YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

Similar documents
FIRE DOOR CLOSING SYSTEMS

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

EMERGENCY RESPONSE GRILLE

/WON BuyLine 3726 WON-DOOR. FireGuard. The ORIGINAL horizontal sliding accordion fire door.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SECTION OVERHEAD COILING FIRE DOORS

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

SECTION Overhead Coiling Doors

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

FireCurtain STANDARD, gray, with steel slats UL & C-UL LISTED. Phone: RAYNOR Fax:

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

SECTION OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS

Solutions for Common Problems

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

ROLLING SERVICE FIRE. Product Line COUNTER FIRE INTEGRAL FRAME & SILL FIRE INDUSTRY LEADING COMMERCIAL & INDUSTRIAL SOLUTIONS

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

GENERAL AREAS OF INSPECTION

AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

MD Series MEDIUM DUTY SERVICE DOORS. superior product + recognized value

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

MODEL B2 INSTALLATION MANUAL

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Fire and Smoke Door Inspections Qualified Training 02/03/17

AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

R OL L ING F IR E DOOR T E S T ING P R OGR AM

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

Retail. Life Safety and Security Door Hardware. Integrated Door Security Systems. Safety, Security and Risk Management

ASSA ABLOY Revolving Doors A full range to go full circle

Regulatory Reform (Fire Safety) Order 2005

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

SAFEPATH Mass Notification System (SPMNS)

MANUAL RESET ALARM RELEASE

PHOTOLUMINESCENT EXIT SIGNS EVALUATED AND TESTED TO UL924

Module 9: Ontario Building Code Fire Fighting Provisions

Clackamas Fire District #1 Self Inspection Program. Oregon Fire Code (OFC)

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

2012 B.C. Building Code Compliance Review (Division B Part 3)

School Fire Safety Checklist

Fire Sprinkler Plan Submittal Form

Fire detection and alarm

Hand Chain (Model FCF) &

MANUAL RESET ALARM RELEASE

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Fire Suppression Installation (R-102) for AVI Hoods & XLT Ovens

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

ICU/CCU Door ASSA ABLOY VersaMax 2.0

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Firetex steel fire shutters

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Floor Warden Training. Thursday, May 27, 2015

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

CHAPTER SIX Automatic Gates

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

UNDERSTANDING SAFETY CABINETS

All by design. ASSA ABLOY Door Controls

White Papers: Delayed Egress Hardware

Access Control. Total Perimeter Protection Solutions from one Source

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

2018 NICET Code Transition Changes

HEALTH/LIFE SAFETY ANNUAL INSPECTION CHECKLIST (ROE)

2409/2900. Fire Guard

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

DONALD H. BERG, ARCHITECT

FIRE AND SAFETY PROJECT REVIEW REPORT

UK Product Guide. Fire Doors.

Full Service Central Station Fire Alarm Listing Evaluation

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

INITIAL FIRE SAFETY ASSESSMENT

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

NFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting.

2408/2900. Fire Guard

Module 7. Control of Smoke & Highlights of Code Requirements

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Bi-Directional Barrier Arm Turnstile

Innovative protection that combines power and flexibility

University Design Standard Fire Alarm Systems

Transcription:

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS Coiling Fire Doors Firemiser Insulated Fire Doors SmokeShield Fire Doors SmokeShield Firemiser Doors Coiling Counter Fire Doors SmokeShield Counter Fire Doors Labeled Integral Frame Units CrossingGard Emergency Response Grille TranZform Fire Accordion Folding Fire Door M100 FireGard Operating Systems A Complete Line of Accessories Since we opened our doors in 1828, Cornell has led the industry in providing only the highest quality products and unmatched support. Whether seeking quality, performance, reliability or overall satisfaction, customers have always known that they're Safe and Secure with Cornell.

EMERGENCY RESPONSE PRODUCTS E m e r g e n c y R e s p o n s e P r o d u c t O p e r a t o r s Opening Considerations When choosing an operator, the following opening characteristics will aid in selection: + Opening Size - How big is the opening? Larger, heavier units often require more convenient operation. + Cycle Frequency - How often will the door be opened each day? More frequent opening usually requires more efficient operation. + Activation Requirements - Is the unit required to be fail-safe and to tie into local fire detectors or a central alarm system? Basic fuselink setups do not accommodate this need. + Opening Characteristics - Does the operator need to be concealed above a ceiling, or do mounting conditions limit access to the operator? If so, consider an operating system that does not require manual resetting, thereby reducing the need for operator access. + Annual Testing Requirements - Is a simplified testing and resetting system desired? Basic systems require a trained door system technician and significant opening downtime to complete testing. Advanced systems can be tested at floor level with the touch of a button. + Power Failure Frequency - Power failures can cause a fire door to close without signal from an alarm system. Traditional closing systems require manual resetting by a trained door system technician and significant opening downtime to reset the closing system and continue normal operation. Advanced systems can be reset at floor level with the touch of a button. Electric M100 Motor Operators These systems respond to alarm signals or fuselink activation and are fail-safe by design, functioning even during a power failure. When alarms are cleared and power is restored, resetting is done at floor level with a touch of the "open" button. A sensing edge is recommended or may be required. Available for new or retrofit doors up to 51' wide, 36' high or a maximum of 1200 square feet. Benefits: + Dependable automatic closing due to simplified design. + Slower, safer, uniform closing speed of approximately six inches per second. + Resetting is done at floor level with the touch of the "open" button on the control station. + Easy to test: M100 system fire doors can be tested quickly and easily. + Versatile: M100 systems can be activated by fusible link or thermal sensors, fire alarm systems or smoke detectors without the need for a mechanical release device. Recommended Applications: + Larger size fire doors. + Fire-rated units in recessed applications. + Units in areas susceptible to frequent power outages. + Any application where mechanical testing and resetting is impractical or not desired. Options: + Battery Back Up for M100 F Series Operators + Horn Strobe + Sensing Edge + Locking Mechanisms + Operator Covers Manual M100 Chain or M100 Crank Operators These systems can be fuselink activated alone, or the system can also be tied into local detectors or a central alarm system using an operator mounted release device as listed on the back cover. Automatic closing is tested with routine close operation of the unit. Resetting spring tension or re-engaging the operator is not required! Push to close button activation in lieu of a pull cable is optional. Please consult Cornell for size availability. Benefits: + Spring tension is not released for automatic fire door closing. + Simple testing of automatic closing system. + Downtime is minimal - doors are easily reset to the open position in minutes by facility personnel following alarm or power failure closing. Recommended Applications: + Use for fire products that do not require the daily operating convenience of a motor operator. + Clearance and access to the hand chain or crank eye is required. Options: + Push To Close Station + Operator Mounted Fail-Safe Release Devices + Locking Mechanism + Operator Cover Conventional Fire Door Operators Conventional fire door automatic closing systems release spring tension and require mechanical resetting by a trained door systems technician. Although these old style fire door systems are available and frequently specified, the industry has evolved to address today's issues of annual door testing requirements, more frequent alarm testing, recessed installations and power outages. Cornell strongly recommends you consider the safety and convenience advantages the above M100 Closing Systems can provide your customers.

E m e r g e n c y R e s p o n s e P r o d u c t s Fire Doors Model ERD10 Protect against the spread of fire by automatic closing in the event of fire detection with governed speed control. Fire doors are designed for daily use to provide security and access control. + Meet insurance and building code requirements. + Compact overhead storage of curtain is ideal for industrial, commercial and institutional applications. Sizes: Standard construction for openings up to 51' wide, 36' high or 1200 sq. feet. Labels: UL 4, 3, 1 1/2, 1 or 3/4 hour label. Factory Mutual Approval. Fire wall openings in: + Hospitals and healthcare facilities + Schools + Hotels + High rise construction + Museums + Warehouses + Not for use in openings that are part of a required means of egress. Use TranZform Fire, page 3, when emergency egress is required. Firemiser Insulated Fire Doors Model ERD20 Provides UL rated fire protection plus security, sound attenuation and environmental separation. Reduce costs by meeting multiple design needs, with continued energy savings generated by Firemiser's sealing and insulation. + Sound Transmission Class: STC 27; muffles unwanted sound between areas. + Climate Control: insulated curtain yields a 5.3 R-value that can be combined with full perimeter seals. Sizes: Standard construction for openings up to 34' wide, 22' high. Consult factory for units over 768 square feet. Labels: UL 4, 3, 1 1/2, 1 or 3/4 hour label. Factory Mutual Approval. Practical Design Applications + All fire wall openings where the door is to be closed regularly and a sound attenuation need exists. + Exterior openings that require a fire rating due to the proximity of other structures or combustible materials. + Buildings designed for future expansion where current exterior wall openings are to become interior fire wall openings. + Interior fire wall openings where the door will be normally closed to control varying climatic conditions between two areas. SmokeShield UL Labeled Smoke and Draft Control Assemblies Designed to limit the spread of fire and smoke in a fire emergency protecting life and property. Equipped with UL listed and tested perimeter smoke seals that are UL labeled for proven smoke and draft control per UL 1784. These units carry two labels, one for fire protection and one for smoke and draft control. Insulated SmokeShield Firemiser units also provide climate control with a curtain that yields a 5.3 R-value, plus sound attenuation with a Sound Transmission Class STC 27. + Meets the requirements of NFPA 105 and also the International Building Code, 2006, Section 715.4.3. + Doubles protection for building occupants, capital and contents. + Controlling smoke limits property damage. + Increases life safety. SmokeShield Fire Doors Model ERD11 + Sizes: Openings up to 34' wide by 25' high. + Labels: UL 4, 3, 1 1/2, 1 or 3/4 hour label for fire and UL S label for smoke and draft control. SmokeShield Firemiser Doors Model ERD21 + Sizes: Openings up to 34' wide by 22' high. + Labels: UL 4, 3, 1 1/2, 1 or 3/4 hour label for fire and UL S label for smoke and draft control. SmokeShield Counter Fire Doors Model ERC11 + Sizes: Openings up to 16' wide when height is 7'6" or less. Openings up to 12' wide when height is 10' or less. + Labels: UL 3, 1 1/2, 1 or 3/4 hour label for fire and UL S label for smoke and draft control. + Buildings with large occupancy rates. + Buildings with significant material inventories. + SmokeShield Firemiser: Openings that will be regularly closed where there is a need for sound attenuation or climate control between two areas, and buildings designed for future expansion where the current exterior wall openings are to become interior fire wall openings, especially with significant material inventories. Individual data sheets available for each product. Contact Cornell for assistance.

Counter Fire Doors Model ERC 10 Also specified as fire shutters, these fire doors secure openings above counters and other similar finished openings on interior and exterior walls. + Meet insurance and building code requirements. + Smaller, more aesthetically pleasing guides, slats, brackets and hood than fire doors. Sizes: Openings up to 16' wide when height is 7'6" or less, or up to 12' wide when height is 10' or less. Labels: UL 3, 1 1/2, 1 or 3/4 hour labels. + Smaller openings in fire rated walls, especially above counters. + Openings to the floor where smaller components are desired. Counter Fire Doors with Integral Frames Model ERC 20 Assembled and welded at the factory for a seamless, custom look without field assembly. Built-in mounted units wrap around wall and are installed while the wall is being constructed. Slip-in units may be set into finished walls. + The look of a made-to-order product without the inconvenience. + Fully assembled, ready for placement into wall opening. Sizes: Openings up to 10' wide by 4'9" high in walls 4 1/2 to 12" thick. Labels: UL 1 1/2, 1 or 3/4 hour labels. + Service window openings for fire walls used in: + Cafeterias + Healthcare facilities + Schools and universities CrossingGard Emergency Response Grille Model ERG 10, Model ERG-IBC for Access Controlled Egress per the IBC Designed to help address both the security and safety issues of public areas. The CrossingGard provides the day to day security of a locked, rolling grille but immediately responds in an emergency situation to fully open automatically and allow escape. Provides separation control, yet allows for alternate means of egress should an emergency arise. Concealed AutoLock mechanism prevents forced opening of a closed grille, but will not interfere with normal access to egress or emergency operation. + Model ERG-IBC is ICC-ES evaluated for access controlled egress per the International Building Code + Fail-safe emergency response capability through motor operation, provided as standard. + No manual locking or unlocking required. + No resetting is necessary to resume normal operation. Sizes: Openings from 5' to 24' wide and 4' to 20' high. + Corridor protection in any public building that limits functional space at different times or for special events, such as in: + Schools + Hospitals + Office buildings + Transportation terminals + Separation control applications where emergency personnel will require immediate access to secured areas in a crisis situation. + Applications where combined ease of opening and security is desired. TRANZFORM FIRE Accordion Folding Fire Door Model ERP 10 Rated physical fire barriers that protect openings from the spread of fire and smoke. Units provide automatic closing in the event of fire detection. Requires minimal headroom. Double track / double wall panel design. + Acceptable for use in openings that are part of a required means of egress. + Compliant with the American with Disabilities Act accessibility standards. + Fail-safe emergency response capability through motor operation, provided as standard. Sizes: Virtually any width opening from 3 6 to 22 high. Labels: UL 3, 1 1/2, 1, 3/4, 1/2 hour and 20 minute and S labels available. Factory Mutual Approval. + Openings requiring building code compliant emergency egress such as elevator lobbies. + An alternative to banks of fire rated swing doors where maintaining the use of the full opening width for functionality and aesthetics is desired, such as in atriums, casinos and hotels. + Openings with minimal headroom requiring rated fire, smoke or ADA compliant fire protection. Individual data sheets available for each product. Contact Cornell for assistance.

E m e r g e n c y R e s p o n s e S o l u t i o n s f o r A l l Y o u r O p e n i n g R e q u i r e m e n t s Interior / Exterior Fire Walls Potential Requirements + Security - the ability to close and lock. + Fire Containment - product closes automatically in a fire emergency. + Smoke Control - limit the spread of smoke, which can spread faster and cause more damage than fire. + Sound Attenuation - to reduce unwanted sound from one area to another. + Weather Control - when environmental separation or high wind load is required. + Aesthetics of Opening - high traffic areas demanding a more aesthetically pleasing product. Counter Openings Product Solutions + Fire Doors - provide security and close automatically in a fire. + SmokeShield Fire Doors - limit the spread of smoke, protecting life and property in addition to fire protection. + Firemiser Insulated Fire Doors - provide temperature control or sound attenuation in addition to fire protection. + SmokeShield Firemiser Doors - provide all of the above. + TranZform Fire - provide UL rated fire and/or smoke protection with emergency egress capabilities. Require minimal headroom. + Counter Fire Doors - when compact door components are desired, these units close to the floor. Potential Requirements + Security - the ability to close and lock. + Fire Containment - product closes automatically in a fire emergency. + Smoke Control - limit the spread of smoke, which can spread faster and cause more damage than fire. + Aesthetics of Opening - when a unit with integral frame and countertop is desired. Product Solutions + Counter Fire Doors - base product provides security and close automatically in a fire. + SmokeShield Counter Fire Doors - limit the spread of smoke, protecting life and property in addition to fire protection. + Counter Fire Door with Integral Frame and Countertop - assembled and welded at the factory for seamless construction with a custom look, in addition to fire protection. Cross Corridor Potential Requirements + Egress - a closed product opens on alarm to allow access to means of exit. + Security - the ability to close and lock or prevent entry. + Fire Containment - product closes automatically in a fire emergency. + Sound Attenuation - to reduce unwanted sound from one area to another. + Smoke Control - limit the spread of smoke, which can spread faster and cause more damage than fire. Product Solutions + CrossingGard ERG - self locking assemblies prevent forced opening of closed grille. Fully opens on alarm or power failure, allowing access to egress. + TranZform Fire - provide UL rated fire and/or smoke protection with emergency egress capabilities. Require minimal headroom. + Fire Doors - provide security. Close automatically in a fire emergency. + SmokeShield Fire Doors -limit the spread of smoke, protecting life and property in addition to fire protection. + Firemiser Insulated Fire Doors - provide temperature control or sound attenuation in addition to fire protection. + SmokeShield Firemiser Doors - combines the benefits of Fire Doors, SmokeShield Fire Doors and Firemiser Insulated Fire Doors.

A c c e s s o r i e s Release Devices On-Board Release Device M100 Chain Operator FireGard DC shown, BB and BV units similar. Conventional Fire Door Annunciators Perimeter Seals Electro-mechanical devices enable automatic closing fire doors to respond to alarm signals from detection devices such as smoke detectors, heat sensors and central alarm signals, permitting doors to close long before high temperatures melt fusible links. Fusible links should always be used as backup to the release device. M100 Chain and Crank Release Devices: + Floor Level Cable Reset Model + Automatic Reset Model Conventional (Non-M100) Fire Door Release Devices: + FireGard DC- ties into and receives 24 volt DC power from a central alarm system with a back-up power source. + FireGard BB - self contained 72 hour internal battery back-up + FireGard BV - like BB unit, but with a voice warning board and a 24 hour internal battery back-up. Speaker Strobe compatible. Can be tied into FireGard BB / BV release devices to safely pre-announce closing of the fire door. + Horn Strobe - ADA compliant, 24 volt DC warning devices are powered by the release device battery source to provide advanced fire door closing warning, even during a power failure. + Speaker Strobe - An ADA compliant FireGard BV warning device. Provides two different voice warning messages upon activation. Messages are in English and are field selectable. 2. 3. 1. Vision Windows + UL listed Perimeter Seals provide weather protection on fire doors and insulated fire doors when a smoke label is not required. Perimeter seals can also be used to add protection against the passage of smoke and drafts for Fire Doors that are outside the limits of SmokeShield Doors. 1. UL Listed Perimeter Seal at Guide 2. UL Listed Perimeter Seal at Header 3. UL Listed Perimeter Seal at Bottom Bar + Smoke Seal / Electric Sensing Edge - offer personal safety at the opening and serve as an alternative bottom seal for motorized fire doors. Different profiles, 2-wire and 4-wire are available. UL Labeled Countertops D e s i g n A s s i s t a n c e Available for non-insulated Fire Doors, vision windows enhance life safety and convenience by allowing visibility to the other side of the firewall opening. Up to six 10" x 1 5/8" panes panes per curtain, spaced a minimum of 5" apart and 12" in from each guide. Placement, quantity and layout of panes is to be set by specifier. Conveniently completes fire rated counter openings. UL 1 ½ hour rated. + Plastic laminate countertops are available in a range of standard laminates in a single piece up to 10' wide, and in two pieces with center joint to 16' wide. + Stainless steel countertops are 14 gauge, #4 finish. Custom designed to a maximum wall opening width of 11'2" for face of wall units (T-shape), and 11'10" for between jambs units (rectangular shape). Maximum 12" wall thickness. Cornell employs full time professionals to assist architects in specifying emergency response products. Contact our Architect & Design Support Department at 800.233.8366 ext. 551 or ADS@cornelliron.com. Our website, www.cornelliron.com, provides access to extensive, continually updated product information, including downloadable specifications, drawings and data sheets. Cornell's comprehensive Rolling Door Resource Manual is newly updated and available for your reference library. Make Cornell your single source for Emergency Response Closure Products. SAFE AND SECURE Printed with Pride in the USA 50% Recycled Paper Crestwood Industrial Park Mountaintop, PA 18707 Tel. 800.233.8366 Fax 800.526.0841 www.cornelliron.com An ISO 9001:2000 Registered Company Rev. 1.007 Cornell Iron Works, Inc.