CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

Similar documents
IT COULD FAIL TO PERFORM AS DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT FOR THEIR SAFETY COULD SUSTAIN SEVERE PERSONAL INJURY OR DEATH.

Chillgard Refrigerant Monitor

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

RSMFM-2R MULTIFUNCTIONAL

Sensor unit MC2 with analog output for Freon gases and refrigerants

02/11/2015

02/11/2015

THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING, MAINTAINING OR SERVICING THIS PRODUCT.

21-light Remote Annunciator. Owner s Manual

RS485 MODBUS Module 8AI

DMFPM-2R MULTIFUNCTIONAL

Carbon Monoxide Transmitter

PowerLogic Branch Circuit Power Meter (BCPM)

Controllers. Instruction Manual WARNING

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

Two-Channel Gas Controller

Danfoss gas detection units

Analog Input Module IC670ALG630

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Instruction Manual WARNING

ELECTRONIC COMMUNICATING THERMOSTAT

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

MBUV-100D, MBUVS-100D MBIR-100D, MBFR-100D DIN RAIL MOUNT FLAMEWORX MODULES

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

General Specifications

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Sensor Interface Module Installation/Operation Instructions

LC1350 Level Controller

Datasheet: K-22 LO Sensor

ALARM OUTPUT MODULE. Product #7736

APPLICATION DATA SHEET

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

MODEL 9010/9020 LCD CONTROL UNIT

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Danfoss gas detection units

Operation Manual. Rev ART Infrared Refrigerant Transmitter.

mtc001 Thermocouple Converter

KIT IOM

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

NXM2G Installation and Operating Manual

Multi-Gas-Controller MGC2

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

Call stations and extensions

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Installation, Operating and Maintenance Manual

SEC Signature Process Gas Analyzer

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Temperature Controllers

RTD TEMPERATURE SENSING SYSTEM

! WARNING. Before using product, read and understand instructions.

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

Technical data sheet TDS0060

Table of Content LT 5165-UL

Instructions for the fan motor control system, SILVER C

Model 3300 Technical Support and Installation Manual

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

! WARNING. Before using product, read and understand instructions.

TTSIM-1 Sensor Interface Module

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

INSTALLATION & USER MANUAL

MC 31 Speed Controller Technical User Guide Code no GB

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

ALTAIR 5X Multigas Detector Product Specification

TECHNICAL DATA OBSOLETE

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

Built-on speed controller for GMPM plug fan with permanent magnet motor

Install Guide Customer Support: or Visit our website

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

SC Installation, Operation & Application Guide

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

S5000 Gas Monitor. GMS5000.com

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Commercial and Light Industrial Fire Alarm Control Panel

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Sensepoint XCL Fixed Gas Detector

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

HUM-M2 Humidity Sensor Module Description

DOL 31 Speed Controller Technical User Guide

Certificate of Compliance

General Specifications

Transcription:

CHILLGARD M-100 Refrigerant Sensor Operating Manual GB Order No.: 10086391/02

For the Declaration of Conformity, please visit the product page on MSAsafety.com. MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona Switzerland MSA 2017. All rights reserved

MSA CONTENTS Contents 1. Safety Regulations... 4 1.1. Correct Use... 4 1.2. Liability Information... 4 2. Description... 5 2.1. Locating the Sensor... 6 2.2. Mounting the Sensor... 6 3. Calibration... 11 3.1. Calibration Check... 11 3.2. Calibration Gases... 11 3.3. Calibration Procedure... 12 4. Operation... 13 4.1. Optical Indication... 13 4.2. Control Modules... 13 4.3. RS-485 Output Specifications... 14 4.4. RS-485 Addressing (if applicable)... 15 4.5. Gas Selection Jumpers... 15 5. Technical Specifications... 16 6. Ordering Information... 18 GB Chillgard M-100 3

SAFETY REGULATIONS MSA 1. Safety Regulations 1.1. Correct Use MSA s CHILLGARD M-100 Refrigerant Sensor hereinafter referred to as sensor is designed to detect the present of the most common halogenated refrigerants in cold storage facilities, mechanical equipment rooms and other refrigerant applications. It is imperative that this operating manual be read and observed when using the sensor. In particular, the safety instructions, as well as the information for the use and operation of the apparatus, must be carefully read and observed. Furthermore, the national regulations applicable in the user's country must be taken into account for a safe use. Danger! This product is supporting life and health. Inappropriate use, maintenance or servicing may affect the function of the device and thereby seriously compromise the user s life. Before use, the product operability must be verified. The product must not be used if the function test is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine MSA spare parts have not been used. Alternative use, or use outside this specification will be considered as non-compliance. This also applies especially to unauthorised alterations to the apparatus and to commissioning work that has not been carried out by MSA or authorised persons. 1.2. Liability Information MSA accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator. Product liability claims, warranties also as guarantees made by MSA with respect to the product are voided, if it is not used, serviced or maintained in accordance with the instructions in this manual. 4 Chillgard M-100 GB

MSA DESCRIPTION 2. Description 1 2 3 1 Base 2 ATO Code 3 Cover Fig. 1 Sensor Base and Cover Check the label provided on the printed circuit board ( Fig. 1) to identify the assemble to order (ATO) code. ATTENTION! The sensor is set at the factory to detect only one defined type of gases ( ATO code). This setting can not be changed during use. The sensor is available with a number of options including: Refrigerant gas detected Temperature and Relative Humidity sensors Output current or voltage analogue output or RS-485 ModBUS digital output De-icer option for low temperature applications. GB Chillgard M-100 5

DESCRIPTION MSA 2.1. Locating the Sensor Proper sensor location is necessary to ensure accurate measurement of representative air samples. Locate the sensor: Indoors in a room area where air circulates freely On a flat, interior surface Approximately 30-45 cm from floor. Do not locate the sensor: Near heat sources, such as appliances, direct sunlight or concealed pipes or chimneys On walls or structures subject to excessive vibration In areas where air does not circulate freely, such as behind doors or in corners. 2.2. Mounting the Sensor 60.3 80.6 58.2 59.9 55.9 Fig. 2 Installation Dimensions 6 Chillgard M-100 GB

MSA DESCRIPTION WARNING! The unit must always be powered by either a suitable UL 60950/CSA Certified power supply which is isolated from line voltage by double insulation, or an appropriately rated UL listed/csa Certified Class 2 transformer. Failure to follow the above can result in serious injury or loss of life. The sensor consists of two basic parts, the base and the cover ( Fig. 1). The cover incorporates the electronics with the sensing elements. (1) Mark four holes as shown in Fig. 2. (2) Drill holes of appropriate diameter for wall plugs. (3) Remove the cover from the base and (4) Attach base with screws of appropriate diameter. (5) Fasten the base to a junction box or other support. The base has a number of openings to allow for mounting to various junction boxes. (6) Feed the power and signal wires through the rectangular opening in the base. (7) Connect the wires to the terminal connector located in the base, as indicated in Fig. 3. See also Wiring Connections in Fig. 5. (8) If RS-485 sensors are being tied into a control device, insert a two-position jumper into J6 on the sensor board that is wired farthest from the controller. This enables the RS-485 termination resistor. (9) Align the two side tabs of the cover with the base and snap the cover onto the base. (10) Verify cover is securely attached to base by pulling on the top and bottom of the cover as shown in Fig. 4. To remove the cover, grasp it along the recesses and pull it away from the base ( Fig. 4). Alternatively, place a screwdriver into the slots indicated in Fig. 4 and twist. GB Chillgard M-100 7

DESCRIPTION MSA 2 1 1 OR 3 4 Fig. 3 Connecting Wires to Terminal Connector Fig. 4 Attaching or Removing the Cover (1) Grasp here to release (4 places) (2) Pull on top to verify attachment (3) Pull on bottom to verify attachment (4) Twist to release (4 places) 8 Chillgard M-100 GB

MSA DESCRIPTION ----- Current Output ----- ----- Voltage Output ----- MSA ModBUS Label Fig. 5 Wiring Connections GB Chillgard M-100 9

DESCRIPTION MSA 24 VAC 24 V AC line or 24 V DC+ ACN 24 V AC Neutral 24 V DC- Circuit common/analog signal reference (internally tied to ACN) Earth ground (tie to user earth connection) Gas out (ma) Gas reading as current (4 20 ma = 0 1000 ppm) Gas (+) out (V) Gas reading as voltage (2 10 V = 0 1000 ppm) RH out (ma) Relative humidity as current (4 20 ma = 0 100 % RH) RH (+) out (V) Relative humidity as voltage (2 10 V = 0 100 % RH) Temp out (ma) Temperature as current (4 20 ma = -30 C to +70 C) Temp (+) out (v) Temperature as voltage (2 10 V = -30 C to +70 C) RS-485 out b RS-485 ModBUS (b) RS-485 out a RS-485 ModBUS (a) 10 Chillgard M-100 GB

MSA CALIBRATION 3. Calibration 3.1. Calibration Check The sensor is designed to operate for long periods of time with no zero drift. However, the sensor should be checked periodically to verify that the unit detects refrigerant gas. The calibration check can be done with the use of the following MSA equipment: (P/N 603806) Polyurethane Tubing (P/N 467896) 1.5 LPM regulator. A calibration check of the sensor requires a supply of: ZERO GAS (air or nitrogen) - Ambient air may be used if it does not contain refrigerant gas or an interfering component SPAN GAS Cylinder comprised of 100 ppm of the refrigerant gas of interest. 3.2. Calibration Gases Description Concentration R-123 in Nitrogen 100 ppm R-134a in Nitrogen 100 ppm R-22 in Nitrogen 100 ppm R-404a in Nitrogen 100 ppm GB Chillgard M-100 11

CALIBRATION MSA 3.3. Calibration Procedure CAUTION! If any control instruments connected sensor are wired to external devices (e.g., horns, exhaust fans, and fire suppression systems), these devices may activate during the following procedures. To prevent activating these devices while adjusting the sensor, disconnect the wiring to the control device. Return all wiring to the control device when the calibration procedure is completed. To verify that the sensor is operating properly: (1) Deactivate any equipment connected to the outputs, or disconnect the wiring of the outputs. (2) With the tubing connected to the regulator and cylinder, place tubing in the opening at the bottom of the sensor ( Fig. 6). (3) Open the regulator and apply gas for a minimum of five minutes. (4) If the unit is operating properly, the red LED: illuminates when concentration level is > 50 ppm is visible through the calibration check opening. (5) Turn OFF regulator and remove tubing from opening. (6) Allow gas level to return to normal. (7) Reactivate any equipment connected to the outputs or reconnect the wiring to the outputs. 1 2 Fig. 6 Applying Calibration Gas 1 Regulator 1.5 LPM (P/N 467896) 2 Span Or Zero Gas Cylinder 12 Chillgard M-100 GB

MSA OPERATION 4. Operation 4.1. Optical Indication The sensor has three LEDs located at the bottom-left for quick unit status indication: LED Green Red Yellow Indication Lights during normal operation Flashes at 0.5 Hz during start-up. Turns ON solid when concentration reading exceeds 50 ppm Flashes at 0.5 Hz when power supplied is outside limits. Turns ON solid during other fault condition 4.2. Control Modules The sensor output can be connected with a control module providing a complete monitoring system ( Operating Manual of the control module). During a fault, the: current output drops to 2 ma or voltage output drops to 1 V. GB Chillgard M-100 13

OPERATION MSA 4.3. RS-485 Output Specifications Register Name PDU Address LOGICAL Address Range Fault and Module State 0x0000 1 Under Range 2 (msb) Under Voltage Temperature Lamp Fail Test Mode Warm Up Complete Cal/Setup Factory Mode Trouble Mode Gas Number 0x0001 2 0 to 40 (see below) Gas Concentration 0x0002 3-20 to 1050 (ppm) Temperature 0x002C 45-300 to +650 ( C * 10) Humidity 0x002D 46 0 to 100 (%RH) Gas Numbers R-22 = 6, R-404a = 27 R-134a = 15 R-123 = 12 Baud rate: 19,200; each byte is eight bits with no parity and two stop bits. 8 (msb) 10 (msb) 40 (msb) 80 (msb) 0 (lsb) 2 (lsb) 4 (lsb) 8 (lsb) 14 Chillgard M-100 GB

MSA OPERATION 4.4. RS-485 Addressing (if applicable) In Fig. 7 are shown the jumper settings for the 12 user configurable RS-485 addresses. MODBUS ADDRESS JUMPER SETTINGS J5 J4 J3 J5 J4 J3 J5 J4 J3 100 104 108 101 102 103 105 106 107 109 110 111 Fig. 7 Jumper Settings for the RS-485-Addresses 4.5. Gas Selection Jumpers On R-22, R-404A and R-134A the gas of interest can be changed by altering the Position of jumpers J1 and J2 as shown in Fig. 8. Fig. 8 Gas Selection Jumper Settings GB Chillgard M-100 15

TECHNICAL SPECIFICATIONS MSA 5. Technical Specifications Size Weight Power Requirements Power Consumption Wiring 115.06 mm x 90,93 mm x 36.07 mm 160 g 24 V DC, +20%, 24 V AC +20%, 50/60 Hz, Class 2, UL 60950/CSA certified < 2.7 watts up to 2,5 mm², Class 2 copper wiring Output Options 4 to 20 ma sourcing, <500 Ohm load 2-10 V, 10 kohm load RS-485 ModBUS RTU Operating Temperature 0 to 65 C (-30 degrees lower temp specification with de-icer option) Relative Humidity (RH) 0 to 99% non-condensing Pressure Operating 700-1080 hpa Warm-up time 30 minutes Pollution Degree 2 Installation Category II Operating Range 0 to 1000 ppm Limit of Detection 20 ppm Minimum Alarm 50 ppm 16 Chillgard M-100 GB

MSA TECHNICAL SPECIFICATIONS Response Time t50 < 270 seconds Repeatability ±10 ppm at 50 ppm Linearity ±10 ppm from 25-50 ppm, +20% of reading from 50 to 1000 ppm Temperature Sensor ±0.4 C at 25 C Humidity Sensor ±3% RH at 50% RH and 25 C Standard Gases *) R22, R123, R134a, R404a Approvals CE approval, complies with the applicable LVD and EMC directives (see also Declaration of Conformity) Certified to UL Std 61010-1 and CSA 61010 Complies with ASHRAE 15-2004 *) Other gases are available. Please check with factory for availability. GB Chillgard M-100 17

ORDERING INFORMATION MSA 6. Ordering Information Description Part No. R-22 in Nitrogen 10086542 R-123 in Nitrogen 10086543 R-134a in Nitrogen 10086544 R-404A in Nitrogen 10086545 18 Chillgard M-100 GB

MSA ORDERING INFORMATION GB Chillgard M-100 19

For local MSA contacts, please visit us at MSAsafety.com