Group Quality Certification System of Air Cleaners for Air Conditioners

Similar documents
THE EVALUATION OF MULTI-ZONE AIR FLOW PATTERN AND VENTILATION RATES WITH TRACER GAS METHODS IN APARTMENT HOUSE

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

The Cannabis Industry: Fire Department Requirements

A Study on Safety by Risk Assessment of Clean Room

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

KIAS-AORC Joint Workshop

VISITORS FROM KOREA TO IIASA

Ammonia Detection System Codes and Design Specifications

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

(h) Pesticide Application.

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

ICC CODE CORNER 2015 International Fire Code

Refrigerants Type Expensive Coefficient of Performance Toxic

Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air.

A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET

A study on performance improvement of corrugated type total heat exchanger considering the structure of flow passage on surface

An experimental study of the impact of tunnel suppression on tunnel ventilation

Frequently Asked Questions

Breathe Easy with Sharp Plasmacluster Air Purifiers

ORDINANCE NO

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

Air Conditioning System Sizing for Pure Electric Vehicle

Residential Duct Mount Builder s Box Media Air Cleaner

Environmental Health and Safety Biological Safety Program Guidance Document

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS

An Experimental Study of the Air-Side Particulate Fouling in Fin-and-Tube Heat Exchangers of Air Conditioners

AIR POLLUTION CONTROL REGULATION NO. 23 CONTROL OF PERCHLOROETHYLENE EMISSIONS FROM DRY CLEANING OPERATIONS. Promulgated December 2, 2003

Providing Solutions. Simplifying Regulation. IIAR Standards. Peter Thomas, P.E., CSP Resource Compliance, Inc.

Introduction to Fans. The Basics of Fan Principles and Terminology

The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps

REFRIGERATION CHAPTER 11

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

P R O D U C T D ATA S H E E T

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dae-Hyun Jin. 8/2018-Present Assistant Professor of Mechanical Engineering, Taylor University, USA

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Rain City Initiative Proposed by Suwon City, Korea

Smoke detection in hazardous areas:

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

H-Ion cluster. H-ion Cluster s thunderbolt effect creates the premier indoor air. Sterilization. Deodorization. Removing Harmful Materials

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

Effect of the Electro Breeze Air Filter on Airborne Particles in a Recirculating Air Duct

High Performance Diesel Fueled Cabin Heater. Abstract

CHEMICAL FUME HOOD PROGRAM

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

Electronic Air Cleaner Model Number CSC1000 OWNER S MANUAL. Installation Operation Basic Service Guide Technical Repair Guide Repair Parts

Laboratory Fume Cupboards

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

COMPLIANCE INSPECTION CHECKLIST. Date: 12/20/12 Time In: 1:00PM Time Out: 1:30PM

Equipment guide for local exhaust ventilation (LEV)

Capture Waste Heat with Ultra-High Efficiency

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Incident Summary (Reference # ) (DRAFT)

AT-G-SENSE Gas Sensing System

MICRO CLIMA-SERIES TM (COOLED) INCUBATORS AND WALLS

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Challenges and Methods of Estimating a Conceptual HVAC Design

Aspirating Smoke Detection for Duct Monitoring

Hazard Zone Locations: HAZARD ZONE CHECKLIST

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

RAGAGEP UPDATE. Douglas Reindl, Director, IRC 2016 IRC R&T Forum

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

2 OZONFILT And Bono Zon Ozone Plants

INSTY-PAC EXTERNAL MOUNT MULTIPLE TUBE ASSEMBLY

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Performance Characteristic and Optimization of a Simultaneous Heating and Cooling Multi Heat Pump

City of Grover Beach Building Division Fire & Life Safety Requirements CANNABIS CULTIVATION, MANUFACTURING AND LABORATORY FACILITIES

HAZARDOUS MATERIALS (HAZMAT)

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

CMF, CMX & CMA series

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

Fire Department Fire Prevention Inspection Services. HIGH RISE STRUCTURE Fire Inspection Program

NACT 287 Dry Cleaning

The blank report forms are enclosed. If additional blank forms are needed you may contact my office at (210) and ask for Maria Castoreno.

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

D AN ISH BU IL D IN G R ESEAR C H IN ST IT U T E ( SBI ) /AAL BO R G U N IVER SIT Y C O PEN H AG EN ALIREZA AFSHARI-PROFESSOR

Installation Instructions

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

Technical Note # 01.05

Study on the Effects of Learning by Changing the Color- Temperature LED Lamp

Transcription:

Group Quality Certification System of Air Cleaners for Air Conditioners (CAC Mark) KOREA AIR CLEANING ASSOCIATION

1. Overview What is the group quality certification system of air cleaners for air conditioners (CAC mark)? The mark is granted to products which pass thorough tests by certified test agencies based on group standards on air cleaners for air conditioners established by the CAC on major functions including the deodorizing efficiency and ozone production concentration to provide reliable air cleners for air conditioners to customers. Consumers may purchase the products with the CAC mark with satisfaction. Procedure for certifying the CAC mark [Figure 1] Procedure for certifying the CAC mark - 2 -

1. Apply for and receive the CAC certification test (company > association) 2. Receive and check the application form and perform site inspection on selecting prototypes (association > company) 3. Request the performance evaluation test to designated (national research institute) test agencies (association > test agency) 4. Notify the performance evaluation test (test agency > association) 5. Open the review board on granting the CAC certification mark 6. Issue the CAC report from the Korea Air Cleaning Association (association > company) 7. Apply for issuing the CAC certificate and its certified notification (company > association) 8. Issue the CAC certification and certified document and manage follow-up 2. Test method and certification standard How to test the air cleaner for the air conditioner The performance test of the air cleaner for the air conditioner is performed in a place with the temperature of 23±5 and the atmospheric pressure of 760±20mmHg with no wind in case of no specific conditions. - The airflow test performed in accordance with the schedule 1 of the KS C 9304 by operating the air cleaner with rating frequency and voltage. - Removing fine dusts (cleaning) test is done by installing the test body on the test duct, flowing the rating airflow, checking the stabilization of particle concentration and alternatively checking the particle concentrations on the inlet and the outlet to calculate the removal ratio based on the formula. - 3 -

1From ventilator 2cleaning filter 3test particle generator 4infuse pipe for test particles 5more than A 6bell mouse 7rectifying grid 8more than B/2 9place measuring static pressure 10measurement range of upstream concentration 11test particle fixture 12place measuring static pressure 13particle counter 14pipe for taking upstream test particles 15gasket 16test material 17pipe for taking downstream test particles 18flow measurement 19orifice [Fig. 2] Schematic View of Duct for Testing Fine Dust Removal Rate - Removing hazardous gas (deodorizing efficiency) test is performed under the air environment below. a) Temperature: 23±5, b) Relative humidity: 55±15%, c) Dust and gas concentration: Below the indoor environment standard in the public sanitation act The gases under the test include: a) ammonia (NH 3 ),b)acetealdehyde(ch 3 CHO)andc)acetate(CH 3 COOH) - 4 -

1Diffuser 2test material 3agitating fan 4enclosed chamber 5gas generator 6activated carbon filter 7ventilator 8exhaust [Fig. 3] Configuring Test Chamber for Toxic Gas Removal Test and Gas Supply Line - The ozone production test is performed before the test removing fine dusts and hazardous gases from the test body. The test is performed under the air environment condition below. a) Temperature: 23±5, b) Relative humidity: 55±15%, c) Dust and gas concentration: Below the indoor environment standard in the public sanitation act The chamber and the test room shall be measured in the chamber for removal test or an indoor space with the volume of (29.5±1)m3 (lower than 3m of the ceiling). The test body shall be installed in the center of the test room and be placed about 75cm above the floor for measurement on the table. - 5 -

Item and standard for certification - The range of applying the CAC certification mark Test and certification item Benchmark Remarks Rating airflow (applied area) Display performance Cleaning performance (removing fine dusts) Display performance Rates of removing hazardous gases (Deodorizing efficiency) Higher than 50% Benchmark for ozone production (ppm) Less than 0.05ppm [Table 1] Certification items and benchmark for the CAC certification mark - The rating airflow (applied area) and the cleaning performance show the performance test result. - It shall have higher than 50% of the deodorizing efficiency (removing hazardous gases) and remove more than 0.5 liter per 1m3/min. - The ozone production benchmark shall have less than 0.05ppm of the maximum value of the ozone production concentration. - 6 -

3. List of review board Review board for the CAC certification mark No Name Title Company Name Position Remarks 1 Yoonshin Kim Professor Hanyang University (head of the board) Industrial medical school 2 Woongi Lee HQ Director Korea Testing & Research Institute Customer Service HQ 3 Dongwon Yoon Professor Kyungwon University 4 Myungwoon Kim Professor Daejin University 5 Taesung Kim Professor Sungkyunkwan University 6 Kyunghoon Yoo Chief researcher Korea Institute of Industrial Technology 7 Jungho Hwang Professor Yonsei University Construction Facilities Environment Engineering Mechanical Engineering Convergent Technology R&D Division 연구부 Mechanical Engineering 8 Eunyoung Lee Vice Manager of Planning Consumers Korea 9 Sunghwan Kim Professor Dankuk University Microbiology 10 Hyunjoon Moon Professor Dankuk University 11 Myungdo Oh Professor University of Seoul Architecture Mechanical and Information Engineering Head of the Office of Planning and Research - 7 -

4. Status of Certified Test Organizations Status of certified test organizations as of 2013 (Period of consignment: January 1, 2013 - December 31, 2014) No Organization Remarks 1 Korea Conformity Laboratories 2 Korea Institute of Machinery & Materials 3 Center for Mechanical Parts and Material Technology Support in the Busan Techno Park 5. Certification status Status of CAC mark certification - Status of CAC certification products and companies (as of March 31, 2013) Total: 6 models of 2 companies - 8 -