i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Similar documents
USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

USER GUIDE LOGIC HEAT H

Logic+ Combi

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

USERS GUIDE 24, 30. For installation guide see reverse of book

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE MAX SYSTEM

USERS GUIDE. LOGIC+ Combi 24, 30, 35

GB24 & GB30. User Manual

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

User's Instructions. Alpha CB50

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

2 Minimiser SE - User's

Open Vented Condensing Boilers

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Baxi Maxflow Combi WM

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Baxi Maxflow Combi FS

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

iheat 25c iheat 30c iheat 35c

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

MURELLE EV HE 25/55-30/55

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

The guarantee on this appliance is valid for 12 months from the first day of installation.

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Combi Eco Elite Range. User s Guide and Important Warranty Information

24CDi, 28CDi & 35CDi II COMBI

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Osprey 2 CFL

Operating instructions

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

Greenstar 12i/24i System

Vote for your Installer of the year at HEATSLAVE

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

GREENSTAR HIGHFLOW 440/550CDi

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Operating instructions

Greenstar 12i system / 24i system

Mikrofill Ethos Condensing combination boiler

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

GREENSTAR i SYSTEM USER MANUAL WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER FOR CENTRAL HEATING SYSTEMS UK/IE (2013/08)

GREENSTAR i JUNIOR USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

GREENSTAR Ri USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER FOR CENTRAL HEATING SYSTEMS a (2010/10)

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

GREENSTAR HIGHFLOW 440/550CDi

E-COMBI EVO E-SYSTEM EVO

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Operating instructions

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

User Manual for model

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

GREENSTAR Ri ErP. User instructions UK/IE. Wall hung RSF gas fired condensing regular boiler. For central heating systems

FEB-24E UK SUPERCOMPACT COMBINATION BOILER USER MANUAL

GB24 & GB30. User & Installation Instructions BOILER OUTPUT

Greenstar 24i junior / 28i junior

WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER GREENSTAR 24i Junior/28i Junior

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Grant Vortex. Boiler House Floor Standing Condensing Oil Boiler Range User Handbook. Model shown: VTXBH3646

GB24 ErP & GB30 ErP Series II

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

VIESMANN. Operating instructions VITODENS 100-W. for the system user

WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler


User s Information Manual

E-Combi One E-System ONE

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Compact 24 SE. Standard efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. GC No

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

GREENSTAR HEATSLAVE II ErP+ 12/18, 18/25 & 25/32

User Guide. Gold Combi Condensing Combination Boiler

Index BEFORE USING THE APPLIANCE Safety Instructions... 2 Recommendations... 3 Switching On the Appliance... 4 HOW TO OPERATE THE FREEZER...

Greenstar Si Compact ErP

Transcription:

24 1 2 23 3 4 5 20 6 I 19 7 18 8 9 15 14 11 13 12 i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book i 24 OFF MAX E STATUS BURNER RESET MIN PRE MIN MAX HEAT PREHEAT MODE 22 21 0 17 16 10 UIN 212132 A05 October 2017 THESE INSTRUCTIONS TO BE RETAINED BY USER

CONTENTS 1. Introduction... 2 Safety... 2 Electricity Supply... 2 Important Notes... 2 2. Boiler Operation... 3 Controls Diagram... 3 To Start the Boiler... 3 Operation Modes... 3 Preheat Domestic Hot Water... 3 Control of Water Temperature... 3 Efficient Heating System Operation... 4 Weather Compensation... 4 Boiler Frost Protection... 4 Boiler Reset... 4 Mains Power Off... 4 3. System Water Pressure... 4 4. Condensate Drain... 4 5. General Information... 5 Boiler Pump... 5 Minimum Clearances... 5 Escape of Gas... 5 Cleaning... 5 Maintenance... 5 6. Mechanical 24 Hour Timer... 5 7. Points for the Boiler User... 6 Troubleshooting... 6 8. Normal Operation Display Codes... 7 9. Fault Codes... 8 1. INTRODUCTION The i combi is a combination boiler providing both central heating and instantaneous domestic hot water. Featuring full sequence automatic ignition and fan assisted combustion. Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe at the base of the boiler. A condensate plume will also be visible at the flue terminal. SAFETY Current Gas Safety (Installation & Use) Regulations or rules in force. In your own interest, and that of safety, it is the law that this boiler must be installed by a Gas Safe Registered Engineer, in accordance with the above regulations. In IE, the installation must be carried out by a Registered Gas Installer (RGII) and installed in accordance with the current edition of I.S. 813 Domestic Gas Installations, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation. It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler. ELECTRICITY SUPPLY This appliance must be earthed. Supply: 230 V ~ 50 Hz. The fusing should be 3A. IMPORTANT NOTES This appliance must not be operated without the casing correctly fitted and forming an adequate seal. If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes. If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII). Under NO circumstances should any of the sealed components on this appliance be used incorrectly or tampered with. This appliance can be used by children 8 years and above. Also persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, provided they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded in the Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500. Ideal is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency. THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE 2 i combi - User s

1 2 3 7 13 2. BOILER OPERATION i 24 Legend OFF MAX E STATUS BURNER A. Mode Knob B. Domestic Hot Water / Preheat Knob C. Central Heating Temperature Knob D. Boiler Status E. Burner on Indicator F. Domestic Hot Water Preheat on / off indicator G. Timer H. Pressure Gauge J. K. Condensate Drain Central Heating Economy Setting H RESET MIN PRE MIN MAX PREHEAT HEAT MODE A B C K D F 24 23 22 4 21 5 20 6 I 19 0 18 8 17 9 16 10 15 14 11 12 G E J TO START THE BOILER Start the boiler as follows: 1. Check that the electricity supply to boiler is off. 2. Set the mode knob (A) to OFF. 3. Set the Domestic Hot Water temperature knob (B) and Central Heating temperature knob (C) to MAX. 4. Ensure that all hot water taps are turned off. 5. Switch on electricity to the boiler and check that all external controls, e.g. timer and room thermostat, are on. 7. Set the mode knob (A) to (winter). The boiler will commence ignition sequence, supplying heat to the central heating, if required. Note. In normal operation the boiler status display (D) will show codes: Standby - no demand for heat. Central Heating being supplied Domestic hot water being supplied Domestic hot water preheat Boiler frost protection - boiler will fire if temperature is below 5ºC. During normal operation the burner on indicator (E) will remain illuminated when the burner is lit. Note: If the boiler fails to light after five attempts the fault code will be displayed (refer to Fault Code page). OPERATION MODES Winter Conditions - (Central Heating and Domestic Hot Water required) Set the mode knob (A) (winter). The boiler will fire and supply heat to the radiators but will give priority to domestic hot water on demand. The domestic hot water preheat will operate if preheat is enabled (shown by indicator light (F)). Summer Conditions - (Domestic Hot Water only required) Set the mode knob (A) to (summer). Set the central heating demand on the external controls to OFF. The domestic hot water preheat will operate if preheat is enabled (shown by indicator light (F)). Boiler Off Set the mode knob (A) to OFF. The boiler mains power supply must be left on to enable frost protection (see Frost Protection). PREHEAT - DOMESTIC HOT WATER The domestic hot water heat exchanger within the boiler can be kept preheated to provide faster delivery of hot water at the tap. Preheat is enabled when the preheat indicator (F) is lit. To switch preheat on or off, move the domestic hot water preheat knob (B) full clockwise and then return it to the required domestic hot water temperature setting. The boiler will operate periodically for a few seconds to maintain the domestic hot water heat exchanger in a preheated condition. The average time period between operation is 90 minutes. This may vary considerably due to the surrounding ambient temperature of the boiler. The boiler will operate whenever there is a demand for domestic hot water. If standard hot water delivery is satisfactory turn the knob (A) to OFF. CONTROL OF WATER TEMPERATURE Domestic Hot Water The domestic hot water temperature is limited by the boiler controls to a maximum temperature of 64 º C, adjustable via the domestic hot water temperature knob (B). Approximate temperatures for domestic hot water: Knob Setting Hot Water Temperature (approx.) Minimum 40ºC (104ºF) Maximum 64ºC (147ºF) Due to system variations and seasonal temperature fluctuations domestic hot water flow rates/temperature rise will vary, requiring adjustment at the tap : the lower the flow rate the higher the temperature, and vice versa. Central Heating The boiler controls the central heating radiator temperature to a maximum of 80 o C, adjustable via the central heating temperature knob (C). Approximate temperatures for central heating: Knob Setting Minimum Maximum Central Heating Radiator Temperature (approx.) 45ºC (113ºF) 80ºC (176ºF) For economy setting E refer to Efficient Heating System Operation. i combi - User s 3

EFFICIENT HEATING SYSTEM OPERATION The boiler is a high efficiency, condensing appliance which will automatically adjust its output to match the demand for heat. Therefore gas consumption is reduced as the heat demand is reduced. The boiler condenses water from the flue gases when operating most efficiently. To operate your boiler efficiently (using less gas) turn the central heating temperature knob (C) to the E position or lower. In winter periods it may be necessary to turn the knob towards the MAX position to meet heating requirements. This will depend on the house and radiators used. Reducing the room thermostat setting by 1ºC can reduce gas consumption by up to 10%. WEATHER COMPENSATION When the Weather Compensation option is fitted to the system then the central heating temperature knob (C) becomes a method of controlling room temperature. Turn the knob clockwise to increase room temperature and anti-clockwise to decrease room temperature. Once the desired setting has been achieved, leave the knob in this position and the system will automatically achieve the desired room temperature for all outside weather conditions. BOILER FROST PROTECTION The boiler is fitted with frost protection that operates in all modes, provided the power supply to the boiler is always turned on. If the water in the boiler falls below 5ºC, the frost protection will activate and run the boiler to avoid freezing. The process does not guarantee that all other parts of the system will be protected. If a system frost thermostat has been installed, the boiler must be set in winter mode,, for the system frost protection to run. If no system frost protection is provided and frost is likely during a short absence from home it is recommended to leave the system heating controls or built in programmer (if fitted) switched on and run at a reduced temperature setting. For longer periods, the entire system should be drained. BOILER RESET To reset the boiler, when directed in the listed fault codes (see section 9), turn the mode knob (A) to reset position and IMMEDIATELY turn knob back to required setting. The boiler will repeat its ignition sequence. If the boiler still fails to start consult a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII). MAINS POWER OFF To remove all power to the boiler the mains power switch must be turned off. 3. SYSTEM WATER PRESSURE The system pressure gauge (H - see page 3) indicates the central heating system pressure. If the pressure is seen to fall below the original installation pressure of 1-2 bar over a period of time and continue to fall then a water leak may be indicated. In this event repressurise the system. If unable to do so or if the pressure continues to drop a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be consulted. THE BOILER WILL NOT OPERATE IF THE PRESSURE HAS REDUCED TO LESS THAN 0.3 BAR UNDER THIS CONDITION. 4. CONDENSATE DRAIN This appliance is fitted with a siphonic condensate trap system that reduces the risk of the appliance condensate from freezing. However should the condensate pipe to this appliance freeze, please follow these instructions: a. If you do not feel competent to carry out the defrosting instructions below please call your local Gas Safe Registered installer for assistance. b. If you do feel competent to carry out the following instructions please do so with care when handling hot utensils. Do not attempt to thaw pipework above ground level. If this appliance develops a blockage in its condensate pipe, its condensate will build up to a point where it will make a gurgling noise prior to locking out an L2 fault code. If the appliance is restarted it will make a gurgling noise prior to it locking out on a failed ignition L2 code. To unblock a frozen condensate pipe; 1. Follow the routing of the plastic pipe from its exit point on the appliance, through its route to its termination point. Locate the frozen blockage. It is likely that the pipe is frozen at the most exposed point external to the building or where there is some obstruction to flow. This could be at the open end of the pipe, at a bend or elbow, or where there is a dip in the pipe in which condensate can collect. The location of the blockage should be identified as closely as possible before taking further action. 2. Apply a hot water bottle, microwaveable heat pack or a warm damp cloth to the frozen blockage area. Several applications may have to be made before it fully defrosts. Warm water can also be poured onto the pipe from a watering can or similar. DO NOT use boiling water. 3. Caution when using warm water as this may freeze and cause other localised hazards. 4. Once the blockage is removed and the condensate can flow freely, reset the appliance. (Refer to To Light the boiler ) 5. If the appliance fails to ignite, call your Gas Safe Registered engineer. Preventative solutions During cold weather, set the central heating temperature knob (C) to maximum, (Must return to original setting once cold spell is over). Place the heating on continuous and turn the room thermostat down to 15ºC overnight or when unoccupied. (Return to normal after cold spell). 4 i combi - User s

5. GENERAL INFORMATION BOILER PUMP The boiler pump will operate briefly as a self-check once every 24 hours, regardless of system demand. 6. MECHANICAL 24 HOUR TIMER Align current time to arrow MINIMUM CLEARANCES Clearance of 165mm (6 1 /2 ) above, 100mm (4 ) below, 2.5mm (9 1 /8 ) at the sides and 450mm (17 3 /4 ) at the front of the boiler casing must be allowed for servicing. Bottom Clearance Bottom clearance after installation can be reduced to 5mm This must be obtained with an easily removable panel, to enable the system pressure gauge to be visible and to provide the 100mm clearance required for servicing. Timer Control Permanently OFF 6 7 8 5 4 3 2 1 24 Permanently ON 23 22 21 20 19 18 Time & Control Indicator ON PERIOD ESCAPE OF GAS Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay. Telephone 0800 111 999. Ensure that; - All naked flames are extinguished - Do not operate electrical switches - Open all windows and doors CLEANING For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth. DO NOT use abrasive cleaning materials. MAINTENANCE The appliance should be serviced at least once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII). ON PERIOD 9 10 11 12 13 SETTING UP The outer dial should be set to the current time. Rotate the dial slowly in a clockwise direction, until the correct hour is aligned with the arrow printed on the dial. Note that the outer dial is printed with the 24hr clock e.g. 8.00am = 8 on the dial, 8.00pm = 20 on the dial. Do not attempt to rotate the dial in an anti-clockwise direction. PROGRAMMING SWITCHING TIMES Set tappets to outer edge for ON periods and set tappets to inner edge for OFF periods. 14 15 16 17 The example shown has been set with 2 on periods. ON at 9.00am. OFF at 1.00pm. (13 hours) ON at 6.00pm. (18 hours) OFF at 10.00pm (22 hours) Manual Switch Operation To set the timer for timed operation move the switch to the TIMED position. To set the timer to be continuously on, move the switch to the MANUAL ON position. To set the timer to be continuously off, move the switch to the MANUAL OFF position. Note. If boiler does not light when in timed on or manual on position, increase temperature on room stat. i combi - User s 5

7. POINTS FOR THE BOILER USER Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer. TROUBLESHOOTING NO HOT WATER NO CENTRAL HEATING NO HOT WATER OR CENTRAL HEATING Check the mains power is turned on and ensure mode knob (A) is in the summer or winter position Check the mains power is turned on and ensure mode knob (A) is in the winter position Check the mains power is turned on and ensure mode knob (A) is in the winter position Is water coming out of the hot water tap when turned on? YES NO Check the timer is in an ON position and the room thermostat is turned up Does the boiler have a display showing on the front control panel? NO See boiler Fault Codes section. If 0 is displayed then contact Ideal Customer Services Helpline if your appliance is under warranty or a Gas Safe Registered Engineer, in IE a Registered Gas Installer (RGII), if out of warranty Does the boiler operate and provide central heating? YES Check the time settings on the timer are as you require and adjust if necessary NO YES See boiler Operation Modes and Fault Codes section Contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) Contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) See boiler Operation Modes and Fault Codes section. If 0 is displayed then contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) 6 i combi - User s

8. NORMAL OPERATION DISPLAY CODES DISPLAY CODE ON BOILER DESCRIPTION The boiler is in standby mode awaiting either a central heating call or hot water demand. The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler. The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler. The boiler is operating in central heating mode. The boiler is operating in hot water mode. The boiler is operating in pre heat mode. The boiler is operating in frost mode. continued...... FOR ANY QUERIES PLEASE RING THE i COMBI CONSUMER HELPLINE : 01482 498660 NOTE. BOILER RESET PROCEDURE - To reset boiler, turn mode control knob to reset position and immediately turn knob back to required setting. continued...... i combi - User s 7

9. FAULT CODES DISPLAY CODE ON BOILER DESCRIPTION ACTION BCC Activation Fault BCC Fault Low Water Pressure Check system water pressure is between 1 & 1.5bar on the system pressure gauge (G). To re-pressurise the system see Section 3. If the boiler still fails to operate then please contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty Flame Loss Fan Fault 1. Check other gas appliances in the house are working to confirm a supply is present in the property. 2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty Flow Thermistor Return Thermistor Outside Sensor Failure Low Mains Voltage Contact a qualified electrician or your electricity provider. Unconfigured PCB Unconfigured PCB. Please contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Flow Temperature Overheat or No Water Flow Check system water pressure is between 1 & 1.5bar on the system pressure gauge (G). To re-pressurise the system see Section 3. If the boiler fails to operate then please contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty Flame Loss 1. Check other gas appliances in the house are working to confirm a supply is present in the property. 2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 5 Boiler Resets in 15 minutes 1. Turn electrical supply to boiler off and on. 2. If the boiler fails to operate please contact Ideal Boilers (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). False Flame Lockout 8 i combi - User s