Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

Similar documents
VITALink. FAQs I. GENERAL QUESTIONS

Comtran Cable. Hub-LINK Cables for Transit Applications

DuraLife TM FPL. Installation Guide. UL 2196 Fire Rated Alarm Cables. Authorities Having Jurisdiction should be consulted before installation.

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Fire Alarm/Life Safety Cable 6

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

Honeywell Cable & Custom Electronics

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

Security & Control Cables

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

NewGeneration Cables. BELDENCable TM

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL.

Quick Reference Applications Guide

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

Surviving the Survivable Cable Crunch

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

CommerciaL fire-rated

SIGA-CC1 Single Input Signal Module Installation Sheet

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Belden Infinity C-TC+ Cables for Extreme Flexing

Print Specification. Publication. Instructions. Specific requirements. General requirements

Second Revision No. 601 NFPA [ Section No [Excluding

SAS Security and Alarm Safety Cables

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Genesis. Series Low Voltage Cable. Honeywell Cable Catalog

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Fire Alarm Wiring. Circuit types, styles and limitations

Factory and Field Installed Splices

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

5. Identification products.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

Fire Resistant Cables - Update Alan Cavers Engineering Manager Certificate Services Group

WIRE & CABLE. Wire & Cable... Wire Accessories...

WIRE & CABLE. Wire & Cable... Wire Accessories...

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

INDUSTRIAL fire-rated wiring

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists

Fire Protection Coffee Break Training May 2016

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

Fire Alarm Cables WEST PENN WIRE

MORE VALUE MORE BENEFITS MORE THAN YOU IMAGINE ÖLFLEX TRAY II ÖLFLEX TRAY II CY

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

SP-1000X. Panic Device Power Controller Installation Guide. Rev

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

Applying Performance-based Fire Alarm System Design Part 4

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables

Warning Genuine Counterfeit Electrical Product

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

Multi-Core Fire Resistant Cable

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety

Flexible Power Cable DLO

SECTION ELECTRICAL GENERAL PROVISIONS

J-PRO TM Cable Support System

SECTION (16140) - WIRING DEVICES

C Electrical Connection Kit

Project 4: Active Fire Protection Systems Issues. Project 4: Investigation Team

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Public Safety DAS Annunciator Panel

PRODUCTS FOR Wiring Duct Power & Grounding Connectors Fastening Products Control Termination Identification Solutions

THE TRUE FIRE SURVIVAL CABLE

Article by: Ark Tsisserev, Principal, Stantec Consulting Ltd.

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

CADDY CORPORATION. Utility Distribution Systems

HIGH-RISE RETROFIT ORDINANCES - NO and NO

SECTION FIRE ALARM SYSTEMS

GE Total Lighting Control

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

SECTION INTRUSION DETECTION A. SCOPE OF WORK FOR DESIGNER AND CONSULTANTS

Total Fire Solutions. Includes BS 8519 and the updated BS :

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Transcription:

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables Your trusted solution for fire safety

When it comes to life and fire safety, trust the experts! Comtran has been a trusted source in the security and fire alarm market for over 30 years. Relying on this history and experience helped us to develop the most comprehensive circuit integrity cables on the market. Our VITALink 2 Hour Fire Resistive cables are the only dual listed CI/CIC cable, offering a versatile fire resistive solution for our customers. The CI rating allows the cable to be installed in free air, or without conduit, in riser and non-plenum airspace horizontal installations per NEC code. The CIC (Circuit Integrity in Conduit) rating requires use of specified hardware and installation instructions. The cable must be installed as a complete system as outlined in UL system FHIT.40A or FHIT7.40A. With either installation, VITALink CI/CIC cable will continue to operate for at least 2 hours in a fire, supporting critical life safety applications where evacuation times are beyond the capabilities of standard fire alarm cabling or when partial evacuation or relocation is required. When lives and safety are on the line, choose VITALink 2 Hour Fire Resistive cable! Withstands heat up to 1850 F and ensures 2 hour signal protection Dual listed as CI/CIC - the same cable can be installed with or without conduit Available in shielded and unshielded constructions Solid or stranded bare copper conductors available Shielded & Unshielded cables can be used within the same conduit Approved for use in the United States (CI/CIC) and Canada (In Conduit only) Sunlight resistant and wet location rated Easy to install with a flexible construction No special tools or training required No termination kits, brass fittings, or stainless steel straps needed All required hardware components are commercially available off-the-shelf FEATURING: The best conduit fill in the industry The best vertical installation distance The best product spectrum The most listings and the best ratings

About VITALink Cable CONSTRUCTION: Conductors: 12-18 AWG Solid OFHC Copper and 12-16 AWG Stranded OFHC Copper Insulation: Proprietary Low Smoke, Zero Halogen Thermoset Fire-Roc Core Assembly: Twisted Pair consisting of black and red wires Drain Wire: Stranded bare copper (Shielded constructions only) Shield: Copper/Polyester tape (Shielded constructions only) Jacket: Low Smoke, Zero Halogen Polyolefin Red (Sequential Footage Marker Provided Every 2 Feet) HARDWARE CERTIFIED (In Conduit only): ½ inch, ¾ inch, 1 inch, 1 ¼ inch, 1 ½ inch, and 2 inch EMT Conduit Allied Tube & Conduit E-Z Pull EMT, Columbia-MBF E-Z Pull EMT, or Wheatland Tube FasTrak Plus EMT ½ inch, ¾ inch, 1 inch, 1 ¼ inch, 1 ½ inch, and 2 inch Steel Compression Couplings RACO or Thomas & Betts Corp. Wiegmann NEMA 1 Enclosure/Pull Box with steel compression connectors (RACO or Thomas & Betts Corp.) Amtec wire mesh support grips when exceeding specified maximum vertical length Supports per Comtran Cable s installation instructions PART NUMBERS & CONDUIT FILL RATES (In Conduit only): Applies to both vertical and horizontal installations Part Number Nom. Diameter (Inches) Nom. Weight (Lbs./1000 ) Nom. Cap. (pf/ft.) 1/2 Max. Shielded 3/4 Max. 1 Max. 1 1/4 Max. 1 1/2 Max. 2 Max. 18/2 Solid (36397) 16/2 Solid (35785) 14/2 Solid (36316) 0.309 49 17 1 Cable 2 Cables 4 Cables 7 Cables 7 Cables 7 Cables 0.330 60 20 - - 3 Cables 6 Cables 8 Cables 10 Cables 0.353 64 25 - - 3 Cables 5 Cables 6 Cables 10 Cables Unshielded 18/2 Solid (36337) 16/2 Solid (35777) 16/2 Stranded (36341)* 14/2 Solid (36338) 14/2 Stranded (36340)* 12/2 Solid (36342)* 12/2 Stranded (36339)* 0.305 41 17 1 Cable 2 Cables 4 Cables 7 Cables 7 Cables 7 Cables 0.321 52 19 1 Cable 2 Cables 3 Cables 6 Cables 8 Cables 10 Cables 0.344 54 19 1 Cable 1 Cable 3 Cables 5 Cables 7 Cables 10 Cables 0.352 61 20 1 Cable 1 Cable 3 Cables 5 Cables 7 Cables 10 Cables 0.368 65 20 1 Cable 1 Cable 2 Cables 4 Cables 6 Cables 10 Cables 0.402 90 22 1 Cable 1 Cable 2 Cables 4 Cables 6 Cables 10 Cables 0.416 92 22 1 Cable 1 Cable 2 Cables 4 Cables 6 Cables 10 Cables *Non-stock item. Lead time and MOQ may be required. VITALink cables are proudly made in the USA

Dual Rating: CI vs. CIC Comtran s VITALink cables are the most versatile on the market, with the only dual CI/CIC rating. All VITALink cables are rated as both Circuit Integrity (CI) and Circuit Integrity in Conduit (CIC). The same cable can be installed either with or without conduit, depending on the application and code requirements. CIRCUIT INTEGRITY (CI): As CI, also referred to as CI Free Air, VITALink can be used in riser or horizontal (non-plenum) installations without conduit. The cable must be installed per the NEC code and meet all national and local code requirements. Since conduit is not required, there are no fill restrictions, which also saves money, space, time, and labor. CIRCUIT INTEGRITY IN CONDUIT (CIC): As CIC, VITALink cable must be installed as the UL approved FHIT.40A or FHIT7.40A system and in accordance with Comtran s installation instructions. This system requires use of specific hardware including conduit, couplings, pulling lubricant, pull boxes, and supports. In areas such as plenum airspace, VITALink must be installed in conduit. TESTING: Underwriters Laboratories Standard 2196 requires 5 out of 5 system tests to pass for a full 2 hours of burn time at temperatures up to 1850 F and then attack by water without loss of signal. Cable installed in a 90 curved conduit must pass the same testing in order to meet ULC-S139, the circuit integrity listing in Canada. VITALink also meets the survivability requirements in NFPA 70, NFPA 72, NFPA 130, and NFPA 502. Before and after UL burn testing. When tested as CIC, VITALink cables are pulled into conduit, secured to a wall, and terminated. The wall is connected to a furnace for 2 hours, while circuits are monitored closely for leakage current. After 2 hours, the wall is removed and exposed to a pressurized hose stream.

Applications and Standards CRITICAL SYSTEMS SUPPORTED: EVAC - Emergency Voice-Alarm Communication and Smoke and Fire Alarm Systems Fireman s Telephone & Area of Refuge Communication Systems Visible Notification Appliances Fan/Damper Pressurization Systems Fuel Leak Detection Systems Fire Pump - Feeder/Controls Smoke Control & Management Equipment Command Center Critical Systems Pressurized Stairway Systems COMMON APPLICATIONS: Manufacturing, Commercial, and Industrial locations High-rise Buildings Universities and Stadiums Hotels and Airports Health Care Facilities Tunnels and Subways for Emergency Communications Protect critical systems and ensure occupants get to safety! PERFORMANCE STANDARDS: UL Certified to ANSI/UL 2196 2-Hour fire rating for use in FHIT System 40A (See UL Fire Directory R27557) NEC Type FPLR-CI-LS, CMR-CI-LS, and PLTC-CI-LS c(ul) Listed CMR-LS CEC and CSA Listed FAS90 to C22.2 No. 208-14 CAN/ULC-S139 Certified with Hose Stream Test for use in FHIT7 System 40A UL 1424 Listed FPLR-CI-LS for Power-Limited Fire Alarm Cables; 300V / 105 C UL 13 Listed PLTC-CI-LS for Power-Limited Circuit Cables; 300V / 105 C UL 444 Listed CMR-CI-LS for Communication Cable; 300V / 105 C Fire certified for power-limited system use at 72V phase-to-phase utilization voltage Sunlight Resistant For use in Wet Locations NYC Electrical Advisory Board approval #54502, April 2017 California State Fire Marshal Approved

Wire & Cable for Specialized Needs Want to learn more? Contact us: Toll Free: 800-842-7809 Email: sales@comtrancorp.com www.comtrancorp.com Like us on Facebook: facebook.com/comtrancable Follow us on LinkedIn: linkedin.com/company/comtran-cable-llc Follow us on Twitter: twitter.com/comtrancable Watch our VITALink videos on Youtube: youtube.com/user/comtrancable