Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

Similar documents
IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Bosch Connected Control

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

Owner s Manual. 5+2 Day Programmable Digital Thermostat

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

OWNER'S MANUAL T0140. Contents Page #

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Non-Programmable Digital Thermostat

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

7-Day. Digital Thermostat. residential. & 2-cool

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Owner s Manual. Digital Thermostat

1 For All Programmable Digital Thermostat

Programmable 5-2 Day Digital Thermostat

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

5+2 Day. up to HEAT COOL

Programmable Digital Thermostat

2 - Wire Programmable Digital Thermostat

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

Installation Instructions

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

INSTRUCTION MANUAL P Heating and 1 Cooling

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Digital Refrigerator/Freezer Thermometer model 00986

Thermometer model 02059

Installation Instructions

M1200 Series Limited Warranty Dependability Promise

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

For Quick Set-Up go to Page 14

User Manual for Car Refrigerator/Freezer

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Humidity Monitor model 01080

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEU22P7S RESIDENTIAL. Model HVAC SERVICE PARTS

INSTALLATION AND OPERATING MANUAL

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

DUST FREE CARBON Whole House Air Purifier

INSTALLATION AND OPERATING MANUAL

VX SERIES Wireless Thermostat with Occupancy Sensor

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

SC Installation, Operation & Application Guide

INSTALLATION AND OPERATING MANUAL

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

Mold Alert... Operation Manual P0270

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

INSTALLATION & OPERATION MANUAL

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

AG Series Electric Heaters

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Owner s Manual. Digital Thermostat. Non-Programmable

Thermostat Remote Control & Receiver

INSTALLATION AND OPERATING MANUAL

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

OPERATING MANUAL. Need Help? This manual covers: T955WH Wireless Thermostat System. Table of Contents

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

Door/Window Sensor Installation Instructions

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

Thermometer with Wired Sensor

ACONT600AF11MA/ACONT602AF22MA Programmable Comfort Control

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

OWNE R S MA N UA L. Made in USA. September 2015

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Legacy Non-Programmable Owner s Manual

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Humidity Module OWNER S MANUAL. Complete Control from

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

1F90-60 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat (for Heat Only Systems)

professional the the the

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Horizontal Bottle Cooler Installation and Operation Manual

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Powerley Thermostat. Installation & Operation Guide

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

INSTALLATION MANUAL. Need Help? This manual covers the following models: T705. Power Type. Thermostat Applications Guide. Page.


OPERATING MANUAL. Need Help? This manual covers the following models: T915. Table of Contents

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

Jacuzzi. J- Installation and Operating Instructions

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

Transcription:

Installation Manual Thermostat Series TSTBM-RRS--TW-A Remote Temperature Sensor (Requires TSTBM3H2CPH6W-A) TSTBM-RRS--TW-A

2 TSTBM-RRS--TW-A Table Of Contents Table of Contents Thermostat Quick Reference... 3 Wireless Range... 3 Mounting Locations... 3 Remote Sensor Locations... 3 Wireless Range... 4 Mounting Options... 4 Installing Batteries... 5 Connecting to the Master Thermostat... 6 Easy Communication Link Set up... 6 Technician Setup Menu... 7 Sensor Only Mode... 9 Adjustable Remote Mode... 9 Specifications... 11 Contact Your Local Bosch Dealer... 11 Limited Warranty... 12 Warranty... 13

Mounting locations TsTbM-rrs--TW-a 3 TherMOsTaT QuiCk reference getting to know your indoor remote sensor TsTbM-rrs--TW-a Setpoint Temperature Displays the user selectable setpoint temperature. 2 3 Wireless Icon Temperature Indicates the current ambient temperature. Setpoint Adjustment Keys NOTE: The SHOW SET must be set to YES in tech setup menu before the setpoint keys will be shown in the display. Low Battery Indicator Replace batteries when this indicator is shown. 1 5 4 Clean Key Pressing the CLEAN key will allow 30 seconds to clean the display. The keys will be inoperable during this time. NOTE: The Show Set mode must be set to YES in tech setup menu before the CLEAN key will be displayed. Remote Label Each indoor remote sensor can be labeled. The label options can be found during tech setup. Run Key RUN only shows if the remote sensor setpoint has been changed. Pressing RUN will cancel the temporary setpoint hold. Note: The SHOW SET must be set to YES in tech setup menu before the RUN key will be shown in the display. 1. lcd Display 2. glow in the Dark light button* 3. Temperature setpoint buttons** 4. remote name 5. run and Clean keys** Mercury Notice: All Bosch thermostats are mercury free. However, if the product you are replacing contains mercury, dispose of it properly. Your local waste management authority can give you instructions on recycling. *NOTE ABOUT THE LIGHT BUTTON: This button is used to light up the display. DO NOT hold the light button down for longer than 3 seconds or you will enter the technician setup screens. If you inadvertently enter the tech setup press and release the light button a second time to exit the tech screens. **NOTE ABOUT SETPOINT, RUN AND CLEAN KEYS: These keys will only be shown if they have been turned on in Technician Setup menu. Wireless range Range between the TSTBM-RRS--TW-A and the TSTBM3H2CPH6W-A master thermostat is up to 100 feet with no obstructions and up to 50 feet in standard residential metal, brick, and concrete construction. MOunTing locations remote sensor locations The remote sensor should be mounted or placed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation. Do not install remote room sensors in locations that are: On an exteriorwall In direct sunlight Where there may be concealed chimneys or pipes behind the wall Close to a window or door leading outside Close to objects radiating heat such as fireplaces, lighting, space radiators, or any other appliance In areas that do not require conditioning In dead spots or where drafts can occur (behind doors or in corners) Close to hot or cold air ducts

4 TSTBM-RRS--TW-A Mounting Options Wireless Range Range between the TSTBM-RRS--TW-A and the TSTBM3H2CPH6W-A master thermostat is up to 100 feet with no obstructions and up to 50 feet in standard residential metal, brick, and concrete construction. Desk or Counter Option 1. Slide the T-bracket up into the slot holders. Mounting Options Wall Mount - Removable 1. Mount T-bracket on the Wwall. Wall mount slots 2. T-bracket will stop on the top of the slot holders. T-bracket 2. Slide the Remote Sensor over the mounted T-bracket. Wall mount slot holders. Back View of Subbase of Remote Sensor T-bracket mounted on the wall

Installing Batteries TSTBM-RRS--TW-A 5 Wall Mount - Permanent 1. Remove the TSTBM-RRS--TW-A from the subbase. 2. Once you have removed the door from the back of the remote, insert 2 AA Alkaline batteries and replace the battery door. 2. Mount subbase to the wall. Inside View of Subbase of Remote Sensor Inserting Batteries for Permanent Wall Mount 1. Remove the TSTBM-RRS--TW-A from the subbase. The TSTBM-RRS--TW-A is held on the subbase by a plastic tab on the bottom of the remote sensor. Push in with a small flat head screwdriver to remove the TSTBM-RRS--TW-A from the subbase. Installing Batteries Installing Batteries for Temporary Wall Mount or Table Placement 1. Use the finger tab on the back of the remote to remove the battery door. Bottom of Remote Sensor

6 TSTBM-RRS--TW-A Connecting to the Master Thermostat 2. Once you have removed the TSTBM-RRS--TW-A from the subbase, insert 2 AA Alkaline batteries. TSTBM3H2CPH6W-A Master Thermostat Top tabs Reset button Inside view 3. Attach the TSTBM-RRS--TW-A to the subbase by aligning the two top tabs and then close as shown. Example Step 1 TSTBM3H2CPH6W-A Remote Sensor set to YES. Then press NEXT STEP 2. Navigate the TSTBM3H2CPH6W-A to the Finding Sensors technician setup step and then select the zone you wish to connect for that remote. (See the TSTBM3H2CPH6W-A manual for instructions). TSTBM3H2CPH6W-A Master Thermostat Swing closed Connecting to the Master Thermostat Easy Communication Link Set up TSTBM-RRS--TW-A sends temperature information every 5 minutes. 1. The TSTBM3H2CPH6W-A Master Thermostat Tech setting for the Remote Sensor must be set to YES. See the TSTBM3H2CPH6W-A manual for instructions. Example Step 2 The TSTBM3H2CPH6W-A Finding Sensor zone numbers must match the zone number on the TSTBM-RRS--TW-A

Technician setup Menu TsTbM-rrs--TW-a 7 3. On the Remote Sensor TsTbM-rrs--TW-a hold the light button for 3 seconds to enter the tech setup screens. The first technician setup step is ZOne. TSTBM-RRS--TW-A Remote Sensor Wireless icon Light button 6. The TsTbM3h2Cph6W-a should now show the temperature of the remote sensor and the remote name. Your TsTbM-rrs--TW-a has now established a communication link with the TsTbM3h2Cph6W-a. TSTBM3H2CPH6W-A Master Thermostat Example Steps 3 and 5 4. Choose the zone that matches the TsTbM3h2Cph6W-a that you currently want to connect by pressing. You can only connect one TSTBM-RRS--TW-A to each zone FOR EXAMPLE: If you would like to connect two TSTBM-RRS--TW-A to the TSTBM3H2CPH6W-A, connect the first TSTBM-RRS--TW-A to ZONE 1. Connect the second TSTBM-RRS--TW-A to ZONE 2. 5. While in the ZOne tech setup step on TsTbMrrs--TW-a, hold the light button down until the wireless icon flashes, approximately 3 seconds. Example Step 6 The TSTBM3H2CPH6W-A now displays the name and the ambient temperature of the TSTBM-RRS--TW-A TeChniCian setup Menu This remote sensor has a technician setup menu for easy installer configuration. To set up the remote for your particular application: 1. Press and hold the light button for 3 seconds. This 3 second delay is designed so that homeowners do not accidentally access the installer settings. 2. Configure the installer options as desired using the following table. 3. Use the + key to move to the next tech setup screen. 4. Use the key to make adjustments to the settings. Press and release the light button when you want to exit the tech setup screens.

8 TsTbM-rrs--TW-a Technician setup Menu Once in the Tech Setup Menu, the + button rotates through the setup features while the button changes the values for that particular setting. The + button does not change the value and will take you to the next feature. Only the button will change the value. Tech setup steps Zone selection remote name show set room Temperature Calibration f or C Selects which zone is used for connecting to the TSTBM3H2CPH6W-A. Only 1 remote can be used for each zone for a total of 4 remotes. Selects a Name for the remote. This name will appear on the TSTBM3H2CPH6W-A when the TSTBM3H2CPH6W-A is displaying the remote s temperature. Enabling this feature will allow the remote to temporarily override the TSTBM3H2CPH6W-A set point. This feature allows the installer to change the calibration of the room temperature display. For example, if the thermostat reads 70 and you would like it to read 72 then select +2. This feature sets the display temperature to read in either Fahrenheit or Celsius. lcd will show adjustment Options Zone 1 Zone 2 Zone 3 Zone 4 The Zone number on the TSTBM-RRS--TW-A and the TSTBM3H2CPH6W-A must match in order to establish a connection. Remote 1, Remote 2, Remote 3, Remote 4, Bedroom 1, Bedroom 2, Bedroom 3, Bedroom 4, Kitchen, Living Room, Hall, Family Room, Dining Room, Office, Study, Den, Loft, Upstairs. N The remote is used as a sensor only and cannot change the current set point. Y Enables the temperature adjustment keys allowing the user to temporarily override the TSTBM3H2CPH6W-A set point with the TSTBM-RRS--TW-A remote. You can adjust the room temperature display to read -4 F to +4 F above or below the factory calibrated reading. F for Fahrenheit C for Celsius. factory Default settings ZONE 1 REMOTE 1 N 0 F low Temperature setpoint limit This feature allows you to set a minimum cool setpoint value. The setpoint temperature cannot be lowered below this value. Use the key to select the minimum cool setpoint. 44ºF high Temperature setpoint limit This feature allows you to set a maximum heat setpoint value. The setpoint temperature cannot be raised above this value. Use the key to select the maximum heat setpoint. 90ºF

Remote Sensor Configuration TsTbM-rrs--TW-a 9 Go to page 6 of this manual to see the instructions on how to connect the TSTBM-RRS--TW-A to the TSTBM3H2CPH6W-A Master Thermostat. Tech setup cannot be entered if the TSTBM-RRS--TW-A is in temporary hold mode. Press the RUN key to exit temporary hold. sensor Only MODe (show set tech screen set to n) In sensor only mode (set to N) the remote will not allow you to change the set point. The current ambient temperature will be displayed and transmitted to the TSTBM3H2CPH6W-A every five minutes. The ambient temperature will be used for controlling when system average is selected and whenever it is given priority by the program in the TSTBM3H2CPH6W-A. TsTbM-rrs--TW-a show set Tech set up screen The TSTBM-RRS--TW-A will show the Run key for 4 hours even if the TSTBM3H2CPH6W-A is put back in to normal operation or overridden by a 2nd remote. However, the last device changed will have priority. The last remote or master changed will have priority. TsTbM-rrs--TW-a show set Tech set up screen adjustable remote MODe (show set tech screen set to y) In show set mode it will show the temperature setpoint arrows and the CLEAN key. In this mode the TSTBM-RRS--TW-A can be used to override the TSTBM3H2CPH6W-A current settings for 4 hours in addition to being used as temperature sensor. There is no permanent hold on the TSTBM- RRS--TW-A, but you can select a permanent hold from the TSTBM3H2CPH6W-A. programming a priority for the sleep time period In this example system we have one TSTBM3H2CPH6W-A on the main floor and one TSTBM-RRS--TW-A in the Master Bedroom on the 2nd floor. During the setup process the TSTBM-RRS--TW-A was named Bedroom 1. During Wake, leave and return, the program should remain on system average. When on the sleep time period during programming, press next ZOne until Bedroom 1 shows. During the sleep time period the other remotes in the house will be ignored and the system will be controlled only by the ambient temperature of the TSTBM-RRS--TW-A in the master bedroom. The Wake, leave and return temperature will be controlled by the system average.

new features On TsTbM3h2Cph6W-a TsTbM-rrs--TW-a 10 new features On The TsTbM3h2Cph6W-a after TsTbM-rrs--TW-a is COnneCTeD next Zone key setpoint not Displayed no Display SYSTEM AVERAGE NEXT ZONE In this example, the name of the zone currently having priority is system average. System average is the average of all connected sensors. Local is the ambient temperature of the TSTBM3H2CPH6W-A. The name of the TSTBM-RRS--TW-A can be displayed. This shows it has priority. next ZOne key cycles through ambient temperatures for connected zones. Thermostat hold (permanent) hold permanent hold run schedule hold: Indicates the TSTBM3H2CPH6W-A is in permanent hold. A permanent HOLD can be active for system average, local, or any TSTBM-RRS--TW-A. run schedule: Will cancel any holds and return the system to the program. To put the thermostat into hold select system average or the zone you want to hold. Then use the arrows to adjust the setpoint. Then press the hold key. Setpoint will only be displayed for the zone currently being used by the program or in hold. Press the + or to show the setpoint for adjustment. TeMpOrary hold (4 hours) remote remote sensor run schedule remote: Indicates the TSTBM3H2CPH6W-A is in temporary hold. The setpoint will now display the temporary override setpoint. The name of the remote sensor will be displayed. In this example, it is remote 2. run schedule: Will cancel any holds and return the system to the program. If the batteries in the TSTBM-OTS--TW-A outdoor temperature sensor are low, the TSTBM3H2CPH6W-A thermostat will display a fl ashing ba and underneath will display Low bat Outdoor.

specifications TsTbM-rrs--TW-a 11 If the batteries in the TSTBM-RRS--TW-A room temperature sensor are low, the TSTBM3H2CPH6W-A thermostat will display a fl ashing ba and underneath will display the name of the room sensor that has the low battery level. The TSTBM-RRS--TW-A room temperature sensor will also indicate low battery levels by displaying the battery icon. specifications TsTbM-rrs--TW-a remote sensor The display range of temperature 32ºF to 99ºF (5ºC to 35ºC) The control range of temperature 44ºF to 90ºF (7ºC to 32ºC) Display accuracy ± 1ºF Power source Operating temperature Operating humidity Dimensions of thermostat Frequency Sending Data Reading Temperature Battery power from 2 AA Alkaline batteries 32ºF to +105ºF (0º to +41ºC) 90% non-condensing maximum 2.75 W x 4.5 H x 1.375 D 916 MHz Every 5 minutes Every 60 seconds COnTaCT your local bosch Dealer Or installing COnTraCTOr for product support. field Technical support: (954) 776-5471 bosch 601 N.W. 65th Ct. Ft. Lauderdale, FL 33309 www.bosch-climate.us

Warranty TSTBM-RRS--TW-A 12 Limited Warranty Models Covered This limited warranty is provided by FHP Manufacturing Company ( FHP ) and covers the Bosch TST Thermostat (hereinafter referred to as Product ). This warranty is provided to the original purchaser of the Product as long as the Product remains installed at its original place of installation. WARRANTY COVERAGE Limited Warranty FHP warrants that all internal components incorporated into the Product at the time of shipment by FHP shall remain free from defects in workmanship and materials for the shorter of five (5) years from proof of certificate of occupancy date, five (5) years from proof of certified start up date or six (6) years from date of manufacture provided it is installed and properly maintained by a qualified and trained HVAC contractor and the other conditions of this warranty are met. If FHP determines that the Product has a defect in workmanship or materials, FHP, at its option, will repair or replace the defective part. ITEMS NOT COVERED This limited warranty does not cover the following circumstances: 1. Components or parts not provided by FHP. 2. Components or parts on which the tags or nameplates have been removed, altered or defaced. 3. Scratches in or discoloration of finishes. 4. Serviceable items and normal maintenance as required per the Installation and Maintenance Manual. 5. The workmanship of any installer. FHP disclaims and does not assume any liability of any nature for unsatisfactory performance caused by improper installation, repair or maintenance. 6. Any labor or material costs for removal, reinstallation, repair and replacement of the defective component or part. 7. Electricity or fuel costs, or any increases or unrealized savings in same, for any reason whatsoever. 8. Damage caused by excessive temperatures or pressures, fuel or gas explosion, electrochemical reaction, water and air impurities, electrical failures, use during construction, flooding or acts of God. 9. Any damage or failure resulting from the introduction of harmful chemicals, caustic fluids, or liquids detrimental to any unit component, including but not limited to improperly applied or maintained heat transfer fluids or chlorinated pool or spa water. 10. Any damage or failure resulting from improper unit sizing. 11. Shipping charges, delivery expenses or administrative fees incurred by the purchaser in repairing or replacing the Product. CONDITIONS OF WARRANTY The warranty herein is void under the following circumstances: 1. Failure or malfunction resulting from improper or negligent operation, accident, abuse, freezing, electrical imbalance characteristics, misuse, unauthorized alteration, incorrect electrical supply, electrical surges, or improper installation, repair or maintenance. See the Installation and Maintenance Manual for installation and maintenance information. 2. Failure or malfunction resulting from any conditions within the structure, including mold and/or mildew and/or any chemical or toxin secreted there from or damage resulting from mold, fungus or bacteria. 3. Failure or malfunction resulting from a contaminated or corrosive air or liquid supply, the addition of unapproved chemicals, operation at abnormal temperatures, pressures or flow rates, opening of the refrigerant circuit by unqualified personnel or any attachment, accessory or component not authorized and approved by FHP. See the Installation and Maintenance Manual for installation and maintenance information.

Warranty TsTbM-rrs--TW-a 13 4. Failure or malfunction due to misapplication or faulty building design or construction, including inadequate refrigerant levels, condensate drain, duct work design or installation. 5. Product on which payment to FHP is or has been in default. 6. Work performed without prior authorization or approval and without authorization/requisition number and without proper documentation verifying compliance with above terms. limited WarranTy OTHER THAN THE OBLIGATIONS OF FHP EXPRESSLY SET FORTH HERIN, fhp DisClaiMs all WarranTies, express Or implied, including but not limited TO any implied WarranTies Of MerChanTabiliTy Or fitness for a particular purpose. FHP S SOLE OBLIGATION WITH RESPECT TO THE PRODUCT AND purchaser s exclusive remedies are set forth in The foregoing limited WarranTy. fhp shall not be liable for any indirect, punitive, incidental, special, COnseQuenTial Or similar DaMages INCLUDING, WITHOUT LIMITATION, INJURY OR DAMAGE TO PERSONS OR PROPERTY OR DAMAGES FOR LOSS OF USE, LOST PROFITS, INCONVENIENCE OR LOSS OF TIME. WarranTy ClaiMs process If you have a warranty claim you should notify the contractor who installed your Product and ask that the contractor notify FHP Manufacturing Company, 601 N.W. 65th Court, Ft. Lauderdale, FL 33309. To process your claim, you will need a copy of your original invoice or other proof of purchase, the product serial number and documentation showing the original installation date and location. The alleged defective components or parts must be returned to FHP in accordance with FHP procedure then in force for handling goods returned for the purpose of inspection to determine cause of failure (contact FHP if you have questions regarding the return process). If FHP determines that the returned components and/or parts are defective and that this warranty applies, FHP will furnish the repaired or replacement components and/or parts to the contractor who installed your Product. This Warranty applies to FHP products installed in the Continental United States and Canada onlyt Note that any repaired or replaced product will be warranted for only the unexpired tem of the original warranty. Some states do not allow the exclusion of limitation of damages, or limitations on how long an implied warranty lasts, so the above limitations and exclusions may not apply to you.

TSTBM-RRS--TW-A 14

TSTBM-RRS--TW-A 15

601 N.W. 65th Court, Ft. Lauderdale, FL 33309 Phone: 954-776-5471 Fax: 954-776-5529 www.bosch-climate.us