GROHTHERM 3000 COSMOPOLITAN DESIGN + ENGINEERING GROHE GERMANY /ÄM / GB

Similar documents
Grohtherm 1000 Cosmopolitan. Grohtherm 1000 Cosmopolitan. Design + Engineering GROHE Germany /ÄM /01.14

EUROSMART DESIGN + ENGINEERING GROHE GERMANY /ÄM /

ESSENCE PROFESSIONAL PULL DOWN SINK MIXER MODEL # Product Specifications. Product description

Vitalio System. Design + Engineering GROHE Germany /ÄM /04.14

TEMPESTA COSMOPOLITAN 100MM 4 FUNCTION HAND SHOWER MODEL # Product Specifications

Eurodisc SE. Eurodisc SE

RAINSHOWER SYSTEM SMARTCONTROL 360 DUO MODEL # Product Specifications. Product description

GROHE RED MONO Made in Germany

GROHE Red Duo. Design + Engineering GROHE Germany /ÄM /04.14

Grohtherm Grohtherm 1000

Grohtherm 1000 Cosmopolitan. Grohtherm 1000 Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /06.12

book : T95548.FM Seite 1 Montag, Oktober 11, :01 AM

Grohtherm Grohtherm 1000

Eurosmart Cosmopolitan. Eurosmart Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /10.11

Eurosmart FIN EST SLO RUS UAE Eurosmart Design & Quality Engineering GROHE Germany

Grohtherm Wireless! Installation Instructions Pumped High Pressure

RAINSHOWER SMARTCONTROL DESIGN + ENGINEERING GROHE GERMANY

Linear FIN EST SLO RUS UAE Lineare Design & Quality Engineering GROHE Germany

s y ens Av Avensys FIN EST RUS SLO RUS UAE

Avensys Avensys FIN EST SLO RUS UAE

Avensys Avensys FIN EST SLO RUS UAE

Grohtherm Wireless! Installation Instructions Pumped

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

Installation and converting instructions to another gas type T4530, T4650

Deluge Shower Mixing Valve 10045CP

Inta City Shower Mixing Valve CT20010CP

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

Mio Concealed Shower Mixing Valve MI40010CP

Telo Shower Mixing Valve TL10016CP

Deluge Concealed Shower Mixing Valve DL40010CP

Plus Bath Shower Mixing Valve CP and PL30020CP

Enzo Concealed Shower Mixing Valve

Kiko Concealed Shower Mixing Valve KK80010CP

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Kiko Bath Shower Mixing Valve KK90015CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Inta City Concealed Shower Mixing Valve CT80010CP

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

TIMES SQUARE TWO-HANDLE THERMOSTAT

Puro Mini Dual Control Shower Mixer PU90010CP

Thermostatic bar mixer valve with adjustable head Installation guide

Ambassador. Installation guide & user instructions. Please ensure that this document is handed to the user after installation is completed

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Thermostatic Concealed Shower Valve

LD200 / RLD400 LD200-G /RLD400-G

Intelligent Technology and Timeless Design

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

OBLO USER MANUAL.

Varsity Concealed Shower System

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Traditional Rigid Riser With Eight Inch Rose

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2010/52

THAMES. Dual Control. Installation and Operating Instructions. Thermostatic built-in mixer shower

Mira Realm Thermostatic Mixer

INSTALLATION FOR THERMOSTATIC VALVES

Installation manual Washer extractor

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Mimosa dual control mixer shower Installation and operating instructions

MIRA SELECT THERMOSTATIC MIXER INSTALLATION & USER GUIDE. These instructions must be left with the user. 1. Please call us on (UK Only)

SecurWATCH IP. The safety net for disoriented persons with intelligent additional functions HEALTH CARE

TYNE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

INSTALLATION INSTRUCTIONS

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Alcor dual control mixer shower

These instructions are to be left with the user

These instructions must be left with the user.

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

INSTALLTION FOR THERMOSTATIC VALVES

Thames thermostatic bar mixer with diverter Installation and operating instructions

TEPZZ 9Z5549A T EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: F24F 1/06 ( ) F24F 1/46 (2011.

Miele built-in appliances - Warming drawers

Dene Bath Shower Mixer

Thermostatic Valve and Trim

Dove Eco thermostatic bar mixer shower

SAGV x 1/1 GN 7-12 x 20 COMBI STEAMER FOR GASTRONOMY

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

Dart Eco concentric thermostatic mixer shower

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: G08B 17/06 ( ) G08B 17/103 (2006.

MINI ME USER MANUAL.

Delphi dual control thermostatic mixer shower Installation and operating instructions

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

EDEN Concentric Thermostatic Mixer Shower

Caroli dual control thermostatic mixer shower Installation and operating instructions

MINIATURE THERMOSTATIC VALVE

INSTALLATION INSTRUCTIONS

Installation Instructions

TYNE. Installation and Operating Instructions. Thermostatic bath shower mixer. Installers please note these instructions are to be left with the user

HUMBER Dual Control Mixer shower Installation and operating instructions

Installation Instructions

THAMES single lever built-in thermostatic mixer valve

Installation manual Tumble dryer

JOVIA USER MANUAL.

Integral X-LINE. Security without boundaries. FIRE ALARM.

Installation, Operating and Maintenance Guide

Transcription:

GROHTHERM 3000 COSMOPOLITAN DESIGN + ENGINEERING GROHE GERMANY 96.514.031/ÄM 235698/02.16 www.grohe.com GB...1...14

Please pass these instructions on to the end user of the fitting. I

1 a b c x 2 7 8 1/2 29 800 y D J ø 15mm 29 801 C K 3/4 29 802 z ø 18mm 29 803 L 4 9 10 ø 22mm 29 804 3 M2 N P O B M1 B M 5 6 11 12 min. Q max. G F E 8mm D C 27mm O R S1 S H II

GB Safety notes Protection against scalding It is recommended that near points of discharge with particular sensitivity to the outlet temperature (hospitals, schools, nursing and retirement homes) thermostatic devices should be installed which can limit the water temperature to 43 C. The product includes an appropriate temperature end stop. It is generally recommended that the temperature of shower-systems should not exceed 38 C in nurseries and specific areas of care centres. Use Grohtherm Special thermostats with special handle to facilitate thermal disinfection and appropriate safety end stop. Applicable standards (e. g. EN 806-2) and technical regulations for drinking water must be observed. Application Thermostat mixers are designed for hot water supplies from pressurised storage heaters and offer the highest temperature accuracy when used in this way. Given sufficient output (min. 18 kw or 250 kcal per min), electric or gas-fired instantaneous heaters are also suitable. Thermostat mixers cannot be used in conjunction with lowpressure storage heaters (displacement heaters). All thermostat mixers are adjusted at the factory at a flow pressure of 3 bar on both sides. The built-in thermostat only shuts off the upper outlet. An additional stop valve must be fitted if the lower outlet is used. For an order number index to the various installation components for the concealed mixer, see fold out page II fig. [1]. a = Size of union b = Part c = Part No. - Observe the installation depth in accordance with the instructions given on the mounting template, see also fold out page II fig. [2]. x = Face of tiles y = Front face of mounting template z = Resting point for spirit level - Align the mixer horizontally, vertically and parallel to the wall, see fig. [3] (place a spirit level on the cams or face of the mounting template). - Install concealed thermostat mixer module in wall and connect pipelines, see fig. [4]. The housing is provided with pre-drilled holes (B) to facilitate mounting the fitting to the wall, see fig. [3]. - Do not solder the connections between the pipelines and housing, otherwise the built-in non-return valves may be damaged. - Seal the open outlet with screw plug. Note! - The hot water supply must be connected on the left (marked W (H) on housing) and the cold water supply on the right (marked K (C) on housing), as viewed from the operating position. Open cold and hot water supplies. Test the pipelines and concealed thermostat module connections for leaks. Flush pipelines thoroughly. Technical Data Minimum flow pressure without downstream resistances 0.5 bar Minimum flow pressure with downstream resistances 1 bar Max. operating pressure 10 bar Recommended flow pressure 1-5 bar Test pressure 16 bar Flow rate at 3 bar flow pressure approx. 24 l/min Max. water temperature at hot water inlet 80 C Recommended max. flow temperature 60 C (for energy saving) Safety stop 38 C Hot water temperature at supply connection min. 2 C higher than mixed water temperature. Hot water connection - W - (-H-) left Cold water connection - K - (-C-) right Minimum flow rate 5 l/min 1. Remove screws (C) and mounting template (D), see fig. [5]. 2. Close the hot and cold water supplies. 3. Remove screw plug (E). 4. Remove non-return valve (F) and filter (G). 5. Install flushing plugs (H) in non-return valve seat recesses, see fig. [6]. 6. Open the hot and cold water supplies and flush pipes thoroughly. 7. Close the hot and cold water supplies and remove flushing plugs (H). 8. Install filter (G) and non-return valve (F), see fig. [5]. 9. Install screw plug (E). 10. Reinstall mounting template (D). Plaster and tile the wall, excluding the area occupied by the mounting template. Seal any apertures in the wall so that they are watertight to spray water. At a flow pressure over 5 bar it is recommended that a pressure reducing valve be fitted in the supply line. New installations - Prepare wall ready for mixer. Drill holes for thermostat mixer and chase-out grooves for pipelines. Tiles laid in mortar should be pointed so that the joint is tapered towards the outside. Seal prefabricated walls with a permanently plastic compound. Do not remove the fitting template before final installation. 1

Final installation 1. Remove screws (C) and mounting template (D), see fig. [7]. 2. Install holder (J) and fit sleeve (K) and (L), see fig. [8]. 3. Grease the seals (M1) for the escutcheon mounting bracket (M2) with the special grease supplied and install escutcheon mounting bracket (M2) with srews (N), see fig. [9]. 4. Fit the escutcheon (M). If the thermostat has been installed at too great a depth, this can be adjusted by 27.5mm with an extension set (see fold-out page I, ref. No. 47 200). Open cold and hot water supplies. Installation of the flow control knob (S) and adjustment of the economy stop, see fold-out page II, figs. [10] to [12]. The flow rate is limited by the economy stop (O) supplied, see fig. [10]. To install the flow control knob (S), proceed as follows: 1. Close the ceramic headpart (P) by turning clockwise. 2. Install the economy stop (O) in the desired position. For possible settings, see fig. [11]. 3. Fit splined adapter (Q), see fig. [12]. 4. Fit fastening set (R). 5. Install flow control knob (S) so that the button (S1) is at top. If a higher rate is desired, the stop can be overridden by depressing the button (S1). Reversed connection (hot on right - cold on left). Replace thermostatic compact cartridge (T), see Replacement Parts, fold-out page I,Prod. no. 47 175 (1/2 ). Adjustment Installation of the temperature control handle (U) and temperature adjustment, see fold-out page III, figs. [13] and [14]. Before the mixer is put into service if the mixed water temperature measured at the point of discharge varies from the specified temperature set on the thermostat. After any maintenance operation on the thermoelement. 1. Open the shutt-off valve and check the temperature of the water with a thermometer, see fig. [13]. 2. Turn the adjusting nut (V) clockwise or anticlockwise until the water temperature reaches 38 C. 3. Fit fastening set (W), see fig. [14]. 4. Install temperature control handle (U) so that the button (U1) is at top. Temperature end stop If the temperature end stop is at 43 C, insert accompanying temperature limiter (Z) in temperature selection handle (U), see Fig. [14]. Prevention of frost damage When the domestic water system is drained, thermostat mixers must be drained separately, since non-return valves are installed in the hot and cold water connections. The complete thermostat assemblies and non-return valves must be unscrewed and removed. Maintenance Inspect and clean all parts, replace if necessary and grease with special valve grease. Shut off cold and hot water supplies. I. Thermostatic compact cartridge (T), see fold-out page III, fig. [15] to [17]. Loosen screw ring (X) using a 34mm tool. If necessary, lever out thermostatic compact cartridge (T) via recess (T1). Remove screw ring (X). Assemble in reverse order. Observe the correct installation position of the thermostatic compact cartridge (T), see detail (T2). Readjustment is necessary after every maintenance operation on the thermostatic compact cartridge (see Adjusting). II. Non-return valve (F) or (F1), see fold-out page III figs. [15], [16], [18] and [19]. Assemble in reverse order. III. Ceramic headpart (P), see fold-out page III figs. [15], [16] and [18]. Assemble in reverse order. Observe the correct mounting positions! Replacement parts, see fold-out page I ( * = special accessories). Care For directions on the care of this fitting refer to the accompanying Care Instructions. Temperature limitation The safety stop limits the temperature range to 38 C. If a higher temperature is desired, the 38 C limit can be overridden by depressing the button (U1), see fig. [14]. 2

13 14 38 C W U1 U V max. 43 C Z 15 17 T T2 X 16 34mm T1 *19 332 18 17mm 19 P F1 F 8mm III

D & +49 571 3989 333 impressum@grohe.de EST & +372 6616354 grohe@grohe.ee LV & +372 6616354 grohe@grohe.ee SK & +420 277 004 190 grohe-cz@grohe.com A & +43 1 68060 info-at@grohe.com F & +33 1 49972900 marketing-fr@grohe.com MAL & +1 800 80 6570 T & +66 2610 3685 AUS Argent Sydney & +(02) 8394 5800 Argent Melbourne & +(03) 9682 1231 B & +32 16 230660 info.be@grohe.com BG & +359 2 9719959 grohe-bulgaria@grohe.com CAU & +99 412 497 09 74 info-az@grohe.com CDN & +1 888 6447643 info@grohe.ca CH & +41 448777300 info@grohe.ch CN & +86 21 63758878 CY & +357 22 465200 info@grome.com CZ & +420 277 004 190 grohe-cz@grohe.com DK & +45 44 656800 grohe@grohe.dk E & +34 93 3368850 grohe@grohe.es FIN & +358 10 8201100 teknocalor@teknocalor.fi GB & +44 871 200 3414 info-uk@grohe.com GR & +30 210 2712908 nsapountzis@ath.forthnet.gr H & +36 1 2388045 info-hu@grohe.com HK & +852 2969 7067 info@grohe.hk I & +39 2 959401 info-it@grohe.com IND & +91 124 4933000 customercare.in@grohe.com IS & +354 515 4000 jonst@byko.is J & +81 3 32989730 info@grohe.co.jp KZ & +7 727 311 07 39 info-cac@grohe.com LT & +372 6616354 grohe@grohe.ee N & +47 22 072070 grohe@grohe.no NL & +31 79 3680133 vragen-nl@grohe.com NZ & +09/373 4324 P & +351 234 529620 commercial-pt@grohe.com PL & +48 22 5432640 biuro@grohe.com.pl RI & +62 21 2358 4751 RO & +40 21 2125050 info-ro@grohe.com ROK & +82 2 559 0790 RP & +63 2 8041617 RUS & +7 495 9819510 info@grohe.ru S & +46 771 141314 grohe@grohe.se SGP & +65 6 7385585 TR & +90 216 441 23 70 GroheTurkey@grome.com UA & +38 44 5375273 info-ua@grohe.com USA & +1 800 4447643 us-customerservice@grohe.com VN & +84 8 5413 6840 AL BiH HR KS ME MK SLO SRB & +385 1 2911470 adria-hr@grohe.com Eastern Mediterranean, Middle East - Africa Area Sales Office: & +357 22 465200 info@grome.com IR OM UAE YEM & +971 4 3318070 grohedubai@grome.com Far East Area Sales Office: & +65 6311 3600 info@grohe.com.sg www.grohe.com 2014/03/21