FLASHLIGHT ANSI STANDARDS

Similar documents
FLASHLIGHT ANSI STANDARDS

IECEx Certificate of Conformity

IECEx Certificate of Conformity

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE SPECIFICATION FOR LED HEADLAMP, FIREFIGHTER

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Declaration of Conformity

IECEx Certificate of Conformity

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

IECEx Certificate of Conformity

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Fenix Implements ANSI Standard (Refers to ANSI/NEMA FL-1 Standard) Fenixlight Limited ANSI/NEMA FL-1 standard

Fenix Implements ANSI Standard

Fenix LD20 R5 Announcement

IECEx Certificate of Conformity

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

IECEx Certificate of Conformity

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

IECEx Certificate of Conformity

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

IECEx Certificate of Conformity

IECEx Certificate of Conformity

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

IECEx Certificate of Conformity

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

IECEx Certificate of Conform ity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Certificate of Compliance

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

IECEx Certificate of Conformity

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

IECEx Certificate of Conformity

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Certificate of Compliance

Certificate of Compliance

srra, of Conformity IECEx Gert f cate ?-ot,b

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

IECEx Certificate of Conformity

Inductive slot sensor

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

IECEx Certificate of Conformity

Certificate of Compliance

IECEx Certificate of Conformity

INTERNATIONAL STANDARD

IECEx Certificate of Conformity

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

IECEx Certificate of Conformity

For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust, Solid Objects, and Moisture) for Luminaire Enclosures

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

(German speaking trainers with English written slides)

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Certificate of Compliance

TECHNICAL SPECIFICATION

Certificate of Compliance

Safe Operation Manual. Honeywell IQ Force Gas Detector

Certificate of Compliance

IECEx Certificate of Conformity

INTRINSICALLY SAFE LIGHTING RANGE

An Urgent Bulletin from CSA Group

American National Standard. for Roadway and Area Lighting Equipment Solid State Light Sources Used in Roadway and Area Lighting ANSI C136.

IECEx Certificate of Conformity

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems


Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

American National Standard. for Roadway and Area Lighting Equipment Solar Lighting Systems ANSI C Secretariat:

Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service)

IECEx Certificate of Conformity

Annubar Flowmeter Series

Guide for hazardous areas

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

safety & regulatory information

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

Fire Performance of Translucent Systems

CoreLine Batten the clear choice for LED

Certification Supplement Manual

EMIRATES CONFORMITY ASSESSMENT SCHEME (ECAS): ECASEx COMPLIANCE

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

Technical Data. General specifications. Rated operating distance s n 5 mm

INTERNATIONAL STANDARD

Certificate of Conformity

Certification Supplement Manual

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Certificate of Compliance

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Certification Supplement Manual

Transcription:

FLASHLIGHT ANSI STANDARDS While Pelican was one of the first manufacturers to use quantifiable test procedures, the need was recognized to develop a common language that customers could use to select the right flashlight for their specific needs. As a result, the American National Standards Institute (ANSI) with input from the flashlight industry, developed performance standards and symbols to effectively communicate a flashlight's features and benefits. Resulting ANSI/NEMA FL 1 Standards include the six criteria described below: LIGHT OUTPUT Light Output is the total luminous flux. It is the total quantity of emitted overall light energy as measure by integrating the entire angular output of the portable light source. Light output in this standart is expressed in units of lumens. RUN TIME Run Time is defined as the duraton of time from the initial light output value defined as 30 secons after the point the device is first turned on using fresh batteries, until the light output reaches 10% of the initial value. BEAM DISTANCE Beam Distance is defined as the distance from the device at which the light beam is 0.25 lux (0.25 lux is approximately the equivalent of the light emitted from the full moon "on a clear night in an open field"). PEAK BEAM INTENSITY Peak Beam Intensity is the maximum luminous intensity typically along the central axis of a cone of light. The value is reported in candela and does not change with distance. IMPACT RESISTANCE Impact Resistance is the degree to which a device resists damage from dropping on a solid surface. IPX4 WATER PENETRATION RATINGS IPX4 - Water Resistance - Water splashed against the device from any direction shall have no harmful effects. IPX4 / IPX7 WATER PENETRATION RATINGS IPX7 - Water Proof - Ingress of water in quantities causing harmful effects shall not be possible when the enclosure is temporarily immersed in water under standardized conditions of pressure and time. IPX8 - Submersible - Ingress of water in quantities causing harmful effects shall not be possible when the enclosure is continuously immersed in water under conditions which shall be stated by manufacturer, but which are more severe than for IPX7.

ANSI (AMERICAN NATIONAL STANDARDS INSITUTE) These standards are accredited by ANSI, which is a private non-profit organization that oversees the development of voluntary consensus standards for products, services, processes, systems, and personnel in the United States. The organization also coordinates U.S. standards with international standards so American products can be used globally. GLOSSARY OF TERMS Candela - A unit of measurement of the intensity of light that is, power emitted by a light source in a particular direction. Lux - The unit of luminous flux in the International System, equal to the amount of light given out through a solid angle by a source of one candela intensity radiating equally in all directions. Lumen - A unit of measurement of the amount of brightness that comes from a light source. Lumens define "luminous flux," which is energy within the range of frequencies we perceive as light. Integrating Sphere - An integrating sphere is a measurement device with an entrance port that can accept all the directional light output of the device under test, or can totally enclose the device itself. The walls of the sphere should be highly diffuse with high reflectivity (>80%) and the spectroradiometer should be shielded from direct view of the device under test by a baffle system. IP (Ingress Protection) - Ingress Protection (IP) ratings specify the environmental protection the enclosure provides. The IP rating normally has two numbers (IPXX). The first number represents protection from solid objects or materials (dust) where the second number represents protection from liquids (water). With the IP rating IP 54, 5 describes the level of protection from solid objects and 4 describes the level of protection from liquids.

AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Pelican Products Manufacturer: Pelican Products Party Authorized To Apply Mark: Report Issuing Office: Control Number: 3091325 Same as Manufacturer DALLAS, TX Authorized by: William T. Starr, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Portable Luminaires, CSA C22.2 No. 12-1982 General Instructions No. 1-4 December 1996 Intrinsically Safe and Non-incendive Equipment or Use in Hazardous Locations, CSA C22.2 No. 157-92 (R2006) Standard(s): Electric Flashlights and Lanterns for Use in Hazardous (Classified) Locations, UL-783 sixth edition, July 18, 2007 Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, III, Division 1, Hazardous (Classified) Locations, UL-913, 7th edition, June 3, 2010

AUTHORIZATION TO MARK Product: Hand Held Flashlight For use in:class I,II,III Division 1, Groups A,B,C,D,E,F,G with an operating Temperature Class of T4 with an ambient Temperature of -20C to +40C when powered by four Size "AA" Alkaline batteries all batteries must be from the same manufacturer, changed at the same time, and from one of the following three manufacturers types: Panasonic Plus LR3, Philips Powerlife LR03, and Energizer LR3) Brand Name: Little ED Models: 3610, 2410, Pelican Stealthlite 2410 LED, Pelican Little ED 3610 LED

INTERNATIONAL ELECTROTECHNICAL COMMISSION Certificate No.: IECEx ITS 09.0017X Status: Current 2014-06-2 Applicant: Pelican Products Inc. Electrical Apparatus: Optional accessory: Pelican Stealthllte 241 O Recoil LED Pelican Little Ed 3610 Recoil LED Type of Protection: Intrinsic safety la Marking: Ex ia llc T4 Ga Ex ia lllc T135 C Da IP66 IECEx ITS 09.0017X Approved for issue on behalf of the IECEx Certification Body: A Dickinson Position: Certification Officer Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. lntertek

Certificate No: IECEx ITS 09.0017X Issue No: 2 2014-06-02 Manufacturer: Pelican Products Inc. Additional Manufacturing location(s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0: 2007-10 Edition:5 IEC 60079-11 : 2006 Edition:5 IEC 60079-26 : 2006 Edition:2 IEC 61241-11: 2005 Edition:1 Explosive atmospheres - Part O:Equipment - General requirements Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga Electrical apparatus for use in the presence of combustible dusts - Part 11: Protection by intrinsic safety 'id'

Certificate No: IECEx ITS 09.0017X 201+-06-2 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: The equipment is a LED flashlight type Stealth Lite 241 O Recoil LED. fitted with four 1.5V AA alkaline cells powering a circuit board and a LED light source inside a plastic enclosure. The Little Ed 3610 Recoil LED is a right angle version of the 2410. The protection concept applied is intrinsic safety ia for use in hazardous gas and combustible dusts atmospheres Only the following 1.5V AA alkaline batteries are permitted to be fitted Energizer Philips Power1ife Panasonic Plus CONDITIONS OF CERTIFICATION: YES as shown below: The following w arnings are marked on the equipment Do not open in hazardous area. Do not mix cells from other manufacturers. Replace all cells at the same time.

Certificate No: IECEx ITS 09.0017X Issue No: 2 2014-06-02 DETAILS OF CERTIFICATE CHANGES (for Issues 1 and above): Issue 1 To fit a new 2414C LED module resulting in a change in the marking for explosive dust atmospheres from Ex ia lllc T83 C Da IP66 to Ex ia lllc T135 C Da IP66. Issue 2 This new issue of the certificate is issued to show that the Ex CB responsible for the QAR has now been changed. US/FMG/QAR06.0003 and US/FMG/QAR09.0001 for Pelican Products has been superseded ( GB/FME/QAROS.0002 valid at date of issue).

AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Pelican Products Manufacturer: Pelican Products Party Authorized To Apply Mark: Report Issuing Office: Control Number: 3091325 Same as Manufacturer DALLAS, TX Authorized by: William T. Starr, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Portable Luminaires, CSA C22.2 No. 12-1982 General Instructions No. 1-4 December 1996 Intrinsically Safe and Non-incendive Equipment or Use in Hazardous Locations, CSA C22.2 No. 157-92 (R2006) Standard(s): Electric Flashlights and Lanterns for Use in Hazardous (Classified) Locations, UL-783 sixth edition, July 18, 2007 Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, III, Division 1, Hazardous (Classified) Locations, UL-913, 7th edition, June 3, 2010

AUTHORIZATION TO MARK Product: Hand Held Flashlight For use in:class I,II,III Division 1, Groups A,B,C,D,E,F,G with an operating Temperature Class of T4 with an ambient Temperature of -20C to +40C when powered by four Size "AA" Alkaline batteries all batteries must be from the same manufacturer, changed at the same time, and from one of the following three manufacturers types: Panasonic Plus LR3, Philips Powerlife LR03, and Energizer LR3) Brand Name: Little ED Models: 3610, 2410, Pelican Stealthlite 2410 LED, Pelican Little ED 3610 LED

INTERNATIONAL ELECTROTECHNICAL COMMISSION Certificate No.: IECEx ITS 09.0017X Status: Current 2014-06-2 Applicant: Pelican Products Inc. Electrical Apparatus: Optional accessory: Pelican Stealthllte 241 O Recoil LED Pelican Little Ed 3610 Recoil LED Type of Protection: Intrinsic safety la Marking: Ex ia llc T4 Ga Ex ia lllc T135 C Da IP66 IECEx ITS 09.0017X Approved for issue on behalf of the IECEx Certification Body: A Dickinson Position: Certification Officer Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. lntertek

Certificate No: IECEx ITS 09.0017X Issue No: 2 2014-06-02 Manufacturer: Pelican Products Inc. Additional Manufacturing location(s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0: 2007-10 Edition:5 IEC 60079-11 : 2006 Edition:5 IEC 60079-26 : 2006 Edition:2 IEC 61241-11: 2005 Edition:1 Explosive atmospheres - Part O:Equipment - General requirements Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga Electrical apparatus for use in the presence of combustible dusts - Part 11: Protection by intrinsic safety 'id'

Certificate No: IECEx ITS 09.0017X Issue No: 2 201+-06-2 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: The equipment is a LED flashlight type Stealth Lite 241 O Recoil LED. fitted with four 1.5V AA alkaline cells powering a circuit board and a LED light source inside a plastic enclosure. The Little Ed 3610 Recoil LED is a right angle version of the 2410. The protection concept applied is intrinsic safety ia for use in hazardous gas and combustible dusts atmospheres Only the following 1.5V AA alkaline batteries are permitted to be fitted Energizer Philips Power1ife Panasonic Plus CONDITIONS OF CERTIFICATION: YES as shown below: The following w arnings are marked on the equipment Do not open in hazardous area. Do not mix cells from other manufacturers. Replace all cells at the same time.

Certificate No: IECEx ITS 09.0017X Issue No: 2 2014-06-02 DETAILS OF CERTIFICATE CHANGES (for Issues 1 and above): Issue 1 To fit a new 2414C LED module resulting in a change in the marking for explosive dust atmospheres from Ex ia lllc T83 C Da IP66 to Ex ia lllc T135 C Da IP66. Issue 2 This new issue of the certificate is issued to show that the Ex CB responsible for the QAR has now been changed. US/FMG/QAR06.0003 and US/FMG/QAR09.0001 for Pelican Products has been superseded ( GB/FME/QAROS.0002 valid at date of issue).