Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

Similar documents
Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

Experimentation of Heat Pipe Used In Nano-Fluids

American International Journal of Research in Science, Technology, Engineering & Mathematics

Thermal Performance of a Loop Thermosyphon

Review of Thermosyphon heat exchanger charged with hybrid nanofluid for waste heat recovery applications

International Engineering Research Journal Experimental Investigation of Effect of length on Performance of Axially Grooved Heat Pipe.

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

HEAT PIPES

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

A study of Transient Performance of A Cascade Heat Pump System

Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2,

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

PERFORMANCE OF WATER FILLED THERMOSYPHONS BETWEEN OC

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

ICMIEE Experimental Investigation of an Air to Air Heat Pipe Heat Exchanger for Moderate Temperature Waste Heat Recovery

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Heat Recovery Units. Heat Recovery 1

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Operation of a Two-Phase Reverse Loop Thermosyphon

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

II. OBJECTIVE OF RESEARCH

Closed Loop Pulsating Heat Pipe with a Hydrocarbon as Working Fluid: A Review

Experimental Study of Fins Effect on Thermal Performance of HPHX for Air Conditioning System

Mallikarjun 1, Anandkumar S Malipatil 2

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Investigation of Two Phase Closed Thermosyphon Using Propylene Glycol As A Working Fluid

Research Article Analyzing the Heat Transfer Property of Heat Pipe Influenced by Integrated Cooling Apparatus

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

DEEPAK PALIWAL, S.P.S.RAJPUT

Development of the Micro Capillary Pumped Loop for Electronic Cooling

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

AXIAL TEMPERATURE DISTRIBUTION AND PERFORMANCE OF R410A AND WATER FILLED THERMOSYPHON AT VARIOUS FILL RATIOS AND INCLINATIONS

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

Performance of non-cfc refrigerator driven by chilled water from 35 kw LiBr/H2O solar absorption cooling system

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

Experimental Investigation of Heat Transfer Enhancement Techniques in Two Phase Closed Thermosyphon

Compression of Fins pipe and simple Heat pipe Using CFD

EXPERIMENTAL STUDY ON THE LOOP HEAT PIPE OPERATING UNDER HORIZONTAL ORIENTATION

Efficient adsorption refrigerators integrated with heat pipes

Niti KAMMUANG-LUE *, Phrut SAKULCHANGSATJATAI, and Pradit TERDTOON

15. Heat Pipes in Electronics (1)

EXPERIMENTAL PERFORMANCE OF AN R410A-FILLED C-SHAPE THERMOSYPHON

Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Heat Dissipation in Control Panel using Heat Pipe

Development of a meter-scale U-shaped Oscillating Heat Pipe for GAPS

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Performance Analysis of a Solid Desiccant Air Dehumidifier

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

VISUAL STUDY ON TWO-PHASE FLOW IN A HORIZONTAL CLOSED-LOOP OSCILLATING HEAT PIPE , Thailand , Thailand

Adsorption refrigeration system using waste heat

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Recent Advances in Energy, Environment and Economic Development

Experimental Investigation of an Indirect Evaporative Cooler Consisting of a Heat Pipe Embedded in Porous Ceramic

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

Passive cooling of telecommunication outdoor cabinets for mobile base station

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Recovery Using Heat Pipe Heat Exchanger with Hybrid Nanofluid

Small Scale Pilot Plant Thermal Dryer for Sewage Sludge Dewatering System A Preliminary Study

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Temperature Oscillation of mlhp with Flat Evaporator

Mathematical Simulation of Longan Fruit Drying

Performance Study of Triple Concentric Pipe Heat Exchanger

A Novel Heat Recovery System for High Temperature and High Humidity Gas Qing Hao1, a, Meng Si2, b

Transcription:

2011 International Conference on Communication Engineering and Networks IPCSIT vol.19 (2011) (2011) IACSIT Press, Singapore Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe Teerapot Wessapan and Theerapong Borirak Department of Mechanical Engineering, Eastern Asia University, Pathumthani, Thailand e-mail: teerapot@eau.ac.th, theerapong@eau.ac.th Abstract. In this research, experimental study on waste heat recovery from the pyrolysis stack using heat pipe with both wick and wickless heat pipe has been investigated. The heat pipe is fabricated from the straight copper tube with the outer diameter and length of 15 and 600 mm respectively. The operating temperature inside the heat pipe is monitored at various flow rates of cooling water. The air-to-water heat pipe heat exchanger is designed, constructed and tested under operating conditions of pyrolysis oven using water as the working fluid. Effects of water flow rate, heat pipe tilt angle and heat pipe configuration (wick and wickless) on the thermal efficiency of heat pipe are considered. Considering the fact that this is one of the first practical applications of heat pipe waste heat recovery from the pyrolysis stack, it has given informative results and paved the way for further research. Keywords-Heat pipe; Heat transfer; Waste heat recovery 1. Introduction Pyrolysis can be defined as the thermal decomposition of organic material through the application of heat in the absence of oxygen. The Pyrolysis process is an advanced conversion technology that has the ability to produce a clean, high calorific value gas from a wide variety of waste and biomass streams. The hydrocarbon content of the waste is converted into a gas, which is suitable for utilisation in either gas engines, with associated electricity generation, or in boiler applications without the need for flue gas treatment. Waste heat from pyrolysis process (200-300 C) can be used to heat the water, which is suitable for the household in order to use instead of adding a separate water heater. Heat pipes are devices that efficiently transport thermal energy from their one point to the other. A heat pipe is hermetically sealed tubes containing a working fluid in both the liquid and vapor phases. Heat pipe utilizes the highly efficient thermal transport process of evaporation and condensation to transport heat from one end to the other where the heat can be dissipated through a heat sink. It utilizes the latent heat of the vaporized working fluid instead of the sensible heat. As a result, the effective thermal conductivity may be several orders of magnitudes higher than that of the good solid conductors. Renewable energy is a high profile and rapidly emerging technology which is attracting financial incentives. While waste heat found in the exhaust gas of various processes such as pyrolysis and can be used to heat the water. This is one of the basic methods for recovery of waste heat. Currently, there are many different technologies in operation. However, heat pipes are more desirable than conventional systems, when considering system efficiency, reliability, and the ease and cost of manufacturing. Heat pipes are also one of the most effective devices for waste heat recovery. A major advantage of using heat pipes over conventional methods is the possibility to transport large quantities of heat through a small cross-sectional area over a considerable distance with no additional power input to the system. Furthermore, simplicity of design and manufacturing, small end-to-end temperature drops, maintain performance over a wide temperature range and the ability to control and transport high heat rates at various temperature levels 57

are unique features of heat pipes [1-3]. There are many researches presented the heat transfer characteristics of the heat pipe [4-7]. Although the operating condition of a heat pipe is simple, its appropriate design and construction is complicated. In order to recover waste heat from the pyrolysis stack, the parameters concerned should be controlled and experimental investigations are very important. In this research, the air-to-water heat pipe heat exchanger is designed, constructed and tested under operating conditions of pyrolysis oven, using water as the working fluid. Effects of water flow rate, heat pipe tilt angle and heat pipe configuration (wick and wickless) on the thermal efficiency of heat pipe are considered. In order to reduce the impact of temperature fluctuation, the operating temperature of the pyrolysis stack is maintained over a range of from 200 C to 220 C. 2. Experimental Apparatus and Procedure The heat pipes both wicked and wickless types are designed and manufactured to carry out the tests depicted in Figure 1. The heat pipe is fabricated from the straight copper tube with the outer diameter and length of 15and 500mm, respectively, as shown in Figure 2. Wick heat pipe Figure 1. Wickless heat pipe Wicked and wickless heat pipes Figure 2. The heat pipe dimensions Before being charged, the pipe is cleaned thoroughly with methanol to remove any traces of fluid, grease, or oil from the inner surface. The heat pipe is then filled using a glass syringe. Vacuum gauges were fitted to both heat pipes (wick and wickless). They were evacuated down to 0.001 mm Hg before filling with their respective fluids. All tubes were sealed by providing vacuum valves after filling. Any leakage during 58

operation would be detected by the vacuum gauges. After charging the heat pipe with the working fluid and purging for non-condensable gases, the heat pipe is prepared for experiments. Fill liquid is distilled water at 50% fill ratio. The heat pipe is equipped with a total of ten T-Type thermocouples to monitor the temperature distribution along the length of the heat pipe and position in relation to the heat output/input interfaces. Finally, the operating temperature inside the heat pipe is monitored, equipped with a T-Type thermocouple, onto the evaporator (lower) end of the heat pipe. The evaporator end is equipped with a high-temperature pyrolysis stack capable of providing approximately 200 C of temperature into the heat pipe. The condenser section (top) is fabricated to allow for a water flow heat exchanger to be sealed over it. The stack inlet temperature for the high-temperature experiments is around 200 C, and it is around 30 C for the water experiments. Computer Data logger T2 T4 Heat pipe With Wick T6 T1 Stack Hot Section Adiabatic Section Cold Section Heat pipe Without Wick in out Hot Section Adiabatic Section Cold Section in T3 T5 T7 out T8 Flow meter Drain Pump Cold Water Tank Figure 3. Schematic diagram of the testing facility A schematic diagram of the experimental apparatus is shown in Figure 3.The test loop consists of a test section, refrigerant loop, water supplied system and data acquisition system. The water is pumped out of the storage tank, and is passed through a flow meter, test section (condenser section). The flow rates of the cold water are controlled by adjusting the valve and measured by the flow meter. Experiments were conducted at various water flow rates, and tilt angles of the heat pipe. In the experiments, tile angle of heat pipe is increased in small increments while the supplied temperature of the pyrolysis stack at evaporator section of the heat pipe is kept constant. The temperatures at each position were recorded three times by a data acquisition system. 3. Results and Discussion The operation test was conducted to study the efficiency of the heat pipe by using two different heat pipe configurations (wick and wickless), with heat pipe tilt angle of 0-90 at water flow rate 0.5, 1.0, and 1.5 l/min. Figure 4. Variation of heat pipe thermal efficiency with tilt angle of heat pipe at water flow rate of 0.5 l/min 59

Figure 5. Variation of heat pipe thermal efficiency with tilt angle of heat pipe at water flow rate of 1.0 l/min Figure 6. Variation of heat pipe thermal efficiency with tilt angle of heat pipe at water flow rate of 1.5 l/min Figures 4-6 show the variation of heat pipe thermal efficiency with heat pipe tilt angle of heat pipe with wick and wickless, respectively. It is found that the heat pipe efficiency relates to tilt angle. This is because the gravitational force has a significant effect on the thermal efficiency of the heat pipe. For both heat pipe configuration (wick and wickless), when the heat pipe has a tilt angle of 60, the heat pipe will has maximum thermal efficiency. Moreover, the results found that the water flow rate influences the pipe thermal efficiency as shown in Figure 7. It is found that when the heat pipe tilt angle is kept constant at 60, the heat pipe thermal efficiency increases with decreasing water flow rate. Figure 7. Variation of heat pipe thermal efficiency with heat pipe configuration (wick and wickless) for different flow rate For comparison of thermal efficiency of heat pipe with wick and wickless, it is found that the thermal efficiency of heat pipe with wick is obviously greater than in the case of the wickless heat pipe. 60

4. Conclusion This paper investigated the experimental study on waste heat recovery from the pyrolysis stack using heat pipe both with wick and wickless. The results showed that, for both heat pipe configuration (wick and wickless), the heat pipe has maximum thermal efficiency when the heat pipe has a tilt angle of 60 and thermal efficiency of heat pipe with wick heat pipe is greater than in the case of the wickless heat pipe. The heat pipe with wick achieves thermal efficiency 25-40% higher than that of the wickless heat pipe by enhancing the capillary action of the fluid to the evaporator side and helps the fluid adhere to the internal walls of the tube to increase surface area. The results of this study clearly support widening the application of heat recovery of a stack by using a heat pipe to use with water heating system in the general way. Future research should develop the unit in industrial level. 5. Acknowledgment The authors wish to express their sincere to Dr. Sombat Teekasap, Sitthichai Wanasit, Phanupong Roipila, and Pongsak Intawong of the mechanical engineering department, Eastern Asia University for helping us with this research. The authors wish to express our gratitude to Eastern Asia University for all its support. 6. References [1] A. Faghri, Heat Pipe Science and Technology, Taylor & Francis, Lexington: USA, 1995. [2] P.D. Dunn and D.A. Reay, Heat Pipe, Pergamon Press: USA, 1994. [3] J.G. Marten Terpstra and V. Vean, Heat Pipes Construction and Application, Elsevier Applied Science, New York, USA, 1987. [4] S.H. Noie-Baghban and G.R. Majideian, Waste heat recovery using heat pipe heat exchanger (HPHE) for surgery rooms in hospitals, Applied Thermal Engineering, 20, 2000, pp. 1271 1282. [5] P. Naphon, P. Assadamongkol, and T. Borirak, Experimental investigation of titanium nanofluids on the heat pipe thermal efficiency, International Communications in Heat and Mass Transfer, 35, 2008, pp. 1316 1319. [6] H. Jouhara and A.J. Robinson, An Experimental Study of Small-Diameter Wickless Heat Pipes Operating in the Temperature Range 200 C to 450 C, Heat Transfer Engineering, 30, 2009, pp. 1041 1048. [7] K. S. Ong, Experimental Performance of R-134a-Filled and Water-Filled Loop Heat Pipe Heat Exchangers, Heat Transfer Engineering, 31, 2010, pp. 1091 1097. 61