BOILERMATE A CLASS SP

Similar documents
BOILERMATE A CLASS OV

BOILERMATE 2000 USER-GUIDE SWITCH. TEL: Gas Council Approved Reference Numbers

systemate 2000 fully integrated thermal store

PULSACOIL 2000 USER GUIDE. TEL:

PULSACOIL A CLASS USER GUIDE. TEL:

PULSACOIL 2000 ELECTRIC THERMAL STORE USER INSTRUCTIONS

Operating instructions Oil condensing boiler

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Underfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

The iqe Boiler Range. Combination and System T Boilers.

GB24 & GB30. User Manual

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

Your Central Heating System

TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

TORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

User's Instructions. Alpha CB50

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Ecodan Aerocyl Plus-me: Air Source Heat Pump and Stainless Steel Cylinder

meters explained The benefits How it works Water efficiency

ADVANCE ECB ELECTRIC COMBINATION BOILER

Combi Konverter Solar System

OPERATING INSTRUCTIONS

USER GUIDE VOGUE MAX SYSTEM

Kills bills. How Vaillant technologies reduce home heating bills

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

SEDBUK Band A Gas Condensing Boilers. The Greenstar range of high efficiency gas condensing boilers from Worcester

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

CT range. of shower, bathroom and whole house pumps

Osprey 2 CFL

Installation and user manual

YourRepair Home & Boiler Cover

Operating your heating system with the Prefect PRE5701 Programable Thermostat

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

isense This could be the smartest room thermostat you ve ever used

Saving Energy. We promote equality of opportunity in every aspect of our business in line with our objectives.

CentaurPlus C21 Series 2 User Operating Instructions

3 Channel Multi-Purpose Programmer User Instructions

CentaurPlus C27 Series 2 User Operating Instructions

Daikin Altherma High Temperature User Guide

Code of Practice. Winterisation of a Caravan Holiday Home Or Holiday Lodge

Design, Installation & Servicing Instructions

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Total Hot Water Solutions

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

iheat 25c iheat 30c iheat 35c

ES3247B. 3 Channel Programmer. User and Installation Instructions

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

Installation Manual. Instrucciones de instalación y manual de usuario 1

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Baxi Maxflow Combi FS

Modern Central Heating Contents

The guarantee on this appliance is valid for 12 months from the first day of installation.

Elegance. SMT-700 User manual. Ver

SEALED THERMAL STORE

ST9400A User Guide. Features

High Output Boiler Systems

RF Programmable Room Thermostat User Instructions

Digital Room Thermostat

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

User Operating Instructions Horstmann 425 Tiara/Diadem Electro-mechanical Programmers

Installation, Operating and Servicing Instructions

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

425 Coronet Electro-mechanical Timeswitch User Operating Instructions

Water Softener. Operating Manual

Digital Electronic Thermostat With RF

Risk Assessment and Control Measures for Household Hot Water Systems

DESIGN, INSTALLATION AND SERVICE INSTRUCTIONS

Drayton Digistat +3RF

Domestic Green Deal Advice Training

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Logic+ Combi

MURELLE EV HE 25/55-30/55

103E7. User Guide. 7-Day Electronic Timeswitch for Controlling Hot Water and Heating (Including Factory Replacement Units FRU) Danfoss Heating

Baxi Maxflow Combi WM

VIESMANN. Operating instructions VITODENS 111-W. for the system user

Vokèra OpenTherm 711 without external sensor connected

EFG ENERGY OPTIMISING SYSTEMS

Daikin Altherma Small Monobloc User Guide

Gledhill High Efficiency Condensing Boiler

For use with approved Bathstore head kits. Installation guide. Viso Digital installation instructions Page 1

Vokèra OpenTherm 711 with external sensor connected

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

Energy Saving Tips. Our Top WHAM Wskazówki dotyczące oszczędzania energii nasz Top 40

USERS GUIDE 24, 30. For installation guide see reverse of book

Spring/Summer Incentives

Spring/Summer Incentives

HEATING SYSTEMS. A guide to your central heating system and helpful energy saving advice.

Slimline Curve Electric Radiator. Step by Step Programming Guide

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Transcription:

BOILERMATE A CLASS SP USER-GUIDE Gas Council Approved Reference Numbers 89-317-14 / BMA 120 SP 89-317-15 / BMA 140 SP 89-317-16 / BMA 180 SP 89-317-17 / BMA 200 SP 89-317-18 / BMA 220 SP AN SEALED CENTRAL HEATING AND MAINS PRESSURE HOT WATER SUPPLY SYSTEM INCORPORATING A THERMAL STORE ALL MODELS COMPLY WITH THE WATER HEATER MANUFACTURERS SPECIFICATION FOR INTEGRATED THERMAL STORES TEL: 0800 14 55 55 7 www.gledhill-boilermate.co.uk

Issue 2: April 2008 WELCOME TO YOUR THERMAL STORAGE SYSTEM BOILERMATE A-CLASS - THE POWER BEHIND YOUR DOMESTIC HOT WATER AND CENTRAL HEATING The hot water and central heating in your home is provided by a high specification thermal storage system coupled to a boiler which may be gas or oil. It should give you many benefits which will be explained in this leaflet. It is simple to operate and exceptionally efficient and is probably different to water heating systems that you have had previously. The Gledhill BoilerMate A-Class offers four major advantages: 1. 2... The storage vessel is designed with an electric emergency back-up for HEATING AND HOT WATER called Switch which should be activated in the event that the boiler fails. You should familiarise yourself with the emergency system when you occupy the property so that you know it is available and how it works should it ever be needed. Delivers lots of hot water at good pressures whenever you need it. It will supply heating and powerful hot water more efficiently than conventional systems. It eliminates the traditional cold water and heating tank in the loft and therefore removes the risk of contamination and/ or freezing. Page 2

It is important that if the boiler has a temperature control this should be left at its maximum for the system to operate efficiently. Traditional System Your central heating times are controlled by the central heating control rocker and timer which in most cases is fitted to the front panel of your BoilerMate. The rocker provides you with the option of having your central heating on constant, timed, or off. When the rocker is on the timed position the timer can be set to suit your individual requirements. This is the normal/recommended method of operating your central heating. The temperature in your house is set by a room thermostat/thermostatic radiator valves and these should be adjusted to suit your individual requirements. Page Your hot water is controlled by the hot water rocker and timer which in most cases is fitted to the front panel of your BoilerMate. The rocker provides you with the option of choosing constant, timed, or off. When the rocker is in the timed position the BoilerMate will only be heated at the times set on the timer. For this reason we would normally recommend that the rocker is set in the constant position. The BoilerMate is extremely well insulated and the standing loss is minimal and the boiler will ONLY fire to meet your need for hot water or heating. boilermate user instructions

The operation of Switch is explained on pages 8 and 9. It can be set for hot water only or hot water and central heating dependant on the time of year. It does cost more than gas to operate in this way which is why it is recommended that it should only be used in an emergency until the operation of the boiler is restored. WHAT IS A THERMAL STORE? The Gledhill Thermal Store is the heart and brain of your central heating system. It stores hot water at a constant temperature and incorporates a highly efficient plate heat exchanger which heats the hot water for all your domestic needs. The Thermal Store is superbly insulated and so the hot water stored has a very low heat loss. It also incorporates an intelligent sensor which determines when the temperature drops below a preset level required for optimum efficiency. When that temperature drop is detected, the Thermal Store instructs your domestic boiler to fire provided the timeclock is in an on period, generating the additional hot water needed to top up the store temperature. When the required temperature is reached, the boiler stops firing, until the next time it is required. Page

WHY SHOULD THE BOILER THERMOSTAT BE SET TO MAXIMUM? HOW DOES THE SYSTEM DELIVER WATER AT HIGH PRESSURE? The system operates most efficiently if the boiler is always left with the thermostat at its maximum setting - even in summer. This is because the intelligent electronics within the Thermal Store control the store temperature automatically. Your system should, generally, be left on if you are away for a short period. The room thermostat can be set to a low level just to prevent frost damage to your domestic pipe work systems if you wish. The water to the taps and showers in your home is delivered at high pressure because it uses the mains pressure of your cold water supply. The BoilerMate A-Class is connected to the mains system and the water passes through a highly efficient heat exchanger to raise its temperature before it travels to your taps and showers. Because it is so efficient, both high flow rates and high pressures are available to give the best performance for both baths and showers. Page boilermate user instructions

WHY ARE THERE NO WATER CISTERNS IN THE LOFT? Because the Gledhill system uses the pressure from your cold water mains, these cisterns are not required, which removes any worries about freezing or contamination of the cold water system from insects, dust, birds etc and leaves more space for storage should you decide to use it. Depending on the height of your airing cupboard it occasionally may be necessary to position the small expansion tank, for the BoilerMate itself, within the loft space e.g. in bungalows. However, normally the BoilerMate A-Class SP own feed and expansion cistern is fitted in the same cupboard as the appliance and is filled manually when the appliance is first installed. It is beneficial to check and if necessary top up the water in this cistern during the annual boiler service or if the appliance is not producing hot water. Your heating system is also filled manually from the cold water system by means of a temporary filling loop. The pressure should be at 1.0 bar when the system is cold and will rise by about 0.5 to 1.0 bar (ie to between 1.5 and 2.0 bar), dependant on the size of the system, when fully hot. The system and expansion vessel pressures should be checked and topped up at the annual boiler service or if the heating system fails. Page

CONTROLLING YOUR BOILERMATE A-CLASS Your BoilerMate is a highly advanced Thermal Storage System which incorporates the latest in microprocessor technology to monitor your system automatically and ensure it operates at maximum efficiency. This includes periodically spinning the heating pump to prevent seizing during prolonged unused heating periods. In normal circumstances, you should only be required to adjust the time clock on your Thermal Store, to suit your needs, and the instructions for this are described in detail on the label fitted to the appliance. If your hot water or heating system should fail to operate satisfactorily, you will need to operate the SWITCH option which is fitted to your BoilerMate A-Class. [See Switch at the back of this booklet] and then call a service engineer, who can then contact Gledhill Technical Department for any advice he may need As detailed previously, in order to ensure your system operates at its most efficient the boiler thermostat should always be left at maximum. Page * If you have your hot water rocker set to timed and you wish to draw a considerable quantity of hot water you will get an enhanced performance from your thermal store by setting your time clock to bring the system on 20 minutes before you want to draw the hot water. boilermate user instructions

RESETTING THE HEATING/HOT WATER PROGRAMME CLOCK This is used in conjunction with the central heating and hot water rockers to choose how and when these systems operate. Separate instructions for this will have been left for you by the installation engineer, or you can refer to the instructions on the label on the front of the appliance. U S I N G T H E U N I Q U E S W I TC H EMERGENCY ELECTRICAL BACK-UP SYSTEM Your BoilerMate A-Class is fitted with Gledhill s unique SWITCH emergency electrical back-up system. You have an instant failsafe should your boiler cease to operate. The SWITCH system will be clearly displayed on the front of your Thermal Store Appliance. In the event of a boiler failure follow the instructions left by the boiler manufacturer. If you are unable to restore heating and hot water activate the Switch and call the boiler service engineer. SWITCH technology simply and instantly introduces an electric heating source within the Thermal Store to ensure that your hot water and heating continue to operate at reduced performance until you can have your boiler repaired. Page 8

GET TO KNOW HOW SWITCH WORKS BEFORE AN EMERGENCY ARISES! We recommend that you familiarise yourself with how SWITCH works as soon as possible by following these simple steps: 1. Turn off the separate central heating boiler. 2. Press the MODE rocker to SWITCH - see diagram 1. 3. Adjust the hot water rocker to constant - see diagram 2 and the central heating rocker to off - see diagram 3. Diagram 1 4. Draw off all the hot water until it is cold at the hot tap. 5. Leave the system for one hour to allow SWITCH to reheat some of the water. 6. Run some hot water - if this is hot then SWITCH has worked successfully. Diagram 2 Diagram 3 Page 9 7. Press the MODE rocker to return it to the normal position. Adjust the hot water and central heating rockers to the required positions and then turn back on the separate central heating boiler. 8. Your hot water and central heating will now operate as normal. boilermate user instructions

Sales, Service & Repair BoilerMate A Class SP C/O Hot Water Cylinders Limited 302 Foxhunter Drive Milton Keynes MK14 6GD TEL: 0800 14 55 55 7 www.gledhill-boilermate.co.uk