. Tables 16A and 16B have been combined into a single Table, with Rule 10-614 providing specific conditions for selecting the size of bonding conductor or bonding jumper. 4. Arc fault circuit interrupters 2015 Code AFCI protection required, with some exemptions 2018 Code exemptions tightened, application to existing circuits clarified

Clarification is now provided for AFCI protection of existing branch circuits that are extended due to renovations or additions. Exemptions from AFCI protection have been reduced or removed for number of areas including branch circuits supplying smoke alarms, carbon monoxide alarms, and bathrooms. 5. Disconnecting means for LED luminaires 2015 Code disconnecting means required for fluorescent ballasts 2018 Code disconnecting means required for fluorescent ballasts and LED drivers To support safe maintenance, the Code has for several editions required disconnecting means for fluorescent luminaires utilizing double ended lamps and operating at more than 150 V. With increased use of LED lighting, the requirements have been extended to LED luminaires exceeding 150 V to ground with double ended lamps. 6. Tamper resistant (TR) receptacles 2015 Code TR receptacles required in dwelling units and child care facilities 2018 Code TR receptacles required in additional occupancy types The requirement for tamper resistant receptacles in dwelling units and child care facilities is expanded to include other areas where children may be present including hotel guest rooms, preschools, and elementary education facilities. 7. Equipment connected to devices having Class 2 outputs 2015 Code approval requirement based on application 2018 Code approval based on voltage and application. Voltage limited by location. Products having a Class 2 output are covered by a number of standards including C22.2 No. 60950-1 (LPS), C22.2 No. 66.3 (Class 2 transformer) C22.2 no. 223 (ELV), C22.2 No. 250.13 (LED), and C22.2 No. 62368-1 (AV and IT). The output voltage from these supplies can vary substantially in magnitude and waveform, up to 60 Vdc. Revisions to Section 16 now set the requirements for approval of such equipment based on application, location, voltage, and waveform, and maximum permitted voltages for dry, damp, and wet locations. 8. Increased GFCI protection for wet areas 2015 Code No requirement for GFCI protection for heaters or controls in bathrooms 2018 Code GFCI protection required Similar to GFCI requirements for receptacles in the vicinity of showers, sinks or tubs, new Section 62 Rules mandate GFCI protection for electric heating devices and heating controls in the vicinity of sinks, showers or tubs.

9. Continuous loads 2015 Code complex continuous load requirements 2018 Code continuous load requirements simplified. Rule 8-104 has been one of the more misunderstood Rules in the Code, with varying interpretations of how it should be applied. Subrules 8-104(1) through (4) remain intact however, Subrules 8-104(5) through (7) have been distilled down two Subrules; one for switches and breakers marked for continuous operation at 100%, and one for switches and breakers marked for continuous operation at 80%. In both cases, the Subrules now simply require two things: (1) that the continuous load not exceed the continuous operation marking on the fused switch or circuit breaker, and (2) that the continuous load not exceed a specified percentage of the allowable ampacity determined from Section 4. Gone are references to specific columns in Tables, underground installations, and derating (correction) factors. 10. The 5% Rule 2015 Code calculated load permitted to exceed conductor ampacity by 5% 2018 Code 5% rule eliminated Subrule 8-106(1) has existed in the Code for some time however, the later introduction of Rule 8-104 put 8-106(1) in conflict. In addition, conductor ampacities are determined by Section 4, not 8, as confirmed by several related changes to Section 8. Finally, the Subrule has been inconsistently applied. As such, Subrule 8-106(1) was deleted. 11. Marking for maximum continuous load 2015 Code no labelling requirement 2018 Code maximum continuous load required to be field marked on equipment The maximum continuous load determined for a given installation may be substantially less than the equipment rating. However, there is no requirement to communicate this information to maintenance personnel, installers, or inspectors, for purposes of future maintenance or modification of the electrical system. As a result, new Subrule 2-100(4) requires that a caution label be applied to the equipment to indicate the maximum permitted continuous load. 12. Electric shock drowning 2015 Code 15 and 20 A receptacles require GFCI protection

2018 Code ground fault protection for feeders, GFCI protection for receptacles Much research has been conducted on the phenomenon known as electric shock drowning. Section 78 has been extensively updated to require GFCI and Ground Fault protection for branch circuits and feeders respectively. The scope of Section 78 has been expanded to include additional types of structures such as floating piers and docking facilities, and the Rules have been re-arranged to simplify navigation of the Section. 13. Electric vehicle energy management system 2015 Code EV supply equipment loads added to load calculations at 100% of rating 2018 Code demand factors recognized where energy management system used. Electric vehicle supply equipment (EVSE) can draw a substantial load when in the charging mode. For existing buildings, the addition of EVSE can result in the total load exceeding the existing service capacity. In this case, the first option is to increase the service size. A second option is to install a system to monitor the power being drawn by EVSEs and other building loads, and control the EVSE loads such that the overall load does not exceed the limits of the existing service, feeders, and branch circuits. In combination with new Rule 8-500 and new Subrules 8-106(11) and (12) such systems are now recognized in the Code as Electric Vehicle Energy Management Systems (EVEMS). Complementary to the introduction of EVEMS, a new Table of loads and demand factors has been added specifically for EVSE. 14. Kitchen wall (not counter) receptacles 2015 Code separate branch circuit required 2018 Code separate branch circuit not required Wall receptacles provided in a kitchen are required to be supplied by a separate circuit. However, this requirement predates the requirement for counter receptacles and circuits. Given that many kitchens are now used as general living areas, and that receptacles are now required to be provided along the kitchen wall in the same fashion as a living room, there is no longer a need for a dedicated circuit. Consequently, the requirement has been deleted. 15. Refrigerators 2015 Code separate circuit required for each receptacle installed for a refrigerator 2018 Code separate circuit only required for mandated refrigerator receptacle The existing wording of 26-722 required a separate circuit for each receptacle installed for a refrigerator. This requirement is now relaxed by permitting a dedicated circuit to supply more than one refrigerator receptacle. It has also been revised to more clearly state that the requirement only applies to receptacles mandated by 26-712(d)(i) for refrigerators in kitchens. The requirement does not apply to refrigerators installed in other locations.