Self-learning Room Temperature Controller

Similar documents
Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

REA22 Room Temperature Controller

Self-learning Room Temperature Controller

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Use. Functions. Key function. Other functions

QAW70. Room Unit. Building Technologies. for use with heating controllers

Room thermostats with LCD for wall mounting

Room thermostat with Auto Timer, Option External Input

RVL470. Heating Controller. Use. Functions. Series B

Room thermostat with Auto Timer, Option External Input

Room Unit. Building Technologies SYNERGYR

Room thermostat with Auto Timer, Option External Input

Flush-mounted room thermostats

Room Temperature Controller with LCD

Room Temperature Controller

RAA30 RAA30.16/GR RAA30.26/GR. Room Thermostat. Adjustable room thermostat for heating only or cooling only systems

Wireless room thermostat with LCD

Room Temperature Controller

Immersion Temperature Controller

Room thermostat with independent DHW control

Room thermostat with 24-hour time switch and large LCD

RVP310. Heating Controller. Building Technologies HVAC Products

Room Temperature Controllers

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

District Heating Controller

Room Temperature Sensors

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

Digital Room Thermostat for Heating Applications with 7-Day Time Program

for relative humidity and temperature

Semi flush-mount room thermostat

Room Temperature Controller

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

PRELIMINARY EDITION

Application guide RDG160 Remote control

G a

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

Semi flush-mount room thermostats

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Preliminary Release. Room Temperature

Flush-mounted room thermostat

Semi flush-mount communicating room thermostats

for relative humidity and temperature with calibration certificates

for relative humidity and temperature

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Touch Screen Flush-mount Room Thermostats with KNX Communications

Room thermostats with LCD RDD100..

Room Temperature Sensor

Frost Protection Thermostat

UV Flame Supervision System

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Room Air Quality Sensors

Landis & Gyr RAV 91 Operating Instructions

Room thermostat with Auto Timer, independent DHW

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

RVL480. Heating Controller

Saving energy while ensuring an enhanced room climate

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Use. For 2-pipe fan coils

Wall-mounted room thermostat with LCD

Operating Instructions

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Room air quality sensors

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Control solutions Biofloor

RVL481. Heating Controller. including d.h.w. heating

Room thermostat with Auto Timer, Option External Input

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

Battery Powered Electronic Room Thermostat Cat. No. TRT033

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

Room controllers with manual forced ventilation function

Infrared Flame Detectors

DUO PLUS. Instruction manual

Duct Temperature Sensors

Local Process Bus LPB

RVL479. Heating Controller. for use with a partner unit

QAA Room Unit for Boiler Control with OpenTherm Interface Basic Documentation. Siemens Building Technologies Landis & Staefa Division

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Storage tank size Rated volume [l] Actual volume [l]

E-pro. Time adaptor with E-Pro Stick for thermostatic valves

Room Temperature Sensors

Modulating clock thermostat

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Transcription:

2 224 Self-learning Room emperature Controller with analogue 24-hour or weekly time switch RAV11 Mains-independent room temperature controller featuring straightforward operation. Self-learning two-position controller providing PID control (patented). Freely selectable switching times. Use Room temperature control in: Single-family and holiday houses Apartments and office spaces Individual rooms and consulting rooms Commercially used spaces For the control of the following pieces of equipment: Solenoid valves of instantaneous water heaters Solenoid valves of atmospheric gas burners Forced draught gas and oil burners Circulating pumps in heating systems Electric direct heating Fans of electric storage heaters Zone valves (normally closed)) Functions ype summary Ordering Delivery PID control Self-learning or selectable switching cycle Freely adjustable 24-hour mode Freely adjustable weekly mode with weekly time switch Frost protection function Minimum limitation of set point Room temperature controller, DC 3 V battery powered without time switch Room temperature controller, DC 3 V battery powered with analogue 24-hour time switch Room temperature controller, DC 3 V battery powered with analogue weekly time switch Analogue 24-hour time switch Analogue weekly time switch When ordering, please give type reference according to "ype summary". he unit is supplied with batteries. RAV11 RAV11.1 RAV11.7 AUZ3.1 AUZ3.7 Siemens Building echnologies CE1N2224E / 14.01.1999 Landis & Staefa Division 1/6

8 Mechanical design Plastic casing with analogue 24-hour or weekly time switch, easily accessible operating elements and removable cover. he removable battery compartment allows straightforward replacement of the two 1. V alkaline batteries. he base plate can be fitted to all commercially available recessed conduit boxes or directly on the wall and can then be wired before fitting the controller to it. he casing accommodates the electronics with the DIP switch. he potential-free changeover contact and the connection terminals are located on the base plate. Operating elements 7 16 1 14 13 12 11 1 2 30 4 17 1 18 19 21 9 7 6 C 6 3 22 23 24 1 2 3 4 1 2 2 30 C 2224Z02 Analogue time switch appets tilted outward for normal temperature appets tilted inward for economy temperature Battery compartment wo alkaline batteries 1. V (AA) Operating mode selector AUO Heating periods according to tappet settings on time switch Continuous normal temperature Continuous economy temperature Standby with frost protection Setting knob for normal temperature Setting knob for economy temperature LED for low battery indication Position for time switch Operating modes AUO Heating periods according to tappet settings on time switch Continuous normal temperature Continuous economy temperature Standby with frost protection Set points Factory settings Setting range C 30 C 1 C 30 C CE1N2224E / 14.01.1999 Siemens Building echnologies 2/6 Landis & Staefa Division

echnical features DIP-Switch Self learning PID 12 PID 6 2-Pt 1 2 3 4 2224Z01 Control Self-learning mode he RAV11 is a two-position controller providing PID control. he room temperature is controlled through the cyclic switching of a regulating unit. he controller is supplied with an active self-learning mode, which enables it to automatically adapt to the controlled system (type of building construction, type of radiators, size of rooms, etc.). After a certain learning period, the controller optimises its parameters and then operates in the mode it has learned. In exceptional cases, where the self-learning mode may not be adequate, it is possible to choose between PID 12, PID 6 or 2-Pt mode: PID 12 mode PID 6 mode 2-Pt mode Switching cycle of 12 min for normal or slow controlled systems (e.g. massive building structures, large spaces, cast-iron radiators, oil burners). Switching cycle of 6 min for fast controlled systems (e.g. light building structures, small spaces, plate radiators or convectors, gas burners). Pure two-position control with a switching differential of 0. C (±0.2 C) for very difficult controlled systems with considerable outside temperature variations. Setting knobs Standard 30 C 30 C Version 1 * C 1 C Version 2 * 18 22 C 13 17 C Version 3 * 1 2 C C * at request Analogue time switches he unit has an opening for fitting a plug-in type switch. If desired, the time switch fitted can be replaced by another. he electrical connections to the controller are established via a terminal strip so that no wiring is required. he time switches can only be mounted in one position. he analogue time switches are equipped with a quartz clock he switching dial is equipped with tappets that can be tilted. he heating periods are entered by tilting the tappets within the required period of time: appets tilted outward: Normal temperature appets tilted inward: Economy temperature 24-hour time switch Weekly time switch he 24-hour time switch has a 24-hour switching dial. It carries 96 tappets, which means four tappets per hour, giving a resolution of 1 minutes. he shortest possible heating period also is 1 minutes. he weekly time switch has a 7-day switching dial. It carries 84 pairs of tappets, which means 12 pairs of tappets or 24 individual tappets per day. he resolution is thus one hour. However, since - for mechanical reasons - at least two tappets need to be tilted together to set one heating period, the shortest possible heating period is two hours. Siemens Building echnologies CE1N2224E / 14.01.1999 Landis & Staefa Division 3/6

Calibration of detector emp. Offset DIP-Switch Reset 2224Z17 If the measured room temperature does not agree with the temperature set on the knob, the temperature detector can be recalibrated. his can be done by adjusting a potentiometer that is located on the rear of the unit. First, the unit must be removed from the socket. 2224Z04 he possible settings on the potentiometer are: 1 2 30 ( C) ( C) Pos. 22.00.00 8 21.7.00 7 21.0.00 6 21.2.00 21.00.00 4.7.00 3.0.00 2.2.00 1.00.00 0 <= Factory setting 19.7.00 F 19.0.00 E 19.2.00 D 19.00.00 C 18.7.00 B 18.0.00 A 18.2.00 9 After the corrections are made, the new setting must be confirmed by pressing the reset button. Otherwise the previous settings are still active! After the reset the controller can be remounted to the socket. echnical Data Operating voltage DC 3 V Batteries (alkaline AA) 2 x 1. V Battery life (approx.) 2. years Backup for battery change 1 min max. - conformity to EEC directive 89/336/EEC low voltage directive 73/23/EEC Switching capacity of relays Voltage AC 24 V Current 8 (3.) A Measuring element NC 68 kω at 2 C Measuring range 0 40 C ime constant 2 min max. Set point setting range Normal temperature 3 29 C Economy temperature 3 29 C Resolution of analogue time switches 24-hour time switch 1 min Weekly time switch 60 min Set point for frost protection C Insulation class to EN 60730-1 II Degree of protection to EN 6029 IP30 Electromagnetic compatibility Immunity EN 0082-2 Emissions EN 0081-1 Perm. ambient temperature Operation 3 3 C Storage -2 +60 C Perm. ambient humidity to DIN 40040 G Weight 0.2 kg Colour White RAL9003 CE1N2224E / 14.01.1999 Siemens Building echnologies 4/6 Landis & Staefa Division

Notes Engineering he room temperature controller should be fitted in the main living room. he place of installation should be chosen so that the sensor can capture the room temperature as accurately as possible, without being affected by direct solar radiation or other heating or cooling sources. Mounting height is approx. 1. m above the floor. he unit can be fitted to most commercially available recessed conduit boxes or directly on the wall. Fitting and installation Commissioning When installing the room temperature controller, the base plate must first be fitted and wired. hen, the unit is engaged at the top, swung downward and secured with two screws. For more detailed information, please refer to the installation instructions supplied with the controller. For the electrical installation, the local safety regulations and standards must be complied with. he battery transit tab, which prevents inadvertent operation of the unit during transport and storage, must be removed from the batteries. he control characteristics can be changed with the help of the DIP switches located at the rear of the unit. For detailed information, please refer to the commissioning instructions. If the reference room is equipped with thermostatic radiator valves, they must be set to their fully open position. If the measured room temperature does not agree with the set room temperature on the setting knob, the detector should be recalibrated (please refer to "Calibration of detector"). Connection diagram AC 24... V L 2222A01 L1 N Y1 L Live, AC 24 V Circulating pump L1 N.O. contact, RAV11.. controller AC 24 V / 8 (3.) A N Zero Y1 Regulating unit Siemens Building echnologies CE1N2224E / 14.01.1999 Landis & Staefa Division /6

Application examples F1 F2 F2 F1 Y2 Y2 2222S01 2222S02 Instantaneous water heater Atmospheric gas burner Y1 2222S03 Circulating pump with pre-control by manual mixing valve F1 hermal reset limit thermostat RAV11.. room temperature controller F2 Manual reset safety limit thermostat Y1 Manually operated three-port valve Circulating pump Y2 Solenoid valve Dimensions 128 83, 60 37 2224M01 2224M02 4 1999 Siemens Building echonologies Ltd. Subject to alteration CE1N2224E / 14.01.1999 Siemens Building echnologies 6/6 Landis & Staefa Division