CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Similar documents
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau. Permit fees shall be assessed in accordance with the Permit Fee Schedule

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Fire Sprinkler Submittal Requirements and Acceptance Testing

May 1, Dear Fire Suppression System Contractor/Designer:

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

September 30, Dear Fire Suppression System Contractor/Designer:

City of Vista Fire Department

AUTOMATIC FIRE SPRINKLER SYSTEMS

Bold items are particular to the City of Euless

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Broward County Utility Connection Permit Part One Application for Plan Review

APPENDIX H (DESIGN SUBMISSION CRITERIA)

FIRE SPRINKLER SYSTEMS POLICY

FIRE & LIFE SAFTEY STANDARD

FIRE SPRINKLER SYSTEMS POLICY

NASSAU COUNTY FIRE PROTECTION PERMIT APPLICATION

Fire Prevention Coffee Break Training. February 2016

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Fire Protection Systems Plan Review

Medical Gas and Vacuum Systems

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV (702) FAX (702)

FIRE SUPPRESSION SYSTEM REVIEW APPLICATION 1. NEW PLAN REVIEW RESUBMITTAL

FIRE SPRINKLER SHOP DRAWING SUBMITTAL REQUIREMENTS

FIRE-FLOW REQUIREMENTS FOR BUILDINGS Based on the 2012 Edition of the International Fire Code

Community Development Department Commercial Permit Application

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

MONTECITO FIRE PROTECTION DISTRICT

City of Reedley Community Development Department 1733 Ninth Street Reedley, CA (559) FAX

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

LANDSCAPE AND IRRIGATION PLAN PREPARATION GUIDELINES

Title: Fire Sprinkler System Permit Requirements

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Fire Sprinkler System Design and Installation Requirements

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

CITY OF PASADENA FIRE DEPARTMENT

D. Reference Standards (Utilize latest editions available):

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Design & Construction Standards, Revised January

You are required to READ ALL PAGES. of this application

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

To expedite the plan review and inspection processes, please refer to the information below.

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

CONSTRUCTION SERVICES GUIDE FOR UNIVERSITY OF FLORIDA FACILITIES

DATE: CHECK AMOUNT: CHECK NUMBER: RENEWAL APPLICATION. COMPANY CERTIFICATE OF REGISTRATION And INDIVIDUAL LICENSE RENEWAL

Design & Construction Standards, Revised January

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

LANDSCAPE PLAN CHECK COMMUNITY FACILITY DISTRICT (CFD)/HOA PERFORMANCE

Carrollton Fire Rescue

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

ANNUAL / Renewable TOTAL: $

WESTIN HOTEL. Smoke Control System. Testing Procedures Manual. October 10, Copyright Impact Engineering, Inc All Rights Reserved

WEST VIRGINIA UNIVERSITY

AIRPORT OFFICE BUILDING. Smoke Control System. Testing Procedures Manual. September 10, 2016

Brighton Area Fire Authority

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

SECTION POLICY MANUAL

7/1/2018-6/31/2019 PROTECTION AND PLANNING FEE SCHEDULE

Environmental Health & Safety

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

DIVISION 21 FIRE SUPPRESSION

SECTION : FIRE PROTECTION SYSTEMS

CONTRACT FOR USE OF FIRE PROTECTION SYSTEM

Center for Life Safety Education

5.07 Air Replenishment Systems

New Construction Fire Inspection Process

Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:

Regulations Governing Fire Protection Systems That will be connected to the Town of Wayland Municipal Fire Alarm System.

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

Application for Certification for an Alarm System Contractor

City of Attleboro, Massachusetts WATER DEPARTMENT Government Center, 77 Park Street Attleboro, Massachusetts Phone Fax

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

BUILDING PERMIT APPLICATION REQUIREMENTS FOR GROUND MOUNTED PHOTOVOLTAIC SYSTEMS

Fire Prevention Coffee Break Training. February 2017

SECTION WET-PIPE SPRINKLER SYSTEMS

Plan Submittal Checklist

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

VIOLET TOWNSHIP ZONING & BUILDING DEPARTMENT Rustic Drive Pickerington, Ohio (614) Fax (614)

Redlands Fire Department Fire Protection Standard

Fire District Dwelling Construction Requirements

DESIGN & CONSTRUCTION GUIDELINES

PRIVATE FIRE SERVICE INSTALLATION PACKET

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

Transcription:

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.7.1 Control Number: I.0 Effective Date: 12/15/11 TITLE: HYDRANT TEST FOR SPRINKLER DESIGN SCOPE: Clark County Fire Department requirements for the submittal and approval of flow tests used in sprinkler design. PURPOSE: To standardize requirements for hydrant tests to determine water supply for sprinkler design. DEFINITIONS: ASSESSOR S PARCEL NUMBER (APN): A unique number assigned to each property by the Clark County Assessor s office. PERMIT FEES: Permit fees shall be assessed in accordance with the Permit Fee Schedule as adopted in the Clark County Fire Code. For applications that are expedited, additional fees shall apply. SPECIFICATIONS AND REQUIREMENTS: An application must be completed for each submittal. A minimum of three copies of the plan must be submitted (see example) with the permit application. All submittals must be legible and readable or the plan shall be rejected for cause. The hydrant flow test shall be conducted in accordance with the Clark County Fire Code, and NFPA 291. Plans shall address the following: 1. Location of fire hydrants to be used in flow test must be indicated. Indicate which hydrant is to be read and which is to be flowed. 2. Indicate location of building with which the hydrant test is associated 3. Indicate distance from the test hydrants to the building. Maximum 750 feet distance allowed. 4. Indicate results to be recorded. At a minimum, the static, residual, pitot, orifice diameter and flow achieved must recorded. 5. Indicate the date the flow test will occur. Flow test information must be within 6 months of sprinkler system application date. Page 1 of 5

PERMIT REVISIONS AND RESUBMITTALS: Revisions to approved plans are required to be submitted and approved. Revisions will be assessed additional plan review fees. A copy of the previously approved plan shall accompany the revised submittal to facilitate the review. Clearly indicate all changes to the revised plans by clouding the change with a delta number to signify the date of plan change. When several changes have been made, a detailed list of changes is required. Re-submittals to address a Letter of Correction will require a full submittal. These plans require a copy of the red lined plan from the previous submittal to facilitate the review. Clearly indicate all changes by clouding the change with the delta number to signify the date of plan change. PLANS CHECK STATUS INSTRUCTIONS: The status of the review can be checked by logging on to: www.clarkcountynv.gov/depts/fire. INSPECTION SCHEDULING INSTRUCTIONS: If approved, an inspection will need to be scheduled. To schedule an inspection, also go to: www.clarkcountynv.gov/depts/fire. A fire inspector will review your site in accordance with the approved plans and this guideline. Inspection Procedure: 1. Contractor shall provide equipment used for the test. Gauges shall be calibrated as required by the manufacturer. 2. The gauge hydrant, as identified on the plan, shall have a gauge screwed onto one of the fire hydrant outlets. 3. The gauge hydrant shall be used to determine the static pressure and the residual pressure during flow. 4. Residual pressure must be a minimum of 10 psi lower than the static pressure. a. Exception: Where all three outlets have been opened on the flow hydrant and the pressure drop is still not 10 psi, then the minimum of 10 psi pressure drop is not required. 5. The flow hydrant, as identified on the plan, shall have one or more outlets opened, starting with the 2.5 inch outlets. The flow shall be measured from all open outlets, utilizing the corrective factors in NFPA 291. Flows from multiple outlets must be added together. 6. The fire inspector will witness the test and record the results on an inspection record. A copy of the inspection record will be given to the contractor to be utilized for fire sprinkler system design. A copy of the inspection record shall be added to the fire sprinkler submittal. Page 2 of 5

The Clark County Fire Department s Fire Prevention Bureau (FPB) may witness and accept inspection, testing and maintenance of fire and life safety systems conducted by approved individuals as required by and within the scope and authority of the Clark County Fire Code This Guideline does not take the place of the Fire Code and does not take precedence over any Fire Code requirement or position taken by the Fire Chief. When a conflict exists between the requirements of this Guideline and the Fire Code or the opinion of the Fire Chief, the Fire Code or opinion of the Fire Chief prevails. Technical Assistance, when required by the fire chief, will require a Technical Opinion and Report prepared by a State of Nevada licensed: qualified engineer, specialist, laboratory, or fire safety specialty organization acceptable to the Fire Chief and the owner. The Fire Chief is authorized to require design submittals to bear the Wet Stamp and Signature of a professional engineer. Acceptance of Alternative Materials and Methods requires a Technical Opinion and Report prepared by a State of Nevada licensed: qualified engineer, specialist, laboratory, or fire safety specialty organization acceptable to the Fire Chief and the owner. The Fire Chief is authorized to require design submittals to bear the Wet Stamp and Signature of a professional engineer. Page 3 of 5

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 FIRE HYDRANT FLOW TEST CONTRACTOR: PH. NO. E-MAIL NAME OF PROJECT: LOCATION: N Static: Residual: Pitot: Orifice Diameter: Flow Achieved: Distance to Structure: Page 4 of 5

Pitot Pressure* (PSI) Orifice Size (in.) Pitot Pressure* (PSI) Orifice Size (in.) 2.5 4 2.5 4 1 168.3 416.4 42 1088.1 2311.2 2 237.6 589.3 44 1113.3 2365.7 3 290.7 684.8 46 1138.5 2418.8 4 335.7 765.0 48 1162.8 2471.1 5 375.3 826.6 50 1187.1 2521.9 6 411.3 883.8 52 1210.5 2571.9 7 443.7 943.5 54 1233.0 2620.5 8 475.2 1008.5 56 1256.4 2669.0 9 504.0 1069.7 58 1278.0 2716.1 10 531.0 1128.0 60 1300.5 2762.4 11 557.1 1182.5 62 1322.1 2808.0 12 581.4 1235.5 64 1342.8 2853.5 13 604.8 1285.6 66 1363.5 2897.6 14 628.2 1334.1 68 1384.2 2940.9 15 649.8 1381.2 70 1404.0 2984.3 16 671.4 1426.8 72 1424.7 3026.1 17 692.1 1470.8 74 1443.6 3067.9 18 711.9 1513.4 76 1463.4 3109.0 19 731.7 1554.5 78 1482.3 3150.1 20 750.6 1594.8 80 1501.2 3189.7 22 787.5 1672.5 82 1520.1 3229.3 24 822.6 1747.2 84 1538.1 3268.9 26 855.9 1818.2 86 1557.0 3307.7 28 888.3 1886.9 88 1575.0 3345.8 30 919.8 1953.4 90 1592.1 3383.2 32 949.5 2017.6 92 1610.1 3420.5 34 978.3 2079.6 94 1627.2 3457.9 36 1007.1 2140.2 96 1644.3 3494.5 38 1035.0 2198.4 98 1661.4 3530.3 40 1062.0 2255.9 100 1678.5 3566.2 2.5 flows: Q=29.84cd 2 p with c =.9 4 flows: use coefficient.9 and the figures from this Table 4.8.2 from NFPA 291: Pitot Pressure (Velocity Head) Psi Coefficient 2 0.97 3 0.92 4 0.89 5 0.86 6 0.84 7 and over 0.83 Page 5 of 5