UHV Flow Cryostats. Ultra High Vacuum Flow cry stats CRYO INDUSTRIES

Similar documents
2-Stage 4 K Closed Cycle Refrigerator Systems

2-Stage 4 K Closed Cycle Refrigerator Systems

Applications and Accessories, Cryo Pumps

Cryopumps, Cryogenics

3.5 Cryosurface & Cryogenic Feed-through Specification

Cryogenics for Neutral Beam Injector System

D R A F T. Testing of performance of precooling refrigerator in the fill/vent line at Indiana. Revision: 0.00

Fiber Optics. VIS / NIR Multimode, Feedthroughs. Ultrahigh Vacuum CF Flange Feedthrough. 4 x 1 CF Flange Feedthrough

Concept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage

COOLVAC

Fast Cycle Water Vapor Cryopump

4.8 FARADAY CUP ASSEMBLY OPTION

The dilution process. 4K flange. Still. Heat exchangers. Mixing chamber

Fast Cycle Water Vapor Cryopump

SpinTron 2: 2-inch High Vacuum Magnetron Sputter Source Product Installation and Use

2016 Ideal Vacuum (505) V 1.1

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

VACUUM VALVES AND HOSES

Variable Temperature Microprobe Systems

Vacuum Insulated Pipe

thermal management features such as temperature setpoint control, temperature ramp rate control, and process heating.

INNOVATIVE WATER VAPOR CRYOPUMP TECHNOLOGIES PRODUCT CATALOG

Instruction Manual. B Issue B. next Pump Accessories

W A T L O W. Straight Resistance Wire. Welded End Cap

Vacuum Equipment. Manifolds. Traps. Pumps. Adapters. Easy to assemble Ace-Safe connector versions. O-Ring connections. Added safety and versatility

Pocket Dilution Cooler

Modifications and Improvements to the NPDGamma Liquid Hydrogen Target System and Safety

W A T L O W. Straight Resistance Wire. Welded End Cap

Scientific vapor pumps

A Microcryostat for Refrigeration at 1.8 K

Varian, Inc. Vacuum Technologies. Diffusion Pumps. Feature and Benefits Typical Applications Pump Models

Thermal Vacuum Cycling Test Facility for the Qualification of Near Sun Missions Solar Panels

AGILENT ION PUMP 200 The first ion pump with maximum pumping speed at low pressure

DART-Thermo LTQ/Orbitrap Interface Manual

Design and Operation of a Cryogenic Nitrogen Pulsating Heat Pipe

Final Design Report. for the M.I.C.E. 2 slot VLPC Cryocooler Cryostat

Custom Products Gallery

What is an Integrated Detector Assembly? Aron Traylor. College of Optical Sciences The University of Arizona 29 November 2010.

1.0 Denton Thermal Evaporator

3.2 Cryoplant and Cryodistribution

Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK

DESIGN STANDARDS SECTION 15600

Description of the Ortho-to-Para Convertor and Internal Plumbing of the Hydrogen Target

LEIDEN CRYOGENICS BV

VacIon Plus 150. Outline Drawing. Technical Specifications. Dimensions: millimeters (inches) 6" O.D. CFF (NW100) (1.88) REF (14.

TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER

XFEL Collimation and Beam Switchyard Vacuum Issues

SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION

92831 TEL: (714) FAX:

Liquid Helium Level Instruments

SERVICE MANUAL FOR MODEL RM-10

REVISION NO. 1 DATED SEPT 20/10 HIGHLIGHTS

MVE Chart Tech Tips PRODUCT INFORMATION MVE205AF GB

VacIon Plus 20. Outline Drawing. Technical Specifications

INLET PRESSURE - TORR

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

cooled, Non-heated ATH 1603 M, DN 200 CF-F, External drive electronics, Water cooled, Non-heated

Ulster Bank Business Achievers Award Emerging Technology

Cartridge. SORB-AC Cartridge Pumps MK5 Series. Pump Body. Heater. Thermocouple. Flange. Electrical Connector

Model MTD-120/121 Modular Test Dewar Cryotest System

Kurt J. Lesker in the Cryogenic Community. Dr. Glynn Dyson Cryogenics Cluster Day 19 th September 2014

PRODUCT OVERVIEW. Precision and Vacuum Technology.

ZD-985 Desoldering Station

EarthLinked Series PHXTI Pool Heat Exchangers Installation Manual

Maintenance and Reliability Design Aspects SNS 2K Refrigeration System

Water Circulator (Chiller) & Cold Trap

Owner s Manual. Terpene Trap CF 1000

CHASE RESEARCH CRYOGENICS Ltd. World Leaders in sub-kelvin cryogenics

MODEL CMA-180UC PARTS MANUAL Rev 1.18

Tech Tips (December 2016) Product Information

MODEL CMA-180UC PARTS MANUAL Rev 1.16

Variable Temperature Options for Optical Experiments

Karlsruher Glastechnisches Werk KGW-ISOTHERM

Ultra-sorb Models LV and LH

Vacuum Quality Assurance in Practice

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

Recirculating Coolers

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

F-T, FT-P, F-L AND F-P SERIES

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Table of Contents. Check the LCLS Project website to verify 2 of 12 that this is the correct version prior to use.

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Technology for Vacuum Systems. Instructions for use

A n hybrid liquid nitrogen system for the cooling. of the ESO O mega C A M detector

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

ELD500 PRECISION LEAK DETECTOR

SERVICE MANUAL FOR MODEL RM-26

Owner s Manual Therma-Stor II Heat Recovery System

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

Ion Pump Evolution. VacIon Plus. Titanium Sublimation Combination Pumps (TSP)

Varian, Inc. Vacuum Technologies. Diffusion Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models Fluids

Vickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

Installation Manual PS-200 & PS-201

Scotsman Technical Training. CU50 Cube Ice Machine

Cartridge Heaters. Components. Application Guidelines

Thermo-Finnigan LCQ Interface Manual

Transcription:

UHV Flow Cryostats Ultra High Vacuum Flow cry stats INDUSTRIES

Ultra High Vacuum Flow Cryostats: Models RC-102 and RC-110 Cryo offers Models RC-102 and RC-110 Ultra High Vacuum continous flow cryostats, which feature rotatable Conflat interface flanges, your choice of 2.75, 4.50 or 4.62 etc.. Distance from chamber interface to cold finger can be selected to fit exactly your chamber. Constructions is all welded stainless steel with low vapor pressure silver brazed copper joints. The Model RC-110 offers the most advanced technology, resulting in better temperature stability. This is achieved with the addition of an internal metallized phase seperator which eliminates all temperature fluctuations. The Model RC-110-UHV has a heater assembly built on the end of the transfer line. This heater is not exposed to vacuum and is instantly accessible. (Note: The phase seperator is not installed in this model). An optional heater that mounts directly to the inside of the sample mount is available for the model RC102; this heater is accessible through a mini Conflat flange. The standard variable temperature continuous flow ultra high vacuum cryostat Models RC-102 and RC-110 feature the following: Operates with either Cryogen-10K Cryogenic Generator or Liquid Helium dewar Sample in ultra high vacuum (UHV) 4.5 inch rotateable conflat flange 1.00 inchy diameter copper sample mount with (6) #4-40 tapped holes on 0.75 diameter BC Vapor cooled radiation shield Hi Power (50 Ohm) heater installed on sample mount 0.62 inch O.D. helium vent/return port Temperature Range: Cooldown Time: Cooldown Consumption: Cryogen Consumption: Refrigeration Capacity: Temperature Stability: Orientation: Specifications (2-4) 1.33 inch mini conflat feedthrough ports (depending on style) Evacuation valve with NW25 interface flange Safety pressure relief on vacuum space Flexible stainless steel transfer line with flow control valve for operation with LHe dewar Silicon Diode Temperature Sesnor- bolt on style installed on sample mount <1.8-300 K (600 K optional) 10 minutes typical from 300 to 4.2 K (helium) 8 minutes typical from 300 to 77 K (nitrogen) 0.20 liters liquid helium from 300 to 4.2 K 0.55 liters/hour (helium) at 4.2 K for RC-102 0.75 liters/hour (helium) at 4.2 K for RC-110 Lower at higher temperatures 0.075 liters/hour (nitrogen) at 77 K Over 2 watts at 4.2 K 0.05 K for RC-102 0.005 K for RC-110 Any Position

Standard Model RC-102 UHV WITH NW-25 0.62 O.D. FLOW VALVE CONTROL KNOB CONTROL TUBE AND (4) 1.33 MINI CONFLAT PORT 4.50 (4.62 or 2.75 OPTIONAL) ROTATABLE CONFLAT FLANGE 48.00 1.0 O.D. 12.0 or 0.37 O.D. 2.31 DIA. VAPOR COOLED RADIATION SHIELD 1.50 I.D. WITH (6) #4-40 TAPPED HOLES ON A 0.75 DIA BC PROPRIETARY INFORMATION IS THE SOLE PROPERTY OF TITLE: MODEL RC102-UHV

Standard Model RC-110 UHV EVACUATION VALVE WITH NW-25 FLANGE PHASE SEPARATOR REGULATOR FLOW VALVE CONTROL KNOB LIQUID HELIUM FLOW VALVE CONTROL TUBE AND (4) 1.33 MINI CONFLAT PORT 48.00 4.50 O.D. ROTATABLE CONFLAT FLANGE (OTHER SIZE CONFLATS OPTIONAL) 1.0 O.D. HELIUM INNER TRANSFER 12.0 OR 2.31 DIA. THERMAL ANCHOR WITH WIREWAYS 12.0 OR 1.50 I.D. VAPOR COOLED RADIATION SHIELD (OPTIONAL) WITH (6) #4-40 TAPPED HOLES ON A 0.75 DIA BC PROPRIETARY INFORMATION IS THE SOLE PROPERTY OF TITLE: MODEL RC110-UHV

Model RC-102 UHV 4-PIN ELECTRICAL FEEDTHROUGH WITH NW-25 VALVE CONTROL KNOB CONTROL TUBE (4) 1.33 MINI CONFLAT PORT 4.50(4.62 or 2.75 OPTIONAL) ROTATABLE CONFLAT FLANGE 48.00 1.0 O.D. 12.00 or 1.88 DIA. SINGLE THREAD INTERFACE VAPOR COOLED RADIATION SHIELD WITH (6) #4-40 TAPPED HOLES ON A 0.75 DIA BC NOTE: THIS STYLE RC-110 IS A NON-PHASE SEPERATOR DESIGN PROPRIETARY INFORMATION TITLE: MODEL RC102-UHV IS THE SOLE PROPERTY OF ULTRA HIGH VACUUM

Model RC-102 UHV WITH NW-25 10-PIN ELECTRICAL FEEDTHROUGH FOR HEATER AND TEMP. SENSOR 10-PIN ELECTRICAL FEEDTHROUGH FOR HEATER AND TEMP. SENSOR VALVE CONTROL KNOB (3) BLANK 1.33 MINI CONFLAT PORTS CONTROL TUBE 4.50 ROTATABLE CONFLAT FLANGE 48.0 0.75 O.D. 12.00 2.31 O.D. 1.62 O.D. VAPOR COOLED RADIATION SHIELD 4.000 1.00 1.750 (2) 1.33 MINI CONFLAT FLANGES FOR ACCESS TO HEATER AND SENSOR WITH (4) #4-40 TAPPED HOLES ON A 0.75 DIA BC PROPRIETARY INFORMATION IS THE SOLE PROPERTY OF TITLE: MODEL RC102 ULTRA HIGH VACUUM

Example of Custom RC-110 UHV with 72 inch Leg 72.0" MIN. HOSE WITH NW-25 10-PIN ELEC. FEEDTHRU FOR INTERNAL HEATER AND SENSOR VALVE CONTROL KNOB ROTATABLE QUICK 1.50 CONNECT SEAL WITH NW40 FLANGE 10.50 (266.7mm) WITH NW16 FLANGE 30 30 TYP. TYP. (1) 10 PIN ELECTRICAL UHV FEEDTHRU CONTROL TUBE.394 (10mm) 2.69 (68.3mm) 4.50 O.D. (114.3mm) 2.95 (75mm) (1) 1.33 DIA. TAPPED CONFLAT FLANGE (5) 1.33 DIA. TAPPED CONFLAT FLANGES SPACED AS SHOWN ON A 3.50 DIA. B.C. 70.0 (SPECIAL LENGTH) 0.86 (21.9mm) 2.37 I.D. (60.2mm I.D.) 0.75 (19.1mm) 4.50 O.D. ROTATABLE CONFLAT FLANGE 39.10 (993.1mm) A 1.00 O.D. (25.4mm) 2.05 O.D., (8) M3 TAPPED HOLES ON A 1.81" (46mm) B.C., ALSO HAS (3) 1mm I.D. HOLES ON A 34mm B.C. (120 DEGREES APART) A VIEW A-A (3) 1mm (.039") DIA HOLES EQ. SP. ON A 34.0mm B.C NOTE: HOLES TO ORIENT WITH M3 TAPPED HOLES ON THE SAMPLE MOUNT AS SHOWN IN VIEW B-B 6.00 (2) 1.33 MINI CONFLAT FLANGES FOR ACCESS TO HEATER AND SENSOR VIEW B-B B B WITH INTERNAL HEATER AND SENSOR, EXTERNAL SENSOR AND (8) M3x.5 TAPPED HOLES ON A 19.05mm DIA. B.C. PROPRIETARY INFORMATION TITLE: IS THE SOLE PROPERTY OF MODEL RC110-UHV ULTRA HIGH VACUUM <2 K to 325 K operating temperature range Operates with liquid helium or liquid nitrogen Operates in Push or Pull modes Heater installed inside sample mount (Not in UHV) Total of (6) UHV (16 CF) tapped conflat ports Customized number of UHV feedthrough ports with mate Customized addition of gas inlet port Copper radiation shield interface flange Bakeable to 200 C System Features Include: Vacuum insulated LHe transfer line with activated charcoal cryopump, ice filter and flow control valve Size of rotatable conflat interface flange is customized Distance from conflat flange to sample mounting surface is customized Constructed of non-magnetic stainless steel SD Silicon Diode temperature sensor installed on sample mount (on UHV side) Fully integrated and liquid helium tested